Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM FOCUSING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A sample holder with integrated laser optics for an ELMITEC photoemission electron microscope

We present a new sample holder compatible with ELMITEC Photoemission Electron Microscopes (PEEMs) containing an optical lens and a mirror. With the integrated optical elements, a laser beam is focused from the back side of the sample at normal incidence, yielding a minimum spot size of about 1 μm. This opens up new possibilities for local laser excitations in PEEM experiments such as imaging all-optical magnetization switching at a small length scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the LBNF Beamline

The Long Baseline Neutrino Facility (LBNF) will utilize a beamline located at Fermilab to provide and aim a neutrino beam of sufficient intensity and appropriate energy range toward DUNE detectors, placed deep underground at the Sanford Underground Research Facility (SURF) in South Dakota. The primary proton beam (60-120 GeV) will be extracted from the MI-10 section of Fermilab’s Main Injector and will be transported via a series of sixty-nine conventional magnets to a solid target. Neutrinos are produced after the protons hit the target and produce mesons which are subsequently focused by magnetic horns into a 194 m long decay pipe where they decay into muons and neutrinos. The hadron absorber, located directly downstream of the decay pipe is designed to absorb the residual energy from protons and secondary particles which have not decayed. Muon detectors placed downstream of the hadron absorber will provide important information about the neutrino beam properties such as the beam direction and intensity as well as the associated muon spectrum. The parameters of the facility were determined taking into account the physics goals, spacial and radiological constraints and the experience gained by operating the NuMI facility at Fermilab. The LBNF beamline facility is designed for initial operation at a proton-beam power of 1.2 MW, with the capability to support an upgrade to about 2.4 MW. LBNF/DUNE obtained CD-1 approval in November 2015. We discuss here the design status and the associated challenges as well as the R&D and plans for improvements before baselining the facility.

43 PARTICLE ACCELERATORS↗

Whistler waves generated by nongyrotropic and gyrotropic electron beams during asymmetric guide field reconnection

Using a two-dimensional particle-in-cell simulation of asymmetric reconnection with a guide field whose strength is 0.3 times the reconnecting magnetic field, we study electron distribution functions and wave intensities in the diffusion region, focusing on the electron diffusion region (EDR). Wave activities with frequencies below the electron cyclotron frequency are observed, and these are whistler waves propagating almost anti-parallel to the magnetic field. The waves are concentrated near the magnetospheric separatrix away from the X line, but the wave activity also spreads through the EDR near the X line. The reconnection outflows are asymmetric in the outflow direction in the magnetospheric side, and the wave intensity is stronger in the side of the faster electron outflow. We study the whistler waves using the fast Fourier transform, analyses of electron velocity distribution functions, and the dispersion solver calculation. Along the magnetospheric separatrix in the stronger outflow side, highly anisotropic electron beams exist with super-Alfvénic drift speeds. The dispersion analysis shows that there are two modes: a temperature anisotropy mode and a beam mode. Outside the EDR, the whistler wave intensity is highest near the separatrix, but the wave intensity decreases if we move away from the separatrix toward the magnetic neutral line because of the increase in the electron population near zero parallel velocity. In the EDR, in the velocity plane perpendicular to the magnetic field, ring/crescent electron distribution functions are observed. Near the X-line, the wave power is enhanced where nongyrotropic electrons contribute to increase the perpendicular temperature anisotropy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Whistler Waves Generated by Nongyrotropic and Gyrotropic Electron Beams During Asymmetric Guide Field Reconnection

Using a two-dimensional particle-in-cell simulation of asymmetric reconnection with a guide field whose strength is 0.3 times the reconnecting magnetic field, we study electron distribution functions and wave intensities in the diffusion region, focusing on the electron diffusion region (EDR). Wave activities with frequencies below the electron cyclotron frequency are observed, and these are whistler waves propagating almost anti-parallel to the magnetic field. The waves are concentrated near the magnetospheric separatrix away from the X line, but the wave activity also spreads through the EDR near the X line. The reconnection outflows are asymmetric in the outflow direction in the magnetospheric side, and the wave intensity is stronger in the side of the faster electron outflow. We study the whistler waves using the fast Fourier transform, analyses of electron velocity distribution functions, and the dispersion solver calculation. Along the magnetospheric separatrix in the stronger outflow side, highly anisotropic electron beams exist with super-Alfvénic drift speeds. The dispersion analysis shows that there are two modes: a temperature anisotropy mode and a beam mode. Outside the EDR, the whistler wave intensity is highest near the separatrix, but the wave intensity decreases if we move away from the separatrix toward the magnetic neutral line because of the increase in the electron population near zero parallel velocity. In the EDR, in the velocity plane perpendicular to the magnetic field, ring/crescent electron distribution functions are observed. Near the X-line, the wave power is enhanced where nongyrotropic electrons contribute to increase the perpendicular temperature anisotropy.

