Search NASA⌕ Search

SEARCH · Search NASA

Results for “CFD Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

HydroChrono: An Open-Source Hydrodynamics Package for Project Chrono

In this paper we present the development and verification of HydroChrono, a hydrodynamics package for the Project Chrono physics engine. This package includes the implementation of hydrodynamics equations, the added mass for multibody systems, the development of I/O functions as well as a Python API, and comparison against standard reference cases and other existing tools. HydroChrono provides a flexible, fully open-source solution for simulating wave energy converters (WECs), floating offshore wind turbines (FOWTs) platforms, and other hydrodynamic systems. Here we show, via comparisons with existing tools for benchmark verification cases, that HydroChrono accurately models hydrodynamic forces - making it a useful tool for the design and optimization of these systems. Additionally, the integration of HydroChrono with Project Chrono offers access to finite element modeling capabilities and high-fidelity modelling - with Chrono's existing coupling to CFD and SPH codes. This provides numerical modelers with a multifidelity simulation framework for designing and validating these systems. The development of HydroChrono provides a new, open-source solution for simulating hydrodynamic systems. Its compatibility with other simulation tools enables a more streamlined and efficient design process, advancing the field and providing new opportunities for innovation in this area.

BEM↗

Fuel-air mixing in motored CFR engine at research octane number (RON) relevant condition

This paper presents a three-dimensional (3-D) computational fluid dynamics (CFD) study of a motored cooperative fuel research (CFR) engine at research octane number (RON) relevant condition. The boundary conditions for 3-D simulations were generated with a one-dimensional GT-Power model. For the first time in literature, a carburetor was added to a virtual CFR engine model with 3-D CFD. Therefore, the proposed setup can simulate the fuel and thermal stratifications inside the engine cylinder with realistic detail. The transient simulations in this work were performed within the Reynolds-averaged Navier-Stokes (RANS) framework with a Realizable k-ε turbulence model. Major conclusions from the present work are: (1) The in-cylinder flow of the CFR engine is swirl-dominated due to the existence of the intake valve shroud. (2) There is a significant amount of liquid droplets entering the cylinder during the intake stroke. The maximum instantaneous amount of liquid for 50% PRF 87 (containing 87% iso-octane and 13% n-heptane (v/v)) and 50% ethanol mixture is indicated to be around 26% of total injected fuel mass. (3) The heat of vaporization (HoV) of the fuel is responsible for creating both temperature and charge stratification inside the cylinder.

33 ADVANCED PROPULSION SYSTEMS↗

OC6 Phase Ib: Validation of the CFD predictions of difference-frequency wave excitation on a FOWT semisubmersible

During the previous OC5 11 project, state-of-the-art mid-fidelity engineering tools for floating wind systems were found to consistently underpredict the nonlinear, low-frequency responses of semisubmersible offshore wind platforms, leading to substantial errors in the structural loads because of low-frequency surge and pitch resonance. To examine this underprediction, a coordinated investigation with computational fluid dynamics (CFD) simulations and model-basin experiments was carried out. Both investigations involved a fixed and simplified OC5-DeepCwind semisubmersible in bichromatic waves. The wave excitations - especially the nonlinear, difference-frequency excitation - on the structure from the CFD simulations were compared to the experimental measurements for validation, with uncertainty analyses for both the experimental and the CFD results. Furthermore, the wave excitations on each column of the semisubmersible were measured separately in the experiment, allowing the validation of the CFD results to be done on a per-column basis. Overall, the CFD predictions of the difference-frequency excitations agree with the experimental measurements, suggesting the CFD solutions can be used as a reference for tuning and improving the engineering-level tools and can provide a means to better understand the underprediction at low frequencies.

