Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Control of Behind-the-Meter Resources for Enhancing the Resilience of Residential Buildings

There is increased concern about the impacts of frequent power outages, caused primarily by extreme weather conditions. With increasing behind-the-meter resources such as solar photovoltaics (PV), battery energy storage, and controllable loads, these resources - if properly coordinated - can meet critical loads even during an outage. Resilience building controls can coordinate and operate these resources to enhance the resiliency of buildings supporting critical loads for longer duration. In this paper, we present two resilience building controls: rule-based control and model predictive control (MPC). We simulated various scenarios considering different locations, seasons, outage types, and times of outages to evaluate the performance of resilience controls. The results show that MPC-based control can enhance resilience up to 65% compared to rule-based control. Similarly, PV self-consumption and occupant thermal comfort both increase during outages with MPC-based control.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)

Electrical energy consumption of the residential sector is a crucial area of research that has in the past primarily focused on increasing the efficiency of household devices such as water heaters, dishwashers, air conditioners, and clothes washer and dryer units. However, the focus of this research is shifting as objectives such as developing the smart grid and ensuring that the power system remains reliable come to the fore, along with the increasing need to reduce energy use and costs. Load research has started to focus on mechanisms to support the power system through demand reduction and/or reliability services. The power system relies on matching generation and load, and day-ahead and real-time energy markets capture most of this need. However, a separate set of grid services exist to address the discrepancies in load and generation arising from contingencies and operational mismatches, and to ensure that the transmission system is available for delivery of power from generation to load. Currently, these grid services are mostly provided by generation resources. The addition of renewable resources with their inherent variability can complicate the issue of power system reliability and lead to the increased need for grid services. Using load as a resource, through demand response programs, can fill the additional need for flexible resources and even reduce costly energy peaks. Loads have been shown to have response that is equal to or better than generation in some cases. Furthermore, price-incentivized demand response programs have been shown to reduce the peak energy requirements, thereby affecting the wholesale market efficiency and overall energy prices. The residential sector is not only the largest consumer of electrical energy in the United States, but also has the highest potential to provide demand reduction and power system support, as technological advancements in load control, sensor technologies, and communication are made. The prevailing loads based on the largest electrical energy consumers in the residential sector are space heating and cooling, washer and dryer, water heating, lighting, computers and electronics, dishwasher and range, and refrigeration. As the largest loads, these loads provide the highest potential for delivering demand response and reliability services. Many residential loads have inherent flexibility that is related to the purpose of the load. Depending on the load type, electric power consumption levels can either be ramped, changed in a step-change fashion, or completely removed. Loads with only on-off capability (such as clothes washers and dryers) provide less flexibility than resources that can be ramped or step-changed. Add-on devices may be able to provide extra demand response capabilities. Still, operating residential loads effectively requires awareness of the delicate balance of occupants health and comfort and electrical energy consumption. This report is Phase I of a series of reports aimed at identifying gaps in automated home energy management systems for incorporation of building appliances, vehicles, and renewable adoption into a smart grid, specifically with the intent of examining demand response and load factor control for power system support. The objective is to capture existing gaps in load control, energy management systems, and sensor technology with consideration of PHEV and renewable technologies to establish areas of research for the Department of Energy. In this report, (1) data is collected and examined from state of the art homes to characterize the primary residential loads as well as PHEVs and photovoltaic for potential adoption into energy management control strategies; and (2) demand response rules and requirements across the various demand response programs are examined for potential participation of residential loads. This report will be followed by a Phase II report aimed at identifying the current state of technology of energy management systems, sensors, and communication technologies for demand response and load factor control applications for the residential sector. The purpose is to cover the gaps that exist in the information captured by the sensors for energy management system to be able to provide demand response and load factor control. The vision is the development of an energy management system or other controlling enterprise hardware and software that is not only able to control loads, PHEVs, and renewable generation for demand response and load factor control, but also to do so with consumer comforts in mind and in an optimal fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CDL2PLC translator v0.1.0

