Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

High-Resolution Mass Spectrometry Quantification: Impact of Differences in Data Processing of Centroid and Continuum Data

High-resolution mass spectrometry (HRMS) in full scan mode acquires all ions present in the sample of interest offering a lot of qualitative information. This, in combination with the improved performance of the new generation HRMS systems, triggers more (bio) analysts to switch from triple quad MS systems to HRMS for quantitative analysis. Quantitative processing of HRMS data is performed based on narrow mass extraction windows rather than on nominal mass product ion chromatograms (SRM or MRM). Optimal processing of HRMS data requires different considerations and software tools and can have an impact on data processing and final results. The selection of centroid versus continuum/profile data for processing, selection of the optimal narrow mass extraction window, using theoretical versus measured accurate mass for the extraction of the ion chromatograms as well as differences in calculations and data handling residing in the different vendor software packages are tackled in the presented manuscript. These differences are illustrated on HRMS data acquired for the same plasma samples on three different platforms, i.e., a Sciex QToF, a Waters QToF, and a Thermo Orbitrap system, and processed in four different software packages, i.e., Sciex Analyst® TF, Waters Masslynx, Waters Unifi, and Thermo Xcalibur. The impact of these differences on quantitative HRMS performance was evaluated on calibration curves of eight small molecule compounds in plasma using four different ways of processing. Simple guidelines are provided for the selection of an optimal mass extraction window for continuum and centroided data. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal conductivity measurement using modulated photothermal radiometry for nitrate and chloride molten salts

Molten salts are being used or explored for thermal energy storage and conversion systems in concentrating solar power and nuclear power plants. Thermal conductivity of molten salts is an important thermophysical property dictating the performance and cost of these systems, but its accurate measurement has been challenging, as evidenced by wide scattering of existing data in literature. The corrosive and conducting nature of these fluids also leads to time consuming sample preparation processes of many contact-based measurements. Here, in this work, we report the measurement of thermal conductivity of molten salts using a modulated photothermal radiometry (MPR) technique, which is a laser-based, non-contact, frequency-domain method adopted for molten salts for the first time. By unitizing the advantages of front side sensing of frequency-domain measurements and the vertical holder orientation, the technique can minimize the natural convection and salt creeping effects, thus yielding accurate molten salt thermal conductivity . The MPR technique is first calibrated using standard molten materials including paraffin wax and sulfur. It is then applied on measuring pure nitrate salts (NaNO 3 and KNO 3 ), solar salt (NaNO 3 –KNO 3 mixture), and chloride salt (NaCl–KCl–MgCl 2 ). The measurement results are compared with data from literature, especially those obtained from laser flash analysis (LFA). Our results demonstrate that the MPR is a convenient and reliable technique of measuring thermal conductivity of molten salts. Accurate thermal conductivity data of molten salts will be valuable in developing the next-generation high-temperature thermal energy storage and conversion systems.

14 SOLAR ENERGY↗

Synthesis and magnetic characterization of Sr-based Ni{sub 2}X-type hexaferrite

We have investigated the synthesis conditions, and the magnetic properties of the Sr{sub 2}Ni{sub 2}X-type hexagonal ferrite, Sr{sub 2}Ni{sub 2}Fe{sub 28}O{sub 46}. The Sr{sub 2}Ni{sub 2}X-type hexaferrite was synthesized at 1240{sup ∘}C. The spontaneous magnetization at 5 K was 44.2 μ{sub B}/f.u., suggesting that most of the Ni{sup 2+} ions are at the up-spin octahedral sites in the spinel-structure blocks within the model of a Néel-type collinear ferrimagnetic structure. The Curie temperature of the Sr{sub 2}Ni{sub 2}X-type hexaferrite was estimated to be T{sub C}[Sr{sub 2}Ni{sub 2}X] = 472{sup ∘}C. This is consistent with the difference of the block stacking structures of SrM-type, Sr{sub 2}Ni{sub 2}X-type, SrNi{sub 2}W-type, and nickel spinel ferrites.

