Search NASA⌕ Search

SEARCH · Search NASA

Results for “AUTOS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Auto-ignitive deflagration of CH4 blended DME/Air mixtures with composition stratification

Front propagation speeds from one dimensional simulations of DME/Air and DME/CH4/Air mixtures under engine relevant conditions are presented with reduced kinetics and transport. Different time scales of monochromatic inhomogeneities in DME concentration and varying DME-CH4 blending ratios are explored to understand its subsequent effect on the propagation speed as well as the ensuing transition from deflagration to spontaneous propagation. It is found that for a given timescale, the instantaneous peak propagation speed achieved by a front as well as its overall variation is significantly affected by the level of CH4 concentration in the mixture. Specifically, at relatively smaller time scales, the magnitude of variation in the instantaneous propagation speed is found to subside as the level of CH4 concentration in the mixture is increased. An opposite trend is observed at comparatively larger time scales, wherein, a rapid change in the instantaneous propagation speed is observed with an increase in the level of CH4 concentration. This study provides evidence as to how the propagation speed of a single fuel flame varies compared to a dual fuel flame under the influence of composition stratification.

Desai, Swapnil S.↗

Auto Procedure Parsing: A Natural Language Processing Approach

Nuclear Power Plant (NPP) operating procedure is “a set of rules that describes how actions on the plant should be made if a certain system goal should be accomplished. U.S. NPPs use paper-based procedures (PBPs). PBPs are difficult to use. Common errors with PBPs are: following the wrong procedure, omit a step etc. Computer based procedures (CPBs) offer great improvement in ensuring plant safety. Some studies rely on experienced operators to understand the procedure content and then reorganize the procedure with digitally executable capabilities. Other studies utilize the procedure format to design rules to extract information from the operating procedures. Existing studies in procedure parsing are manual, laborious and extract limited information. This study aims to automatically extract critical information from operating procedures for generating computer interpretable representation of procedures. Such representation can further be used for automatic dynamic human reliability analysis and CPB design etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnesium for Future Autos

In the quest for better fuel economy and improved environmental performance, magnesium may well become a metal of choice for constructing lighter, more efficient vehicles. Magnesium is the lightest structural metal, yet it has a high strength-to-weight ratio makes it comparable to steel in many applications. The world’s automakers already use magnesium for individual components. But new alloys and processing methods are needed before the metal can become economically and technologically feasible as a major automotive structural material. This article will explore the formation, challenges and initial results of an international collaboration—the Magnesium Front End Research and Development (MFERD) project—that is leveraging the expertise and resources of Canada, China and the United States to advance the creation of magnesium-intensive vehicles. The MFERD project aims to develop the enabling technologies and knowledge base that will lead to a vehicles that are 50-60 percent lighter, equally affordable, more recyclable and of equal or better quality when compared to today’s vehicles. Databases of information also will be captured in models to enable further alloy and manufacturing process optimization. Finally, a life-cycle analysis of the magnesium used will be conducted.

36 MATERIALS SCIENCE↗

Compressive auto-indexing in femtosecond nanocrystallography

Ultrafast nanocrystallography has the potential to revolutionize biology by enabling structural elucidation of proteins for which it is possible to grow crystals with 10 or fewer unit cells. The success of nanocrystallography depends on robust orientation-determination procedures that allow us to average diffraction data from multiple nanocrystals to produce a 3D diffraction data volume with a high signal-to-noise ratio. Such a 3D diffraction volume can then be phased using standard crystallographic techniques."Indexing" algorithms used in crystallography enable orientation determination of a diffraction data from a single crystal when a relatively large number of reflections are recorded. Here we show that it is possible to obtain the exact lattice geometry from a smaller number of measurements than standard approaches using a basis pursuit solver.

