Search NASA⌕ Search

SEARCH · Search NASA

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

TU-H-CAMPUS-JeP1-04: Deformable Image Registration Performances in Pelvis Patients: Impact of CBCT Image Quality

Purpose: To investigate the accuracy and robustness, against image noise and artifacts (typical of CBCT images), of a commercial algorithm for deformable image registration (DIR), to propagate regions of interest (ROIs) in computational phantoms based on real prostate patient images. Methods: The Anaconda DIR algorithm, implemented in RayStation was tested. Two specific Deformation Vector Fields (DVFs) were applied to the reference data set (CTref) using the ImSimQA software, obtaining two deformed CTs. For each dataset twenty-four different level of noise and/or capping artifacts were applied to simulate CBCT images. DIR was performed between CTref and each deformed CTs and CBCTs. In order to investigate the relationship between image quality parameters and the DIR results (expressed by a logit transform of the Dice Index) a bilinear regression was defined. Results: More than 550 DIR-mapped ROIs were analyzed. The Statistical analysis states that deformation strenght and artifacts were significant prognostic factors of DIR performances, while noise appeared to have a minor role in DIR process as implemented in RayStation as expected by the image similarity metric built in the registration algorithm. Capping artifacts reveals a determinant role for the accuracy of DIR results. Two optimal values for capping artifacts were found to obtain acceptable DIR results (DICE> 075/ 0.85). Various clinical CBCT acquisition protocol were reported to evaluate the significance of the study. Conclusion: This work illustrates the impact of image quality on DIR performance. Clinical issues like Adaptive Radiation Therapy (ART) and Dose Accumulation need accurate and robust DIR software. The RayStation DIR algorithm resulted robust against noise, but sensitive to image artifacts. This result highlights the need of robustness quality assurance against image noise and artifacts in the commissioning of a DIR commercial system and underlines the importance to adopt optimized protocols for CBCT image acquisitions in ART clinical implementation.

60 APPLIED LIFE SCIENCES↗

Curation of Federally Owned Archeological Collections at NASA Langley Research Center

As a Federal agency, NASA has a moral and legal obligation to the public to manage the archeological heritage resources under its control. Archeological sites are unique, nonrenewable resources that must be preserved so that future generations may experience and interpret the material remains of the past. These sites are protected by a wide array of federal regulations. These regulations are intended to ensure that our nation's cultural heritage is preserved for the study and enjoyment of future generations. Once a site has been excavated, all that remains of it are the artifacts and associated records which, taken together, allow researchers to reconstruct the past. With the contextual information provided by associated records such as field notes, maps and photographs, archeological collections can provide important information about life in the past. An integral component of the federal archeology program is the curation of these databases so that qualified scholars will have access to them in years to come. Standards for the maintenance of archeological collections have been codified by various professional organizations and by the federal government. These guidelines focus on providing secure, climate-controlled archival storage conditions for the collections and an adequate study area in which researchers can examine the artifacts and documents. In the 1970's and early 1980's, a group of NASA employees formed the LRC Historical and Archeological Society (LRCHAS) in order to pursue studies of the colonial plantations that ha been displaced by Langley Research Center (LaRC). They collected data on family histories and land ownership as well as conducting archeological surveys and excavations at two important 17th-20th century plantation sites in LaRC, Cloverdale and Chesterville. The excavations produced a wealth of information in the form of artifacts, photographs, maps and other documents. Unfortunately, interest on the part of the LRCHAS membership waned before a report was written, and since 1982 the artifacts have moldered in a flimsy trailer with no climate controls, which had once served as a field laboratory but which threatened to become a tomb for the collection. A recent analysis of Langley's cultural resources by Gray & Pape, Inc. recommended that the collection be organized, cataloged, and placed in a proper curation facility in accordance with Federal regulations. The project for the LARSS program was to research curation standards, organize the collection, catalog it, and prepare it for transfer to a facility which could provide adequate long-term curation conditions for the artifacts and documents. The first phase was to organize the artifacts, which were lying about the lab in various stages of cleaning, analysis, and conservation. Once all of the artifacts from the various excavation units and levels had been regrouped, they were cleaned and/or repackaged in archivally-stable materials. A basic catalog was prepared which will provide interested parties with a rough idea of what we have and where it can be found. Another aspect of the project was to organize the records left by the LRCHAS. Bundles of papers, photographs, and field data found in every corner and drawer of the laboratory trailer were put into order and, where appropriate, copies were made on acid-free Permabond paper for long term storage. Finally, the entire collection and most of the lab equipment was transferred into a secure, climate controlled room which will serve as an archive and study space for qualified scholars interested in exploring LaRC's rich historical heritage.

