Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FLOW - COMPRESSIBILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Lewis Research Center support of Chrysler upgraded engine program

Running of the upgraded engine has indicated that, although the engine is mechanically sound, it is deficient in power. Recent modifications and corrective action have improved this. Testing of the engine is being done in the test cell. This simulates an automobile installation. Located in the inlet flow ducts are two turbine flow meters to measure engine air flow.

Warren, E. L.↗

Containerless processing in the European microgravity programme

Reasonable acoustic levitation for undercooled melts in space was obtained, but some residual instabilities in times of high thermal transients need to be eliminated. Electrostatic levitation was developed with the acoustic levitator with similar applications in mind. The system tested used a tetrahedral electrode configuration with unchanged samples. ESA's involvement in electromagnetic levitation is concentrated on accommodation studies for the European Containerless Processing Lab for the Space Station Freedom. The gas film technique is based on the processing of samples confined by porous walls. Air flow through the walls create air cushions which inhibit wall contact. This technique is particularly promising for glasses.

Behrmann, P.↗

The NASA Glen Research Center's Hypersonic Tunnel Facility

The NASA Glenn Research Center's Hypersonic Tunnel Facility (HTF) is a blow-down, freejet wind tunnel that provides true enthalpy flight conditions for Mach numbers of 5, 6, and 7. The Hypersonic Tunnel Facility is unique due to its large scale and use of non-vitiated (clean air) flow. A 3MW graphite core storage heater is used to heat the test medium of gaseous nitrogen to the high stagnation temperatures required to produce true enthalpy conditions. Gaseous oxygen is mixed into the heated test flow to generate the true air simulation. The freejet test section is 1.07m (42 in.) in diameter and 4.3m (14 ft) in length. The facility is well suited for the testing of large scale airbreathing propulsion systems. In this chapter, a brief history and detailed description of the facility are presented along with a discussion of the facility's application towards hypersonic airbreathing propulsion testing.

Woike, Mark R.↗

Unsteady Flowfield Around Tandem Cylinders as Prototype for Component Interaction in Airframe Noise

Synergistic application of experiments and numerical simulations is crucial to understanding the underlying physics of airframe noise sources. The current effort is aimed at characterizing the details of the flow interaction between two cylinders in a tandem configuration. This setup is viewed to be representative of several component-level flow interactions that occur when air flows over the main landing gear of large civil transports. Interactions of this type are likely to have a significant impact on the noise radiation associated with the aircraft undercarriage. The paper is focused on two-dimensional, time-accurate flow simulations for the tandem cylinder configuration. Results of the unsteady Reynolds Averaged Navier-Stokes (URANS) computations with a two-equation turbulence model, at a Reynolds number of 0.166 million and a Mach number of 0.166, are presented. The experimental measurements of the same flow field are discussed in a separate paper by Jenkins, Khorrami, Choudhari, and McGinley (2005). Two distinct flow regimes of interest, associated with short and intermediate separation distances between the two cylinders, are considered. Emphasis is placed on understanding both time averaged and unsteady flow features between the two cylinders and in the wake of the rear cylinder. Predicted mean flow quantities and vortex shedding frequencies show reasonable agreement with the measured data for both cylinder spacings. Computations for short separation distance indicate decay of flow unsteadiness with time, which is not unphysical; however, the predicted sensitivity of mean lift coefficient to small angles of attack explains the asymmetric flowfield observed during the experiments.

Khorrami, Meldi R.↗

Stability and Control Analysis of the F-15B Quiet Spike Aircraft

The primary objective of the Quiet Spike flight research program was the aerodynamic and structural proof-of-concept of a telescoping, 24 ft, sonic-boom suppressing nose boom on a F-15B aircraft. The program goal was to collect flight data for model validation up to 1.8 Mach. In the area of stability and controls the primary concern was to assess the effect of the spike on the stability, controllability and handling qualities of the aircraft. The primary goal of this test philosophy was maintaining safety of flight. Two main issues are discussed in this paper: the stability and controls approach and analysis in the presence of uncertain spike influenced aerodynamics on the F-15B aircraft flight dynamics; and the analysis of F-15B flight dynamics implications due to spike induced air flow in the vicinity of air data and angle-of-attack sensors. Also addressed are flight test implications based on the analysis