36 MATERIALS SCIENCE↗

Use of the Hugoniot Elastic Limit in Laser Shockwave Experiments to Relate Velocity Measurements

---The Idaho National Laboratory (INL) has been developing a Laser Shock system to characterize interface strength in plate fuel for research reactors around the world [1]. This work is in support of the Unites states High Performance Research Reactor program whose goal is to reduce the risk of proliferation of weapons grade fuel while maintaining reactor performance. The INL has been working with National Research Council Canada (NRC) on this project for the last five years. ---One of the concerns of the project is the difficulty of calibrating and standardizing the laser shock technique. The generation of the stress wave by the laser impinging on the plate surface is complex, with amplitude and shape dependence on numerous factors relating to the temporal and spatial distribution of power in the laser spot, surface treatment, and material properties of the plate. Thus the resulting back-face surface velocity, which is used to measure the time-varying stress field within the plate, is difficult to reproduce across different measurement systems. A technique that can generate or indicate a known shock intensity independent of the generating conditions would be valuable and allow us to directly compare results from different systems. ---A Laser Shock round robin test between the system at NRC and the INL was conducted. The goal of the round robin was to determine if there was any bias between the two systems. During the analysis of the data, it was noted that the Hugoniot Elastic Limit (HEL) was consistent within both system data sets independent of the laser power used. An analytical study under development supports that the HEL in metals could be a robust and simple benchmark to compare stresses generated by different laser shock systems. The HEL is a material property that should be insensitive to differences in the shock laser and surface preparation which enhances the reliability of the resulting HEL velocity measurement. 1. J. M. Lacy, J. A. Smith and B. H. Rabin, "Developing a Laser Shockwave Model for Characterizing Diffusion Bonded Interfaces," The 41st Annual Review of Progress in Quantitative Nondestructive Evaluation," Boise, ID, U.S.A., July 2014.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Further Investigation of Surface Velocity Measurements for Material Characterization in Laser Shockwave Experiments

Further investigation of surface velocity measurements for material characterization in laser shockwave experiments James A. Smith, Jeffrey M. Lacy, Clark L. Scott, Bradley C. Benefiel Idaho National Laboratory, Idaho Falls ID Daniel Levesque, Jean-Pierre Monchalin and Martin Lord, National Research Council Canada, Boucherville, QC, Canada ---As part of the US High Performance Research Reactor program, a laser shockwave system is being developed by the Idaho National Laboratory (INL) to characterize interface strength in innovative plate fuel for research reactors around the world. The INL has been working with National Research Council Canada (NRC) on this project for the last five years. One of the concerns is the difficulty of calibrating and standardizing the laser shock technique. The generation of a stress wave by the laser impinging on the plate surface is dependent on the surface preparation, temporal and spatial power distribution of the laser spot, and material properties of the plate. Thus the resulting back surface velocity used to measure the time-varying stress field within the plate is difficult to reproduce across different measurement systems. ---A recent analytical study and testing support the use of the Hugoniot Elastic Limit (HEL) in materials as a robust and simple benchmark to compare stresses generated by different laser shock systems [1]. Using a non-contact laser velocimeter based on a solid Fabry-Perot etalon, the systems at NRC and INL showed that the velocity reached at the HEL is consistent, independent of the laser power used. In this work, the laser velocimeter of the NRC system is tested against a fast rotating wheel to verify accuracy and determine best operating conditions. A round robin test between the two laser shock systems on plates of different Al alloys is presented that shows the correct classification of the Al alloys based on the HEL as well as determining the bias between the systems. Also the effects of some setup parameters on other characteristics of the surface velocity and corresponding stress wave are discussed. 1. J.A. Smith, J.M. Lacy, D. Levesque, J.-P. Monchalin and M. Lord, "Use of the Hugoniot elastic limit in laser shockwave experiments to relate velocity measurements, 42nd Annual Review of Progress in Quantitative Nondestructive Evaluation, AIP Conf. Proc. 1706, pp. 080005-1-080005-10, 2016.

