Search NASA⌕ Search

SEARCH · Search NASA

Results for “water heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Heat dissipation systems with hygroscopic working fluid

A heat dissipation system apparatus and method of operation using hygroscopic working fluid for use in a wide variety of environments for absorbed water in the hygroscopic working fluid to be released to minimize water consumption in the heat dissipation system apparatus for effective cooling in environments having little available water for use in cooling systems. The system comprises a low-volatility, hygroscopic working fluid to reject thermal energy directly to ambient air. The low-volatility and hygroscopic nature of the working fluid prevents complete evaporation of the fluid and a net consumption of water for cooling, and direct-contact heat exchange allows for the creation of large interfacial surface areas for effective heat transfer. Specific methods of operation prevent the crystallization of the desiccant from the hygrosopic working fluid under various environmental conditions.

Martin, Christopher L.↗

A Numerical Study on the Energy Performance of a Novel Furnace With Acidic Gas Trap Absorbers

Natural gas furnaces are widely used in US residential and commercial building markets. An important issue for natural gas furnaces is serious corrosion and fouling problems caused by acidic gas, such as SOx. An advanced adsorption technology based on acidic gas trap (AGT) absorbers offers the possibility to remove SOx acidic gas from natural gas furnaces with high efficiency and low cost, thereby enabling the development of condensing furnaces without the use of expensive corrosion resistant materials in the heat exchanger. A three-dimensional (3D) computational fluid dynamics (CFD) model has been developed to evaluate the heat transfer performance of a furnace with AGT absorbers and to compare it with a baseline conventional furnace without the AGT. Moreover, an axisymmetric model has been built focusing on the absorbing process in the AGT. The baseline conventional furnace used for the study is a commercial condensing furnace (Rheem 92% AFUE 84,000 BTU Multi-Position Gas Furnace). This furnace was completely disassembled, and the dimensions of each part were carefully measured and used to build a detailed CFD model. A model representing the new furnace, incorporating the AGT absorbers, was developed by adding the AGT system to the conventional furnace model. For the CFD analysis, a mixture model was employed to characterize the heat and mass transfer during the condensing process in the furnace while considering three components—air, water vapor and liquid water. Condensation takes place in the condensing heat exchanger, where water vapor changes phase to liquid water, and the latent heat is thus used in the furnace for useful heating. The simulation results characterize the energy performance of both the conventional furnace and the novel furnace with AGT absorbers, as well as the reactive processing in the AGT. These results provide insightful guidance for the development of the AGT absorber-based furnace from the perspective of its energy performance and will be used to further optimize this novel furnace design.

Laclair, Tim↗

Exploration of a Novel Technique for Waste Heat Recovery Through Molecular Dynamics: Influence of Wettability and Electric Field on Water and Water-Based Nanofluids