97 MATHEMATICS AND COMPUTING↗

Effects of Granular Control on Customers’ Perspective and Behavior with Automated Demand Response Systems

Automated demand response (Auto-DR) is expected to close the loop between buildings and the grid by providing machine-to-machine communications to curtail loads without the need for human intervention. Hence, it can offer more reliable and repeatable demand response results to the grid than the manual approach and make demand response participation a hassle-free experience for customers. However, many building operators misunderstand Auto-DR and are afraid of losing control over their building operation. To ease the transition from manual to Auto-DR, we designed and implemented granular control of Auto-DR systems so that building operators could modify or opt out of individual load-shed strategies whenever they wanted. This paper reports the research findings from this effort demonstrated through a field study in large commercial buildings located in New York City. We focused on (1) understanding how providing granular control affects building operators’ perspective on Auto-DR, and (2) evaluating the usefulness of granular control by examining their interaction with the Auto-DR user interface during test events. Through trend log analysis, interviews, and surveys, we found that: (1) the opt-out capability during Auto-DR events can remove the feeling of being forced into load curtailments and increase their willingness to adopt Auto-DR; (2) being able to modify individual load-shed strategies allows flexible Auto-DR participation that meets the building’s changing operational requirements; (3) a clear display of automation strategies helps building operators easily identify how Auto-DR is functioning and can build trust in Auto-DR systems.

Schetrit, Oren↗

Automated Volumetric Modulated Arc Therapy Treatment Planning for Stage III Lung Cancer: How Does It Compare With Intensity-Modulated Radio Therapy?

Purpose: To compare the quality of volumetric modulated arc therapy (VMAT) or intensity-modulated radiation therapy (IMRT) plans generated by an automated inverse planning system with that of dosimetrist-generated IMRT treatment plans for patients with stage III lung cancer. Methods and Materials: Two groups of 8 patients with stage III lung cancer were randomly selected. For group 1, the dosimetrists spent their best effort in designing IMRT plans to compete with the automated inverse planning system (mdaccAutoPlan); for group 2, the dosimetrists were not in competition and spent their regular effort. Five experienced radiation oncologists independently blind-reviewed and ranked the three plans for each patient: a rank of 1 was the best and 3 was the worst. Dosimetric measures were also performed to quantitatively evaluate the three types of plans. Results: Blind rankings from different oncologists were generally consistent. For group 1, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.6, 2.13, and 2.18, respectively. The auto-VMAT plans in group 1 had 10% higher planning tumor volume (PTV) conformality and 24% lower esophagus V70 (the volume receiving 70 Gy or more) than the manual IMRT plans; they also resulted in more than 20% higher complication-free tumor control probability (P+) than either type of IMRT plans. The auto- and manual IMRT plans in this group yielded generally comparable dosimetric measures. For group 2, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.55, 1.75, and 2.75, respectively. Compared to the manual IMRT plans in this group, the auto-VMAT plans and auto-IMRT plans showed, respectively, 17% and 14% higher PTV dose conformality, 8% and 17% lower mean lung dose, 17% and 26% lower mean heart dose, and 36% and 23% higher P+. Conclusions: mdaccAutoPlan is capable of generating high-quality VMAT and IMRT treatment plans for stage III lung cancer. Manual IMRT plans could achieve quality similar to auto-IMRT plans if best effort was spent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a commercial automatic treatment planning system for prostate cancers

Recent developments in Radiation Oncology treatment planning have led to the development of software packages that facilitate automated intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning. Such solutions include site-specific modules, plan library methods, and algorithm-based methods. In this study, the plan quality for prostate cancer generated by the Auto-Planning module of the Pinnacle{sup 3} radiation therapy treatment planning system (v9.10, Fitchburg, WI) is retrospectively evaluated. The Auto-Planning module of Pinnacle{sup 3} uses a progressive optimization algorithm. Twenty-three prostate cancer cases, which had previously been planned and treated without lymph node irradiation, were replanned using the Auto-Planning module. Dose distributions were statistically compared with those of manual planning by the paired t-test at 5% significance level. Auto-Planning was performed without any manual intervention. Planning target volume (PTV) dose and dose to rectum were comparable between Auto-Planning and manual planning. The former, however, significantly reduced the dose to the bladder and femurs. Regression analysis was performed to examine the correlation between volume overlap between bladder and PTV divided by the total bladder volume and resultant V70. The findings showed that manual planning typically exhibits a logistic way for dose constraint, whereas Auto-Planning shows a more linear tendency. By calculating the Akaike information criterion (AIC) to validate the statistical model, a reduction of interoperator variation in Auto-Planning was shown. We showed that, for prostate cancer, the Auto-Planning module provided plans that are better than or comparable with those of manual planning. By comparing our results with those previously reported for head and neck cancer treatment, we recommend the homogeneous plan quality generated by the Auto-Planning module, which exhibits less dependence on anatomic complexity.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-BRB-03: Cross-Institutional Validation of An Ultrafast Automatic Planning Platform for Breast Irradiation

