Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Training a Neural Network on Analog TaO x ReRAM Devices Irradiated With Heavy Ions: Effects on Classification Accuracy Demonstrated With CrossSim

The image classification accuracy of a TaO x ReRAM-based neuromorphic computing accelerator is evaluated after intentionally inducing a displacement damage up to a fluence of 10 14 2.5-MeV Si ions/cm 2 on the analog devices that are used to store weights. Results are consistent with a radiation-induced oxygen vacancy production mechanism. When the device is in the high-resistance state during heavy ion radiation, the device resistance, linearity, and accuracy after training are only affected by high fluence levels. Here, the findings in this paper are in accordance with the results of previous studies on TaO x -based digital resistive random access memory. When the device is in the low-resistance state during irradiation, no resistance change was detected, but devices with a 4-kΩ inline resistor did show a reduction in accuracy after training at 10 14 2.5-MeV Si ions/cm 2 . This indicates that changes in resistance can only be somewhat correlated with changes to devices’ analog properties. This paper demonstrates that TaO x devices are radiation tolerant not only for high radiation environment digital memory applications but also when operated in an analog mode suitable for neuromorphic computation and training on new data sets.

42 ENGINEERING↗

Singular Perturbation-Based Large-Signal Order Reduction of Microgrids for Stability and Accuracy Synthesis With Control

The increasing penetration of distributed energy resources (DERs) highlights the growing importance of microgrids (MGs) in enhancing power system reliability. Employing electromagnetic transient (EMT) analysis in MGs becomes crucial for controlling the rapid transients. However, this requires an accurate but high-order model of power electronics and their underlying control loops, complexifying the stability analysis from the viewpoint of a higher control level. To overcome these challenges, this paper proposes a large-signal order reduction (LSOR) method for MGs with considerations of external control inputs and the detailed dynamics of underlying control levels based on singular perturbation theory (SPT). Specially, we innovatively proposed and strictly proved a general stability and accuracy assessment theorem that allows us to analyze the dynamic stability of a full-order nonlinear system by only leveraging our derived reduced-order model (ROM) and boundary layer model (BLM). Furthermore, this theorem furnishes a set of conditions that determine the accuracy of the developed ROM. Lastly, by embedding such a theorem into the SPT, we propose a novel LSOR approach with guaranteed accuracy and stability analysis equivalence. Case studies are conducted on MG systems to show the effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pleural homocysteine for malignant pleural effusion: A prospective and double‐blind diagnostic test accuracy study

Abstract Objective To assess the accuracy of pleural fluid homocysteine for discriminating malignant pleural effusion (MPE) and benign pleural effusion (BPE). Methods A total of 194 patients from two cohorts (Hohhot and Changshu) with undiagnosed pleural effusion were prospectively enrolled. Their pleural homocysteine was measured, and its diagnostic accuracy and net benefit for MPE were analyzed by receiver operating characteristic (ROC) curve analysis and decision curve analysis, respectively. Results In the Hohhot cohort ( n = 136) and the Changshu cohort ( n = 58), MPE patients had significantly higher homocysteine levels than BPE patients. The areas under the ROC curves of homocysteine for the diagnosis of MPE were 0.61 ( p = 0.027) and 0.59 ( p = 0.247), respectively. The decision curves of homocysteine were close to the reference line in both the Hohhot cohort and the Changshu cohort. Conclusion The diagnostic accuracy of pleural fluid homocysteine for MPE was low.

Cao, Xi‐Shan↗

Accuracy of self‐reported weight, height and body mass index among older people in Japan

Aim Weight and height are usually self‐reported in population‐based epidemiological surveys. While the accuracy of self‐reports has been extensively studied in younger populations, less is known in older populations. We investigated the accuracy of self‐reported weight, height and body mass (BMI) in an older cohort in Japan, where overweight/obesity and underweight coexist. Methods We used data from older Japanese adults (≥65 years) participating in the Japan Gerontological Evaluation Study in 2016 to 2017 (7357 men and 9271 women). Self‐report data were linked to objective data obtained from clinical examinations. Results The mean ± standard deviation (SD) age was 74.5 ± 5.8 years, mean ± SD weight, height and BMI were 55.7 ± 10.1 kg, 156.0 ± 8.9 cm and 22.8 ± 3.1, respectively. Results showed high intraclass correlation coefficients for self‐reported and measured values (0.97 for weight; 0.96 for height). While weight/height were overestimated among men (weight by 0.096 kg; height by 0.27 cm) and women (weight by 0.18 kg; height by 0.27 cm), BMI tended to be slightly underestimated (−0.034 kg/m 2 for men; −0.037 kg/m 2 for women). However, the absolute differences between self‐reported and measured values were not negligible; people had a higher risk for both under‐ and overestimation of their BMI category with increasing age. Lower education predicted BMI overestimation, whereas lower income predicted BMI underestimation. Conclusions Overall accuracy of self‐reported body habitus was higher in this cohort of older Japanese compared with previous reports. Nevertheless, misclassification of BMI due to the misreporting of their weight/height was more common among the oldest‐old, as well as those with lower education and income. Geriatr Gerontol Int 2020; 20: 803–810 .