Most of the energy produced globally comes by way of a heat engine. The Carnot principle places a limit as to how thermodynamically efficient a heat engine can be. There is no heat engine that can be 100% thermodynamically efficient and as such a substantial proportion of all heat supplied to a heat engine is lost as waste heat. Waste heat therefore is a large energy source ready to be properly utilized. Herein, a novel approach for converting waste heat to electricity is discussed. It involves the use of the liquid to vapor phase change of a material dielectric (water) or electrolyte (nanofluid) in the embodiment of a capacitor for direct thermal to electrostatic energy conversion. While this method of waste heat recovery could potentially be added to the ever expanding portfolio of energy conversion techniques, a number of aspects must be addressed before it can be brought into practice. Water was seen as an ideal dielectric phase change material given its high relative permittivity ratio when in the liquid form as compared to its vapor form. However, given its short voltage holdoff time the phase change of water would need to occur rapidly. This brings up concerns of explosive boiling. Herein, molecular dynamics analysis into the explosive boiling behavior of thin water films gave more insight into how the interaction between the surface and liquid affected explosive boiling onset time. A Lennard-Jones potential with one interaction site and a Morse potential with three interaction sites between water and solid substrate were used. It was found generally that a stronger interaction between water film and substrate led to faster explosive boiling onset times but an increase in the number of interaction sites delayed explosive boiling, even at the same wettability (contact angle). Understanding changes in the density and enthalpy of vaporization of a liquid dielectric such as water in the presence of an electric field is of importance due to the electrostatic nature of the waste heat conversion method under consideration. Specifically, if both density and enthalpy of vaporization are increased, the thermodynamic efficiency of the waste heat conversion method under consideration is decreased. Electric field effects are explored herein via molecular dynamics using two water models, the TIP4P-Ew and SWM4-NDP. The SWM4-NDP model is polarizable while the TIP4P-Ew model is not, which allows for a determination of the importance of model polarizability (i.e. variation in water model dipole moment) on these two properties of water when subjected to an electric field. Herein it was found that both water models respond similarly in terms of density and vaporization enthalpy variance upon the introduction of an electric field. Comparison was also made to the pressure induced by the electric field (electrostriction pressure) by way of a density comparison and it was found that the predicted electrostriction pressure overestimates the pressure experienced by water. Water by itself has a high enthalpy of vaporization, which limits the efficiency of the newly proposed conversion method. Research both experimental and through simulation has shown that the vaporization enthalpy of nanofluids can be engineered via nanoparticle size and material selection. An avenue less explored is manipulating the enthalpy of vaporization by altering the interaction strength between the nanoparticles and the base fluid. In practice this could be achieved through the addition of coatings to the nanoparticles to alter their wettability to the base fluid. This was explored by using a Lennard-Jones potential and Morse potential to model the interaction between base fluid (water) and the nanoparticle. For nanoparticles 2nm in diameter and at weight percentages up to 6%, the change in vaporization enthalpy due to alterations of the interaction strength between nanoparticle and base fluid was not significant (less than a 1% difference) when compared to the effect of altering the weight percentage of nanoparticles in the nanofluid or introducing an electric field. However, the effect of wettability may still become important at other nanoparticle concentrations and sizes. In all, the studies presented here further the understanding of phase change and thermodynamic properties of water and water based nanofluids under an electrostatic field which will help inform the development of a novel approach to waste heat conversion. The reduction of waste heat will improve energy sustainability outlooks.

30 DIRECT ENERGY CONVERSION↗

What can the GRACE seasonal cycle tell us about lake-aquifer interactions?

Lake-aquifer interactions have been the subject of investigation and debate for decades. Traditional investigation methods include measurement of water flux across the groundwater-surface water interface, application of heat and environmental tracer methods, conducting numerical simulations of the water flow, and mass balance-based approaches. We first review, evaluate and describe the different approaches that have been applied for examining lake-aquifer interactions and propose an additional complementary approach. While the leakage from lakes and its slow movement through porous media (laminar flow) is well characterized by existing methods, modeling the rapid and turbulent flow through preferred pathways (faults/karst) remains a challenging task. To better understand the nature, and the full scale, of the lake aquifer interactions, and using Lake Nasser and the underlying Dakhla subbasin of the Nubian Sandstone Aquifer System (NSAS) in the Western Desert of Egypt (area: 0.66 x 10 6 km 2 ) as a test site, we examine, model, and correlate temporally and spatially, the variations in Gravity Recovery and Climate Experiment terrestrial water storage (GRACE TWS ) solutions, with precipitation, lake levels, area, and water volume. We review current GRACE applications in hydrology and present our novel approach. Findings include: firstly, large seasonal fluctuations (peak: Nov./Dec.; trough: July/Aug.) in Lake Nasser's surface water levels (average annual fluctuations: from 3.7 m to 7.5 m), area (average area: 3622 km 2 but up to 4530 km 2 ), and volume (annual average: 13.4 km 3 , and up to 34 km 3 ) are observed throughout years 2006 to 2015. These fluctuations are accompanied by an increase in GRACE TWS (average: 50 ± 13 mm/yr, up to 77 ± 18 mm/yr) over Lake Nasser and by a progression of a front of increasing GRACE TWS values (> 50 ± 13 mm) away from the lake reaching distances of up to 700 km some 3 to 5 months following peak lake level periods. The areas witnessing the seasonal increase in GRACE TWS display a progressive increase in phase and decrease in amplitude with distance from the lake. Secondly, the negligible precipitation over the Dakhla subbasin cannot account for the observed seasonal GRACE TWS patterns and neither can the leakage signal from Lake Nasser. Thirdly, overall similarities in the distribution of GRACE TWS seasonal spatial patterns are observed. During high lake level periods (e.g., Dec. 2007; Feb. 2015) additional, and more distant, areas from Lake Nasser saw increases in GRACE TWS and vice versa during low lake level periods (e.g., July 2006; Aug. 2010). These observations are consistent with Lake Nasser being the main source of modern recharge for the Dakhla subbasin and suggest a new conceptual model for the subbasin: a slow groundwater flow through a porous matrix and a rapid groundwater flow along a network of faults, fractures, and karst topography across the matrix. We suggest that the proposed conceptual model for the interaction between Lake Nasser and the Dakhla subbasin could be applicable to aquifers of similar geologic, climatic, and hydrologic settings worldwide and that approaches similar to those advocated here could be used to investigate the validity of this suggestion.

