Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Edible oil structures at low and intermediate concentrations. II. Ultra-small angle X-ray scattering of in situ tristearin solids in triolein

Ultra-small angle X-ray scattering has been used for the first time to elucidate, in situ, the aggregation structure of a model edible oil system. The three-dimensional nano- to micro-structure of tristearin solid particles in triolein solvent was investigated using 5, 10, 15, and 20% solids. Three different sample preparation procedures were investigated: two slow cooling rates of 0.5°/min, case 1 (22 days of storage at room temperature) and case 2 (no storage), and one fast cooling of 30°/min, case 3 (no storage). The length scale investigated, by using the Bonse-Hart camera at beamline ID-15D at the Advanced Photon Source, Argonne National Laboratory, covered the range from 300 Å to 10 μm. The unified fit and the Guinier-Porod models in the Irena software were used to fit the data. The former was used to fit 3 structural levels. Level 1 structures showed that the primary scatterers were essentially 2-dimensional objects for the three cases. The scatterers possessed lateral dimensions between 1000 and 4300 Å. This is consistent with the sizes of crystalline nanoplatelets present which were observed using cryo-TEM. Level 2 structures were aggregates possessing radii of gyration, R{sub g2} between 1800 Å and 12000 Å and fractal dimensions of either D{sub 2}=1 for case 3 or 1.8≤D{sub 2}≤2.1 for case 1 and case 2. D{sub 2} = 1 is consistent with unaggregated 1-dimensional objects. 1.8 ≤ D{sub 2} ≤ 2.1 is consistent with these 1-dimensional objects (below) forming structures characteristic of diffusion or reaction limited cluster-cluster aggregation. Level 3 structures showed that the spatial distribution of the level 2 structures was uniform, on the average, for case 1, with fractal dimension D{sub 3}≈3 while for case 2 and case 3 the fractal dimension was D{sub 3}≈2.2, which suggested that the large-scale distribution had not come to equilibrium. The Guinier-Porod model showed that the structures giving rise to the aggregates with a fractal dimension given by D{sub 2} in the unified fit level 2 model were cylinders described by the parameter s≈1 in the Guinier-Porod model. The size of the base of these cylinders was in agreement with the cryo-TEM observations as well as with the results of the level 1 unified fit model. By estimating the size of the nanoplatelets and understanding the structures formed via their aggregation, it will be possible to engineer novel lipids systems that embody desired functional characteristics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recent developments in microtomography at GeoSoilEnviroCARS

A facility for x-ray computed microtomography (CMT) is operating as a national user facility for earth and environmental sciences research on the bending magnet beamline at the GeoSoilEnviroCARS sector at the Advanced Photon Source (APS). The APS bending magnet has a critical energy of 20 keV, and thus provides high flux at photon energies up to 100 keV, making it well suited to imaging a wide range of earth materials up to several cm in size. The beamline is equipped with a Si (111) double-crystal monochromator covering the energy range from 5 to 70 keV with beam sizes up to 50mm wide and 6mm high. The transmitted x-rays are imaged with a single crystal YAG or CdWO{sub 4} scintillator, a microscope objective and a 1300 x 1030 pixel 12-bit 5MHz CCD detector. The maximum spatial resolution is under 1.5 {micro}m in both the transmission radiographs and the reconstructed slices. Data collection times for full 3-D datasets range from 5-60 minutes. This facility has been used for a wide range of studies, including multiphase fluids in porous media, high-pressure studies, meteorites, and hyper-accumulating plants. We present recent technical improvements in the system, which include improved optics for samples larger than 5mm, significant reduction of ring artifacts, and correction of mechanical errors in the rotation stage.