Purpose: Recently an ultrafast automatic planning system for breast irradiation using tangential beams was developed by modeling relationships between patient anatomy and achieved dose distribution. This study evaluates the performance of this system when applied to a different patient population and dose calculation algorithm. Methods: The system and its anatomy-to-dose models was developed at institution A based on 20 cases, which were planned using manual fluence painting technique and calculated WITH heterogeneity correction. Institution B uses field-in-field planning technique and dose calculation WITHOUT heterogeneity correction. 11 breast cases treated at Institution B were randomly selected for retrospective study, including left and right sides, and different breast size (irradiated volumes defined by Jaw/MLC opening range from 875cc to 3516cc). Comparisons between plans generated automatically (Auto-Plans) and those used for treatment (Clinical-Plans) included: energy choice (single/mixed), volumes receiving 95%/100%/105%/110% Rx dose (V95%/V100%/V105%/V100%) relative to irradiated volume, D1cc, and LungV20Gy. Results: In 9 out of 11 cases single/mixed energy choice made by the software agreed with Clinical-Plans. For the remaining 2 cases software recommended using mixed energy and dosimetric improvements were observed. V100% were similar (p=0.223, Wilcoxon Signed-Rank test) between Auto-Plans and Clinical-Plans (57.6±8.9% vs. 54.8±9.5%). V95% is 2.3±3.0% higher for Auto-Plans (p=0.027), indicating reduced cold areas. Hot spot volume V105% were significantly reduced in Auto-Plan by 14.4±7.2% (p=0.004). Absolute V105% was reduced from 395.6±359.9cc for Clinical-Plans to 108.7±163cc for Auto-Plans. D1cc was 107.4±2.8% for Auto-Plans, and 109.2±2.4% for Clinical-Plans (p=0.056). LungV20Gy were 13.6±4.0% for Auto-Plan vs. 14.0±4.1% for Clinical-Plans (p=0.043). All optimizations were finished within 1.5min. Conclusion: The performance of this breast auto-planning system remained stable and satisfactory when applied to a different patient population and dose calculation algorithm. The auto-planning system was able to produce clinically similar Rx dose coverage with significantly improved homogeneity inside breast tissue, in less than 1.5min.

60 APPLIED LIFE SCIENCES↗

On-Board Sensor Diagnostics for Catalytic Converters Final Report CRADA No. TC-0882-94

The auto industry is one of the largest and most important sectors of the U;S. economy. At the time of the CRADA, the Big Three U.S. auto makers (Chrysler, Ford and GM) alone employed··608,000 workers·in this country and marketed some eight million new cars and trucks worth approximately $200 billion in sales revenues. When the impact of part suppliers, steel, aluminum, and electronics producers were included, the effect of a downturn in U.S. car manufacturing had a nationwide impact on jobs and the economy. For example, U.S. auto makers used 1/7 of all U.S. steel production and 1/6 of all U.S. aluminum production. Transplant Japanese factories cannot be expected to compensate for reductions by U.S. auto makers; in fact, transplants resulted in a net loss of U.S. jobs. In 1991, the Big Three U.S. auto makers sold 8.8 million new cars and trucks with over 620,000 employees while the Big Three Japanese firms (Toyota, Nissan, and Honda) sold 2.4 million new cars and trucks with only 37,000 U.S. employees. It was estimated that the Japanese­ owned, U.S.-located, auto assembly facilities enjoyed an $8-$9 an hour labor cost advantage over the U.S. Big Three by building new plants in rural areas and hiring young workers with smaller health care and pension needs. Most of the parts in the 2.4 million cars and trucks sold by Japanese auto makers come directly from Japan and the engineering activities were mostly performed in Japan before U.S. assembly began. The effect of these issues was reflected in the U.S. Japan trade imbalance; about two-thirds of Japan's trade surplus was attributable to autos and auto parts.

47 OTHER INSTRUMENTATION↗