54 ENVIRONMENTAL SCIENCES↗

Diesel fuel properties of renewable polyoxymethylene ethers with structural diversity

Polyoxymethylene ethers (POMEs) are a class of low-soot and high-cetane oxygenate oligomers of structure RO-(CH 2 O-) $n$ -R, with different chain lengths ($n$) and end-groups (R) that determine their diesel-like fuel properties. Commercial POMEs with methyl end-groups (MM-POME 3-6 ) exhibit undesirably low energy density and high-water solubility. A previous computational assessment indicated that the lower heating value (LHV) and water solubility for MM-POME 3-6 both improve upon end-group exchange with larger butyl, $iso$-butyl and $iso$-pentyl end-groups. Here, we expanded upon our initial trans-acetalization reaction that employed 1-butanol to install butyl end-groups to also include branched, higher carbon-number end-groups using $iso$-butanol and fusel oil as reagents. Additionally, these new products are termed $i$B*POME 1-6 , and FOil*POME 1-5 , respectively, and collectively referred to as R*POMEs. They possess the advantaged properties of the parent MM-POME 3-6 while exhibiting higher LHV (31 MJ kg -1 and 28 MJ kg -1 for $i$B*POME 1-6 , and FOil*POME 1-5 , respectively) and much reduced water solubility (2.7 g L -1 and 1 g L -1 for $i$B*POME 1-6 , and FOil*POME 1-5 , respectively). Additional fuel property analyses were performed using 20 vol% blends of the R*POMEs with a base diesel fuel. Overall, the greater energy density and decreased water solubility of the R*POMEs, as well as their synergistic blending with diesel at moderate blend levels, provide the greatest benefits to consumers and position this group of products as an environmentally friendlier blendstock alternative to the commercially available MM-POME 3-6 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improvements of SAM Heat Transfer Models for Molten Salt-Cooled Pebble Bed Reactors

To support the development and utilization of the SAM code for molten salt-cooled pebble bed reactor safety analyses and licensing, selected improvements were made to the one-dimensional system-level heat transfer modeling in SAM with the goal of better capturing heat transfer phenomena specific to these designs. In consideration of molten salt as a coolant, new models were introduced to capture the enhanced radiative heat transfer that must be considered at the higher working temperatures. Radiative heat transfer is handled not only between two structural surfaces, but also in combination between the surfaces and the molten salt fluid, which has a higher opacity and absorption of radiative heat as compared to water. Several examples of analytical verification of the new radiative heat transfer methods are included in this report. Additionally, convective heat transfer correlations were selected from literature and included in SAM to account for the enhanced heat transfer expected in pebble bed geometry flows. These correlations are verified and demonstrated in the present work with a reference FHR example.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Real-time latent heat emission during dynamic-compression freezing of water

Abstract Dynamic compression studies have been used to study the nucleation kinetics of water to ice VII for decades. Diagnostics such as photon Doppler velocimetry, transmission loss, and imaging have been used to measure pressure/density, and phase fraction, while temperature has remained the difficult thermodynamic property to quantify. In this work, we measured pressure/density and implemented a diagnostic to measure the temperature. In doing so the temperature shows quasi-isentropically compressed liquid water forms ice at pressures below the previously defined metastable limit, and the liquid phase is not hypercoooled as previously thought above that limit. Instead, the latent heat raises the temperature to the liquid-ice-VII melt line, where it remains with increasing pressure. We propose a hypothesis to corroborate these results with previous work on dynamic compression freezing. These results provide constraints for nucleation models, and suggest this technique be used to investigate phase transitions in other materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial heterogeneity effects on land surface modeling of water and energy partitioning