magnetic reconnection↗

MO-AB-BRA-08: A Modular Multi-Source X-Ray Tube for Novel Computed Tomography Applications

Purpose: To develop and build a practical implementation of an x-ray line source for the rapidly increasing number of multi-source imaging applications in CT. Methods: An innovative x-ray tube was designed using CST Particle Studio, ANSYS, and SolidWorks. A slowly varying magnetic field is synchronized with microsecond gating of multiple thermionic electron sources. Electrostatic simulations were run to optimize the geometry of the optics and prevent electrode arcing. Magnetostatic simulations were used for beam deflection studies and solenoid design. Particle beam trajectories were explored with an emphasis on focusing, acceleration, deflection, and space charge effects. Thermal constraints were analyzed for both transient and steady-state regimes. Electromagnetic simulations informed the design of a prototype unit under construction. Results: Particle tracking simulations for a benchtop system demonstrate that three 80 keV electron beams are able to be finely controlled and laterally swept a combined distance of 15 cm over a stationary target with an oscillating magnetic field in the hundreds of gauss. The beams are pulsed according to scanning sequences developed for implementation in a mock stationary CT scanner capable of a 30 ms temporal resolution. Beam spot diameters are approximately 1 mm for 30 mA beams and the stationary target stays well within thermal limits. The relevant hardware and control circuits were developed for incorporation into a physical prototype. Conclusion: A new multi-source x-ray tube was designed in a modular form factor to push the barriers of high-speed CT and spur growth in emerging imaging applications. This technology can be used as the basis for a stationary high-speed CT scanner, a system for generating a virtual fan-beam for dose reduction, or for reducing scatter radiation in cone-beam CT utilizing a tetrahedron beam CT geometry. A 2.4 kW benchtop system is currently being built to show proof of concept for the tube. Support for this research was provided by the University of Wisconsin Madison, Office of the Vice Chancellor for Research and Graduate Education with funding from the Wisconsin Alumni Research Foundation.

60 APPLIED LIFE SCIENCES↗

Quasi-optical design for systems to diagnose the electron temperature and density fluctuations on EAST

A system to simultaneously diagnose the electron temperature and density fluctuations is proposed for Experimental Advanced Superconducting Tokamak device. This system includes a common quasi-optical antenna, a correlation electron cyclotron emission (CECE) system that is used to measure the electron temperature fluctuations and a Doppler backscattering (DBS) system that is used to measure the electron density fluctuations. The frequency range of the proposed CECE system is 108-120 GHz, and this corresponds to a radial coverage of normalized radius ((R − R{sub 0})/a, R{sub 0} = 1850 mm, a = 450 mm) from 0.2 to 0.67 for the plasma operation with a toroidal magnetic field of 2.26 T. This paper focuses on the design of the quasi-optical antenna and aims at optimizing the poloidal resolution for different frequency bands. An optimum result gives the beam radius for the CECE system of 13-15 mm and this corresponds to a wave number range of k{sub θ} < 2.4 cm{sup −1}. The beam radius is 20-30 mm for V band (50-75 GHz) and 15-20 mm for W band (75-110 GHz).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Field Combined-Function Magnets for a 1.5 x 1.5 TeV Muon Collider Storage Ring

A new storage ring lattice based on combined function high-field magnets and conceptual designs of superconducting magnets with dipole and quadrupole coils for a muon collider with a c.o.m. energy of 3 TeV and an average luminosity of 4x10^{34 } cm^{-2} s^{-1} are presented. Magnets are designed to provide the required focusing field gradient and bending field in the aperture with the appropriate operation margin. Magnets have large apertures to provide an adequate space for internal absorbers, vacuum insulation, beam pipe, and helium channel. Coil cross-sections were optimized to achieve the best possible field quality in the magnet aperture occupied with beams. Magnet parameters are reported and compared with the requirements. Energy depositi on calculations with the MARS code have allowed to optimize parameters of inner absorbers and collimators in interconnect regions, thus reducing peak power density and dynamic loads to the tolerable levels.

