Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Tomo2Mesh: Fast Reconstruction and Visualization of Tomography Data in Mesh Format

Tomo2Mesh is an open-source project targeted towards real-time reconstruction, segmentation, and visualization of computed tomography (CT) data in mesh format. The CT reconstruction scheme is based on filtered back-projection of voxel subsets. The segmentation scheme uses a 3D convolutional neural network. To allow for fast, real-time reconstruction, voxel subsets are first identified by coarse reconstruction. The detail in specific regions of interest is improved through full reconstruction of voxel subsets in that region. Data structures are implemented to store and process voxel subsets. Finally, voxel data is labeled using connected components to detect disconnected regions such as voids whose morphological attributes (e.g., Feret diameter, principal axis orientation, local number density, size, etc.) can be measured also in real-time. Finally, a fast marching cubes implementation processes labeled voxel data into a triangular face mesh (vertices and faces) in .ply format for visualization in Paraview or other mesh visualization tools. The code provides a simple programming interface for detecting, classifying, and visualizing regions of interest based on morphology. For example, detected voids can be classified as round pores or extended cracks. Highly porous neighborhoods can be identified based on local number density. The mesh texture (or color) is assigned based these morphological attributes to allow smart visualization scenarios in real-time (e.g., show only long cracks). At the time of first release (July 2022), extraction of face mesh for visualization for raw CT data from a 2 megapixel camera would take between 1-5 minutes for most scenarios.

TEKAWADE, ANIKET↗

Solving disorder in (3D) real space: a comparative study of the three-dimensional difference pair distribution function and atomic resolution holography reconstructions

The quantitative analysis of local ordering principles in disordered crystalline systems has gained much attention over the past few years, as it is often considered crucial for optimizing material functionality. This development has been driven by significant advancements in computational and experimental methods, which have led to the establishment and widespread use of various analytical techniques. In this study, we perform model calculations to compare the effectiveness of atomic resolution holography and three-dimensional difference pair distribution function analysis (3D-ΔPDF). Using Cu 3 Au as a model system, we demonstrate an approach to derive local order parameters quantitatively and show that both techniques are well suited to quantifying chemical short-range order correlations and local bond-distance variations. By evaluating the strengths and limitations of both techniques, we advocate for their combined use to solve complex short-range order problems accurately.

3D-ΔPDF↗

Web-based Preprocessing and Visualization of 3D FIB Tomography Data for Nuclear Fuel Characterization

Three-dimensional (3D) focused ion beam (FIB) tomography enables reconstruction of internal nuclear fuel features that can't be fully evaluated through surface imaging alone. This capability supports characterization of fuel constituents and defects under thermal and irradiation conditions relevant to microreactor development. However, large tomography datasets can create data-handling, loading, and visualization challenges, especially when image-stack preparation and file conversion must be completed with separate tools. The Computational Ultraspatial Tomography Toolkit for High-Resolution Object Analysis Tools (CUTTRHOAT) is an open-source web application being developed to display FIB tomography datasets available through the Nuclear Research Data System (NRDS). The current alpha version requires prepared HDF5 datasets and has limited integrated data-preparation capabilities. This project improves CUTTHROAT by adding dataset-folder selection, automatic input detection, dataset scanning, missing-slice identification, blank-slice insertion, and image-stack-to-HDF5 conversion. Two applications will be compared: the baseline CUTTHROAT alpha workflow and the updated application containing the integrated data-handling and preprocessing functions. Evaluation will consider dataset detection accuracy, conversion success, loading time, rendering responsiveness, application stability, and user interaction. Preliminary results demonstrate successful loading of existing HDF5 files and converted image stacks, while testing also identified performance reductions caused by excessive blank-slice generation. The updated workflow reduces reliance on external preparation tools and supports more direct movement from image stacks to color-code 3D visualization. Future work includes refining missing-slice handling, integrating additional preprocessing functions, like a denoising feature, parsing TIFF metadata for automatic voxel scaling, and adding manual X, Y, and Z voxel-spacing inputs for PNG and JPEG.