Abstract. Understanding the influence of land surface heterogeneity on surface water and energy fluxes is crucial for modeling earth system variability and change. This study investigates the effects of four dominant heterogeneity sources on land surface modeling, including atmospheric forcing (ATM), soil properties (SOIL), land use and land cover (LULC), and topography (TOPO). Our analysis focused on their impacts on the partitioning of precipitation (P) into evapotranspiration (ET) and runoff (R), partitioning of net radiation into sensible heat and latent heat, and corresponding water and energy fluxes. An initial set of 16 experiments were performed over the continental US (CONUS) using the E3SM land model (ELMv1) with different combinations of heterogeneous and homogeneous datasets. The Sobol' total and first-order sensitivity indices were utilized to quantify the relative importance of the four heterogeneity sources. Sobol' total sensitivity index measures the total heterogeneity effects induced by a given heterogeneity source, consisting of the contribution from its own heterogeneity (i.e., the first-order index) and its interactions with other heterogeneity sources. ATM and LULC are the most dominant heterogeneity sources in determining spatial variability of water and energy partitioning, mainly contributed by their own heterogeneity and slightly contributed by their interactions with other heterogeneity sources. Their heterogeneity effects are complementary, both spatially and temporally. The overall impacts of SOIL and TOPO are negligible, except TOPO dominates the spatial variability of R/P across the transitional climate zone between the arid western and humid eastern CONUS. Accounting for more heterogeneity sources improves the simulated spatial variability of water and energy fluxes when compared with ERA5-Land reanalysis dataset. An additional set of 13 experiments identified the most critical components within each heterogeneity source, which are precipitation, temperature, and longwave radiation for ATM, soil texture, and soil color for SOIL and maximum fractional saturated area parameter for TOPO.

54 ENVIRONMENTAL SCIENCES↗

A co-opted steroid synthesis gene, maintained in sorghum but not maize, is associated with a divergence in leaf wax chemistry

Significance Virtually all above-ground plant surfaces, such as leaf and stem exteriors, are covered in a cuticle: a wax-infused polyester. This waxy biocomposite is the largest interface between Earth’s biosphere and atmosphere. Its chemical composition is not only highly tuned to mediate nonstomatal water loss, but it also self-assembles to produce superhydrophobic surfaces, protects against UV radiation, and contains bioactive compounds that help resist microbial attack. Developing fundamental knowledge of waxy biocomposites, particularly those on crop species, is a prerequisite for an understanding of their structure–function relationships. Here, we uncover a likely genetic basis for the presence and absence, respectively, of triterpenoids in the leaf waxes of sorghum and maize—compounds previously associated with creating heat-tolerant cuticular water barriers.

09 BIOMASS FUELS↗

Divergent species-specific impacts of whole ecosystem warming and elevated CO 2 on vegetation water relations in an ombrotrophic peatland

Boreal peatland forests have relatively low species diversity and thus impacts of climate change on one or more dominant species could shift ecosystem function. Despite abundant soil water availability, shallowly rooted vascular plants within peatlands may not be able to meet foliar demand for water under drought or heat events that increase vapor pressure deficits while reducing near surface water availability, although concurrent increases in atmospheric CO 2 could buffer resultant hydraulic stress. We assessed plant water relations of co-occurring shrub (primarily Rhododendron groenlandicum and Chamaedaphne calyculata) and tree (Picea mariana and Larix laricina) species prior to, and in response to whole ecosystem warming (0 to +9°C) and elevated CO 2 using 12.8-m diameter open-top enclosures installed within an ombrotrophic bog. Water relations (water potential [Ψ], turgor loss point, foliar and root hydraulic conductivity) were assessed prior to treatment initiation, then Ψ and peak sap flow (trees only) assessed after 1 or 2 years of treatments. Under the higher temperature treatments, L. laricina Ψ exceeded its turgor loss point, increased its peak sap flow, and was not able to recover Ψ overnight. In contrast, P. mariana operated below its turgor loss point and maintained constant Ψ and sap flow across warming treatments. Similarly, C. calyculata Ψ stress increased with temperature while R. groenlandicum Ψ remained at pretreatment levels. The more anisohydric behavior of L. laricina and C. calyculata may provide greater net C uptake with warming, while the more conservative P. mariana and R. groenlandicum maintained greater hydraulic safety. These latter species also responded to elevated CO 2 by reduced Ψ stress, which may also help limit hydraulic failure during periods of extreme drought or heat in the future. Along with Sphagnum moss, the species-specific responses of peatland vascular communities to drier or hotter conditions will shape boreal peatland composition and function in the future.