36 MATERIALS SCIENCE↗

Comparing the shock sensitivity of insensitive energetic materials

We present a tabletop method to study the shock sensitivity of plastic-bonded explosives that are considered shock insensitive using high dynamic range optical emission spectroscopy with laser-launched km/s flyer plate impacts (2, 3, and 4 km/s), which measures the spectral radiance (the emission spectrum vs a calibrated intensity standard) every 0.8 ns in the nanosecond and microsecond regimes. The explosives were TATB (1,3,5 trinitro, 2,4,6 triamino benzene), FOX-7 (1,1-diamino-2,2-dinitroethylene), LLM-105 (2,6-diamino-3,5-dinitropyrazine-1-oxide), and NTO (nitrotriazolone), all with 20% Sylgard 182 binder. Time resolving emission from shocked explosives produces a unique fingerprint at each shock pressure, and the emission temporal profile can be used to understand each material's shock response and the underlying mechanisms within the framework of the well-known shock ignition and growth models. Ignition was characterized by the emission intensity during nanosecond hot spot ignition. The growth process, which occurs after the shock has unloaded, was characterized by the time derivative of microsecond emission intensity. Singular-value decomposition was used to determine a characteristic spectral radiance over the entire time range, and this radiance was fit to a graybody model to determine a characteristic temperature Tc. Even though these insensitive explosives have similar shock sensitivities, our method can clearly distinguish their shock response. FOX-7 and NTO were the most sensitive, with FOX-7 having the greatest shock ignition sensitivity, growth rate, and Tc. LLM-105 was much less sensitive than FOX-7 and NTO, and TATB consistently showed the lowest sensitivity by any measure.

Akhtar, Meysam (ORCID:0000000243897837)↗

Improvements in optical metrology for high-performance variable-line-spacing x-ray gratings

Here, we discuss a project to develop a precision metrology system for variable-line-spacing x-ray gratings using interferometric microscopes. We are developing test standards and calibration techniques to measure and correct for geometrical distortion and blur, and data processing techniques to combine multiple measurements and measure line spacing with high accuracy.

Calibration methods↗

Bayesian Treed Calibration: An Application to Carbon Capture With AX Sorbent

In cases where field or experimental measurements are not available, computer models can model real physical or engineering systems to reproduce their outcomes. They are usually calibrated in light of experimental data to create a better representation of the real system. Statistical methods, based on Gaussian processes, for calibration and prediction have been especially important when the computer models are expensive and experimental data limited. In this paper, we develop the Bayesian treed calibration (BTC) as an extension of standard Gaussian process calibration methods to deal with non-stationarity computer models and/or their discrepancy from the field (or experimental) data. Our proposed method partitions both the calibration and observable input space, based on a binary tree partitioning, into sub-regions where existing model calibration methods can be applied to connect a computer model with the real system. The estimation of the parameters in the proposed model is carried out using Markov chain Monte Carlo (MCMC) computational techniques. Different strategies have been applied to improve mixing. We illustrate our method in two artificial examples and a real application that concerns the capture of carbon dioxide with AX amine based sorbents. The source code and the examples analyzed in this paper are available as part of the supplementary materials.

Bayesian tree↗

Melting and transport properties of Al 2⁢ O 3 at extreme conditions

The high-pressure, temperature phase diagram and transport properties of materials are of broad interest to planetary sciences and high-energy-density sciences and applications. Alumina (Al 2 O 3 ) or its various forms (e.g., solutions with other oxides or silicates) are important constituents in Earth’s and super-Earths’ mantles, common window materials in dynamic compression experiments, and standard pressure calibrators in diamond-anvil-cell experiments. Its structures and transport properties are of particular importance but have not been well studied at above 100 GPa pressures. Based on extensive first-principles molecular dynamics calculations, we obtain atomic level insights on structural differences and accurate results on electrical conductivity (σ dc ), thermal conductivity (κ), and reflectivity of Al 2 O 3 in several phases at pressures of ~130–1300 GPa and temperatures of 4000–20,000 K. We find the solid-to-liquid state changes of Al 2 O 3 are accompanied by an insulator-to-semimetal transition with enhanced σ dc and κ, which is similar to other silicates and oxides and can facilitate magnetic field generation in deep interiors of rocky planets. We also find the solid-to-solid transition (from Rh 2 O 3 (II) to CaIrO 3 ) is accompanied by negligible changes in σ dc and κ at 160 GPa, contrary to previous expectations, whereas another higher pressure phase transition (CaIrO 3 to U 2 S 3 at 450 GPa) is associated with increases in σ dc and κ. Furthermore, we show the transport properties can be enhanced by oxygen vacancy in Al 2 O 3 , but are not significantly affected by forming solutions with MgSiO 3 , particularly when in the solid states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-T-322: A Comparison of Two Si Detectors for in Vivo Dosimetry