Eastman, John Arnold↗

Memory forensic analysis of a programmable logic controller in industrial control systems

In industrial control systems (ICS), programmable logic controllers (PLCs) are used to automate physical processes such as nuclear plants and power grid stations, and are often subject to cyber attacks. As in conventional IT domain, the memory analysis of the PLCs can help answer important forensic questions about the attack, such as the presence of malicious firmware, injection of modified control logic (the program running on the PLC), and manipulation of I/O devices (e.g., sensors and actuators). Unlike conventional IT domain, PLCs have heterogeneous hardware architecture, proprietary firmware and control software, making it challenging to employ a unified framework for their memory forensics. For merely extracting artifacts of forensic importance, reverse-engineering the firmware is a tedious task, and the effort needs to be repeated for every PLC model. As a community, a step-wise approach to tackle this challenge is to analyze the memory of specific PLCs, and subsequently find a generic framework applicable to all PLCs. Our work is a step forward in this direction. By following a methodology that focuses on the functional layer of PLCs instead of reverse engineering the firmware, we analyze the digital forensic artifacts available in a common PLC, Allen-Bradley ControlLogix 1756-L61. Before diving into the memory dump, we analyze the PLC control software to create a list of important artifacts that are sure to exist in the PLC memory dump. The approach employs a setup where PLC control software RSLogix-5000 is connected to the PLC, and the memory dump can be obtained as and when needed. We create test cases that sequentially highlight each category of artifacts, followed by an examination of the resultant impact on memory. After attaining the listed artifacts, we employ conventional string and known data searches to extract interesting information present in this PLC's memory. The memory analysis profile, presented as a Python library and shared with the community, can help a forensic investigator to readily extract forensic artifacts from the same model's controller. The adopted approach may help researchers in creating memory profile of other PLCs, and ultimately formulating a generic PLC memory analysis framework.

Rais, Muhammad Haris↗

Considerations for three-dimensional image reconstruction from experimental data in coherent diffractive imaging

Diffraction before destruction using X-ray free-electron lasers (XFELs) has the potential to determine radiation-damage-free structures without the need for crystallization. This article presents the three-dimensional reconstruction of the Melbournevirus from single-particle X-ray diffraction patterns collected at the LINAC Coherent Light Source (LCLS) as well as reconstructions from simulated data exploring the consequences of different kinds of experimental sources of noise. The reconstruction from experimental data suffers from a strong artifact in the center of the particle. This could be reproduced with simulated data by adding experimental background to the diffraction patterns. In those simulations, the relative density of the artifact increases linearly with background strength. This suggests that the artifact originates from the Fourier transform of the relatively flat background, concentrating all power in a central feature of limited extent. We support these findings by significantly reducing the artifact through background removal before the phase-retrieval step. Large amounts of blurring in the diffraction patterns were also found to introduce diffuse artifacts, which could easily be mistaken as biologically relevant features. Other sources of noise such as sample heterogeneity and variation of pulse energy did not significantly degrade the quality of the reconstructions. Larger data volumes, made possible by the recent inauguration of high repetition-rate XFELs, allow for increased signal-to-background ratio and provide a way to minimize these artifacts. The anticipated development of three-dimensional Fourier-volume-assembly algorithms which are background aware is an alternative and complementary solution, which maximizes the use of data.

47 OTHER INSTRUMENTATION↗

Assessment of three dead detector correction methods for cone-beam computed tomography

Purpose: Dead detectors due to manufacturing defects or radiation damage in the electronic portal imaging devices (EPIDs) used for cone-beam computed tomography (CBCT) can lead to image degradation and ring artifacts. In this work three dead detector correction methods were assessed using megavoltage CBCT (MVCBCT) as a test system, with the goals of assessing the relative effectiveness of the three methods and establishing the conditions for which they fail. Methods: MVCBCT projections acquired with four linacs at 8 and 60 MU (monitor units) were degraded with varying percentages (2%-95%) of randomly distributed dead single detectors (RDSs), randomly distributed dead detector clusters (RDCs) of 2 mm diameter, and nonrandomly distributed dead detector disks (NRDDs) of varying diameter (4-16 mm). Correction algorithms were bidirectional linear interpolation (BLI), quad-directional linear interpolation (QLI), and a Laplacian solution (LS) method. Correction method failure was defined to occur if ring artifacts were present in the reconstructed phantom images from any linac or if the modulation transfer function (MTF) for any linac dropped below baseline with a p value, calculated with the two sample t test, of less than 0.01. Results: All correction methods failed at the same or lower RDC/RDS percentages and NRDD diameters for the 60 MU as for the 8 MU cases. The LS method tended to outperform or match the BLI and QLI methods. If ring artifacts anywhere in the images were considered unacceptable, the LS method failed for 60 MU at >33% RDS, >2% RDC, and >4 mm NRDD. If ring artifacts within 4 mm longitudinally of the phantom section interfaces were considered acceptable, the LS method failed for 60 MU at >90% RDS, >80% RDC, and >4 mm NRDD. LS failed due to MTF drop for 60 MU at >50% RDS, >25% RDC, and >4 mm NRDD. Conclusions: The LS method is superior to the BLI and QLI methods, and correction algorithm effectiveness decreases as imaging dose increases. All correction methods failed first due to ring artifacts and second due to MTF drop. If ring artifacts in axial slices within a 4 mm longitudinal distance from phantom section interfaces are acceptable, statistically significant loss in spatial resolution does not occur until over 25% of the EPID is covered in randomly distributed dead detectors, or NRDDs of 4 mm diameter are present.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MRI of prostate brachytherapy seeds at high field: A study in phantom