59 BASIC BIOLOGICAL SCIENCES↗

Using the Shallow Strain Tensor to Characterize Deep Geologic Reservoirs

Abstract Storing and recovering water, carbon, and heat from geologic reservoirs is central to managing resources in a changing climate. We tested the hypothesis that the strain tensor caused by injecting or producing fluids can be measured at shallow depths and interpreted to advance understanding of underlying deep aquifers or reservoirs. Geodetic‐grade strainmeters were deployed at 30 m depth overlying the Bartlesville Formation, a 500‐m‐deep sandstone near Tulsa, OK. The strainmeters are 220 m east of injection well 9A completed in a permeable lens at the base of the Bartlesville Formation. Water was injected into well 9A at approximately 1.0 L/s during four tests that ranged in duration from a few hours to a few weeks. The horizontal strain increased (tension) and the circumferential strain was a few times larger than the radial strain. The vertical strain decreased (compression) during injection. Strain rates were approximately 100 nε/day during the first few hours, but the rates decreased and were approximately 10 nε/day during most of the tests. Four independent methods of poroelastic simulation and inversion predict reservoir properties and geometries that are similar to each other and consistent with independent information about the reservoir. All strain interpretations predict that a boundary to the permeable lens occurs beneath the vicinity of the strainmeters, which is consistent with core data from the site. The boundary of the permeable lens is located by matching the vertical, radial and circumferential strains, which demonstrates the value of measuring the strain tensor.

Murdoch, Lawrence C.↗

Experimental and Numerical Evaluation of the Thermal-Fluid Characteristics of the Helium-Cooled Modular Divertor with Multiple Jets Using a Reversed Heat Flux Approach

A single-finger unit of the Helium-Cooled Modular Divertor with Multiple Jets (HEMJ) with a plasma-facing surface (PFS) area of about 2 cm 2 has been studied in a helium (He) loop at He mass flow rates m˙ H ≤ 8 g/s and nearly prototypical conditions. Based on previous studies of the single finger of the HEMJ, our Georgia Institute of Technology group is planning to experimentally study larger divertors. Given that the HEMJ test section was heated with an induction heater and that it is impractical to scale this up to divertors with larger PFS areas, a reversed heat flux approach is being considered to measure heat transfer coefficients (HTCs). In this approach, the direction of the heat flux is reversed with water cooling and high-temperature He heating of the outer shell attached to the PFS. This work presents an initial experimental and numerical evaluation of this approach for a single HEMJ finger. Experiments with brass and copper-chromium-zirconium outer shells were conducted at dimensionless He mass flow rates or Reynolds numbers Re = 1 × 10 4 to 4.7 × 10 4 , an inlet pressure of 10 MPa, temperatures as great as 673 K, and maximum heat flux of 8.4 MW/m 2 . The experiments verify that the He-side HTCs are independent of the direction of the heat flux. Here, the results agree well with previous Nusselt number correlation and pressure loss coefficients for the HEMJ obtained using the normal heating approach.