36 - MATERIALS SCIENCE↗

Two-color pyrometry based flame to fuel surface radiative heat flux diagnostic using flamelets

In this study, a non-intrusive two-color pyrometry based radiative heat flux diagnostic is presented that accounts for the self-absorption effects. This diagnostic relies on looking up the flame temperature and soot volume fraction using the ratio of color intensities obtained from digital cameras and numerical solutions of 1D steady-state diffusion flames. Virtual two color pyrometry of computed flame show a unique one-to-one mapping of strained flames with intensity ratio; thereby allowing flames to be indexed and creation of a two-color flamelet manifold (TCFM). The TCFM is a function of two variables; the ratio of red to green intensities (flame index) and physical distance to the stoichiometric surface defined using a level-set function. The developed diagnostic is used in upward flame spread experiments where an approximate flame hull reconstruction method is applied to provide the 3D level-set function and intensity ratio for use of TCFM to provide radiative absorption properties for 3D ray tracing. Accounting for self- absorption effects provide improved soot volume fraction estimates. In conclusion, the radiative heat flux estimates are found to be in very good agreement with literature and improved results are obtained near the flame base.

42 ENGINEERING↗

The cosmic DANCe of Perseus

Context. Star-forming regions are excellent benchmarks for testing and validating theories of star formation and stellar evolution. The Perseus star-forming region, being one of the youngest (< 10 Myr), closest (280-320 pc), and most studied in the literature, is a fundamental benchmark. Aims. We aim to study the membership, phase-space structure, mass, and energy (kinetic plus potential) distribution of the Perseus star-forming region using public catalogues (Gaia, APOGEE, 2MASS, and Pan-STARRS). Methods. We used Bayesian methodologies that account for extinction to identify the Perseus physical groups in the phase-space, retrieve their candidate members, derive their properties (age, mass, 3D positions, 3D velocities, and energy), and attempt to reconstruct their origin. Results. We identify 1052 candidate members in seven physical groups (one of them new) with ages between 3 and 10 Myr, dynamical super-virial states, and large fractions of energetically unbounded stars. Their mass distributions are broadly compatible with that of Chabrier for masses ≳0.1 M ⊙ and do not show hints of over-abundance of low-mass stars in NGC 1333 with respect to IC 348. These groups’ ages, spatial structure, and kinematics are compatible with at least three generations of stars. Future work is still needed to clarify if the formation of the youngest was triggered by the oldest. Conclusions. The exquisite Gaia data complemented with public archives and mined with comprehensive Bayesian methodologies allow us to identify 31% more members than previous studies, discover a new physical group (Gorgophone: 7 Myr, 191 members, and 145 M ⊙ ), and confirm that the spatial, kinematic, and energy distributions of these groups support the hierarchical star formation scenario.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DLSIA: Deep Learning for Scientific Image Analysis

DLSIA (Deep Learning for Scientific Image Analysis) is a Python-based machine learning library that empowers scientists and researchers across diverse scientific domains with a range of customizable convolutional neural network (CNN) architectures for a wide variety of tasks in image analysis to be used in downstream data processing. DLSIA features easy-to-use architectures, such as autoencoders, tunable U-Nets and parameter-lean mixed-scale dense networks (MSDNets). Additionally, this article introduces sparse mixed-scale networks (SMSNets), generated using random graphs, sparse connections and dilated convolutions connecting different length scales. For verification, several DLSIA-instantiated networks and training scripts are employed in multiple applications, including inpainting for X-ray scattering data using U-Nets and MSDNets, segmenting 3D fibers in X-ray tomographic reconstructions of concrete using an ensemble of SMSNets, and leveraging autoencoder latent spaces for data compression and clustering. As experimental data continue to grow in scale and complexity, DLSIA provides accessible CNN construction and abstracts CNN complexities, allowing scientists to tailor their machine learning approaches, accelerate discoveries, foster interdisciplinary collaboration and advance research in scientific image analysis.

97 MATHEMATICS AND COMPUTING↗

Linking Domain Structure Evolution at a Grain Boundary to Piezoelectric Response via Nano‐Diffraction