Postimplant evaluation of prostate brachytherapy using magnetic resonance imaging (MRI) at 1.5 T has met with some difficulties due to the uncertainty associated with seed localization despite the excellent anatomical delineation this imaging modality can achieve. Seeds in vascularized regions or outside the prostate, where signal heterogeneity or drop off can obscure their position, can be difficult to identify. The increase in SNR available at 3.0 T offers the potential to improve these issues with visualization. However, before moving directly to in vivo studies, it is important to investigate the effects of artifact size on the ability to localize multiple seeds in close proximity. These artifacts are of extra concern at higher field because of the increased induced field distortions surrounding the seeds. A single prostate brachytherapy seed (IMC6711, OncoSeed) and arrays of seed pairs were suspended in a porcine gel medium and imaged on 1.5 and 3 T MRI scanners for comparison. Two basic acquisition techniques utilized in a wide array of clinical sequences [spin-echo based and gradient-echo (GE) based] were investigated for the types of artifacts they produce, and their dependence on field. Analysis of the resulting voids was performed to determine the relative size of seeds as seen on the images, as well as the ability to distinguish seeds at close proximity. The seed voids at 3 T were only slightly larger than those obtained at 1.5 T (0.5 mm longer and wider) when using a spin-echo type sequence. For this work, the authors used a proton density fast spin-echo (FSE) sequence. These results are promising for the use of 3 T imaging for postimplant evaluation since the SNR will increase by roughly a factor of 2 with only a limited corresponding increase in artifact size. The minimum separation of the seeds to be completely distinguished using void analysis increased from between 1.5 and 3 mm to between 3 and 4.5 mm when going from 1.5 to 3 T FSE imaging. The minimum separation of the seeds for GE at the demonstration TE of 11 ms was found to be between 3 and 4.5 mm for 1.5 T and between 4.5 and 6 mm for 3 T. These GE artifact dimensions will scale down with TE and, as this happens, approach the dimensions of the FSE artifacts given above.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images

Purpose: Applications of cone-beam CT (CBCT) to image-guided radiation therapy (IGRT) are hampered by shading artifacts in the reconstructed images. These artifacts are mainly due to scatter contamination in the projections but also can result from uncorrected beam hardening effects as well as nonlinearities in responses of the amorphous silicon flat panel detectors. While currently, CBCT is mainly used to provide patient geometry information for treatment setup, more demanding applications requiring high-quality CBCT images are under investigation. To tackle these challenges, many CBCT correction algorithms have been proposed; yet, a standard approach still remains unclear. In this work, we propose a shading correction method for CBCT that addresses artifacts from low-frequency projection errors. The method is consistent with the current workflow of radiation therapy. Methods: With much smaller inherent scatter signals and more accurate detectors, diagnostic multidetector CT (MDCT) provides high quality CT images that are routinely used for radiation treatment planning. Using the MDCT image as ''free'' prior information, we first estimate the primary projections in the CBCT scan via forward projection of the spatially registered MDCT data. Since most of the CBCT shading artifacts stem from low-frequency errors in the projections such as scatter, these errors can be accurately estimated by low-pass filtering the difference between the estimated and raw CBCT projections. The error estimates are then subtracted from the raw CBCT projections. Our method is distinct from other published correction methods that use the MDCT image as a prior because it is projection-based and uses limited patient anatomical information from the MDCT image. The merit of CBCT-based treatment monitoring is therefore retained. Results: The proposed method is evaluated using two phantom studies on tabletop systems. On the Catphan(c)600 phantom, our approach reduces the reconstruction error from 348 Hounsfield unit (HU) without correction to 4 HU around the object center after correction, and from 375 HU to 17 HU in the high-contrast regions. In the selected regions of interest (ROIs), the average image contrast is increased by a factor of 3.3. When noise suppression is implemented, the proposed correction substantially improves the contrast-to-noise ratio (CNR) and therefore the visibility of low-contrast objects, as seen in a more challenging pelvis phantom study. Besides a significant improvement in image uniformity, a low-contrast object of {approx}25 HU, which is otherwise buried in the shading artifacts, can be clearly identified after the proposed correction due to a CNR increase of 3.1. Compared to a kernel-based scatter correction method coupled with an analytical beam hardening correction, our approach also shows an overall improved performance with some residual artifacts. Conclusions: By providing effective shading correction, our approach has the potential to improve the accuracy of more advanced CBCT-based clinical applications for IGRT, such as tumor delineation and dose calculation.