42 ENGINEERING↗

FY22 Progress on Multicontinuum Methods in Containment

Estimation of two-phase fluid flow properties is important to understand and predict water and gas movement through the vadose zone for agricultural, hydrogeological, and engineering applications, such as containment transport and/or containment of gases in the subsurface. To estimate rock fluid flow properties and subsequently predict physically realistic processes such as patterns and timing of water, gas, and energy (e.g., heat) movement in the subsurface, laboratory spontaneous water imbibition with simultaneous temperature measurement and numerical modeling methods are presented in the FY22 progress report. A multiple-overlapping-continua conceptual model is used to explain and predict observed complex multi-phenomenological laboratory test behavior during spontaneous imbibition experiments. This report primarily addresses two complexities that arise during the experiments: 1) capturing the late-time behavior of spontaneous imbibition tests with dual porosity; and 2) understanding the thermal perturbation observed at or ahead of the imbibing wetting front, which are associated with adsorption of water in initially dry samples. We use numerical approaches to explore some of these issues, but also lay out a plan for further laboratory experimentation and modeling to best understand and leverage these unique observations.

58 GEOSCIENCES↗

Defining the Prototype Convenience Store Building Characteristics

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 30 prototype building models (20 different building types), which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). This report documents the building and system characteristics of the prototype convenience store building model. Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype convenience store building characteristics, and a one-story, 3,000 ft 2 building was considered as the prototype convenience store to represent an average-sized convenience store in the United States. The Oak Ridge National Laboratory team defined the operational hours of the convenience store as 17 hours per day. The types of exterior walls, roof, and floor were defined as brick wall, metal surfacing roof, and slab-on-grade floor, respectively. Double glazing was selected, and the window-towall ratio was set as 15% on the front side. For the system part, packaged system and centralized water heater were selected for the space heating and cooling system and water heater system, respectively. In terms of the refrigerator system, the number of refrigerators and freezers were determined as eight closed cases and two walk-in units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance and flexibility improvements of Staged Pressurized Oxy-Combustion

Staged Pressurized Oxy-Combustion (SPOC) is a low-carbon coal combustion power technology being developed by Washington University in St. Louis (WUSTL). Oxy-combustion plants enable straightforward capture of carbon dioxide (CO 2 ) by removing most of the nitrogen in the combustion air prior to use, thereby burning fuel in near-pure oxygen instead of air, producing a flue gas containing primarily CO 2 and water. CO 2 capture at amounts > 90% is possible, often using cryogenic air separation. Oxy-combustion typically relies on flue gas recycle (FGR) to reduce the peak temperature and radiation that would otherwise occur in a fuel/oxygen only flame. SPOC reduces the peak temperatures of combustion by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given furnace module. This means that the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. Also, the process operates at an elevated gas-side pressure, reducing boiler size, enhancing heat transfer to achieve a compact boiler configuration as compared to an atmospheric-pressure boiler design, and allowing for recovery of the latent heat of the water from the flue gas at a temperature useful to the steam cycle. The resultant net efficiency of the system is over 3 percentage points greater than traditional atmospheric-pressure oxy-combustion, and 7 percentage points greater than the post combustion variant, representing a step-change improvement over first-generation capture technologies. To further develop the concept, WUSTL and the Electric Power Research Institute, Inc., organized a project with American Air Liquide, Inc., Doosan Babcock Limited, and the U.S. Department of Energy to investigate a practicable and workable boiler design. The team has identified the potential for enhanced process flexibility for controlling power generation over a wider load range than is normally available to conventional coal-fired power plants due to the staged nature of the heat release. With increasing intermittent renewable generator contribution, on-demand generators need to be highly flexible to participate in the future energy market, requiring extensive operation at reduced load. Conventional coal-fired steam generators typically face challenges in maintaining temperature control of the reheat steam and main steam at reduced loads. This results in inefficient operation, both in terms of the boiler efficiency and steam turbine heat rate. The results of this project show the SPOC process is capable of exceptional turndown, both on a stage basis and with the ability to bypass entire stages. Oxygen-supply flexibility was also investigated, as this is also a key consideration for the overall flexibility of the SPOC process given the operating constraints of conventional air separation units. A boiler design concept assessment was conducted and was focused on delivering compact and constructible design. The assessment checked appropriate tube operating metal temperatures at full load and at lower operating loads, balanced against the needs of efficient coal combustion, and the resultant slagging and ash environments. Combustion testing in the 100-kWth pressurized combustion test rig at WUSTL was carried out to validate the combustion, heat flux profiles and burnout at multiple loads. Combustion parameters investigated were flame stability, fuel burnout, ash composition, radiative heat flux, and temperature profiles. The results of these tests formed the basis of a full-scale boiler design that will encompass improvements in both efficiency and flexibility over conventional oxy-combustion processes. The air separation unit flexibility was investigated, and associated cost implications were addressed. Detailed economic assessment results for a 550 MWe net power block are also provided, allowing for a comparison against the baseline NETL oxy-combustion and post combustion capture cases.