McWherter, Shaun↗

Preliminary Tests of Nose- and Side- Entrance Blower Cooling Systems for Radial Engines, Special Report

Two cowling systems intended to reduce the drag and improve the low-speed cooling characteristics of conventional radial engine cowlings were tested in model form to determine the practicability of the methods. One cowling included a blower mounted on the rear face of a large propeller spinner which drew cooling air in through side entrance ducts located behind the equivalent engine orifice plate. The air was passed through the equivalent engine orifice plate from rear to front and out through a slot between the spinner and the engine plate. The blower produced substantially all the power necessary to circulate the cooling air in some cases, so the quantity of air flowing was independent of the air speed, Two types of blowers were used, a centrifugal type and one using airfoil blades which forced the air outward from the center of rotation. The other cowling was similar to the conventional N.A.C.A. cowling except for the addition of a large propeller spinner nose. The spinner was provided with a hole in the nose to admit cooling air and blower blades to increase the pressure for cooling at low speeds. The tests show that with both cowling types the basic drag of the nacelle was reduced substantially below that for the N.A.C.A. cowling by virtue of the better nose shape made possible by the spinner . The drag due to the side-entrance ducts was nearly zero when the openings were closed or when the blower was drawing in a certain quantity of air in proportion to the air speed. The drag increased, however, when air mas allowed to spill from the openings. The nose-entrance blower showed considerable promise as a cooling means although the blower tested was relatively inefficient, owing to the fact that the blower compartments evidently were expanded too rapidly under the conditions imposed. by the design.

Biermann, David↗

Direct Expansion Heat Pump Using High Glide Low GWP Refrigerant

Next generation of refrigerants require drastically lower global warming potential (GWP). The refrigerant mixtures, with a GWP < 150, e.g., R-457A, etc., tend to have significant temperature glide, which prefer multi-row, cross counter flow configuration. Typical heat pump operation reverses the refrigerant flow direction, compared to the air flow, from cooling mode to heating mode. It is difficult to configurate cross counter-flow heat exchangers in heat pumps. We invented an innovative configuration, having check valve assembly to maintain uniform cross counter flow configuration in both cooling and heat modes, which optimizes the performance of a high temperature slide refrigerant mixture, i.e. R-457A. Based on it, we developed a laboratory prototype, using a 2-stage compressor, achieved a cooling SEER (cooling seasonal energy efficiency rating) of 16.0 (cooling seasonal COP of 4.69) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP of 2.78). The unit was tested in an extensive ambient condition, heating operation from 5˚F to 62˚F (-15˚C to 16.7˚C); cooling operation from 82˚F to 95˚F (27.8˚C to 35˚C). The paper will introduce the system configuration, heat exchanger dimensions and laboratory investigations.

Shen, Bo↗

Characterizing NWP Model Errors Using Doppler-Lidar Measurements of Recurrent Regional Diurnal Flows: Marine-Air Intrusions into the Columbia-River Basin

Ground-based Doppler-lidar instrumentation provides atmospheric wind data at dramatically improved accuracies and spatial/temporal resolutions. These capabilities have provided new insights into atmospheric flow phenomena, but they also should have a strong role in NWP model improvement. Insight into the nature of model errors can be gained by studying recurrent atmospheric flows, here a regional summertime diurnal sea breeze and subsequent marine-air intrusion into the arid interior of Oregon-Washington, where these winds are an important windenergy resource. These marine intrusions were sampled by three scanning Doppler lidars in the Columbia-River Basin as part of the Second Wind Forecast Improvement Project (WFIP2), using data from summer 2016. Lidar time-height cross sections of wind speed identified eight days when the diurnal-flow cycle, (peak wind speeds at midnight, afternoon minima) was obvious and strong. Eight-day composite time-height cross sections of lidar wind speeds are used to validate those generated by the operational NCEP-HRRR model. HRRR simulated the diurnal wind cycle, but produced errors in the timing of onset and significant errors due to a premature nighttime demise of the intrusion flow, producing low-bias errors of 6 m s-1 . Day-to-day and in the composite, whenever a marine intrusion occurred, HRRR made these same errors. The errors occurred under a range of gradient wind conditions indicating that they resulted from the misrepresentation of physical processes within a limited region around the measurement locations. Because of their generation within a limited geographical area, field-measurement programs can be designed to find and address the sources of these NWP errors.