The CDL-PLC translator aims at translating control sequences for building energy systems from the CDL CXF format to the PLCopen XML format. The CDL CXF developed at LBL within the OpenBuildingControl project, and now being standardized via ASHRAE Standard 231P, enables expressing control sequences developed in the simulation environment Modelica in a JSON format. The PLCopen XML is an existing exchange format standardized in IEC 61131-10 for Programmable Logic Controllers (PLCs) following the IEC 61131 standard as one target system of CDL among others. The translation from the CDL CXF to the PLCopen XML contributes to a seamless workflow from the model-based development of control sequences in simulation environments, which is not building practice today, and their digital implementation on building controllers, which replaces graphical and textual documents used for this purpose today. The translator is at a prototypical stage and enables, as a proof of concept, the translation of very simple control sequences composed of 4 selected function blocks out of 137 function blocks defined in CDL. The translation includes the connection of inputs and outputs of function blocks and the expression of a control function in CDL to the equivalent code in IEC 61131-3.

Walther, Karl↗

Measuring OutdoorAir Intake Rates Using Electronic Velocity Sensors at Louvers and Downstream of Airflow Straighteners

Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100percent, and were often greater than 25percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systems and methods for controlling energy use in a building management system using energy budgets

Systems and methods for limiting power consumption by a heating, ventilation, and air conditioning (HVAC) subsystem of a building are shown and described. A feedback controller is used to generate a manipulated variable based on an energy use setpoint and a measured energy use. The manipulated variable may be used for adjusting the operation of an HVAC device.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an Assessment Method for Radiation Exposure from NORM in Construction Materials - 19032

Once radiological impact is usually considered to be related to nuclear energy accidents and atomic bombs, most of the research on radiation protection has been focused on artificial radionuclides and radioactive waste. Less attention had been given to radiation exposure due to the presence of naturally occurring radioactive materials in raw materials usually considered as not radioactive and used in manufacturing of many building materials. At national level, radiological data from building materials is not available as the control of building materials regarding the content of naturally occurring radionuclides is addressed for the first time in the EU Directive 2013/59/EURATOM. At international level the research developed is largely incomplete: data on the activity concentration measurements of Ra-226, Th-232 and K-40 in building materials used in the construction industry in the EU is non-statistically representative. The data collected are not enough to have an idea of the European situation, but they confirm high concentration of Ra-226, Th-232 and K-40, in some cases. Moreover, most of the research studies carried out in the EU are based on the assessment of the activity concentration index, which was derived for practical monitoring purposes to identify whether a dose criterion is met; to be used only as a screening tool for identifying materials which might be of concern. The dose criterion considers only effective dose due to γ-radiation, but population at home is also exposed to Rn-222 (and Rn-220) from soil, water and building material itself, sometimes to β radiation from superficial materials, and even to Cs-137 from some types of wood. The indoors exposure can be actually much higher than the value assessed with the dose criterion method. Also, in most cases toxic and radioactive components are inseparably. Therefore, all technical questions related to the toxic part of these materials should be addressed: an integrated approach is needed to assess the impacts of using these materials (new materials, recyclates and by-products). Until recently, radiation from natural sources seemed both unremarkable and unalterable - a background phenomenon. It is now known that doses from natural sources and in particular, decay products of radon can be remarkably high within houses in some areas. Therefore, concerning exposure to natural radiation sources, special provisions have been laid down in the EU Directive 1996/28 EURATOM. Still, the radiological evaluation of building materials was not mandatory in this Directive. The most recent EU Directive 2013/59/EURATOM brings some changes concerning the exposure to natural occurring radioactive materials but the previous screening method was kept. An effective dose of 1 mSv/year was set, as a basis for the exposure to radionuclides of natural origin (except for radon). This work seeks to develop an integrated radiological and chemical-mineralogical assessment methodology for realistic exposure scenarios concerning different types of raw materials, by-products and recyclates and used as building materials. The methodology includes the characterization of selected materials accounting for radiological exposure - calculation of effective dose; toxicity assessment - determination of chemical composition and leaching tests, study of changes in the microstructure and consequently in the radon emanation coefficient. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alfalfa

Alfalfa-based testbeds enable building equipment, control products, and workforce development tools to interact with dynamic building simulations representing the desired building, system, weather, and grid configuration. Alfalfa is used to de-risk implementation of load flexibility prior to field deployment, reducing the costs and timelines associated with adoption of decarbonization technology at the grid edge.