16 TIDAL AND WAVE POWER↗

Demonstration of CFD to support the coupled analysis of a reactor pressure vessel subjected to pressurized thermal shock

The structural components that comprise nuclear reactors and their supporting structures are subjected to harsh operating environments that can challenge their integrity, especially after exposure for extended duration or under accident condition. As one of the most significant components of a reactor, the Reactor Pressure Vessel (RPV) is exposed to an aggressive environment during the operation time (e.g. more than 40 years). Aging degradation mechanisms (e.g. thermo-fatigue) could grow initial defects up to a critical size, increasing the susceptibility to failure in the RPV. The conventional methods are mostly based on simple crack and structure geometries. Very limited studies consider the real conditions of the RPV subjected to a thermal shock due to a Loss of Coolant Accident (LOCA). During a LOCA event, the most severe conditions take place when the emergency core cooling (ECC) water is injected inside the cold legs filled initially with hotter water and/or steam. The rapid cooling of the down-comer and the internal RPV surface followed probably by re-pressurization of the RPV causes large temperature gradients and variation of pressure which induces thermal-mechanical stresses. In order to develop the model for integrity assessment of a reactor pressure vessel (RPV) subjected to pressurized thermal shock (PTS), a multi-physics simulation, which includes the thermo-hydraulic, thermo-mechanical and fracture mechanics analyses is necessary. The prediction of the temperature field is achieved by using computational fluid dynamics (CFD) simulation. In this report, a demonstration CFD standalone simulation is performed to support coupled analysis for Reactor Pressure Vessel (RPV) subjected to Pressurized Thermal Shock (PTS). The study use a simplified computational domain to represents a real RPV. The purpose of the study is to demonstrate the transient temperature response of RPV to ECC injection. The CFD model is built in a robust and efficient way for further coupled calculation. The next steps of this work, including the coupled thermal and tensor mechanics capabilities using Cardinal are expected to be complete by the end of FY21 for the demo problem. After this, into FY22, the capability will be demonstrated for a realistic RPV.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An open source fast fluid dynamics model for data center thermal management

Although computational fluid dynamics (CFD) has been widely adopted to improve data center thermal management, the high computational demand limits its applications, such as multivariate optimal design and operation. Fast fluid dynamics (FFD), which has been applied for fast airflow simulation, shows great potential. However, few research applied FFD for optimal design and operation of data center thermal management. This research improves the FFD model for data centers and conducts a comprehensive evaluation and demonstration. First, the FFD model is improved by solving the advection and diffusion equations together using an upwind scheme instead of a semi-Lagrangian advection solver in the conventional FFD model. Second, new features for data centers are added, such as a pressure correction method to simulate plenum airflow and dynamic boundary conditions for IT racks. The new FFD model is first validated with two indoor environment cases and the results show that the new FFD model has slightly better overall prediction accuracy and faster speed compared to the conventional FFD model. It is also observed that both FFD models achieve acceptable accuracy, except for a few localized disparities with experimental data, which might be due to simplified handling of turbulence viscosity near the boundaries. Furthermore, validation with a real data center shows that the FFD model achieves a similar level of accuracy as CFD when compared to the experimental measurements with some level of uncertainties. It is then demonstrated for data center optimal design and operation, which saves 53.4–58.8% of annual energy while still meeting the thermal requirements. In conclusion, with a much faster speed and comparable accuracy compared to CFD, the FFD model parallelized on a graphics processing unit is promising for practical model-based data center early design and operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing Numerical Models of the TALOS Wave Energy Converter

In this study, we present the development of a numerical model of the TALOS Wave Energy Converter (WEC) in WEC-Sim and compare it with existing numerical in-house models from Lancaster and results from DNV's Sesam code. The objective of this work is to validate the performance of the TALOS WEC using WEC-Sim and compare the results with those obtained from other numerical models. The TALOS WEC is a promising technology for the generation of clean, renewable energy from ocean waves. The development of a reliable numerical model for the TALOS WEC is crucial for its design and optimization. To achieve this, we have implemented the TALOS WEC in WEC-Sim and compared the results to in-house models from Lancaster and to results from DNV's Sesam code. Our results show good agreement with the results from Lancaster and DNV, demonstrating the accuracy and reliability of the numerical model developed in WEC-Sim. This work advances the field of wave energy conversion by providing a verified numerical model of the TALOS WEC, which can be used for further optimization and design studies.

