Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Stock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Is the BPD Nationally Representative? A Comparison of the Building Performance Database to the Commercial Buildings Energy Consumption Survey

The Building Performance Database (BPD) contains building characteristics and energy use data that can be used to benchmark buildings against their peers. However, the BPD contains data from any source that was willing to contribute data, regardless of whether that dataset is representative of the national building stock. This report explores the representativeness of the BPD. Namely, we compared the BPD to the Commercial Buildings Energy Consumption Survey (CBECS), which was designed to be a nationally representative sample of buildings. We divided the datasets into subgroups based on building type and location, we focused on three key variables (floor area, site energy use intensity, and source energy use intensity), and we compared their statistical properties in the BPD to the CBECS. We found that while the BPD contains significantly more buildings with larger floor areas, the BPD is reasonably representative in terms of site and source energy use intensity and does not appear to have a systemic bias towards energy efficient buildings.

42 ENGINEERING↗

Establishing a commercial building energy data framework for India

Buildings account for over 40% of the world’s energy consumption and are therefore a key contributor to a country’s energy as well as carbon budget. Understanding how buildings use energy is critical to understanding how related policies may impact energy use. Data enables decision making, and good quality data arms consumers with the tools to compare their energy performance to their peers, allowing them to differentiate their buildings in the real estate market on the basis of their energy footprint. Good quality data are also essential for policy makers to prioritize their energy saving strategies and track implementation. The United States’ Commercial Building Energy Consumption Survey (CBECS) is an example of a successful data framework that is highly useful for governmental and nongovernmental initiatives related to benchmarking energy forecasting, rating systems and metrics, and more. The Bureau of Energy Efficiency (BEE) in India developed the Energy Conservation Building Code (ECBC) and launched the Star Labeling program for a few energy-intensive building segments as a significant first step. However, a data driven policy framework for systematically targeting energy efficiency in both new construction and existing buildings has largely been missing. There is no quantifiable mechanism currently in place to track the impact of code adoption through regular reporting/survey of energy consumption in the commercial building stock. In this paper we present findings from our study that explored use cases and approaches for establishing a commercial buildings data framework for India.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End Use Load Profile (EULP) of US Building Sector resulting from mass GHP retrofits

This collection of datasets describes the change (difference) in hourly energy consumption of the U.S. residential and commercial building stock while replacing existing HVAC systems with ground source heat pumps for all the balancing areas in the US, for all buildings eligible for ground source heat pump replacement. Additional county-level data may be requested from the DOE Project Lead.

15 GEOTHERMAL ENERGY↗

Evaluation of Retrofit Delivery Packages

Residential energy retrofit activities are a critical component of efforts to increase energy efficiency in the U.S. building stock; however, retrofits account for a small percentage of aggregate energy savings at relatively high per unit costs. This report by Building America research team, Alliance for Residential Building Innovation (ARBI), describes barriers to widespread retrofits and evaluates opportunities to improve delivery of home retrofit measures by identifying economies of scale in marketing, energy assessments, and bulk purchasing through pilot programs in portions of Sonoma, Los Angeles, and San Joaquin Counties, CA. These targeted communities show potential and have revealed key strategies for program design, as outlined in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Retrofit Delivery Packages

Residential energy retrofit activities are a critical component of efforts to increase energy efficiency in the U.S. building stock; however, retrofits account for a small percentage of aggregate energy savings at relatively high per unit costs. This report by Building America research team, Alliance for Residential Building Innovation (ARBI), describes barriers to widespread retrofits and evaluates opportunities to improve delivery of home retrofit measures by identifying economies of scale in marketing, energy assessments, and bulk purchasing through pilot programs in portions of Sonoma, Los Angeles, and San Joaquin Counties, CA. These targeted communities show potential and have revealed key strategies for program design, as outlined in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System Retrofits in Efficiency Programs: Track Record and Outlook