43 PARTICLE ACCELERATORS↗

High-flux hard X-ray microbeam using a single-bounce capillary with doubly focused undulator beam

A pre-focused X-ray beam at 12 keV and 9 keV has been used to illuminate a single-bounce capillary in order to generate a high-flux X-ray microbeam. The BioCAT undulator X-ray beamline 18ID at the Advanced Photon Source was used to generate the pre-focused beam containing 1.2 x 10{sup 13} photons s{sup -1} using a sagittal-focusing double-crystal monochromator and a bimorph mirror. The capillary entrance was aligned with the focal point of the pre-focused beam in order to accept the full flux of the undulator beam. Two alignment configurations were tested: (i) where the center of the capillary was aligned with the pre-focused beam ('in-line') and (ii) where one side of the capillary was aligned with the beam ('off-line'). The latter arrangement delivered more flux (3.3 x 10{sup 12} photons s{sup -1}) and smaller spot sizes ({le}10 {micro}m FWHM in both directions) for a photon flux density of 4.2 x 10{sup 10} photons s{sup -1} {micro}m{sup -2}. The combination of the beamline main optics with a large-working-distance (approximately 24 mm) capillary used in this experiment makes it suitable for many microprobe fluorescence applications that require a micrometer-size X-ray beam and high flux density. These features are advantageous for biological samples, where typical metal concentrations are in the range of a few ng cm{sup -2}. Micro-XANES experiments are also feasible using this combined optical arrangement.

43 PARTICLE ACCELERATORS↗

Sub-nanosecond laser-induced structural changes in the phase change material Ge2Sb2Te5 measured by an optical pump/x-ray probe technique

Phase-change alloys are characterized by reversible switching between amorphous and crystalline phases either by laser irradiation or by an electric programming current; the resulting changes in material properties can be used for non-volatile data storage. Switching typically occurs on nanosecond or less time scales. Considering the conflicting requirements for high-speed switching, yet long term data storage integrity, a deeper understanding of the switching processes in these materials is essential for insightful application development. Although, high-speed optical pump/probe observations have been made of reflectivity changes during the Ge{sub 2}Sb{sub 2}Te{sub 5} switching process, due to the nanosecond order time scales involved little is known about the corresponding changes in structure. In addition as the amorphous phase does not diffract, its structural analysis is not amenable to analysis by high-speed diffraction techniques. We have used synchrotron-based time-resolved x-ray absorption fine structure spectroscopy (XAFS), a technique equally suitable for amorphous and crystalline phases to elaborate details in structural changes in the phase-change process. We report on two experiments using high-speed pulsed lasers that serve as optical pumps to induced material changes followed by synchrotron produced x-ray burst that serve as a time resolved structural probe. The first experiment carried out at the Advanced Photon source focuses on changes due to heating in the amorphous phase. Our experimental results indicate that the maximum temperature reached during the re-amorphization process are less than the melting point indicated in the bulk phase diagram of Ge{sub 2}Sb{sub 2}Te{sub 5} reaching a maximum temperature of 620 C and in addition, do not share the same bond length distribution of a true melt. These findings strongly suggest the possibility of non-thermal melting. In the second experiment, we have obtained near-edge x-ray absorption data for a Ge{sub 2}Sb{sub 2}Te{sub 5} film in the process of transforming from the crystalline to the amorphous phase. This was accomplished by use of a second re-crystallizing laser in addition to the amorphous state induced fast pulsed laser. In the experiment presented here a 500 ps, 532 nm high-power pump laser was focused to a spot size of 20 {micro}m via the silica substrate onto a 50 {micro}m thick Ge{sub 2}Sb{sub 2}Te{sub 5} layer with a power density of approximately 60 mJ/cm{sup 2}; the layer was capped to prevent oxidation by air. Concentric to the laser beam, a 1 x 2.5 {micro}m x-ray pulse generated from a single electron bunch in the storage ring at Spring-8 was directed to the front side side of the sample. The relative delay of the laser with respect to the x-ray pulse was varied in steps of 500 ps in the current experiment. The presence of a 30 nm thick (ZnS){sub 0.85}(SiO{sub 2}){sub 0.15} layer above the Ge{sub 2}Sb{sub 2}Te{sub 5} layer caused the Ge{sub 2}Sb{sub 2}Te{sub 5} located below the layer spot to transform from a crystalline starting phase to an amorphous high-temperature phase and then back to a crystalline phase due to the trapped heat.

