Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerating cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Novel Magnetron Operation and Control Methods for Superconducting RF Accelerators

High power magnetrons designed and optimized for industrial heating, being injection-locked, have been suggested to power superconducting RF cavities for accelerators due to lower cost and higher efficiency. However, standard operation methods do not provide high efficiency with wideband control suppressing microphonics. We have developed and experimentally verified novel methods of operating and controlling the magnetron that provide stable RF generation with higher efficiency and lower noise than other RF sources. By our method the magnetrons operate with the anode voltage notably lower than the self-excitation threshold improving its performance. This is also a promising way to increase tube reliability and longevity. A magnetron operating with the anode voltage lower than the self-excitation threshold, in so-called stimulated coherent generation mode has special advantage for pulse operation with a gated injection-locking signal. This eliminates the need for expensive pulsed HV modulators and additionally increases the magnetron RF source efficiency due to absence of losses in HV modulators.

43 PARTICLE ACCELERATORS↗

Surgical Clips Assist in the Visualization of the Lumpectomy Cavity in Three-Dimensional Conformal Accelerated Partial-Breast Irradiation

Purpose: To determine to what extent the placement of surgical clips helps delineate the cavity in three-dimensional conformal accelerated partial-breast irradiation. Patients and Methods: Planning CT images of 100 lumpectomy cavities were reviewed in a cohort of 100 consecutive patients. The cavities were determined and categorized by two radiation oncologists according to cavity visualization score criteria and the breast density score. The two physicians first attempted to delineate the lumpectomy cavity without clips and then with clips. Results: In the case of high-density mammary tissue, the breast remodeling done during surgery does not enable the lumpectomy cavity to be sufficiently visualized. The use of surgical clips significantly improved the ability to visualize the lumpectomy cavity, with a 69% rate of concordance between physicians regardless of the breast tissue density. Conclusion: The placement of surgical clips at lumpectomy enables visualization of the lumpectomy cavity and allows upgrading of the cavity visualization score on CT scans obtained for accelerated partial-breast irradiation treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of RF Cavity Dark Current In Presence of Helical Magnetic Field

In order to produce muon beam of high enough quality to be used for a Muon Collider, its large phase space must be cooled several orders of magnitude. This task can be accomplished by ionization cooling. Ionization cooling consists of passing a high-emittance muon beam alternately through regions of low Z material, such as liquid hydrogen, and very high accelerating RF cavities within a multi-Tesla solenoidal focusing channel. But first high power tests of RF cavity with beryllium windows in solenoidal magnetic field showed a dramatic drop in accelerating gradient due to RF breakdowns. It has been concluded that external magnetic fields parallel to RF electric field significantly modifies the performance of RF cavities. However, magnetic field in Helical Cooling Channel has a strong dipole component in addition to solenoidal one. The dipole component essentially changes electron motion in a cavity compare to pure solenoidal case, making dark current less focused at field emission sites. The simulation of dark current dynamic in HCC performed with CST Studio Suit is presented in this paper.

43 PARTICLE ACCELERATORS↗

Solid core dipoles and switching power supplies: Lower cost light sources?

As a result of improvements in power semiconductors, moderate frequency switching supplies can now provide the hundreds of amps typically required by accelerators with zero-to-peak noise in the kHz region ~ 0.06% in current or voltage mode. Modeling was undertaken using a finite electromagnetic program to determine if eddy currents induced in the solid steel of CEBAF magnets and small supplemental additions would bring the error fields down to the 5ppm level needed for beam quality. The expected maximum field of the magnet under consideration is 0.85 T and the DC current required to produce that field is used in the calculations. An additional 0.1% current ripple is added to the DC current at discrete frequencies 360 Hz, 720 Hz or 7200 Hz. Over the region of the pole within 0.5% of the central integrated BdL the resulting AC field changes can be reduced to less than 1% of the 0.1% input ripple for all frequencies, and a sixth of that at 7200 Hz. Doubling the current, providing 1.5 T central field, yielded the same fractional reduction in ripple at the beam for the cases checked. A small dipole was measured at 60, 120, 360 and 720 Hz in two conditions and the results compared to the larger model for the latter two frequencies with surprisingly good agreement. Thus, for light sources with aluminum vacuum vessels and full energy linac injection, the combination of solid core dipoles and switching power supplies may result in significant cost savings.

acceleration cavities and magnets superconducting ↗

FEM models and Fourier decomposition of three thick septa

Here, the CEBAF recirculating linear accelerator uses 26 septa: 8 thin, 17 thick and one Lamberston. We report here on detailed FEM models of one thick current-sheet septum, the Lambertson, and a new thick-septum concept which contains features of both. The last has higher-order field components within a factor of two of the current-sheet septum and much lower current density in the conductor were it used as a 'drop-in' replacement in CEBAF. There are accelerator layouts in which the new concept is superior to the current sheet septum in both harmonic content and current density.