building energy modeling↗

HVAC Controls Guide for Plan Examiners and Building Inspectors

The information in this guide will make it easier to understand, apply, and validate compliance with heating, ventilation, and air-conditioning (HVAC) control requirements found in building energy codes .HVAC controls are a key driver of building performance from both energy and comfort standpoints, the latter of which impacts productivity, sales, and the general success of the activities in the buildings. Ensuring compliance with HVAC control requirements in the energy codes can be a challenging task; controls can be difficult to identify on plans and their proper installation and functionality are a challenge to assess in the field. The guide addresses requirements defined by the 2009 and 2012 IECC and the 2007 and 2010 editions of ASHRAE Standard 90.1, which are common bases for codes adopted by state and local jurisdictions.

HVAC, IECC, code compliance, thermostat, humidity↗

Implementation of Energy Code Controls Requirements in New Commercial Buildings

This study used a three-step process to evaluate the degree to which high-impact controls requirements included in commercial energy codes are realizing their savings potential. The three-step process included: (1) interviews of commissioning agents; (2) field audits of a sample of commercial buildings to determine how well control measures are being designed, commissioned and correctly implemented; and (3) analysis of the information gathered.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Recent Research and Application on Seismic Isolation, Energy Dissipation and Control for Structures in China

This paper briefly introduces the recent research, testing analysis, design and application on seismic isolation, energy dissipation, tuned mass damper and active control for buildings and bridges in mainland China. Paper introduces some typical researches, testing and analysis, including the mechanical tests for bearings and control devices, and the shaking table tests for structural models with different control systems. Paper also introduces the Chinese design codes for structures with seismic isolation and energy dissipation. Paper describes the recent application status and typical examples, especially introduces the largest isolation buildings group in the world, and the using passive and semi active control for structures. Also the paper makes discussion some problems existed on passive and active control technique now and the tendency of development on seismic control in future.

58 GEOSCIENCES↗

Towards Digital and Performance-Based Supervisory HVAC Control Delivery

Upgrading supervisory HVAC control in commercial buildings is one of the most attractive decarbonization tools at our disposal. Modern controls are software programs and can in theory be deployed at scale and with a low up-front carbon "pulse". In practice, however, control delivery is a disjointed and inefficient process, dominated by manual handoffs of imprecise English language documents. A particularly high barrier exists between control implementation and building energy modeling (BEM) which results in control sequences typically not being tested for correctness or performance before implementation. Together with industry partners, DOE and the national labs are developing an ecosystem of tools and standards that can support fully digital performance-based control delivery workflows. This paper describes this ecosystem, which consists of three mutually supportive efforts. Semantic models of buildings and their systems enable automatic configuration and installation of control software. Platform-neutral control descriptions separate control algorithms from control platforms and enable the creation of libraries of reference control implementations. Dynamic whole-building energy-control simulation that can execute physically realistic control sequences makes it possible to test and evaluate the performance of control sequences and then directly compile them for installation and execution in control systems. In addition to digitizing and streamlining project-level control delivery, these standards and related software support benchmarking of control algorithms, both rule-based and optimization-based, and help to both advance the state of the art and to implement ratings and programs that encourage the adoption of high-performance control.

building controls↗

Developing Smart Building Technology Modules to Enhance Workforce Preparedness: A Case for AI-Driven Academic and Professional Education

Smart building technologies are resources that improve building energy efficiency and resilience, reduce carbon emissions, and provide load flexibility to the grid. However, in both academic curricula and building professionals’ continuing education, there is a lack of systematic instruction on methods to integrate multiple energy systems including distributed energy resources (DER), smart building technologies, AI (Artificial Intelligence) tools and key concepts, components, and controls, including “Internet of Things” (IoT) devices. In today’s dynamic workforce, this major gap in smart building technology education prevents stakeholders from being able to attract talent with an understanding and preparation to adopt smart building technologies in building design and operations. A federally funded project included a partnership between Slipstream and Texas A&M University (TAMU) to develop a semester-long smart building curriculum for engineering college students with the ability to adapt the contents for workforce development of professionals in building services. The final product consists of 16 training videos adapted for building professionals and the public. The educational content and training materials cover the benefits of building energy systems, the latest sensor technologies and IoT devices, all with a focus on smart building technologies. The key drivers are on topics related to smart building controls (i.e., energy management information systems), smart building control platforms, cybersecurity, grid-interactive-efficient buildings (GEBs), smart building control methods, and occupant-centric control. Although not explicitly included the technologies nod to the need for AI driven technologies to prepare engineers and industry professionals to be future ready. This paper describes the project approach, provides outlines of the training materials, and identifies lessons learned in creating the content for this course. The authors suggest ways to scale the instruction of smart building concepts to empower the workforce to accelerate the adoption of smart building technologies and AI-based teaching and learning in higher education and building sector.