43 PARTICLE ACCELERATORS↗

APS Science 2007.

This report provides research highlights from the Advanced Photon Source (APS). Although these highlights represent less than 10% of the published work from the APS in 2007, they give a flavor of the diversity and impact of user research at the facility. In the strategic planning the aim is to foster the growth of existing user communities and foresee new areas of research. This coming year finds the APS engaged in putting together, along with the users, a blueprint for the next five years, and making the case for a set of prioritized investments in beamlines, the accelerator, and infrastructure, each of which will be transformational in terms of scientific impact. As this is written plans are being formulated for an important user workshop on October 20-21, 2008, to prioritize strategic plans. The fruit from past investments can be seen in this report. Examples include the creation of a dedicated beamline for x-ray photon correlation spectroscopy at Sector 8, the evolution of dedicated high-energy x-ray scattering beamlines at sectors 1 and 11, a dedicated imaging beamline at Sector 32, and new beamlines for inelastic scattering and powder diffraction. A single-pulse facility has been built in collaboration with Sector 14 (BioCARS) and Phil Anfinrud at the National Institutes of Health, which will offer exceptionally high flux for single-pulse diffraction. The nanoprobe at Sector 26, built and operated jointly by the Argonne Center for Nanoscale Materials and the X-ray Operations and Research (XOR) section of the APS X-ray Science Division, has come on line to define the state of the art in nanoscience.

43 PARTICLE ACCELERATORS↗

Synchrotron applications of an amorphous silicon flat-panel detector.

A GE Revolution 41RT flat-panel detector (GE 41RT) from GE Healthcare (GE) has been in operation at the Advanced Photon Source for over two years. The detector has an active area of 41 cm x 41 cm with 200 {micro}m x 200 {micro}m pixel size. The nominal working photon energy is around 80 keV. The physical set-up and utility software of the detector system are discussed in this article. The linearity of the detector response was measured at 80.7 keV. The memory effect of the detector element, called lag, was also measured at different exposure times and gain settings. The modulation transfer function was measured in terms of the line-spread function using a 25 {micro}m x 1 cm tungsten slit. The background (dark) signal, the signal that the detector will carry without exposure to X-rays, was measured at three different gain settings and with exposure times of 1 ms to 15 s. The radial geometric flatness of the sensor panel was measured using the diffraction pattern from a CeO{sub 2} powder standard. The large active area and fast data-capturing rate, i.e. 8 frames s{sup -1} in radiography mode, 30 frames s{sup -1} in fluoroscopy mode, make the GE 41RT one of a kind and very versatile in synchrotron diffraction. The loading behavior of a Cu/Nb multilayer material is used to demonstrate the use of the detector in a strain-stress experiment. Data from the measurement of various samples, amorphous SiO{sub 2} in particular, are presented to show the detector effectiveness in pair distribution function measurements.

43 PARTICLE ACCELERATORS↗

The large-volume high-pressure facility at GSECARS: A 'Swiss-army-knife' approach to synchrotron-based experimental studies