Electric-field-induced domain structure switching in a 1 𝜇⁢m -thick Pb 0.99 (Zr 0.45 Ti 0.55 ) 0.98 Nb 0.02 O 3 (Nb-doped PZT) bicrystal film was characterized in situ via nano-focused synchrotron diffraction. The epitaxial film was deposited on a (100) SrTiO 3 bicrystal substrate. The changes in domain structure were mapped within a 5 𝜇⁢m × 5 𝜇⁢m area at and around an in-plane tilt-type (23.6°) grain boundary with 50 nm spatial resolution. Rocking curves collected at each point of the mapped area provided the ability to reconstruct spatially-varying three-dimensional (3D) reciprocal space maps around the grain boundary. The 3D reciprocal space maps reveal how different tilted 𝑎 -type domain variants interact with the grain boundary as a function of increasing electric field. Initially, a subset of 𝑎 -type domain variants with their polarization vectors largely orthogonal to the grain boundary were found in greater abundance within 570 nm of the grain boundary, possibly due to X-ray beam-induced local increases in the electrical conductivity, but after the coercive field was exceeded, reconfiguration of the ferroelastic domains was observed. The spatially-varying reciprocal space maps also facilitated evaluation of the strain field across the mapped area, along with 𝑑 33,𝑓 . Significant spatial heterogeneity of strain and 𝑑 33,𝑓 are observed, especially at the coercive field, which was attributed to maintaining deformation compatibility and correlated ferroelastic switching.

36 MATERIALS SCIENCE↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

GRMHD and GRPIC Simulations

We have developed a new three-dimensional general relativistic magnetohydrodynamic (GRMHD) code by using a conservative, high-resolution shock-capturing scheme. The numerical fluxes are calculated using the HLL approximate Riemann solver scheme. The flux-interpolated constrained transport scheme is used to maintain a divergence-free magnetic field. We have performed various 1-dimensional test problems in both special and general relativity by using several reconstruction methods and found that the new 3D GRMHD code shows substantial improvements over our previous code. The simulation results show the jet formations from a geometrically thin accretion disk near a nonrotating and a rotating black hole. We will discuss the jet properties depended on the rotation of a black hole and the magnetic field configuration including issues for future research. A General Relativistic Particle-in-Cell Code (GRPIC) has been developed using the Kerr-Schild metric. The code includes kinetic effects, and is in accordance with GRMHD code. Since the gravitational force acting on particles is extreme near black holes, there are some difficulties in numerically describing these processes. The preliminary code consists of an accretion disk and free-falling corona. Results indicate that particles are ejected from the black hole. These results are consistent with other GRMHD simulations. The GRPIC simulation results will be presented, along with some remarks and future improvements. The emission is calculated from relativistic flows in black hole systems using a fully general relativistic radiative transfer formulation, with flow structures obtained by GRMHD simulations considering thermal free-free emission and thermal synchrotron emission. Bright filament-like features protrude (visually) from the accretion disk surface, which are enhancements of synchrotron emission where the magnetic field roughly aligns with the line-of-sight in the co-moving frame. The features move back and forth as the accretion flow evolves, but their visibility and morphology are robust. We would like to extend this research using GRPIC simulations and examine a possible new mechanism for certain X-ray quasi-periodic oscillations (QPOs) observed in blackhole X-ray binaries.

Nishikawa, K.-I.↗

Algorithm-Driven Advances for Scientific CT Instruments: From model-based to deep learning-based approaches

Multiscale 3D characterization is widely used by materials scientists to further their understanding of the relationships between microscopic structure and macroscopic function. Scientific computed tomography (SCT) instruments are one of the most popular choices for 3D nondestructive characterization of materials at length scales ranging from the angstrom scale to the micron scale. These instruments typically have a source of radiation (such as electrons, X-rays, or neutrons) that interacts with the sample to be studied and a detector assembly to capture the result of this interaction (see Figure 1 ). A collection of such high-resolution measurements is made by reorienting the sample, which is mounted on a specially designed stage/holder after which reconstruction algorithms are used to produce the final 3D volume of interest. The specific choice of which instrument to use depends on the desired resolution and properties of the materials being imaged. Additionally, the end goal of SCT scans includes determining the morphology, chemical composition, or dynamic behavior of materials when subjected to external stimuli. In summary, SCT instruments are powerful tools that enable 3D characterization across multiple length scales and play a critical role in furthering the understanding of the structure–function relationships of different materials.