99 GENERAL AND MISCELLANEOUS↗

Energy cost savings and expected payback for Re-tuning the controls of US Army buildings

The Headquarters Department of the Army (HQDA) sponsored a study to determine the national impact of deploying the Re-tuning™ methodology in 5 buildings types that account for over 40% of the Army’s conditioned building stock. Re-tuning is a systematic process that improves operational efficiency and reduces energy consumption at no- or low-cost through the building automation system (BAS) by correcting operational problems that plague buildings. The study relied on successful demonstration of the re-tuning methodology at 4 pilot US Army installations that informed a holistic effort that included simulating 12 individual re-tuning energy efficiency measures (EEMs) and 6 packages of EEMs in 5 selected Army building prototype models that represent 311 million ft2 (28.9 million m2) of the Army’s conditioned floor space. Both the baseline buildings and the packages were customized to capture the expected outcomes of re-tuning a diverse set of buildings. The study highlighted the benefit of individual re-tuning EEMs and economics of implementing packages of EEMs in applicable Army buildings across 16 climates and 2 building vintages. The average whole-building energy savings ranged from 10.8% to 40.5% by building type, with the company operations facility (COF) building having the highest value proposition from re-tuning. In addition, the study reveals that all large office (LO) buildings in the Army are economical to re-tune. The total modeled cost savings potential for re-tuning the five building types across the US Army is $204/1,000 sf ($220/100 m2), or $64M annually. This cost savings represents 5.6% of all the Army’s energy expenditures.

Fernandez, Nicholas EP↗

Incipient Sensor Fault Impacts on Building Performance Through HVAC Controls: A Pilot Study

Sensors are crucial input components for HVAC controls. Studies show faults are common for buidings and HVAC systems. Sensors with faults will compromise the control perfrormance regardless how advanced of the control algorithms. Majority studies assume the sensor fault to be constant the whole year. In reality, the sensor faults might evolve or develop with time, which is essentially the incipient (i.e. evolving) fault. The incipient sensor faults impacts remain a research gap. This study aims to investigate the incipient sensor fault impacts to control sequences of multi-zone VAV boxes and AHU system following the ASHRAE Guideline 36-2018: High-Performance Sequences of Operation.

Li, Yanfei↗

Building Materials Property Table

This information sheet describes a table of some of the key technical properties of many of the most common building materials taken from ASHRAE Fundamentals - 2001, Moisture Control in Buildings, CMHC, NRC/IRC, IEA Annex 24, and manufacturer data.

Building Science Corporation↗

Solar+ Optimizer: A Model Predictive Control Optimization Platform for Grid Responsive Building Microgrids

With the falling costs of solar arrays and battery storage and reduced reliability of the grid due to natural disasters, small-scale local generation and storage resources are beginning to proliferate. However, very few software options exist for integrated control of building loads, batteries and other distributed energy resources. The available software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice, and are often incapable of operating independently of the grid during blackouts. In this paper, we present the “Solar+ Optimizer” (SPO), a control platform that provides demand flexibility, resiliency and reduced utility bills, built using open-source software. SPO employs Model Predictive Control (MPC) to produce real time optimal control strategies for the building loads and the distributed energy resources on site. SPO is designed to be vendor-agnostic, protocol-independent and resilient to loss of wide-area network connectivity. The software was evaluated in a real convenience store in northern California with on-site solar generation, battery storage and control of HVAC and commercial refrigeration loads. Preliminary tests showed price responsiveness of the building and cost savings of more than 10% in energy costs alone.

14 SOLAR ENERGY↗