60 APPLIED LIFE SCIENCES↗

Correction for patient table-induced scattered radiation in cone-beam computed tomography (CBCT)

Purpose: In image-guided radiotherapy, an artifact typically seen in axial slices of x-ray cone-beam computed tomography (CBCT) reconstructions is a dark region or ''black hole'' situated below the scan isocenter. The authors trace the cause of the artifact to scattered radiation produced by radiotherapy patient tabletops and show it is linked to the use of the offset-detector acquisition mode to enlarge the imaging field-of-view. The authors present a hybrid scatter kernel superposition (SKS) algorithm to correct for scatter from both the object-of-interest and the tabletop. Methods: Monte Carlo simulations and phantom experiments were first performed to identify the source of the black hole artifact. For correction, a SKS algorithm was developed that uses separate kernels to estimate scatter from the patient tabletop and the object-of-interest. Each projection is divided into two regions, one defined by the shadow cast by the tabletop on the imager and one defined by the unshadowed region. The region not shadowed by the tabletop is processed using the recently developed fast adaptive scatter kernel superposition (fASKS) method which employs asymmetric kernels that best model scatter transport through bodylike objects. The shadowed region is convolved with a combination of slab-derived symmetric SKS kernels and asymmetric fASKS kernels. The composition of the hybrid kernels is projection-angle-dependent. To test the algorithm, pelvis phantom and in vivo data were acquired using a CBCT test stand, a Varian Acuity simulator, and a Varian On-Board Imager, all of which have similar geometries and components. Artifact intensities and Hounsfield unit (HU) accuracies in the reconstructions were assessed before and after the correction. Results: The hybrid kernel algorithm provided effective correction and produced substantially better scatter estimates than the symmetric SKS or asymmetric fASKS methods alone. HU nonuniformities in the reconstructed pelvis phantom were reduced from 220 to 50 HU (i.e., 22%-5%). In the in vivo scans, the black hole artifact was reduced by up to 147 HU, a 73% improvement, and anatomical details in the prostate and rectum areas were made considerably more visible. Conclusions: Radiotherapy tabletops, which are generally flatter and larger than those used for diagnostic CT, can produce significant scatter-related artifacts. The proposed hybrid SKS algorithm accurately estimates scatter from both the object-of-interest and the patient tabletop, and resulting image uniformities and HU accuracies are greatly improved.

60 APPLIED LIFE SCIENCES↗

Clinical evaluations of an amplitude-based binning algorithm for 4DCT reconstruction in radiation therapy

Purpose: Phase-binning algorithms are commonly utilized in 4DCT image reconstruction for characterization of tumor or organ shape and respiration motion, but breathing irregularities occurring during 4DCT acquisition can cause considerable image distortions. Recently, amplitude-binning algorithms have been evaluated as a potential improvement to phase-binning algorithms for 4DCT image reconstruction. The purpose of this study was to evaluate the performance of the first commercially available on-line retrospective amplitude-binning algorithm for comparison to the traditional phase-binning algorithm. Methods: Both phantom and clinical data were used for evaluation. A phantom of known geometry was mounted on a 4D motion platform programmed with seven respiratory waves (two computer generated and five patient trajectories) and scanned with a Philips Brilliance Big bore 16-slice CT simulator. 4DCT images were reconstructed using commercial amplitude- and phase-binning algorithms. Image quality of the amplitude- and phase-binned image sets was compared by evaluation of shape and volume distortions in reconstructed images. Clinical evaluations were performed on 64 4DCT patient image sets in a blinded review process. The amplitude- and phase-binned 4DCT maximum intensity projection (MIP) images were further evaluated for 28 stereotactic body radiation therapy (SBRT) cases of total 64 cases. A preliminary investigation of the effects of respiratory amplitude and pattern irregularities on motion artifact severity was conducted. Results: The phantom experiments illustrated that, as expected, maximum inhalation occurred at the 0% amplitude and maximum exhalation occurred at the 50% amplitude of the amplitude-binned 4DCT image sets. The phantom shape distortions were more severe in the images reconstructed from the phase-binning algorithm. In the clinical study, compared to the phase-binning algorithm, the amplitude-binning algorithm yielded fewer or less severe motion artifacts in 37.5% of the cases (24/64), comparable artifacts in 54.7% of the cases (35/64), and slightly greater artifacts in 7.8% of the cases (5/64). Evaluation of SBRT cases demonstrated that the reconstructed tumor sizes and locations were comparable in 96% (1/28) of the MIP image pairs generated from both amplitude- and phase-binning algorithms. In this case the amplitude-binned image set rendered a smaller tumor size, which was likely due to very shallow respiratory amplitudes occurring over several breathing cycles. Conclusions: Overall, the amplitude-binning algorithm for 4DCT reconstruction reduced the severity of tumor distortion and image artifacts compared to the phase-binning algorithm. However, the full range of motion may not be characterized using amplitude-binning algorithms. Despite superior performance, amplitude binning can still be susceptible to motion artifacts caused by large variations in amplitude of respiratory waves.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model-based dose calculations for {sup 125}I lung brachytherapy