43 PARTICLE ACCELERATORS↗

Radiation Safety Consideration for the Parasitic Final Focus Test Beam at SLAC

A low intensity electron beam parasitic to the operation of the Stanford Linear Collider (SLC) has been transported through the Final Focus Test Beam (FFTB) facility making secondary test beams available for users. Photons generated in collimation of the SLC electron and positron beams in the linac pass through a splitter magnet that deflects the primary beams away from the linac axis into the SLC beam lines. These photons are converted to electrons and positrons in a secondary production target located down beam on the hnac axis. The secondary electrons are then transported through the FFTB beam line onto experimental detectors. The average power of the parasitic beam is very low, thus, it presents no hazards. However, various accident scenarios involving failure of the splitter magnet and the active protection devices could send much more powerful SLC beams (up to 90 kilo-watts) into this zero-degree secondary beam line. For the accident case, the average power in the transmitted beam was calculated using the Monte Carlo programs EGS4 and TURTLE. Results from analysis of the radiation protection systems that assure safety during the parasitic operation are presented.

Rokni, S. H.↗

Local chromatic correction optics for Future Circular Collider e + e −

Local chromatic correction optics are proposed for the Future Circular e + − e − Collider. These new optics assume an identical layout of the magnets at all operation energies and include a new design for the arcs, for the straight sections, and for the final focus. The arcs design is a step forward from the classic FODO lattice that achieves near cancellation up to the fourth order of chromatic and geometric aberrations. Straight sections and the final focus benefit from the application of transparency conditions and are thus minimally impacting the global beam dynamics. The final focus design includes both vertical and horizontal chromaticity correction sections, crab sextupoles, and additional specific sextupoles and decapoles for the optimization of the dynamics off-energy. Decapoles are very effective in mitigating the reduction of dynamic aperture due to synchrotron radiation. Nonlinear magnet settings are further optimized with multiobjective algorithms. The overall properties of the new optics proposed are analyzed in the presence of errors and compared to other optics designs.

43 PARTICLE ACCELERATORS↗

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N↗

Current collection model on tether satellite system

Results are reported from numerical simulations of current collection by a tethered satellite moving in the earth magnetic field. The focus is on the instruments of the Research on Orbital Plasma Electrodynamics (ROPE) experiment planned for the TSS-1 mission (scheduled launch 1991). The derivation of the governing equations is outlined, and the results of simulations with and without the geomagnetic field are presented in graphs. It is predicted that beam-beam interaction will occur when no magnetic effect is present, especially when the instrument bias is lower than the local potential; with the magnetic effect, there should be complex multiple-stream interactions, magnetic-field shielding covering 30 percent or more of the satellite surface when the B field is greater than 0.35 G, and nearly complete collection of the electrons by the instrument arm.

Hwang, K. S.↗

The energy transfer in the TEMP-4M pulsed ion beam accelerator

The results of a study of the energy transfer in the TEMP-4M pulsed ion beam accelerator are presented. The energy transfer efficiency in the Blumlein and a self-magnetically insulated ion diode was analyzed. Optimization of the design of the accelerator allows for 85% of energy transferred from Blumlein to the diode (including after-pulses), which indicates that the energy loss in Blumlein and spark gaps is insignificant and not exceeds 10%–12%. Most losses occur in the diode. The efficiency of energy supplied to the diode to the energy of accelerated ions is 8%–9% for a planar strip self-magnetic MID, 12%–15% for focusing diode and 20% for a spiral self-magnetic MID.

43 PARTICLE ACCELERATORS↗

Parametric-resonance ionization cooling of muon beams

Parametric-resonance Ionization Cooling (PIC) is proposed as the final 6D cooling stage of a high-luminosity muon collider. Combining muon ionization cooling with parametric resonant dynamics should allow an order of magnitude smaller final equilibrium transverse beam emittances than conventional ionization cooling alone. In this scheme, a half-integer parametric resonance is induced in a cooling channel causing the beam to be naturally focused with the period of the channel's free oscillations. Thin absorbers placed at the focal points then cool the beam's angular divergence through the usual ionization cooling mechanism where each absorber is followed by RF cavities. A special continuous-field twin-helix magnetic channel with correlated behavior of the horizontal and vertical betatron motions and dispersion was developed for PIC. We present the results of modeling PIC in such a channel using GEANT4/G4beamline. We discuss the challenge of precise beam aberration control from one absorber to another over a wide angular spread.