Commercial building retrofits are often limited to simple upgrades of individual building components such as equipment or lamp replacements. These equipment- or component-level retrofits have been shown to have less potential for whole building energy savings (50% less in studied cases) compared to comprehensive system-based approaches. System retrofits with their potential for much greater savings are critical to achieving aggressive energy reduction goals in the existing building stock but to date there has been little deep analysis of the track record and trends for systems retrofits in commercial buildings. This paper addresses several questions: 1. To what extent are systems retrofits taking place in the building retrofit marketplace today? 2. Do current systems retrofits in fact save more energy than component retrofits? 3. What kinds of efficiency measures are currently most prevalent in system retrofits? 4. Does systems adoption vary across different retrofit programmatic approaches (e.g. utility incentive programs, federal retrofit programs, ESCOs)? Findings, based on an analysis of retrofit data from 12,000 projects across the U.S. from custom utility incentive programs, federal retrofit programs, and Energy Service Companies (ESCOs), indicate the state of the current market with respect to adoption of systems technologies. A wide range of stakeholders were also interviewed to define the challenges and opportunities for greater deployment. A range of barriers is presented including technical and structural (i.e. programmatic, policy), along with recommendations to accelerate deployment of these strategic approaches.

Regnier, Cynthia↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Building Construction (ABC) Research Opportunities Report: Industrializing Construction to Decarbonize Buildings

The DOE Building Technologies Office generally seeks to develop, demonstrate, and accelerate the adoption of cost-effective technologies, techniques, and tools in support of an equitable transition to a decarbonized building stock and energy system by 2050. This ABC Innovations Roadmap specifically focuses on and prioritizes innovations that support the industrialization of whole building retrofits and rapid growth of efficient new construction. The content relates to the integration of technologies and industrialization of processes associated with building construction and renovation. The ABC Innovations Roadmap cross-applies innovations in both the new and existing building sectors with a focus on widescale applicability. Installation flexibility is key to commoditizing solutions that are applicable for a wide variety of buildings (e.g., different building types, vintages, architectural details, and system configurations) and to help simplify decarbonization processes for the workforce.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Informing the planning of rotating power outages in heat waves through data analytics of connected smart thermostats for residential buildings

Abstract With climate change, heat waves have become more frequent and intense. Rotating power outages happen when the power supply is unable to meet the cooling demand increase resulting from extreme high temperatures. Power outages during heat waves expose residents to high risks of overheating. In this study, we propose a novel data-driven inverse modelling approach to inform decision makers and grid operators on planning rotating power outages. We first infer the building thermal characteristics using the connected smart thermostat data, and used the estimated thermal dynamics to simulate the thermal resilience during a heat wave event. Our proposed method was tested for the California power outage in August 2020 by using the open source Ecobee Donate Your Data dataset. We found in California the power outage should not last more than two hours during heat waves to avoid overheating risks. Informing the residents in advance so they can prepare for it through pre-cooling is a simple but effective strategy to expand the acceptable power outage duration. In addition to assisting power outage planning, the proposed method can be used for other applications, such as to evaluate a building energy efficiency policy, to examine fuel poverty, and to estimate the load shifting potential of building stocks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy cost savings and expected payback for Re-tuning the controls of US Army buildings

The Headquarters Department of the Army (HQDA) sponsored a study to determine the national impact of deploying the Re-tuning™ methodology in 5 buildings types that account for over 40% of the Army’s conditioned building stock. Re-tuning is a systematic process that improves operational efficiency and reduces energy consumption at no- or low-cost through the building automation system (BAS) by correcting operational problems that plague buildings. The study relied on successful demonstration of the re-tuning methodology at 4 pilot US Army installations that informed a holistic effort that included simulating 12 individual re-tuning energy efficiency measures (EEMs) and 6 packages of EEMs in 5 selected Army building prototype models that represent 311 million ft2 (28.9 million m2) of the Army’s conditioned floor space. Both the baseline buildings and the packages were customized to capture the expected outcomes of re-tuning a diverse set of buildings. The study highlighted the benefit of individual re-tuning EEMs and economics of implementing packages of EEMs in applicable Army buildings across 16 climates and 2 building vintages. The average whole-building energy savings ranged from 10.8% to 40.5% by building type, with the company operations facility (COF) building having the highest value proposition from re-tuning. In addition, the study reveals that all large office (LO) buildings in the Army are economical to re-tune. The total modeled cost savings potential for re-tuning the five building types across the US Army is $204/1,000 sf ($220/100 m2), or $64M annually. This cost savings represents 5.6% of all the Army’s energy expenditures.