Banta, Robert M.↗

Hotel Room Computational Fluid Dynamics to Investigate Airborne Pathogen Dispersal Patterns

A hotel room unit consisting of a bedroom and bathroom was modelled using computational fluid dynamics (CFD) to investigate airborne pathogen dispersal patterns. The full-scale model includes a ‘typical’ hotel room configuration, furniture, and vents. The air sources and sinks include a bathroom vent, a heating, ventilation, and cooling (HVAC) unit located in the bedroom, and a ½” gap at the bottom of the entry door. In addition, the entry door and window can be opened or closed, as desired. Three key configuration simulations were conducted: 1) both the bathroom vent and HVAC were on, 2) only the HVAC was on, and 3) only the bathroom vent was on. If the HVAC air is from a fresh, clean source, or passes through a high-efficiency filter/UV device, then the first configuration is the safest, as contaminated air is highly reduced. The second configuration is also safe, but does not benefit from the outsourcing of potentially-infected air, such as contaminated air flowing through an ineffective filter. The third configuration should be avoided, as the bathroom vent causes air to flow from the hallway, which can be of dubious origin. The CFD simulations also showed that recirculation and swirling regions tend to accumulate the largest concentrations of heavier airborne particles, pathogens, dust, etc. These regions are associated with the largest turbulence kinetic energy (TKE) , and tend to occur in areas with flow recirculation and corners. Therefore, TKE presents a reasonable metric to guide the strategic location of pathogen mitigation devices. The simulations show complex flow patterns with distinct upper and lower flow regions, swirling flow, and significant levels of turbulent mixing. These simulations provide intriguing insights that can be applied to help mitigate pathogen aerosol dispersal, generate building design guidelines, as well as provide insights for the strategic placement of mitigation devices, such as ultraviolet (UV) light, supplemental fans, and filters.

54 ENVIRONMENTAL SCIENCES↗

Development of electrostatic precipitator (ESP) technology to remove elemental mercury vapor, HG(0)

The presence of mercury vapor or other forms of mercury presents issues with worker safety, decommissioning facilities, and environmental impacts. As such, it is desired to develop a strategy to either remove or reduce mercury levels in Oak Ridge’s Y-12 Complex facilities. A testing methodology was developed to evaluate electrostatic precipitator technology for removal of mercury vapor. This methodology involved supplying mercury vapor-containing air to the ESP device by flowing air through a column containing alternating layers of sand and liquid mercury droplets. Initial attempts at quantifying the efficacy of the ESP device in removing mercury vapor were plagued with difficulties in controlling the flow of mercury into the ESP device due to poor performance of the generator column and the contamination of these experiments with mercury from an unknown source. These issues were resolved by creating a new generator column with slower air velocity and higher surface area of liquid mercury, along with moving the air intake for the ESP device to outside of the chemical hood in which testing took place. This resulted in a steady, quantified flow of mercury vapor from the generator column and no observation of unintended mercury sources. A final test of the ESP device under these controlled conditions showed that for a certain amount of time (on the order of 20-30 minutes) mercury concentrations were reduced by approximately 33 - 67% of the inlet concentration. However, episodic releases or pulses of mercury observed only at the outlet indicated that the mercury accumulated in the ESP device is periodically expelled. As a result, it was not deemed to be an efficient strategy for the removal of elemental mercury vapor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Shock-Wave/Boundary-Layer Interactions in Hypersonic Low Density Flows

Results of numerical simulations of Mach 10 air flow over a hollow cylinder-flare and a double-cone are presented where viscous effects are significant. The flow phenomena include shock-shock and shock- boundary-layer interactions with accompanying flow separation, recirculation, and reattachment. The purpose of this study is to promote an understanding of the fundamental gas dynamics resulting from such complex interactions and to clarify the requirements for meaningful simulations of such flows when using the direct simulation Monte Carlo (DSMC) method. Particular emphasis is placed on the sensitivity of computed results to grid resolution. Comparisons of the DSMC results for the hollow cylinder-flare (30 deg.) configuration are made with the results of experimental measurements conducted in the ONERA RSCh wind tunnel for heating, pressure, and the extent of separation. Agreement between computations and measurements for various quantities is good except that for pressure. For the same flow conditions, the double- cone geometry (25 deg.- 65 deg.) produces much stronger interactions, and these interactions are investigated numerically using both DSMC and Navier-Stokes codes. For the double-cone computations, a two orders of magnitude variation in free-stream density (with Reynolds numbers from 247 to 24,7 19) is investigated using both computational methods. For this range of flow conditions, the computational results are in qualitative agreement for the extent of separation with the DSMC method always predicting a smaller separation region. Results from the Navier-Stokes calculations suggest that the flow for the highest density double-cone case may be unsteady; however, the DSMC solution does not show evidence of unsteadiness.