47 OTHER INSTRUMENTATION↗

Unconventional ideas for ionization cooling of muons

Small muon beams increase the luminosity of a muon collider. Reducing the momentum and position spreads of muons reduces emittance and leads to small, cool beams. Ionization cooling has been observed at the Muon Ionization Cooling Experiment. 6D emittance reduction by a factor of 100, 000 has been achieved in simulation. Another factor of 5 in cooling would meet the basic requirements of a high luminosity muon collider. In this paper we compare, for the first time, the amount of RF needed in a cooling channel to previous linacs. Here, we also outline three methods aimed to help achieve a final factor of 5 in 6D cooling.

43 PARTICLE ACCELERATORS↗

Technological developments and accelerator improvements for the FRIB beam power ramp-up

The Facility for Rare Isotope Beams (FRIB) began operation with 1 kW beam power for scientific users in May 2022 upon completion of 8 years of project construction. The ramp-up to the ultimate beam power of 400 kW, planned over a 6-year period, will enable the facility to reach its full potential for scientific discovery in isotope science and applications. In December 2023, a record-high beam power of 10.4 kW uranium was delivered to the target. Technological developments and accelerator improvements are being made over the entire facility and are key to completion of the power ramp-up. Major technological developments entail the phased deployment of high-power beam-intercepting systems, including the charge strippers, the charge selection systems, the production target, and the beam dump, along with support systems, including non-conventional utilities (NCU) and remote handling facilities. Major accelerator improvements include renovations to aging legacy systems associated with experimental beam lines and system automation for improved operational efficiency and better machine availability. Experience must be gained to safely handle the increased radiological impacts associated with high beam power; extensive machine studies and advanced beam tuning procedures are needed to minimize uncontrolled beam losses for the desired operating conditions. This paper discusses the technological developments and accelerator improvements with emphasis on major R&D efforts.

43 PARTICLE ACCELERATORS↗

A path to higher Q0 with large grain niobium cavities

The improvement of the quality factor Q{sub 0} of superconducting radio-frequency (SRF) cavities at medium accelerating gradients ({approx} 20 MV/m) is important in order to reduce the cryogenic losses in continuous wave accelerators for a variety of applications. In recent years, SRF cavities fabricated from ingot niobium have become a viable alternative to standard high-purity fine-grain Nb for the fabrication of high-performing SRF cavities with the possibility of significant cost reduction. Initial studies demonstrated the improvement of Q{sub 0} at medium field in cavities heat treated at 800-1000 C without subsequent chemical etching. To further explore this treatment procedure, a new induction furnace with an all-niobium hot-zone was commissioned. A single-cell 1.5 GHz cavity fabricated from ingot material from CBMM, Brazil, with RRR {approx} 200, was heat treated with the new furnace in the temperature range 600-1200 C for several hours. Residual resistance values 1-5 nano-ohm have been consistently achieved on this cavity as well as Q{sub 0} values above {approx} 2 x 10{sup 11} at 2 K and 100 mT peak surface magnetic field. Q{sub 0}-values of the order of 10{sup 11} have been measured at 1.5 K.

43 PARTICLE ACCELERATORS↗

Design Methodology and Consideratios for NOVA 53 MHZ RF Cavities

The NO?A Experiment will construct a detector optimized for electron neutrino detection in the existing Neutrino at Main Injector (NuMI) beamline. This beamline is capable of operating at 400 kW of primary beam power and the upgrade will allow up to 700 kW. The cavities will operate at 53 MHz and three of them will be installed in the Recycler beamline. Thermal stability of the cavities is crucial since this affects the tuning. Results of finite element thermal and structural analysis involving the copper RF cavity will be presented.

43 PARTICLE ACCELERATORS↗

Cavity control of a single-electron quantum cyclotron: Measuring the electron magnetic moment

Measurements with a one-electron quantum cyclotron determine the electron magnetic moment, given by g/2=1.001 159 652 180 73(28)[0.28ppt], and the fine structure constant, {alpha}{sup -1}=137.035 999 084(51)[0.37ppb]. Announcements of these measurements [Phys. Rev. Lett. 97, 030801 (2006); 100, 120801 (2008)] are supplemented here with a more complete description of the one-electron quantum cyclotron and the measurement methods, a discussion of the cavity control of the radiation field, a summary of the analysis of the measurements, and a fuller discussion of the uncertainties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma Photocathodes