Fernandez, Nicholas EP↗

Intelligent Facades for High Performance Green Buildings. Final Technical Report

Intelligent Facades for High Performance Green Buildings: Previous research and development of intelligent facades systems has been limited in their contribution towards national goals for achieving on-site net zero buildings, because this R&D has failed to couple the many qualitative requirements of building envelopes such as the provision of daylighting, access to exterior views, satisfying aesthetic and cultural characteristics, with the quantitative metrics of energy harvesting, storage and redistribution. To achieve energy self-sufficiency from on-site solar resources, building envelopes can and must address this gamut of concerns simultaneously. With this project, we have undertaken a high-performance building- integrated combined-heat and power concentrating photovoltaic system with high temperature thermal capture, storage and transport towards multiple applications (BICPV/T). The critical contribution we are offering with the Integrated Concentrating Solar Façade (ICSF) is conceived to improve daylighting quality for improved health of occupants and mitigate solar heat gain while maximally capturing and transferring on- site solar energy. The ICSF accomplishes this multi-functionality by intercepting only the direct-normal component of solar energy (which is responsible for elevated cooling loads) thereby transforming a previously problematic source of energy into a high- quality resource that can be applied to building demands such as heating, cooling, dehumidification, domestic hot water, and possible further augmentation of electrical generation through organic Rankine cycles. With the ICSF technology, our team is addressing the global challenge in transitioning commercial and residential building stock towards on-site clean energy self-sufficiency, by fully integrating innovative environmental control systems strategies within an intelligent and responsively dynamic building envelope. The advantage of being able to use the entire solar spectrum for active and passive benefits, along with the potential savings of avoiding transmission losses through direct current (DC) transfer to all buildings systems directly from the site of solar conversion, gives the system a compounded economic viability within the commercial and institutional building markets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent Facades for High Performance Green Buildings

Progress Towards Net-Zero and Net-Positive-Energy Commercial Buildings and Urban Districts Through Intelligent Building Envelope Strategies Previous research and development of intelligent facades systems has been limited in their contribution towards national goals for achieving on-site net zero buildings, because this R&D has failed to couple the many qualitative requirements of building envelopes such as the provision of daylighting, access to exterior views, satisfying aesthetic and cultural characteristics, with the quantitative metrics of energy harvesting, storage and redistribution. To achieve energy self-sufficiency from on-site solar resources, building envelopes can and must address this gamut of concerns simultaneously. With this project, we have undertaken a high-performance building integrated combined-heat and power concentrating photovoltaic system with high temperature thermal capture, storage and transport towards multiple applications (BICPV/T). The critical contribution we are offering with the Integrated Concentrating Solar Façade (ICSF) is conceived to improve daylighting quality for improved health of occupants and mitigate solar heat gain while maximally capturing and transferring onsite solar energy. The ICSF accomplishes this multi-functionality by intercepting only the direct-normal component of solar energy (which is responsible for elevated cooling loads) thereby transforming a previously problematic source of energy into a high quality resource that can be applied to building demands such as heating, cooling, dehumidification, domestic hot water, and possible further augmentation of electrical generation through organic Rankine cycles. With the ICSF technology, our team is addressing the global challenge in transitioning commercial and residential building stock towards on-site clean energy self-sufficiency, by fully integrating innovative environmental control systems strategies within an intelligent and responsively dynamic building envelope. The advantage of being able to use the entire solar spectrum for active and passive benefits, along with the potential savings of avoiding transmission losses through direct current (DC) transfer to all buildings systems directly from the site of solar conversion, gives the system a compounded economic viability within the commercial and institutional building markets. With a team that spans multiple stakeholders across disparate industries, from CPV to A&E partners that are responsible for the design and development of District and Regional Scale Urban Development, this project demonstrates that integrating utility-scale high efficiency CPV installations with urban and suburban environments is both viable and desirable within the marketplace. The historical schism between utility scale CPV and BIPV has been one of differing scale and cultures. There is no technical reason why utility-scale CPV cannot be located within urban embedded district scale sites of energy harvesting. New models for leasing large areas of district scale roofs and facades are emerging, such that the model for utility scale energy harvesting can be reconciled to commercial and public scale building sites and campuses. This consortium is designed to unite utility scale solar harvesting into building applications for smart grid development.