Yazawa, Aki↗

SU-E-T-396: Dosimetric Accuracy of Proton Therapy for Patients with Metal Implants in CT Scans Using Metal Deletion Technique (MDT) Artifacts Reduction

Purpose: To evaluate the dosimetric accuracy for proton therapy patients with metal implants in CT using metal deletion technique (MDT) artifacts reduction. Methods: Proton dose accuracies under CT metal artifacts were first evaluated using a water phantom with cylindrical inserts of different materials (titanium and steel). Ranges and dose profiles along different beam angles were calculated using treatment planning system (Eclipse version 8.9) on uncorrected CT, MDT CT, and manually-corrected CT, where true Hounsfield units (water) were assigned to the streak artifacts. In patient studies, the treatment plans were developed on manually-corrected CTs, then recalculated on MDT and uncorrected CTs. DVH indices were compared between the dose distributions on all the CTs. Results: For water phantom study with 1/2 inch titanium insert, the proton range differences estimated by MDT CT were with 1% for all beam angles, while the range error can be up to 2.6% for uncorrected CT. For the study with 1 inch stainless steel insert, the maximum range error calculated by MDT CT was 1.09% among all the beam angles compared with maximum range error with 4.7% for uncorrected CT. The dose profiles calculated on MDT CTs for both titanium and steel inserts showed very good agreements with the ones calculated on manually-corrected CTs, while large dose discrepancies calculated using uncorrected CTs were observed in the distal end region of the proton beam. The patient study showed similar dose distribution and DVHs for organs near the metal artifacts recalculated on MDT CT compared with the ones calculated on manually-corrected CT, while the differences between uncorrected and corrected CTs were much pronounced. Conclusion: In proton therapy, large dose error could occur due to metal artifact. The MDT CT can be used for proton dose calculation to achieve similar dose accuracy as the current clinical practice using manual correction.

60 APPLIED LIFE SCIENCES↗

Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accuracy-Based Annotation Quality Score (ABAQS) v1.0

Assessing genome annotation quality is crucial for downstream analyses, but current methods are inadequate for eukaryotes. We present Accuracy-Based Annotation Quality Score (ABAQS), a novel, minimal-data-driven method that comprehensively assesses annotation quality. ABAQS evaluates multiple factors, including genome completeness, gene model validity, and protein profile accuracy, outperforming other metrics like BUSCO and PSAURON. We applied ABAQS to over 2500 eukaryotic genomes and showed its robustness and effectiveness in evaluating genome annotation quality, making it a valuable tool for researchers working with genomic data. ABAQS reveals significant variation in annotation quality and highlights the importance of filtering in improving annotation quality and accuracy.

Haridas, Sajeet [Lawrence Berkeley National Labora↗

An initial investigation of accuracy required for the identification of small molecules in complex samples using quantum chemical calculated NMR chemical shifts