CFD↗

Fast estimation of reaction rates in spherical and non-spherical porous catalysts

Here we present a methodology for modeling multi-step reaction rates in porous catalyst particles for use in CFD-DEM and two fluid models. Single-step effectiveness factors based on a Thiele modulus, while useful, cannot accurately capture the cascading reaction systems common in high temperature vapor-phase chemical reactors like fluidized catalytic cracking units and catalytic biomass fast pyrolysis systems. Instead, multi-step effectiveness vectors derived from steady-state solutions to the governing reaction-diffusion equations are needed. Solutions for various catalyst shapes are presented, including spheres, cylinders, and prisms. Computational challenges inherent in repeated evaluation of reaction rates with diffusion limitations are discussed, and an efficient implementation based on pre-computed lookup tables is proposed and demonstrated on a simulation of a fluidized bed reactor. Open-source code is provided for the compilation of reaction rate tables for use in ODE, DEM, and two-fluid models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling Flow and Particle Deposition in a Spent Nuclear Fuel Assembly

CFD (Computational Fluid Dynamic) simulation of aerosol-laden natural convective flow and particle deposition in a spent fuel storage canister with 37 assemblies is currently computationally prohibitive. PWR (Pressurized Water Reactor) assemblies have up to 289 pins or tubes with several spacer grids to align the pins. Spacer grids with mixing vanes induce swirling during operation to increase heat transfer. Each spacer grid contains hundreds of small structures such as retaining clips, channel walls, and openings. The largest canisters store 37 PWR assemblies thus, there are numerous pins, tubes, and spacer grids for which the flow region between and around these structures needs to be determined along with the movement and deposition of aerosol particles. Because of the complicated geometry, modeling the intricate flow even for just one assembly is currently impractical. Nonetheless, we are developing techniques for a practical model to assess the natural aerosol particle deposition process in a canister in the event that a release occurs from one or more fuel pins. In the previous work it was demonstrated that CFD can model the flow through a PWR spacer grid with mixing vanes, including particle deposition, in a reasonable amount of time on a personal computer. In this work, the analysis is extended to include the bypass region between an assembly and the canister basket walls. It is shown that the flow velocity in the bypass region is about three times that of the interstitial region between the pins. The lengths before and after the spacer grid are also extended to determine when the flow becomes fully developed. In addition, the approach of computationally “stitching together” segments of an assembly is demonstrated with the plan to ultimately model a full assembly. The fraction of particles that are deposited in a segment with a spacer grid is determined as a function of particle size and flow velocity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fuel Property Effects on Knock Propensity and Thermal Efficiency in a Direct-Injection Spark-Ignition Engine

Engine knock remains one of the major barriers to further improvement in thermal efficiency of Direct-Injection Spark-Ignition (DISI) engines. While Research Octane Number and Motor Octane Number are often used as standard rating methods for knock resistance of fuels, the impacts of other fuel properties on knock propensity in modern engines such as heat of vaporization (HoV) and laminar flame speed (LFS) require better understanding in order to co-optimize fuels and engine designs to achieve higher thermal efficiency and lower CO2 emission. In the present study, computational fluid dynamics (CFD) is used to model a boosted DISI engine with a focus on knock prediction and fuel property effects. A level-set G-equation model is employed to capture turbulent premixed combustion, and is coupled with a transported Livengood-Wu (L-W) integral approach to predict autoignition in the unburnt region. A criterion associated with the L-W integral is developed to accurately predict knock onset and knock-limited spark-advance. This model is then applied to a sensitivity analysis of HoV and LFS on knock tendency and thermal efficiency. The pressure-temperature trajectory framework is applied and extended to study the fuel effects on auto-ignition process in the engine. An existing efficiency-based merit function, which is derived from experiments for boosted SI engines, is evaluated and improved based on the current CFD results.

DISI↗

Liquid lithium divertor analysis using coupled plasma material interaction model

A liquid lithium divertor can improve performance of future fusion devices by creating efficient power exhaust and improving the energy confinement via pumping of the hydrogen isotopes. In addition, significantly higher heat fluxes can be handled if controlled vapor shielding is used to redistribute the divertor heat flux over a wider area. Design and optimization of such a system calls for an analysis model which includes a strong two-way coupling between the plasma and divertor material. The incoming plasma heat and particle flux will affect the divertor surface temperature, which is a defining factor of the lithium evaporative and sputtered flux going into the plasma. Results of the coupled model based on the plasma edge code SOLPS-ITER and the computational fluid dynamics (CFD) code ANSYS-CFX will be presented for different configurations. An analytical slab flow model is used as a heat transfer boundary condition for SOLPS, defining particle flux from the wall via calculation of the surface temperature. At the final step, results of the SOLPS analysis are verified using a 3D CFD magnetohydrodynamics (MHD) analysis which uses heat and particle flux from SOLPS as a boundary condition. In addition to plasma heat flux, both analytical and CFD temperature models include several plasma material interaction effects, such as lithium evaporation, condensation and sputtering based on deuterium target flux. New adatom sputtering model based on the available experimental data is presented. Analytical model is expanded to include free surface axisymmetric configurations. Results of parametric studies of the divertor configurations with different lithium inlet temperature and velocity will be presented leading to the optimal design resulting in the lowest possible lithium contamination in the core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EVALUATION OF PRESSURE DROP CORRELATIONS FOR THE WIRE-WRAPPED ROD BUNDLES