14 SOLAR ENERGY↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

The Building ENergy Demand (BEND) Model: A Comprehensive Composite Building Energy Modeling Framework

The Building ENergy Demand (BEND) model was developed at Pacific Northwest National Laboratory (PNNL) to simulate climate-dependent hourly building energy demand with the ability to disaggregate down to or aggregate up to any geographic area of interest, including counties, states, electric utility service territories, and census regions. The BEND modeling framework is designed to study the effects of climate change, economics, technology advancement, and various mitigation policies on aggregate building energy demand. To make the process computationally feasible, BEND reduces granularity in building characteristics and weather forcing while maintaining enough detail to minimize systematic differences (biases) between BEND results and data from the Energy Information Administration (EIA). Based on the Commercial Building Energy Consumption Survey (CBECS) and Residential Energy Consumption Survey (RECS) databases, BEND establishes a set of representative buildings with predefined sets of building types, sizes, and vintages. These representative buildings are defined for each of the four U.S. census regions and the five climate zones used by the EIA for building surveys (hereafter “EIA climate zones”). BEND’s representative buildings are based on a statistical analysis of the CBECS and RECS databases that infers detailed parameters such as construction type, thermal properties, internal loads, equipment and mechanical systems, and operation schedules from the high-level descriptors in those databases (building type, vintage, size, and location). The representative buildings are simplified and consolidated into a set of prototype buildings for the purpose of simulating building energy demand. Combining the prototype buildings with weather files from selected locations and years, BEND creates a set of simulation-ready building models to be run using the EnergyPlus simulation engine (EnergyPlus). The base spatial unit of each BEND simulation is a subregion that is the intersection of an International Energy Conservation Code climate zone, a census region, and an EIA climate zone; analysis for each spatial unit is influenced by the weather file BEND selects to represent the climate-similar area. The major simulation outputs of interest to BEND are hourly energy consumption values for each simulated year, possibly for multiple fuel types. Based on building-stock weights derived from the CBECS/RECS data, the hourly output streams are aggregated to a single, 8760-hour load profile for each of the major building categories—residential and commercial—with the possibility of segregating by fuel types. To correct for biases inherent in the use of a limited suite of representative buildings, BEND is calibrated against observational targets of total annual building energy consumption and hourly load profiles (including peak demand) obtained for the decision-relevant geographic scales of interest (e.g., total electric load data for individual balancing authorities available from EIA). Based on available data such as population distribution, BEND is able to aggregate both up and down scales, allowing the study of building energy demand over a range of spatial scales (e.g., states or counties within the Western Electricity Coordinating Council, Eastern Interconnection, or the entire U.S.) and/or subsets of building types (e.g., office buildings with particular size ranges).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Aggregate Building Simulator (ABS) Methodology Development, Application, and User Manual

As the relationship between the national building stock and various global energy issues becomes a greater concern, it has been deemed necessary to develop a system of predicting the energy consumption of large groups of buildings. Ideally this system is to take advantage of the most advanced energy simulation software available, be able to execute runs quickly, and provide concise and useful results at a level of detail that meets the users needs without inundating them with data. The resulting methodology that was developed allows the user to quickly develop and execute energy simulations of many buildings simultaneously, taking advantage of parallel processing to greatly reduce total simulation times. The result of these simulations can then be rapidly condensed and presented in a useful and intuitive manner.

99 GENERAL AND MISCELLANEOUS↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

What does it take to “see” air leakage through a building envelope?

Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.

Boudreaux, Philip↗

Protecting building occupants against the inhalation of outdoor-origin aerosols

During normal operations, buildings can protect their occupants from outdoor airborne particle hazards of all types, including airborne pollutants. A long-term international research effort has advanced our knowledge of building protection physics. Recently we have developed an operationally efficient, regional-scale methodology - Regional Shelter Analysis - to account for both building protection effects and the typical distribution of people in and among buildings. To provide input to this capability, we estimate here the degree of protection afforded by the currently existing US building stock. Here, we first assemble and summarize the published literature relevant to indoor particle losses including (a) deposition to indoor surfaces, (b) losses that occur when particles penetrate through the building envelope, and (c) heating, ventilation and air conditioning (HVAC) system filtration efficiencies as well as general building operating conditions. Building protection against inhaling particulate hazards varies strongly, by orders of magnitude, according to particle size, airborne particle loss rate, and to a lesser extent building use (occupancy). Protection increases modestly as particle size increases from 0.1 to 1 μm and significantly as particle size increases from 1 to 10 μm. Model results are placed in context with previously reported measurements. Suggestions for future work, including enhanced validation datasets are provided.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