42 ENGINEERING↗

Convolutional neural network based non-iterative reconstruction for accelerating neutron tomography *

Abstract Neutron computed tomography (NCT), a 3D non-destructive characterization technique, is carried out at nuclear reactor or spallation neutron source-based user facilities. Because neutrons are not severely attenuated by heavy elements and are sensitive to light elements like hydrogen, neutron radiography and computed tomography offer a complementary contrast to x-ray CT conducted at a synchrotron user facility. However, compared to synchrotron x-ray CT, the acquisition time for an NCT scan can be orders of magnitude higher due to lower source flux, low detector efficiency and the need to collect a large number of projection images for a high-quality reconstruction when using conventional algorithms. As a result of the long scan times for NCT, the number and type of experiments that can be conducted at a user facility is severely restricted. Recently, several deep convolutional neural network (DCNN) based algorithms have been introduced in the context of accelerating CT scans that can enable high quality reconstructions from sparse-view data. In this paper, we introduce DCNN algorithms to obtain high-quality reconstructions from sparse-view and low signal-to-noise ratio NCT data-sets thereby enabling accelerated scans. Our method is based on the supervised learning strategy of training a DCNN to map a low-quality reconstruction from sparse-view data to a higher quality reconstruction. Specifically, we evaluate the performance of two popular DCNN architectures—one based on using patches for training and the other on using the full images for training. We observe that both the DCNN architectures offer improvements in performance over classical multi-layer perceptron as well as conventional CT reconstruction algorithms. Our results illustrate that the DCNN can be a powerful tool to obtain high-quality NCT reconstructions from sparse-view data thereby enabling accelerated NCT scans for increasing user-facility throughput or enabling high-resolution time-resolved NCT scans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Developments to the Porous Microstructure Analysis (PuMA) Software

Introduction The Porous Microstructure Analysis (PuMA) software is an open source framework for image-based simulation, primarily used to determine effective properties based on material microstructure. PuMA was originally developed for the study of NASA thermal protection materials; however, many of the solvers in PuMA have applicability to a broad range of materials science applications. PuMA version 3.2 computes material surface area, pore diameters, effective thermal conductivity, continuum and rarefied tortuosity, and permeability. For anisotropic materials, PuMA can estimate material orientation and compute anisotropic thermal conductivity and elasticity. In this talk, a brief overview of the PuMA software and underlying methods will be presented, as well as some recent and ongoing developments, including the use of immersed boundary methods for image-based simulation and the development of a new weave segmentation tool, called TomoSAM. Cut-Cell method for heat and mass transfer For simulations on complex microstructures, traditional unstructured meshing techniques often prove to be difficult and time-intensive. Voxel-based solvers, which represent the surface as a staircase structure, are relatively simple to implement but can lose accuracy when feature resolution is poor. In this work, we present a novel 3D cut-cell method for solving the variable coefficient Poisson equation on complex microstructures, suitable for the determination of effective thermal conductivity or tortuosity of a material. The method uses a Marching Cubes/Marching Squares surface reconstruction to create cut-cells and determine geometric quantities. A flux-correction method is extended to 3D, with least squares gradient reconstruction, to solve for the boundary fluxes in the cut-cells. Verification cases show the solver achieves globally 2nd order accuracy on complex microstructures. TomoSAM TomoSAM, a module of the PuMA software, has been developed as a plugin for 3D Slicer, a software platform used for 3D image processing and visualization. It utilizes the Segment Anything Model (SAM), a deep learning model capable of identifying objects and generating image masks based on minimal user input. This feature enables efficient segmentation of complex 3D datasets, particularly of woven materials, from tomography or similar imaging methods, reducing the need for manual segmentation.

Tomography↗

Recent Developments to the Porous Microstructure Analysis (PuMA) Software

The Porous Microstructure Analysis (PuMA) software is an open source framework for image-based simulation, primarily used to determine effective properties based on material microstructure. PuMA was originally developed for the study of NASA thermal protection materials; however, many of the solvers in PuMA have applicability to a broad range of materials science applications. PuMA version 3.2 computes material surface area, pore diameters, effective thermal conductivity, continuum and rarefied tortuosity, and permeability. For anisotropic materials, PuMA can estimate material orientation and compute anisotropic thermal conductivity and elasticity. In this talk, a brief overview of the PuMA software and underlying methods will be presented, as well as some recent and ongoing developments, including the use of immersed boundary methods for image-based simulation and the development of a new weave segmentation tool, called TomoSAM. Cut-Cell method for heat and mass transfer For simulations on complex microstructures, traditional unstructured meshing techniques often prove to be difficult and time-intensive. Voxel-based solvers, which represent the surface as a staircase structure, are relatively simple to implement but can lose accuracy when feature resolution is poor. In this work, we present a novel 3D cut-cell method for solving the variable coefficient Poisson equation on complex microstructures, suitable for the determination of effective thermal conductivity or tortuosity of a material. The method uses a Marching Cubes/Marching Squares surface reconstruction to create cut-cells and determine geometric quantities. A flux-correction method is extended to 3D, with least squares gradient reconstruction, to solve for the boundary fluxes in the cut-cells. Verification cases show the solver achieves globally 2nd order accuracy on complex microstructures. TomoSAM TomoSAM, a module of the PuMA software, has been developed as a plugin for 3D Slicer, a software platform used for 3D image processing and visualization. It utilizes the Segment Anything Model (SAM), a deep learning model capable of identifying objects and generating image masks based on minimal user input. This feature enables efficient segmentation of complex 3D datasets, particularly of woven materials, from tomography or similar imaging methods, reducing the need for manual segmentation.