Moss, James N.↗

Development of the Dual Aerodynamic Nozzle Model for the NTF Semi-Span Model Support System

The recent addition of a dual flow air delivery system to the NASA Langley National Transonic Facility was experimentally validated with a Dual Aerodynamic Nozzle semi-span model. This model utilized two Stratford calibration nozzles to characterize the weight flow system of the air delivery system. The weight flow boundaries for the air delivery system were identified at mildly cryogenic conditions to be 0.1 to 23 lbm/sec for the high flow leg and 0.1 to 9 lbm/sec for the low flow leg. Results from this test verified system performance and identified problems with the weight-flow metering system that required the vortex flow meters to be replaced at the end of the test.

Jones, Greg S.↗

Turbulence measurements in hypersonic boundary layers using constant-temperature anemometry and Reynolds stress measurements in hypersonic boundary layers

The primary objective in the two research investigations performed under NASA Langley sponsorship (Turbulence measurements in hypersonic boundary layers using constant temperature anemometry and Reynolds stress measurements in hypersonic boundary layers) has been to increase the understanding of the physics of hypersonic turbulent boundary layers. The study began with an extension of constant-temperature thermal anemometry techniques to a Mach 11 helium flow, including careful examinations of hot-wire construction techniques, system response, and system calibration. This was followed by the application of these techniques to the exploration of a Mach 11 helium turbulent boundary layer (To approximately 290 K). The data that was acquired over the course of more than two years consists of instantaneous streamwise mass flux measurements at a frequency response of about 500 kHz. The data are of exceptional quality in both the time and frequency domain and possess a high degree of repeatability. The data analysis that has been performed to date has added significantly to the body of knowledge on hypersonic turbulence, and the data reduction is continuing. An attempt was then made to extend these thermal anemometry techniques to higher enthalpy flows, starting with a Mach 6 air flow with a stagnation temperature just above that needed to prevent liquefaction (To approximately 475 F). Conventional hot-wire anemometry proved to be inadequate for the selected high-temperature, high dynamic pressure flow, with frequent wire breakage and poor system frequency response. The use of hot-film anemometry has since been investigated for these higher-enthalpy, severe environment flows. The difficulty with using hot-film probes for dynamic (turbulence) measurements is associated with construction limitations and conduction of heat into the film substrate. Work continues under a NASA GSRP grant on the development of a hot film probe that overcomes these shortcomings for hypersonic flows. Each of the research tasks performed during the NASA Langley research grants is discussed separately below.

Spina, Eric F.↗

Flame spread across liquids

Recent reviews of our understanding of flame spread across liquids show that there are many unresolved issues regarding the phenomenology and causal mechanisms affecting ignition susceptibility, flame spread characteristics, and flame spread rates. One area of discrepancy is the effect of buoyancy in both the uniform and pulsating spread regimes. The approach we have taken to resolving the importance of buoyancy for these flames is: (1) normal gravity (1g) and microgravity (micro g) experiments; and (2) numerical modeling at different gravitational levels. Of special interest to this work, as discussed at the previous workshop, is the determination of whether, and under what conditions, pulsating spread occurs in micro g. Microgravity offers a unique ability to modify and control the gas-phase flow pattern by utilizing a forced air flow over the pool surface.