The majority of primary and secondary metabolites in nature have yet to be identified, representing a major challenge for metabolomics studies that currently require reference libraries from analyses of authentic compounds. Using currently available analytical methods, complete chemical characterization of metabolomes is infeasible for both technical and economic reasons. For example, unambiguous identification of metabolites is limited by the availability of authentic chemical standards, which, for the majority of molecules, do not exist. Computationally predicted or calculated data are a viable solution to expand the currently limited metabolite reference libraries, if such methods are shown to be sufficiently accurate. For example, determining nuclear magnetic resonance (NMR) spectroscopy spectra in silico has shown promise in the identification and delineation of metabolite structures. Many researchers have been taking advantage of density functional theory (DFT), a computationally inexpensive yet reputable method for the prediction of carbon and proton NMR spectra of metabolites. However, such methods are expected to have some error in predicted 13 >C and 1 H NMR spectra with respect to experimentally measured values. This leads us to the question–what accuracy is required in predicted 13 C and 1 H NMR chemical shifts for confident metabolite identification? Using the set of 11,716 small molecules found in the Human Metabolome Database (HMDB), we simulated both experimental and theoretical NMR chemical shift databases. We investigated the level of accuracy required for identification of metabolites in simulated pure and impure samples by matching predicted chemical shifts to experimental data. We found 90% or more of molecules in simulated pure samples can be successfully identified when errors of 1 H and 13 C chemical shifts in water are below 0.6 and 7.1 ppm, respectively, and below 0.5 and 4.6 ppm in chloroform solvation, respectively. In simulated complex mixtures, as the complexity of the mixture increased, greater accuracy of the calculated chemical shifts was required, as expected. However, if the number of molecules in the mixture is known, e.g., when NMR is combined with MS and sample complexity is low, the likelihood of confident molecular identification increased by 90%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of machine learning errors on human decision-making: manipulations of model accuracy, error types, and error importance

Abstract This study addressed the cognitive impacts of providing correct and incorrect machine learning (ML) outputs in support of an object detection task. The study consisted of five experiments that manipulated the accuracy and importance of mock ML outputs. In each of the experiments, participants were given the T and L task with T-shaped targets and L-shaped distractors. They were tasked with categorizing each image as target present or target absent. In Experiment 1, they performed this task without the aid of ML outputs. In Experiments 2–5, they were shown images with bounding boxes, representing the output of an ML model. The outputs could be correct (hits and correct rejections), or they could be erroneous (false alarms and misses). Experiment 2 manipulated the overall accuracy of these mock ML outputs. Experiment 3 manipulated the proportion of different types of errors. Experiments 4 and 5 manipulated the importance of specific types of stimuli or model errors, as well as the framing of the task in terms of human or model performance. These experiments showed that model misses were consistently harder for participants to detect than model false alarms. In general, as the model’s performance increased, human performance increased as well, but in many cases the participants were more likely to overlook model errors when the model had high accuracy overall. Warning participants to be on the lookout for specific types of model errors had very little impact on their performance. Overall, our results emphasize the importance of considering human cognition when determining what level of model performance and types of model errors are acceptable for a given task.

97 MATHEMATICS AND COMPUTING↗

Moving toward automated µFTIR spectra matching for microplastic identification: addressing false identifications and improving accuracy

Abstract Infrared spectroscopy is a widely used tool for studying microplastics and identifying microparticles. Researchers rely on spectral libraries to differentiate between synthetic and natural materials. Unfortunately, spectral library matching is not perfect, and best practices require researchers to use time consuming, manual peak matching to assess spectral matches. Moving toward automated matching requires increased confidence in the matching process. Using spectra matching software may increase the efficiency of particle identification, however some matching strategies may confuse natural materials such as cotton, silk, and plant matter with common classes of synthetics such as polyesters and polyamides. In this experiment, we prepared 22 pristine sample materials from natural and synthetic sources and measured micro-Fourier transform infrared (µFTIR) spectra in transmission mode for each sample using a Thermo Nicolet iN10 MX instrument. The collected spectra were then input into two spectral library matching systems (Omnic Picta and Open Specy), using a total of five identification routines. Next, we placed a subset of four pristine microplastic materials in a biologically active river system for two weeks to simulate environmental samples. These simulated environmental samples were processed using 10% hydrogen peroxide for 24 h to remove organic contamination and then identified using the strongest performing library. We found that libraries with fewer sample spectra produced lower correlation matches and that using derivative correction greatly reduced the number of inaccuracies in identifying materials as either natural or synthetic. We also found that environmental fouling reduced the correlation value of library matches when compared to pristine particles, however the effect was not consistent across the four materials tested. Overall, we found that the accuracy of automated library matching in the tested systems and processing routines varied from 64.1 to 98.0% for distinguishing between natural and synthetic materials, and that a high Hit Quality Index (HQI) did not always correlate with accuracy. These results are important for the microplastic field, demonstrating a need to rigorously test spectral libraries and processing routines with known materials to ensure identification accuracy.

Kozloski, Rachel↗

Data and Scripts associated with: “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy”

This data package is associated with the publication “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?” submitted to PLOS ONE and accepted for publication (Fulton, S.G. et al. 2023; doi not yet available).Variation in electrical conductivity (EC) of water is important to reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. This data package supports a study addressing the need for a robust performance assessment of open source (OS) EC sensors. We evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. This data package presents the results from the different testing laboratory configurations. It also includes an R script for statistical analysis of the data and an Arduino IDE file used to calibrate and collect data with the OS Atlas EC sensor. File types are .csv, .pdf, .R, and .ino.