Purpose: Model-baseddose calculations (MBDCs) are performed using patient computed tomography (CT) data for patients treated with intraoperative {sup 125}I lung brachytherapy at the Mayo Clinic Rochester. Various metallic artifact correction and tissue assignment schemes are considered and their effects on dose distributions are studied. Dose distributions are compared to those calculated under TG-43 assumptions. Methods: Dose distributions for six patients are calculated using phantoms derived from patient CT data and the EGSnrc user-code BrachyDose. {sup 125}I (GE Healthcare/Oncura model 6711) seeds are fully modeled. Four metallic artifact correction schemes are applied to the CT data phantoms: (1) no correction, (2) a filtered back-projection on a modified virtual sinogram, (3) the reassignment of CT numbers above a threshold in the vicinity of the seeds, and (4) a combination of (2) and (3). Tissue assignment is based on voxel CT number and mass density is assigned using a CT number to mass density calibration. Three tissue assignment schemes with varying levels of detail (20, 11, and 5 tissues) are applied to metallic artifact corrected phantoms. Simulations are also performed under TG-43 assumptions, i.e., seeds in homogeneous water with no interseed attenuation. Results: Significant dose differences (up to 40% for D{sub 90}) are observed between uncorrected and metallic artifact corrected phantoms. For phantoms created with metallic artifact correction schemes (3) and (4), dose volume metrics are generally in good agreement (less than 2% differences for all patients) although there are significant local dose differences. The application of the three tissue assignment schemes results in differences of up to 8% for D{sub 90}; these differences vary between patients. Significant dose differences are seen between fully modeled and TG-43 calculations with TG-43 underestimating the dose (up to 36% in D{sub 90}) for larger volumes containing higher proportions of healthy lung tissue. Conclusions: Metallic artifact correction is necessary for accurate application of MBDCs for lung brachytherapy; simpler threshold replacement methods may be sufficient for early adopters concerned with clinical dose metrics. Rigorous determination of voxel tissue parameters and tissue assignment is required for accurate dose calculations as different tissue assignment schemes can result in significantly different dose distributions. Significant differences are seen between MBDCs and TG-43 dose distributions with TG-43 underestimating dose in volumes containing healthy lung tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

The impact of low-Z and high-Z metal implants in IMRT: A Monte Carlo study of dose inaccuracies in commercial dose algorithms

Purpose: The aim of the study was to evaluate the dosimetric impact of low-Z and high-Z metallic implants on IMRT plans. Methods: Computed tomography (CT) scans of three patients were analyzed to study effects due to the presence of Titanium (low-Z), Platinum and Gold (high-Z) inserts. To eliminate artifacts in CT images, a sinogram-based metal artifact reduction algorithm was applied. IMRT dose calculations were performed on both the uncorrected and corrected images using a commercial planning system (convolution/superposition algorithm) and an in-house Monte Carlo platform. Dose differences between uncorrected and corrected datasets were computed and analyzed using gamma index (Pγ{sub <1}) and setting 2 mm and 2% as distance to agreement and dose difference criteria, respectively. Beam specific depth dose profiles across the metal were also examined. Results: Dose discrepancies between corrected and uncorrected datasets were not significant for low-Z material. High-Z materials caused under-dosage of 20%–25% in the region surrounding the metal and over dosage of 10%–15% downstream of the hardware. Gamma index test yielded Pγ{sub <1}>99% for all low-Z cases; while for high-Z cases it returned 91% < Pγ{sub <1}< 99%. Analysis of the depth dose curve of a single beam for low-Z cases revealed that, although the dose attenuation is altered inside the metal, it does not differ downstream of the insert. However, for high-Z metal implants the dose is increased up to 10%–12% around the insert. In addition, Monte Carlo method was more sensitive to the presence of metal inserts than superposition/convolution algorithm. Conclusions: The reduction in terms of dose of metal artifacts in CT images is relevant for high-Z implants. In this case, dose distribution should be calculated using Monte Carlo algorithms, given their superior accuracy in dose modeling in and around the metal. In addition, the knowledge of the composition of metal inserts improves the accuracy of the Monte Carlo dose calculation significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic resonance visualization of conductive structures by sequence-triggered direct currents and spin-echo phase imaging