The accurate prediction of pressure drop in the fuel rod bundle is of importance for the design and thermal-hydraulic analysis of nuclear reactor system. Due to very complex geometry of wire-wrapped fuel rod bundle geometry for the Sodium Fast Reactor (SFR), a simple method using hydraulic (equivalent) diameter is not sufficient to predict the pressure drop of rod bundle accurately. For several decades, many experimental works have been performed to develop an accurate correlation for wire-wrapped fuel bundle friction factor. In these works, the friction factor correlation of wire-wrapped fuel bundle has been developed as a function of Reynolds number of the flow and the design parameters such as fuel pin diameter, wire diameter, rod pitch, and wire lead length. The Cheng and Todreas correlations are well-known and used in many subchannel analysis code, such as CADET, TRIO-U, MATRA-LMW, SE2-ANL, etc. Novendstern model, Rehme model, Baxi and Dalle Donne model are also well-known and widely referred. Computational Fluid Dynamics is another typical approach to predict the pressure drop of wire-wrapped fuel rod bundle, but it requires the model validation because the accuracy of pressure drop prediction by the CFD simulation depends on what turbulence model is employed. The present work aims at evaluating the existing pressure drop correlations for the wire-wrapped fuel rod bundle and evaluating the pressure drop of 217-pin rod bundle by the CFD analysis.

99 GENERAL AND MISCELLANEOUS↗

Design Optimization of A-Type Heat Exchangers based on High Performance, Non-Round Tubes

Air-to-refrigerant heat exchangers (HXs) have been the topic of considerable research as they are the fundamental heat transfer components of HVAC&R systems. For residential and commercial applications, indoor heat exchangers are often in A-type configurations to reduce air-conditioner system footprint while still delivering the required cooling or heating. Classical HX design practices typically assume a uniform frontal air velocity profile to facilitate the use of conventional tube-fin airside heat transfer and pressure drop correlations for performance prediction. However, it is well-reported throughout the literature that A-type HXs experience significant airflow maldistribution which can severely degrade HX performance. Additionally, recent advancements in simulation software such as Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and optimization algorithms have led researchers to consider primary heat transfer surface optimization to achieve highly compact HXs which do not require fins. In this paper, an A-type HX which utilizes shape-optimized non-round tubes is optimized for minimum duct size and airside pressure drop. This is achieved through coupling of an experimentally validated finite volume HX model with automated 2D CFD simulations of airflow through the HX for airside thermal-hydraulic performance evaluation. Preliminary results show that the optimal designs deliver similar capacity while achieving 20% reductions in airside pressure drop and duct cross-section area. Additionally, the optimal design apex angles in this study were similar to those from previous A-Type HX optimization studies for conventional tube-fin HX geometries, suggesting that the apex angle for optimal A-Type configuration performance may be independent of tube geometry.

42 ENGINEERING↗

Accelerating computational fluid dynamics simulation of post-combustion carbon capture modeling with MeshGraphNets

Packed columns are commonly used in post-combustion processes to capture CO 2 emissions by providing enhanced contact area between a CO 2 -laden gas and CO 2 -absorbing solvent. To study and optimize solvent-based post-combustion carbon capture systems (CCSs), computational fluid dynamics (CFD) can be used to model the liquid–gas countercurrent flow hydrodynamics in these columns and derive key determinants of CO 2 -capture efficiency. However, the large design space of these systems hinders the application of CFD for design optimization due to its high computational cost. In contrast, data-driven modeling approaches can produce fast surrogates to study large-scale physics problems. We build our surrogates using MeshGraphNets (MGN), a graph neural network framework that efficiently learns and produces mesh-based simulations. We apply MGN to a random packed column modeled with over 160K graph nodes and a design space consisting of three key input parameters: solvent surface tension, inlet velocity, and contact angle. Our models can adapt to a wide range of these parameters and accurately predict the complex interactions within the system at rates over 1700 times faster than CFD, affirming its practicality in downstream design optimization tasks. This underscores the robustness and versatility of MGN in modeling complex fluid dynamics for large-scale CCS analyses.