54 ENVIRONMENTAL SCIENCES↗

Qualitative Evaluation of the Accuracy of Maps for Release of Hazardous Materials

The LinguisticBelief © software tool developed by Sandia National Laboratories was applied to provide a qualitative evaluation of the accuracy of various maps that provide information on releases of hazardous material, especially radionuclides. The methodology, "Uncertainty for Qualitative Assessments," includes uncertainty in the evaluation. The software tool uses the mathematics of fuzzy sets, approximate reasoning, and the belief/ plausibility measure of uncertainty. SNL worked cooperatively with the Remote Sensing Laboratory (RSL) and the National Atmospheric Release Advisory Center (NARAC) at Lawrence Livermore National Laboratory (LLNL) to develop models for three types of maps for use in this study. SNL and RSL developed the maps for "Accuracy Plot for Area" and "Aerial Monitoring System (AMS) Product Confidence". SNL and LLNL developed the "LLNL Model". For each of the three maps, experts from RSL and LLNL created a model in the LinguisticBelief software. This report documents the three models and provides evaluations of maps associated with the models, using example data. Future applications will involve applying the models to actual graphs to provide a qualitative evaluation of the accuracy of the maps, including uncertainty, for use by decision makers. A "Quality Thermometer" technique was developed to rank-order the quality of a set of maps of a given type. A technique for pooling expert option from different experts was provided using the PoolEvidence © software.

Darby, John L.↗

Qualification for PowerInsight accuracy of power measurements

Accuracy of component based power measuring devices forms a necessary basis for research in the area of power-efficient and power-aware computing. The accuracy of these devices must be quantified within a reasonable tolerance. This study focuses on PowerInsight, an out- of-band embedded measuring device which takes readings of power rails on compute nodes within a HPC system in realtime. We quantify how well the device performs in comparison to a digital oscilloscope as well as PowerMon2. We show that the accuracy is within a 6% deviation on measurements under reasonable load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Algorithms for Quantum-Level Accuracy in Atomistic Simulations: LDRD Final Report.

This report summarizes the result of LDRD project 12-0395, titled "Automated Algorithms for Quantum-level Accuracy in Atomistic Simulations." During the course of this LDRD, we have developed an interatomic potential for solids and liquids called Spectral Neighbor Analysis Poten- tial (SNAP). The SNAP potential has a very general form and uses machine-learning techniques to reproduce the energies, forces, and stress tensors of a large set of small configurations of atoms, which are obtained using high-accuracy quantum electronic structure (QM) calculations. The local environment of each atom is characterized by a set of bispectrum components of the local neighbor density projected on to a basis of hyperspherical harmonics in four dimensions. The SNAP coef- ficients are determined using weighted least-squares linear regression against the full QM training set. This allows the SNAP potential to be fit in a robust, automated manner to large QM data sets using many bispectrum components. The calculation of the bispectrum components and the SNAP potential are implemented in the LAMMPS parallel molecular dynamics code. Global optimization methods in the DAKOTA software package are used to seek out good choices of hyperparameters that define the overall structure of the SNAP potential. FitSnap.py, a Python-based software pack- age interfacing to both LAMMPS and DAKOTA is used to formulate the linear regression problem, solve it, and analyze the accuracy of the resultant SNAP potential. We describe a SNAP potential for tantalum that accurately reproduces a variety of solid and liquid properties. Most significantly, in contrast to existing tantalum potentials, SNAP correctly predicts the Peierls barrier for screw dislocation motion. We also present results from SNAP potentials generated for indium phosphide (InP) and silica (SiO 2 ). We describe efficient algorithms for calculating SNAP forces and energies in molecular dynamics simulations using massively parallel computers and advanced processor ar- chitectures. Finally, we briefly describe the MSM method for efficient calculation of electrostatic interactions on massively parallel computers.