A number of new techniques have been developed at the large-volume press (LVP) high-pressure facility at the GeoSoilEnviroCARS (GSECARS) sector of the advanced photon source (APS). This article describes the 10 MN (1000 T) and 2.5 MN (250 T) hydraulic presses in the insertion device (ID) and bending magnet (BM) beamlines, respectively, with several apparatus and various diffraction and imaging techniques developed since the inception of the facility. Several Kawai-type high-pressure modules, whose second-stage anvils range from 10 mm to 25.4 mm in edge lengths, are used in the hydraulic presses, with pressure (P) and temperature (T) capabilities up to 30 GPa and 3000 K. A DIA-type apparatus can be compressed in both presses for studies requiring large sample volumes. A deformation DIA (D-DIA) has been developed to allow controlled deformation studies on both crystalline and glass materials, using monochromatic diffraction and imaging, up to 20 GPa and 1800 K. A high-pressure tomography apparatus is available for conducting tomography studies at high P and T, with a typical spatial resolution of a few micrometers. Toroidal anvil modules provide large 2{theta} angles for studies of non-crystalline materials, and a new large D-DIA module is under construction for double-stage megabar pressure generation as well as deformation on large samples with the capability of acoustic emission detection. The flexible design of the monochromator at the BM beamline makes it feasible to switch between monochromatic and white-beam mode during an experiment, ideal for monochromatic imaging studies (e.g., high-P tomography) with energy-dispersive diffraction for pressure measurements. A new angle-dispersive diffraction technique has been developed for high P-T crystallography studies, where a solid-state detector is step-scanned, thereby collecting a large number of angle-dispersive spectra over a wide range of photon energies recorded in the multi-channel analyzer. An ultrasonic interferometer is available and has been used in several high-pressure modules for acoustic velocity measurements. These unique features allow world-wide users to select the best experimental techniques for tackling a wide range of problems relevant to earth and planetary science, materials science, physics, and chemistry. Scientific highlights are provided and future improvements and prospects are discussed.

43 PARTICLE ACCELERATORS↗

Multi-Element Germanium Detectors with Integrated Readouts

In this study, we have developed a series of monolithic multi-element germanium detectors coupled with custom developed CMOS application specific integrated circuit (ASIC) for readout. Several strip detectors with element counts ranging from 64 to 384 were developed and are currently used at the National Synchrotron Light Source II in Brookhaven National Laboratory and the Advanced Photon Source in Argonne National Laboratory. Lastly, the detectors are photon counting and are used at high-energy diffraction and energy dispersive diffraction beamlines.

47 OTHER INSTRUMENTATION↗

Specimen-displacement correction for powder X-ray diffraction in Debye–Scherrer geometry with a flat area detector

The effect of small changes in the specimen-to-detector distance on the unit-cell parameters is examined for synchrotron powder diffraction in Debye–Scherrer (transmission) geometry with a flat area detector. An analytical correction equation is proposed to fix the shift in 2θ values due to specimen capillary displacement. This equation does not require the use of an internal reference material, is applied during the Rietveld refinement step, and is analogous to the specimen-displacement correction equations for Bragg–Brentano and curved-detector Debye–Scherrer geometry experiments, but has a different functional form. The 2θ correction equation is compared with another specimen-displacement correction based on the use of an internal reference material in which new integration and calibration parameters of area-detector images are determined. Example data sets showing the effect of a 3.3 mm specimen displacement on the unit-cell parameters for 25°C CeO 2 , including both types of displacement correction, are described. These experiments were performed at powder X-ray diffraction beamlines at the National Synchrotron Light Source II at Brookhaven National Laboratory and the Advanced Photon Source at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

In situ neutron and synchrotron diffraction of La0.9Sr0.1Co1-yFeyO3 (y=0, 0.25, 0.75, 1)

Powder La0.9Sr0.1Co1-yFeyO3 (y=0, 0.25, 0.75, 1) samples were probed via in situ neutron (POWGEN, Spallation Neutron Source, Oak Ridge National Laboratory) and synchrotron (11-BM, Advanced Photon Source, Argonne National Lab) diffraction cycling between methane and air at temperatures ranging from room temperature to 850 C. Mail in neutron data (POWGEN) was collected on the samples at room temperature and 10 K. Additionally, gas production under similar reaction conditions as the in situ diffraction as monitored by Gasboard 3100 (California State University, Fullerton) is also included.

catalysis↗

Isotropic negative thermal expansion in ZrW 2 O 8 and HfW 2 O 8 from 1100 to 1275°C