Ross, Howard D.↗

Airborne Instruments for the In Situ Detection of ClONO2, NO2, ClO, and BrO in the Stratosphere

Design and construction of an in situ sensor for the detection of stratospheric ClONO2, ClO, BrO, and NO2, was conceived as a two-year program. The experiment has two novel components: a resistive silicon thermal dissociation heater used to fragment ClONO2 into ClO and NO2 and a laser-induced fluorescence sensor for N02. These two new components are integrated into an experiment that uses technology developed in our labs for the ER-2 ClO and ER-2 HO(X) instruments. During the first year we reconstructed our laboratory prototypes for ClONO2 and NO2 detection and made substantial improvements in the calibration apparatus. Results from these laboratory experiments have been used to refine the design of the flight instrument. During this year we began the design of all of the long-lead items required to produce a flight instrument: including the design and fabrication of the air flow system used to direct stratospheric air to our halogen sensors, design and prototyping of an aircraft-compatible thermal dissociation heater, and development and test of a new high powered laser system. Finally, we have designed and released for fabrication several subsystems.

Anderson, James G.↗

Trash to Gas: Converting Space Waste into Useful Supply Products

The cost of sending mass into space with current propulsion technology is very expensive, making every item a crucial element of the space mission. It is essential that all materials be used to their fullest potential. Items like food, packaging, clothing, paper towels, gloves, etc., normally become trash and take up space after use. These waste materials are currently either burned up upon reentry in earth's atmosphere or sent on cargo return vehicles back to earth: a very wasteful method. The purpose of this project was to utilize these materials and create useful products like water and methane gas, which is used for rocket fuel, to further supply a deep space mission. The system used was a thermal degradation reactor with the configuration of a down-draft gasifier. The reactor was loaded with approximately 100g of trash simulant and heated with two external ceramic heaters with separate temperature control in order to create pyrolysis and gasification in one zone and incineration iri a second zone simultaneously. Trash was loaded into the top half of the reactor to undergo pyrolysis while the downdraft gas experienced gasification or incineration to treat tars and maximize the production of carbon dioxide. Minor products included carbon monoxide, methane, and other hydrocarbons. The carbon dioxide produced can be sent to a Sabatier reactor to convert the gas into methane, which can be used as rocket propellant. In order to maximize the carbon dioxide and useful gases produced, and minimize the unwanted tars and leftover ashen material, multiple experiments were performed with altered parameters such as differing temperatures, flow rates, and location of inlet air flow. According to the data received from these experiments, the process will be further scaled up and optimized to ultimately create a system that reduces trash buildup while at the same time providing enough useful gases to potentially fill a methane tank that could fuel a lunar ascent vehicle or other deep space mission.

Tsoras, Alexandra↗

A Capillary-Based Static Phase Separator for Highly Variable Wetting Conditions

The invention, a static phase separator (SPS), uses airflow and capillary wetting characteristics to passively separate a two-phase (liquid and air) flow. The device accommodates highly variable liquid wetting characteristics. The resultant design allows for a range of wetting properties from about 0 to over 90 advancing contact angle, with frequent complete separation of liquid from gas observed when using appropriately scaled test conditions. Additionally, the design accommodates a range of air-to-liquid flow-rate ratios from only liquid flow to over 200:1 air-to-liquid flow rate. The SPS uses a helix input section with an ice-cream-cone-shaped constant area cross section (see figure). The wedge portion of the cross section is on the outer edge of the helix, and collects the liquid via centripetal acceleration. The helix then passes into an increasing cross-sectional area vane region. The liquid in the helix wedge is directed into the top of capillary wedges in the liquid containment section. The transition from diffuser to containment section includes a 90 change in capillary pumping direction, while maintaining inertial direction. This serves to impinge the liquid into the two off-center symmetrical vanes by the airflow. Rather than the airflow serving to shear liquid away from the capillary vanes, the design allows for further penetration of the liquid into the vanes by the air shear. This is also assisted by locating the air exit ports downstream of the liquid drain port. Additionally, any droplets not contained in the capillary vanes are re-entrained downstream by a third opposing capillary vane, which directs liquid back toward the liquid drain port. Finally, the dual air exit ports serve to slow the airflow down, and to reduce the likelihood of shear. The ports are stove-piped into the cavity to form an unfriendly capillary surface for a wetting fluid to carryover. The liquid drain port is located at the start of the containment region, allowing for draining the bulk fluid in a continuous circuit. The functional operation of the SPS involves introducing liquid flow (from a human body, a syringe, or other source) to the two-phase inlet while an air fan pulls on the air exit lines. The fan is operated until the liquid is fully introduced. The system is drained by negative pressure on the liquid drain lines when the SPS containment system is full.

Thomas, Evan A.↗