43 PARTICLE ACCELERATORS↗

High and low frequency instabilities driven by a single electron beam in two-electron temperature space plasmas

In an attempt to understand the excitation mechanisms of broadband electrostatic noise, beam-generated electrostatic instabilities are investigated using kinetic theory in a four-component magnetised plasma model composed of beam electrons (magnetic field-aligned), background hot and cool electrons and ions. All species are fully magnetised and considered to be Maxwellian. The dependence of the instability growth rates and real frequencies on various plasma parameters such as beam speed, particle densities and temperatures, magnetic field strength, wave propagation angle, and temperature anisotropy of the beam are examined. In this study we have found that the electron-acoustic, electron beam-resonant and ion-acoustic instabilities are excited. Our studies have focused on three velocity regimes, namely, the low (v{sub dbz} 2 C{sub h}) regimes, where v{sub dbz} (C{sub h}) is the electron beam drift speed (thermal speed of the hot electrons). Plasma parameters from satellite measurements are used where applicable to provide realistic predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion beam enhancement in magnetically insulated ion diodes for high-intensity pulsed ion beam generation in non-relativistic mode

High-intensity pulsed ion beam (HIPIB) with ion current density above Child-Langmuir limit is achieved by extracting ion beam from anode plasma of ion diodes with suppressing electron flow under magnetic field insulation. It was theoretically estimated that with increasing the magnetic field, a maximal value of ion current density may reach nearly 3 times that of Child-Langmuir limit in a non-relativistic mode and close to 6 times in a highly relativistic mode. In this study, the behavior of ion beam enhancement by magnetic insulation is systematically investigated in three types of magnetically insulated ion diodes (MIDs) with passive anode, taking into account the anode plasma generation process on the anode surface. A maximal enhancement factor higher than 6 over the Child-Langmuir limit can be obtained in the non-relativistic mode with accelerating voltage of 200–300 kV. The MIDs differ in two anode plasma formation mechanisms, i.e., surface flashover of a dielectric coating on the anode and explosive emission of electrons from the anode, as well as in two insulation modes of external-magnetic field and self-magnetic field with either non-closed or closed drift of electrons in the anode-cathode (A-K) gap, respectively. Combined with ion current density measurement, energy density characterization is employed to resolve the spatial distribution of energy density before focusing for exploring the ion beam generation process. Consistent results are obtained on three types of MIDs concerning control of neutralizing electron flows for the space charge of ions where the high ion beam enhancement is determined by effective electron neutralization in the A-K gap, while the HIPIB composition of different ion species downstream from the diode may be considerably affected by the ion beam neutralization during propagation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-324: Experimental Measurement of Optically Stimulated Luminescence Detectors in a MR-IGRT Environment Toward Assessing Magnetic Field Effects On These Devices and Their Use as An In-Vivo Dosimeter

Purpose: To characterize magnetic field effects on Optically Stimulated Luminescence Detectors (OSLDs) for use as an in-vivo dosimeter in an MRIGRT machine. Methods: Landauer OSLD nano-dots and the MicroStar II reader were used to measure and record OSLDs exposed in and on a solid water phantom in a 10.5 × 10.5 cm{sup 2} field, Co-60, 0.32-Tesla MR-IGRT machine - with and without the presence of the magnetic field. Two orthogonal gantry angles were considered to assess orientation effects on the OSLDs with respect to the incident angle of the radiation beam and magnetic field. The same OSLDs were then used (after readout and bleaching) when the magnetic field was restored. Results: The measured surface dose decreased by 14.1 ± 1.8% when magnetic field was ’on’ due to contamination electrons being swept away by the field. Doses at both 0.5 cm and 5 cm depth increased by 6.5 ± 0.9% and 8.8 ± 0.5% respectively when the magnetic field was present and the OSLDs oriented with their long axis parallel with the incident beam. This contrasts with an increased dose of 2.7 ± 1.1% when the magnetic field was present and the OSLDs were oriented with their long axis perpendicular to the incident beam. Conclusion: Previous works have shown that OSLDs have a dependence on beam incidence angle. Our current work suggests an additional dependence on the presence of the magnetic field when the beam is not perpendicular to the plane of the detector and this effect needs to be considered. Furthermore, the use of an in-vivo dosimeter was shown to have no effect on image quality during the use of MR guidance. Future work will focus on the use of an electromagnet with a linear accelerator to further characterize these effects.

60 APPLIED LIFE SCIENCES↗