Purpose: Instrument visualization in interventional magnetic resonance imaging (MRI) is commonly performed via susceptibility artifacts. Unfortunately, this approach suffers from limited conspicuity in inhomogeneous tissue and disturbed spatial encoding. Also, susceptibility artifacts are controllable only by sequence parameters. This work presents the basics of a new visualization method overcoming such problems by applying sequence-triggered direct current (DC) pulses in spin-echo (SE) imaging. SE phase images allow for background free current path localization. Methods: Application of a sequence-triggered DC pulse in SE imaging, e.g., during a time period between radiofrequency excitation and refocusing, results in transient field inhomogeneities. Dependent on the additional z-magnetic field from the DC, a phase offset results despite the refocusing pulse. False spatial encoding is avoided by DC application during periods when read-out or slice-encoding gradients are inactive. A water phantom containing a brass conductor (water equivalent susceptibility) and a titanium needle (serving as susceptibility source) was used to demonstrate the feasibility. Artifact dependence on current strength and orientation was examined. Results: Without DC, the brass conductor was only visible due to its water displacement. The titanium needle showed typical susceptibility artifacts. Applying triggered DC pulses, the phase offset of spins near the conductor appeared. Because SE phase images are homogenous also in regions of persistent field inhomogeneities, the position of the conductor could be determined with high reliability. Artifact characteristic could be easily controlled by amperage leaving sequence parameters unchanged. For an angle of 30° between current and static field visualization was still possible. Conclusions: SE phase images display the position of a conductor carrying pulsed DC free from artifacts caused by persistent field inhomogeneities. Magnitude and phase images are acquired simultaneously under the same conditions without the use of extra measurement time. The presented technique offers many advantages for precise instrument localization in interventional MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-304-05: Use of Local Noise Power Spectrum and Wavelets in Comprehensive EPID Quality Assurance

Purpose: As EPIDs are increasingly used for IMRT QA and real-time treatment verification, comprehensive quality assurance (QA) of EPIDs becomes critical. Current QA with phantoms such as the Las Vegas and PIPSpro™ can fail in the early detection of EPID artifacts. Beyond image quality assessment, we propose a quantitative methodology using local noise power spectrum (NPS) to characterize image noise and wavelet transform to identify bad pixels and inter-subpanel flat-fielding artifacts. Methods: A total of 93 image sets including bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Quantitative metrics such as modulation transform function (MTF), NPS and detective quantum efficiency (DQE) were computed for each image set. Local 2D NPS was calculated for each subpanel. A 1D NPS was obtained by radial averaging the 2D NPS and fitted to a power-law function. R-square and slope of the linear regression analysis were used for panel performance assessment. Haar wavelet transformation was employed to identify pixel defects and non-uniform gain correction across subpanels. Results: Overall image quality was assessed with DQE based on empirically derived area under curve (AUC) thresholds. Using linear regression analysis of 1D NPS, panels with acceptable flat fielding were indicated by r-square between 0.8 and 1, and slopes of −0.4 to −0.7. However, for panels requiring flat fielding recalibration, r-square values less than 0.8 and slopes from +0.2 to −0.4 were observed. The wavelet transform successfully identified pixel defects and inter-subpanel flat fielding artifacts. Standard QA with the Las Vegas and PIPSpro phantoms failed to detect these artifacts. Conclusion: The proposed QA methodology is promising for the early detection of imaging and dosimetric artifacts of EPIDs. Local NPS can accurately characterize the noise level within each subpanel, while the wavelet transforms can detect bad pixels and inter-subpanel flat fielding artifacts.

60 APPLIED LIFE SCIENCES↗

SU-E-I-26: The CT Compatibility of a Novel Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer

Purpose: To examine CT metal image artifact from a novel direction-modulated brachytherapy (DMBT) tandem applicator (95% tungsten) for cervical cancer using a commercially available orthopedic metal artifact reduction (O-MAR) algorithm. Comparison to a conventional stainless steel applicator is also performed. Methods: Each applicator was placed in a water-filled phantom resembling the female pelvis and scanned in a Philips Brilliance 16-slice CT scanner using two pelvis protocols: a typical clinical protocol (120kVp, 16×0.75mm collimation, 0.692 pitch, 1.0s rotation, 350mm field of view (FOV), 600mAs, 1.5mm slices) and a protocol with a higher kVp and mAs setting useful for larger patients (140kVp, 16×0.75mm collimation, 0.688 pitch, 1.5s rotation, 350mm FOV, 870mAs, 1.5mm slices). Images of each tandem were acquired with and without the application of the O-MAR algorithm. Baseline scans of the phantom (no applicator) were also collected. CT numbers were quantified at distances from 5 to 30 mm away from the applicator’s edge (in increments of 5mm) using measurements at eight angles around the applicator, on three consecutive slices. Results: While the presence of both applicators degraded image quality, the DMBT applicator resulted in larger streaking artifacts and dark areas in the image compared to the stainless steel applicator. Application of the O-MAR algorithm improved all acquired images, both visually and quantitatively. The use of low and high kVp and mAs settings (120 kVp/600mAs and 140 kVp/870mAs) in conjunction with the O-MAR algorithm lead to similar CT numbers in the vicinity of the applicator and a similar reduction of the induced metal artifact. Conclusion: This work indicated that metal artifacts induced by the DMBT and the stainless steel applicator are greatly reduced when using the O-MAR algorithm, leading to better quality phantom images. The use of a high dose protocol provided similar improvements in metal artifacts compared to the clinical protocol.

60 APPLIED LIFE SCIENCES↗

Limited-angle effect compensation for respiratory binned cardiac SPECT

Purpose: In cardiac single photon emission computed tomography (SPECT), respiratory-binned study is used to combat the motion blur associated with respiratory motion. However, owing to the variability in respiratory patterns during data acquisition, the acquired data counts can vary significantly both among respiratory bins and among projection angles within individual bins. If not properly accounted for, such variation could lead to artifacts similar to limited-angle effect in image reconstruction. In this work, the authors aim to investigate several reconstruction strategies for compensating the limited-angle effect in respiratory binned data for the purpose of reducing the image artifacts. Methods: The authors first consider a model based correction approach, in which the variation in acquisition time is directly incorporated into the imaging model, such that the data statistics are accurately described among both the projection angles and respiratory bins. Afterward, the authors consider an approximation approach, in which the acquired data are rescaled to accommodate the variation in acquisition time among different projection angles while the imaging model is kept unchanged. In addition, the authors also consider the use of a smoothing prior in reconstruction for suppressing the artifacts associated with limited-angle effect. In our evaluation study, the authors first used Monte Carlo simulated imaging with 4D NCAT phantom wherein the ground truth is known for quantitative comparison. The authors evaluated the accuracy of the reconstructed myocardium using a number of metrics, including regional and overall accuracy of the myocardium, uniformity and spatial resolution of the left ventricle (LV) wall, and detectability of perfusion defect using a channelized Hotelling observer. As a preliminary demonstration, the authors also tested the different approaches on five sets of clinical acquisitions. Results: The quantitative evaluation results show that the three compensation methods could all, but to different extents, reduce the reconstruction artifacts over no compensation. In particular, the model based approach reduced the mean-squared-error of the reconstructed myocardium by as much as 40%. Compared to the approach of data rescaling, the model based approach further improved both the overall and regional accuracy of the myocardium; it also further improved the lesion detectability and the uniformity of the LV wall. When ML reconstruction was used, the model based approach was notably more effective for improving the LV wall; when MAP reconstruction was used, the smoothing prior could reduce the noise level and artifacts with little or no increase in bias, but at the cost of a slight resolution loss of the LV wall. The improvements in image quality by the different compensation methods were also observed in the clinical acquisitions. Conclusions: Compensating for the uneven distribution of acquisition time among both projection angles and respiratory bins can effectively reduce the limited-angle artifacts in respiratory-binned cardiac SPECT reconstruction. Direct incorporation of the time variation into the imaging model together with a smoothing prior in reconstruction can lead to the most improvement in the accuracy of the reconstructed myocardium.