Thompson, Aidan Patrick↗

Achievable Accuracy and Precision of Timing with Dynasen Piezo Electric Pins

Piezo electric pins from Dynasen are often used in the shock and detonation community for triggering or timing purposes. The purpose of this memorandum is to document factors that affect the accuracy and precision that can be reasonably expected from using the pins. Three different pin types were used and repetition of ablative laser pulses were used to measure the time variation both for the same pin and similar pins from a lot. It was established that the standard deviation for a common shock between all pins was 190 ps and that the maximum variance between any two similar pins was 960 ps. Thus it is clear that uncertainty in the pin location, cable lengths and electrical signal analysis are likely to affect accuracy and precision from piezo pin-based measurements far more than inherent pin-to-pin variation. However, these measurements also demonstrate that with suffcient experimental care, these off-the-shelf piezo pins are capable of nanosecond accuracy and precision.

42 ENGINEERING↗

Enhancing Fluid Flow Pressure and Saturation Prediction Accuracy and Reducing Uncertainty with Committee Machine – Illinois Basin Decatur Project (IBDP) as a Case Study

Presentation at the 17th International Conference on Greenhouse Gas Control Technologies GHGT-17 held in Calgary, Canada, October 20-24, 2024. Carbon capture and storage (CCS) is a way to play a critical role in the global transition to a low-emission economy. Current progress is hampered by a number of factors, among which the lack of risk-informed design tools and decision support frameworks is seen as a major roadblock. Significant interest exists in using artificial intelligence to accelerate CCS site feasibility studies, as well as to facilitate the permit application process. Existing works commonly train a single deep learning model. This work investigates the feasibility of using a conventional ensemble learning (committee machine) technique to further improve prediction accuracy. Ensemble-based algorithms generally improve over individual base learners in terms of robustness and accuracy. Deep ensembles, however, are time-consuming to create and train. A pragmatic question is whether small-sized ensembles may lead to prediction improvement. Here we evaluated the efficacy of an ensemble learning technique using the latent spectral model (LSM), an efficient deep neural operator algorithm, as base learners. Preliminary results, obtained using the Illinois Basin-Decatur Project (IBDP) carbon sequestration data/model, show that small-sized ensembles can improve prediction over the base learners, achieving prediction accuracy of ~1.6 psi root mean square error (RMSE) on pressure (relative the average reservoir pressure of 3150 psi), and less than 1.3% for saturation.

Sun, Alexander↗

Investigating Temperature Uniformity and Accuracy in PV Module Lamination: A Verification Study

This study investigates the temperature uniformity and accuracy of a photovoltaic (PV) module lamination process by addressing inconsistencies identified in 2017 data where irregular temperature changes were observed across setpoints. The 2017 data showed a notable drop in temperature upon bladder initiation, except for the 145 degrees Celsius profile. This inconsistency indicated potential inaccuracies in manual data recording methods. To address this concern, a verification experiment was conducted to evaluate temperature uniformity across the 2014 Bent River SPL2828 laminator platen and within test samples. Thermocouples, paired with Omega data acquisition software, were deployed to measure temperatures at multiple platen locations and within test samples. The experiment compared lamination temperatures of polyethylene-co-vinyl acetate (EVA) encapsulant when paired with solite glass or TPE backsheets. The methodology included verifying temperature uniformity directly on the platen and by using a large glass/EVA/glass sample using multiple thermocouples. Smaller samples were built with glass/EVA/glass and glass/EVA/backsheet configurations with one centered thermocouple to verify and compare sample temperatures. This verification aims to refine lamination temperature profiles, enhance data accuracy and provide insights into optimal process control for uniform module lamination. Ensuring consistent and uniform lamination may improve the accuracy and reliability of research outcomes.

14 SOLAR ENERGY↗

Analysis of Inlier and Outlier Compounds with Respect to Artificial Neural Network Cetane Number Prediction Accuracy

Artificial neural networks (ANNs) are exceptional at forming non-linear correlations between multivariate input and target variables; however, they are often seen as a “black box” approach, since how ANNs form these correlations is somewhat ambiguous. Furthermore, the process underlying how ANNs learn from inlier and outlier samples within the input dataset is not fully understood. Intuitively, it is expected that training ANNs with inlier samples will increase prediction accuracy and training with outlier samples will reduce prediction accuracy; though, in practice, this is not always true. The present work identifies and analyzes inliers and outliers of existing experimental cetane number (CN) data encompassing a variety of compounds and compound groups. It also investigates how ANNs trained to predict CN perform with and without outliers included in the training data, and whether a relationship exists between inliers/outliers and ANN prediction accuracy across the whole dataset and for individual samples. Additionally, individual outlier compounds are analyzed, highlighting how they structurally differ from inlier compounds.

09 BIOMASS FUELS↗