Purpose: To compare two types of semiconductor detectors for in vivo dosimetry by their dependence from various parameters in different conditions. Methods: QED yellow (Sun Nuclear) and EDP (Scanditronix) Si detectors were radiated by a Varian Clinac 2300 ix with 6 and 18 MV energies. 10 cm thickness water equivalent phantom consisted of 30×30 cm{sup 2} squared plates was used for experiments. Dose dependencies for different beam angles (0 – 180°), field size (3–40 cm), dose (50 – 300 MU), and dose rates (50 – 300 MU/min) were obtained and calibrated with Standard Farmer chamber (PTW). Results: Reproducibility, linearity, dose rate, angular dependence, and field size dependence were obtained for QED and EDP. They show no dose-rate dependence in available clinical dose rate range (100–600 MU/min). Both diodes have linear dependence with increasing the dose. Therefore even in case of high radiation therapy (including total body irradiation) it is not necessary to apply an additional correction during in vivo dosimetry. The diodes have different behavior for angular and field size dependencies. QED diode showed that dose value is stable for beam angles from 0 to 60°, for 60–180° correction factor has to be applied for each beam angle during in vivo measurements. For EDP diode dose value is sensitive to beam angle in whole range of angles. Conclusion: The study shows that QED diode is more suitable for in vivo dosimetry due to dose value independence from incident beam angle in the range 0–60°. There is no need in correction factors for increasing of dose and dose rate for both diodes. The next step will be to carry out measurements in non-standard conditions of total body irradiation. After this modeling of these experiments with Monte Carlo simulation for comparison calculated and obtained data is planned.

60 APPLIED LIFE SCIENCES↗

Measuring SNM Isotopic Distributions using FRAM

The first group of slides provides background information on the isotopic composition of plutonium. It is shown that 240 Pu is the critical isotope in neutron coincidence/multiplicity counting. Next, response function analysis to determine isotopic composition is discussed. The isotopic composition can be determined by measuring the net peak counts from each isotope and then taking the ratio of the counts for each isotope relative to the total counts for the element. Then FRAM (Fixed energy Response function Analysis with Multiple efficiencies) is explained. FRAM can control data acquisition, automatically analyze newly acquired data, analyze previously acquired data, provide information on the quality of the analysis, and facilitate analysis in unusual situations (non-standard energy calibrations, gamma rays from non-SNM isotopes, poor spectra (within limits)).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Closeout Briefing for PSL Technical Survey of MSTS SCP (JASPER) [PowerPoint]

NNSA Order 56XB (Chapter 13.2) requires the Primary Standards Laboratory (PSL) to perform technical surveys on the integrated contractors participating in the NNSA Standards and Calibration Program. In addition to Chapter 13.2, the surveys check for compliance with ISO/IEC 17025 and the PSLM. The PSL Technical Survey is a joint activity of the NNSA and the PSL. The PSL is responsible for the technical portion of the survey and the NNSA is responsible for the quality portion. The Technical Survey report is issued by the NNSA.

42 ENGINEERING↗

Enabling Efficient Surveillance, Control, and Automation of Geothermal Operations with Advanced Predictive Analytics

Automation and control of geothermal energy production and operations require reliable and efficient predictive tools. While physics-based simulation offers a comprehensive tool for predicting energy production performance in geothermal systems, predicting the behavior of geothermal reservoirs involves complex multi-physics processes with coupling effects, highly uncertain input parameters and subsurface descriptions. Moreover, building, running, and integrating simulation models into standard model calibration and optimization workflows entail significant technical and computational efforts. An emerging alternative to physics-based simulation is data-driven predictive analytics models that have gained popularity in energy industry. In this report, we develop novel predictive models for integration into real-time fault diagnosis and model predictive control algorithms to improve the efficiency of energy production operations in geothermal reservoirs. The report includes two major research Thrust Areas, that is, the surface power plant and the subsurface reservoir.