Tomography↗

Imaging mechanism for hyperspectral scanning probe microscopy via Gaussian process modelling

We investigate the ability to reconstruct and derive spatial structure from sparsely sampled 3D piezoresponse force microcopy data, captured using the band-excitation (BE) technique, via Gaussian Process (GP) methods. Even for weakly informative priors, GP methods allow unambiguous determination of the characteristic length scales of the imaging process both in spatial and frequency domains. We further show that BE data set tends to be oversampled in the spatial domains, with ~30% of original data set sufficient for high-quality reconstruction, potentially enabling faster BE imaging. At the same time, reliable reconstruction along the frequency domain requires the resonance peak to be within the measured band. This behavior suggests the optimal strategy for the BE imaging on unknown samples. Finally, we discuss how GP can be used for automated experimentation in SPM, by combining GP regression with non-rectangular scans.

47 OTHER INSTRUMENTATION↗

SDSS-IV MaNGA: 3D spin alignment of spiral and S0 galaxies

ABSTRACT We investigate the 3D spin alignment of galaxies with respect to the large-scale filaments using the MaNGA survey. The cosmic web is reconstructed from the Sloan Digital Sky Survey using disperse and the 3D spins of MaNGA galaxies are estimated using the thin disc approximation with integral field spectroscopy kinematics. Late-type spiral galaxies are found to have their spins parallel to the closest filament’s axis. The alignment signal is found to be dominated by low-mass spirals. Spins of S0-type galaxies tend to be oriented preferentially in perpendicular direction with respect to the filament’s axis. This orthogonal orientation is found to be dominated by S0s that show a notable misalignment between their kinematic components of stellar and ionized gas velocity fields and/or by low-mass S0s with lower rotation support compared to their high-mass counterparts. Qualitatively similar results are obtained when splitting galaxies based on the degree of ordered stellar rotation, such that galaxies with high spin magnitude have their spin aligned, and those with low spin magnitude in perpendicular direction to the filaments. In the context of conditional tidal torque theory, these findings suggest that galaxies’ spins retain memory of their larger scale environment. In agreement with measurements from hydrodynamical cosmological simulations, the measured signal at low redshift is weak, yet statistically significant. The dependence of the spin-filament orientation of galaxies on their stellar mass, morphology, and kinematics highlights the importance of sample selection to detect the signal.

Kraljic, Katarina↗

Model-based reconstruction for enhanced x-ray CT of dense tri-structural isotropic particles

Tri-structural isotropic (TRISO) fuel particles are a key component of next generation nuclear fuels. Using x-ray computed tomography (CT) to characterize TRISO particles is challenging because of the strong attenuation of the x-ray beam by the uranium core, leading to severe photon starvation in a substantial fraction of the measurements. Furthermore, the overall acquisition time for a high-resolution CT scan can be very long when using conventional laboratory-based x-ray systems and reconstruction algorithms. Specifically, when analytic methods such as the Feldkamp–Davis–Kress (FDK) algorithm are used for reconstruction, it results in severe streak artifacts and noise in the corresponding 3D volume, which makes subsequent analysis of the particles challenging. In this paper, we develop and apply model-based image reconstruction (MBIR) algorithms to improve the quality of CT reconstructions for TRISO particles to facilitate better characterization. We demonstrate that the proposed MBIR algorithms can significantly suppress artifacts with minimal pre-processing compared to conventional approaches. We also demonstrate that the proposed MBIR approach can obtain high-quality reconstruction compared to the FDK approach even when using a fraction of the typically acquired measurements, thereby enabling dramatically faster measurement times for TRISO particles.

Venkatakrishnan, Singanallur↗