60 APPLIED LIFE SCIENCES↗

TU-AB-207A-03: Image Quality, Dose, and Clinical Applications

Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisition physics and hardware, reconstruction, artifacts, image quality, dose, and advanced clinical applications. The core objective is to explain the effects of these major system components on the image quality. This course will not focus on the rapid-changing advanced technologies given the two-hour time limit, but the fundamental principles discussed in this course may facilitate better understanding of those more complicated technologies. The course will begin with an overview of CT acquisition physics and geometry. X-ray tube and CT detector are important acquisition hardware critical to the overall image quality. Each of these two subsystems consists of several major components. An in-depth description of the function and failure modes of these components will be provided. Examples of artifacts related to these failure modes will be presented: off-focal radiation, tube arcing, heel effect, oil bubble, offset drift effect, cross-talk effect, and bad pixels. The fundamentals of CT image reconstruction will first be discussed on an intuitive level. Approaches that do not require rigorous derivation of mathematical formulations will be presented. This is followed by a detailed derivation of the Fourier slice theorem: the foundation of the FBP algorithm. FBP for parallel-beam, fan-beam, and cone-beam geometries will be discussed. To address the issue of radiation dose related to x-ray CT, recent advances in iterative reconstruction, their advantages, and clinical applications will also be described. Because of the nature of fundamental physics and mathematics, limitations in data acquisition, and non-ideal conditions of major system components, image artifact often arise in the reconstructed images. Because of the limited scope of this course, only major imaging artifacts, their appearance, and possible mitigation and corrections will be discussed. Assessment of the performance of a CT scanner is a complicated subject. Procedures to measure common image quality metrics such as high contrast spatial resolution, low contrast detectability, and slice profile will be described. The reason why these metrics used for FBP may not be sufficient for statistical iterative reconstruction will be explained. Optimizing radiation dose requires comprehension of CT dose metrics. This course will briefly describe various dose metrics, and interaction with acquisition parameters and patient habitus. CT is among the most frequently used imaging tools due to its superior image quality, easy to operate, and a broad range of applications. This course will present several interesting CT applications such as a mobile CT unit on an ambulance for stroke patients, low dose lung cancer screening, and single heartbeat cardiac CT. Learning Objectives: Understand the function and impact of major components of X-ray tube on the image quality. Understand the function and impact of major components of CT detector on the image quality. Be familiar with the basic procedure of CT image reconstruction. Understand the effect of image reconstruction on CT image quality and artifacts. Understand the root causes of common CT image artifacts. Be familiar with image quality metrics especially high and low contrast resolution, noise power spectrum, slice sensitivity profile, etc. Understand why basic image quality metrics used for FBP may not be sufficient to characterize the performance of advanced iterative reconstruction. Be familiar with various CT dose metrics and their interaction with acquisition parameters. New development in advanced CT clinical applications. JH: Employee of GE Healthcare. FD: No disclosure.; J. Hsieh, Jiang Hsieh is an employee of GE Healthcare.

60 APPLIED LIFE SCIENCES↗

TH-CD-207B-03: How to Quantify Temporal Resolution in X-Ray MDCT Imaging?

Purpose: In modern CT scanners, a quantitative metric to assess temporal response, namely, to quantify the temporal resolution (TR), remains elusive. Rough surrogate metrics, such as half of the gantry rotation time for single source CT, a quarter of the gantry rotation time for dual source CT, or measurements of motion artifact’s size, shape, or intensity have previously been used. In this work, a rigorous framework which quantifies TR and a practical measurement method are developed. Methods: A motion phantom was simulated which consisted of a single rod that is in motion except during a static period at the temporal center of the scan, termed the TR window. If the image of the motion scan has negligible motion artifacts compared to an image from a totally static scan, then the system has a TR no worse than the TR window used. By repeating this comparison with varying TR windows, the TR of the system can be accurately determined. Motion artifacts were also visually assessed and the TR was measured across varying rod motion speeds, directions, and locations. Noiseless fan beam acquisitions were simulated and images were reconstructed with a short-scan image reconstruction algorithm. Results: The size, shape, and intensity of motion artifacts varied when the rod speed, direction, or location changed. TR measured using the proposed method, however, was consistent across rod speeds, directions, and locations. Conclusion: Since motion artifacts vary depending upon the motion speed, direction, and location, they are not suitable for measuring TR. In this work, a CT system with a specified TR is defined as having the ability to produce a static image with negligible motion artifacts, no matter what motion occurs outside of a static window of width TR. This framework allows for practical measurement of temporal resolution in clinical CT imaging systems. Funding support: GE Healthcare; Conflict of Interest: Employee, GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Structural analysis of an ancient pottery by using FT-IR technique

Pottery artifacts are one of the most abundant findings among archaeological artifacts and their analysis can reveal information regarding daily life of that society. The composition of the artifact can be correlated to the age in which it was created. The authenticity of the artifact is also important. Forgers can “touch up” artifacts to make them appear original. FT-IR is a useful method to investigate the structure, bonding and chemical properties of materials and is used for the analysis of art and historical objects in support of efforts to conserve, restore, and validate authenticity of these rare objects. Generally, the minerals found in the pottery can be classified into primary minerals, firing minerals, and secondary minerals. The identification of firing minerals is essential requirement for the clarification of firing temperature which provides understanding of the civilization that created the potteries. Qualitative and also quantitative techniques such as XRD and bench top FTIR spectrometers are often not destructive but require a small amount of the sample to be separated from the material, in this case artifact. On the other hand, hand held FT-IR offers a method that is not invasive. The piece of the pottery used in the present study is shown in fig.1. The pot contains black, white, and brown decorations. The areas analyzed were mapped over the different colored decorations. This was done to determine the consistency of the composition of the pot. This can ultimately be used to determine if the pot was made at the same time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