15 GEOTHERMAL ENERGY↗

Synchrotron X-ray Microdiffraction and Fluorescence Imaging of Mineral and Rock Samples

In this paper, we describe a detailed procedure for acquiring and processing x-ray microfluorescence (μXRF), and Laue and powder microdiffraction two-dimensional (2D) maps at beamline 12.3.2 of the Advanced Light Source (ALS), Lawrence Berkeley National Laboratory. Measurements can be performed on any sample that is less than 10 cm x 10 cm x 5 cm, with a flat exposed surface. The experimental geometry is calibrated using standard materials (elemental standards for XRF, and crystalline samples such as Si, quartz, or Al 2 O 3 for diffraction). Samples are aligned to the focal point of the x-ray microbeam, and raster scans are performed, where each pixel of a map corresponds to one measurement, e.g. , one XRF spectrum or one diffraction pattern. The data are then processed using the in-house developed software XMAS, which outputs text files, where each row corresponds to a pixel position. Representative data from moissanite and an olive snail shell are presented to demonstrate data quality, collection, and analysis strategies.

36 MATERIALS SCIENCE↗

Cosmology Large Angular Scale Surveyor (CLASS): 90 GHz Telescope Pointing, Beam Profile, Window Function, and Polarization Performance

The Cosmology Large Angular Scale Surveyor (CLASS) is a telescope array that observes the cosmic microwave background (CMB) over ∼75% of the sky from the Atacama Desert, Chile, at frequency bands centered near 40, 90, 150, and 220 GHz. CLASS measures the large angular scale CMB polarization to constrain the tensor-to-scalar ratio and the optical depth to last scattering. This paper presents the optical characterization of the 90 GHz telescope. Observations of the Moon establish the pointing while dedicated observations of Jupiter are used for beam calibration. The standard deviations of the pointing error in azimuth, elevation, and boresight angle are 1$^{'}_.$3, 2$^{'}_.$1, and 2$^{'}_.$0, respectively, over the first 3 yr of observations. This corresponds to a pointing uncertainty ∼7% of the beam’s full width at half-maximum (FWHM). The effective azimuthally symmetrized instrument 1D beam estimated at 90 GHz has an FWHM of 0$^°_.$620 ± 0$^°_.$003 and a solid angle of 138.7 ± 0.6(stats.) ± 1.1(sys.) μsr integrated to a radius of 4°. The corresponding beam window function drops to $b^2_ℓ$ = 0.93, 0.71, 0.14 at ℓ = 30, 100, 300, respectively. Far-sidelobes are studied using detector-centered intensity maps of the Moon and measured to be at a level of 10 −3 or below relative to the peak. The polarization angle of Tau A estimated from preliminary survey maps is 149°.6 ± 0°.2(stats.) in equatorial coordinates. The instrumental temperature-to-polarization (T → P) leakage fraction, inferred from per-detector demodulated Jupiter scan data, has a monopole component at the level of 1.7 × 10 −3 , a dipole component with an amplitude of 4.3 × 10 −3 , with no evidence of quadrupolar leakage.

79 ASTRONOMY AND ASTROPHYSICS↗

Fraunhofer line-dept sensing applied to water

An experimental Fraunhofer line discriminator is basically an airborne fluorometer, capable of quantitatively measuring the concentration of fluorescent substances dissolved in water. It must be calibrated against standards and supplemented by ground-truth data on turbidity and on approximate vertical distribution of the fluorescent substance. Quantitative use requires that it be known in advance what substance is the source of the luminescence emission; qualitative sensing, or detection of luminescence is also possible. The two approaches are fundamentally different, having different purposes, different applications, and different instruments. When used for sensing of Rhodamine WT dye in coastal waters and estuaries, the FLD is sensing in the spectral region permitting nearly maximum depth of light penetration.

Stoertz, G. E.↗