Abstract ZrW 2 O 8 (ZrO 2 •2WO 3 ) and HfW 2 O 8 (HfO 2 •2WO 3 ) have been the focus of thermal expansion studies due to their isotropic negative thermal expansion (NTE) measured previously at temperatures below 775°C. This work presents measurements of these materials at their thermodynamically stable temperature ranges of 1105 and 1257°C for ZrW 2 O 8 and 1105–1276°C for HfW 2 O 8 , where they were characterized with in situ, powder X‐ray diffraction. The linear coefficients of thermal expansion were measured to be −5.52 × 10 −6 and −4.87 × 10 −6 °C −1 for ZrW 2 O 8 and HfW 2 O 8 , respectively. The mechanism leading to this NTE is discussed. Powder samples were synthesized by a solution‐based process called the organic–inorganic steric entrapment method. In situ characterization in air was carried out at the National Synchrotron Light Source II using a hexapole lamp, optical furnace and the Advanced Photon Source using a quadrupole lamp, optical furnace to achieve elevated temperatures.

Materials Science↗

Preliminary neutron and X-ray crystallographic studies of equine cyanomethemoglobin

Room-temperature and 100 K X-ray and room-temperature neutron diffraction data have been measured from equine cyanomethemoglobin to 1.7 {angstrom} resolution using a home source, to 1.6 {angstrom} resolution on NE-CAT at the Advanced Photon Source and to 2.0 {angstrom} resolution on the PCS at Los Alamos Neutron Science Center, respectively. The cyanomethemoglobin is in the R state and preliminary room-temperature electron and neutron scattering density maps clearly show the protonation states of potential Bohr groups. Interestingly, a water molecule that is in the vicinity of the heme group and coordinated to the distal histidine appears to be expelled from this site in the low-temperature structure.

59 BASIC BIOLOGICAL SCIENCES↗

Inverse compton light source: a compact design proposal

In the last decade, there has been an increasing demand for a compact Inverse Compton Light Source (ICLS) which is capable of producing high-quality X-rays by colliding an electron beam and a high-quality laser. It is only in recent years when both SRF and laser technology have advanced enough that compact sources can approach the quality found at large installations such as the Advanced Photon Source at Argonne National Laboratory. Previously, X-ray sources were either high flux and brilliance at a large facility or many orders of magnitude lesser when produced by a bremsstrahlung source. A recent compact source was constructed by Lyncean Technologies using a storage ring to produce the electron beam used to scatter the incident laser beam. By instead using a linear accelerator system for the electron beam, a significant increase in X-ray beam quality is possible, though even subsequent designs also featuring a storage ring offer improvement. Preceding the linear accelerator with an SRF reentrant gun allows for an extremely small transverse emittance, increasing the brilliance of the resulting X-ray source. In order to achieve sufficiently small emittances, optimization was done regarding both the geometry of the gun and the initial electron bunch distribution produced off the cathode. Using double-spoke SRF cavities to comprise the linear accelerator allows for an electron beam of reasonable size to be focused at the interaction point, while preserving the low emittance that was generated by the gun. An aggressive final focusing section following the electron beam's exit from the accelerator produces the small spot size at the interaction point which results in an X-ray beam of high flux and brilliance. Taking all of these advancements together, a world class compact X-ray source has been designed. It is anticipated that this source would far outperform the conventional bremsstrahlung and many other compact ICLSs, while coming closer to performing at the levels found at large facilities than ever before. The design process, including the development between subsequent iterations, is presented here in detail, with the simulation results for this groundbreaking X-ray source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-averaged Spray Analysis in the Near-field Using Broadband and Narrowband X-ray Measurements