Abstract Plasma wakefield accelerators offer accelerating and focusing electric fields three to four orders of magnitude larger than state‐of‐the‐art radiofrequency cavity‐based accelerators. Plasma photocathodes can release ultracold electron populations within such plasma waves and thus open a path toward tunable production of well‐defined, compact electron beams with normalized emittance and brightness many orders of magnitude better than state‐of‐the‐art. Such beams will have far‐reaching impact for applications such as light sources, but also open up new vistas on high energy and high field physics. This paper reviews the innovation of plasma photocathodes, and reports on the experimental progress, challenges, and future prospects of the approach. Details of the proof‐of‐concept demonstration of a plasma photocathode in 90° geometry at SLAC FACET within the E‐210: Trojan Horse program are described. Using this experience, alongside theoretical and simulation‐supported advances, an outlook is given on future realizations of plasma photocathodes such as the upcoming E‐310: Trojan Horse‐II program at FACET‐II with prospects toward excellent witness beam parameter quality, tunability, and stability. Future installations of plasma photocathodes also at compact, hybrid plasma wakefield accelerators, will then boost capacities and open up novel capabilities for experiments at the forefront of interaction of high brightness electron and photon beams.

Habib, Ahmad Fahim↗

PERFORMANCE STUDY OF LIQUID NITROGEN THERMO-SIPHON COOLING LOOP

A RF-superconducting linear accelerator (LINAC) booster for the existing 15 UD Pelletron accelerator is presently under construction at Inter-University Accelerator Centre in New Delhi, India. The LINAC will make use of superconducting niobium quarter-wave resonators (QWR) as the accelerating element, and will consist of three accelerating cryomodules. A gravity-assisted (thermo-siphon) flow scheme with liquid nitrogen has been proposed to cool the thermal radiation shields of the LINAC cryomodules. A small test rig of the thermo-siphon loop has been developed to simulate and investigate the chosen aspects of the proposed configuration. The experimental work has been focused on the thermal performances of the specially designed copper clamps and optimization of the system engineering parameters. The paper presents the results of the thermo-siphon measurements and the qualitative description of the investigated phenomena.

42 ENGINEERING↗

Calibration of the ERL cavity FPC and PU couplers

The performance parameters of a superconducting cavity, notably accelerating field and quality factor, are first obtained in a cryogenic vertical test Dewar, and again after the final assembly in its cryostat. The tests involve Network Analyzer (NA) measurements in which the cavity is excited through an input coupler and the properties are obtained from the reflected signal at the input and the transmitted signal from the output coupler. The interpretation of the scattering coefficients in terms of field strength requires the knowledge of the Fundamental Power Coupler (FPC) and Pick-Up (PU) coupler strength, as expressed by their 'external' and Q{sub FPC} Q{sub PU}. The coupler strength is independent of the field level or cavity losses and thus can be determined at low levels with the scattering coefficients S{sub 11} and S{sub 21}, assuming standard 50 {Omega} terminations in the network analyzer. Also needed is the intrinsic cavity parameter, R{sub a} /Q{sub 0} {triple_bond} {l_brace}R/Q{r_brace}, a quantity independent of field or losses which must be obtained from simulation programs, such as the Microwave Studio.

43 PARTICLE ACCELERATORS↗

LLRF design for the HINS-SRF test facility at Fermilab

The High Intensity Neutrino Source (HINS) R&D program requires super conducting single spoke resonators operating at 325 MHz (SSR1). After coupler installation, these cavities are tested at the HINS-SRF facility at Fermilab. The LLRF requirements for these tests include support for continuous wave and pulsed mode operations, with the ability to track the resonance frequency of the tested cavity. Real-time measurement of the cavity loaded Q and Q{sub 0} are implemented using gradient decay techniques, allowing for Q{sub 0} versus E{sub acc} plots. A real time cavity simulator was also developed to test the LLRF system and verify its functionality.

43 PARTICLE ACCELERATORS↗

Plasma treatment of bulk niobium surface for superconducting rf cavities: Optimization of the experimental conditions on flat samples

Accelerator performance, in particular the average accelerating field and the cavity quality factor, depends on the physical and chemical characteristics of the superconducting radio-frequency (SRF) cavity surface. Plasma based surface modification provides an excellent opportunity to eliminate nonsuperconductive pollutants in the penetration depth region and to remove the mechanically damaged surface layer, which improves the surface roughness. Here we show that the plasma treatment of bulk niobium (Nb) presents an alternative surface preparation method to the commonly used buffered chemical polishing and electropolishing methods. We have optimized the experimental conditions in the microwave glow discharge system and their influence on the Nb removal rate on flat samples. We have achieved an etching rate of 1.7 μm/min⁡ using only 3% chlorine in the reactive mixture. Combining a fast etching step with a moderate one, we have improved the surface roughness without exposing the sample surface to the environment. We intend to apply the optimized experimental conditions to the preparation of single cell cavities, pursuing the improvement of their rf performance.

43 PARTICLE ACCELERATORS↗