20 FOSSIL-FUELED POWER PLANTS↗

Newberry SHR Demonstration Project – Bipartisan Infrastructure Law Enhanced Geothermal (EGS) Pilot Demonstration (Abstract)

This project will create an Engineered Geothermal System (EGS) comprising two or more wells drilled to a depth of 4.25 km into superhot rock (SHR) with a temperature of 425 °C at Newberry Volcano in Central Oregon. An EGS is a manufactured heat exchanger in which water is injected in a deep injection well, or injector, to extract heat from the hot rock at depth and steam is returned to the surface in a production well, or producer, to generate electricity. In this project, the SHR EGS will be made using new methods and technologies to stimulate and connect hydraulic and natural fractures to enable multiple flow pathways between wells, allowing for optimal heat mining from the reservoir rock. The new technologies are designed to operate at rock temperatures much higher than those encountered in traditional geothermal. Following EGS completion, water will be injected into the injector well and steam extracted from the producer well in a long-term connectivity flow test demonstrating SHR reservoir evolution with time and use. Success will be measured by demonstrating the efficacy of new technologies and by producing economic quantities of steam (>40 MWth).

15 GEOTHERMAL ENERGY↗

Role of Intense Arctic Storm in Accelerating Summer Sea Ice Melt: An In Situ Observational Study

Abstract Intense storms have been more frequently observed in the Arctic during recent years, in coincidence with extreme sea ice loss events. However, it is still not fully understood how storms drive such events due to deficient observations and modeling discrepancies. Here we address this problem by analyzing in situ observations acquired during an Arctic expedition, which uniquely captured an intense storm in summer 2016. The result shows a pronounced acceleration of sea ice loss during the storm process. Diagnostic analysis indicates a net energy loss at the ice surface, not supporting the accelerated melting. Although the open water surface gained net heat energy, it was insufficient to increase the mixed‐layer temperature to the observed values. Dynamic analysis suggests that storm‐driven increase in ocean mixing and upward Ekman pumping of the Pacific‐origin warm water tremendously increased oceanic heat flux. The thermal advection by the Ekman pumping led to a warmed mixed layer by 0.05°C–0.12°C and, in consequence, an increased basal sea ice melt rate by 0.1–1.7 cm day −1 .

58 GEOSCIENCES↗

Design, optimization, and validation of a triply periodic minimal surface based heat exchanger for extreme temperature applications

Heat exchanger (HX) innovation offers potential for significant improvements in energy efficiency for a host of applications including but not limited to aviation and power generation cycles. Triply Periodic Minimal Surfaces (TPMS) have received significant attention in recent years due to their incredibly high surface area density, which makes them very attractive from a heat transfer point of view. Recent efforts have largely focused on thermal-hydraulic characterization of the many available TPMS and the testing of small-scale HX prototypes. However, practical implementation remains largely unexplored, partially due to the extreme computational cost associated with accurately simulating these complex structures. In this work, we present the design, simulation, and optimization of a TPMS-HX for high temperature (900 °C) and pressure (25 MPa) applications. Detailed analysis of HX sub-sections is conducted to define the smallest repeatable section which may be used to characterize the thermal-hydraulic performance of the entire HX, enabling rapid design and iteration with significantly reduced computational cost. Compared to preliminary results for a water-to-water experiment, calibrated heat transfer and pressure drop predictions were within ±5 % and ±10 %, respectively. Optimization results show a 10x increase in volumetric power density over the initial design, which is verified against a parametric exhaustive search of the HX design space. Furthermore, it was found that reducing the unit cell hydraulic diameter cell plays the largest role in increasing heat transfer, increasing the surface area density and enabling a more compact and efficient HX.

42 ENGINEERING↗