The characterization of a spray in the near-field region is challenging because of its high optical density in this region. X-ray based techniques, with weak scatter and strong penetration properties, can provide better characterization than optical assessment techniques in this region. Here, the effects of various operating parameters on the optical depth (defined as the accumulated liquid thickness in the beam path times the X-ray attenuation coefficient) and spray profile of an atomizing spray in the near-field region are evaluated based on time-averaged X-ray analysis techniques. Controlling parameters in the spray structure include swirl ratio, liquid phase Reynolds number, and gas phase Reynolds number. Data from the broadband X-ray radiographs obtained using a tube source at Iowa State University and from focused beam measurements at the Advanced Photon Source at Argonne National Laboratory are compared. The X-ray tube source at Iowa State University was operated at two different energy levels, which reveals that the X-ray tube source energy influenced the magnitude of the optical depth but did not change the shape of the distribution. For the no swirl condition, gas flow rate and liquid flow rate had opposite effects on the spray profile, where the spray widens as the gas flow rate increases and narrows as the liquid flow rate increases. As the swirl ratio increases from 0 to 1, the spray widens and then narrows. Furthermore, the critical swirl ratio at which the spray reaches its widest spread differs at different flow conditions.

42 ENGINEERING↗

A NEW THERMIONIC RF ELECTRON GUN FOR SYNCHROTRON LIGHT SOURCES

A thermionic RF gun is a compact and efficient source of electrons used in many practical applications. RadiaBeam Systems and the Advanced Photon Source at Argonne National Laboratory collaborate in developing of a reliable and robust thermionic RF gun for synchrotron light sources which would offer substantial improvements over existing thermionic RF guns and allow stable operation with up to 1A of beam peak current at a 100 Hz pulse repetition rate and a 1.5 μs RF pulse length. In this paper, we discuss the electromagnetic and engineering design of the cavity and report the progress towards high power tests of the cathode assembly of the new gun.

RF↗

Local atomic structure of Pd and Ag in the SiC containment layer of TRISO fuel particles fissioned to 20% burn-up

The structure and speciation of fission products within the SiC barrier layer of tristructural-isotropic (TRISO) fuel particles irradiated to 19.6% fissions per initial metal atom (FIMA) burnup in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) was investigated. As-irradiated fuel particles, as well as those subjected to simulated accident scenarios, were examined. The TRISO particles were characterized using synchrotron X-ray absorption fine-structure spectroscopy (XAFS) at the Materials Research Collaborative Access Team (MRCAT) beamline at the Advanced Photon Source. The TRISO particles were produced at Oak Ridge National Laboratory under the Advanced Gas Reactor Fuel Development and Qualification Program and sent to the ATR for irradiation. XAFS measurements on the palladium and silver K-edges were collected using the MRCAT undulator beamline. Analysis of the Pd edge indicated the formation of palladium silicides of the form Pd x Si (2 ≤ x ≤ 3). In contrast, Ag was found to be metallic within the SiC shell safety tested to 1700 °C. To the best of our knowledge, this is the first result demonstrating metallic bonding of silver from fissioned samples. Knowledge of these reaction pathways will allow for better simulations of radionuclide transport in the various coating layers of TRISO fuels for next generation nuclear reactors. In conclusion, they may also suggest different ways to modify TRISO particles to improve their fuel performance and to mitigate potential fission product release under both normal operation and accident conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Synchrotron Based Microstructural Characterization Method Development for Pu Oxides

Identification of new plutonium oxide signatures is a high priority focus area of the technical nuclear forensics and nonproliferation communities. Comprehensive materials science studies of plutonium oxide are needed to advance the understanding of the microcrystalline properties and their relationship to macro-scale morphologies and signatures. Plutonium oxide particle growth is depenedent on the microcrystalline strucutures, grain size, and orientation. Microcrystalline structures have been found to vary for plutonium oxide based on the oxidation state of plutonium, concentration of reactants, and the physiochemical conditions of precipitation. Empirical observation confirms the relationship between processing conditions and particle morphology. High sensitivity, non destructive analysis of individual microcrystalline grains requires the use of bright sources of X-rays produced by synchrotron radiation, such as those at the Advanced Photon Source. The light source can reveal higher resolution crystallographic mapping, more sensitive chemical analysis, and higher fidelity morphological information than any current methods at SRNL.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