97 MATHEMATICS AND COMPUTING↗

Optimization of Membrane-based Carbon Capture using Dimensional Analysis, CFD and Process System Engineering

Carbon capture is a promising option to mitigate CO2 emissions from existing coal-fired power plants, cement and steel industries, and petrochemical complexes. Among the available technologies, membrane-based carbon capture presents the lowest energy consumption, operating costs, and carbon footprint. In addition, membrane processes have important operational flexibil-ity and response times. On the other hand, the major challenges to widespread application of this technology are related to reducing capital costs and improving membrane stability and durability.To upscale the technology into stacked flat sheet configurations, high fidelity computational fluid dynamics (CFD) that describes the separation process accurately are required. High fidelity simulations have been shown to be effective in studying the complex transport phenomena in membrane systems. In addition, obtaining high CO2 recovery percentages and product purity requires a multi-stage membrane process, where the optimal network configuration of the membrane modules must be studied in a systematic way. In order to address the design problem at process scale, we formulate a superstructure for the membrane-based carbon capture, including up to three separation stages. In the formulation of the optimization problem, we include reduced models, based on rigorous CFD simulations of the membrane modules. Numerical results indicate that the optimal design includes three membrane stages, and the capture cost is 45.4 $/t-CO2.

Pedrozo, Hector A.↗

Evaluating crown scorch predictions from a computational fluid dynamics wildland fire simulator

Abstract Background Crown scorch—the heating of live leaves, needles, and buds in the vegetative canopy to lethal temperatures without widespread combustion—is one of the most common fire effects shaping post-fire canopies. Despite the ability of computational fluid dynamic models to finely resolve fire activity and buoyant plume dynamics including heterogenous 3D distributions of forest canopy heating, these models have had only limited use in simulating fire effects and have not been used to evaluate crown scorch. Here, we demonstrate a method of evaluating crown scorch using a computational fluid dynamics model, FIRETEC, and validate this approach by simulating the experiments that were used to develop Van Wagner’s 1973 crown scorch model. Results The average scorch height prediction from FIRETEC compares well with the empirical model derived by Van Wagner, which is the most widely used empirical model for crown scorch. We further find that the 3D buoyant plume dynamics from a steady and homogeneous idealized heat source on the ground results in a spatially heterogenous crown scorch pattern reflecting complex heating dynamics that are best represented by percent scorch rather than height of scorch. Conclusions The ability of the computational fluid dynamics model to capture variation in crown scorch due to 3D buoyant plume dynamics provides direct links between forest structure, fire behavior, and fire effects that can be used by forest managers and researchers to better understand how fires result in crown damage under various environmental and management scenarios.

54 ENVIRONMENTAL SCIENCES↗

LES and RANS Spray Combustion Analysis of OME 3-5 and n-Dodecane

Clean-burning oxygenated and synthetic fuels derived from renewable power, so-called e-fuels, are a promising pathway to decarbonize compression–ignition engines. Polyoxymethylene dimethyl ethers (PODEs or OMEs) are one candidate of such fuels with good prospects. Their lack of carbon-to-carbon bonds and high concentration of chemically bound oxygen effectively negate the emergence of polycyclic aromatic hydrocarbons (PAHs) and even their precursors like acetylene (C 2 H 2 ), enabling soot-free combustion without the soot-NO x trade-off common for diesel engines. The differences in the spray combustion process for OMEs and diesel-like reference fuels like n-dodecane and their potential implications on engine applications include discrepancies in the observed ignition delay, the stabilized flame lift-off location, and significant deviations in high-temperature flame morphology. For CFD simulations, the accurate modeling and prediction of these differences between OMEs and n-dodecane proved challenging. This study investigates the spray combustion process of an OME 3 − 5 mixture and n-dodecane with advanced optical diagnostics, Reynolds-Averaged Navier–Stokes (RANS), and Large-Eddy Simulations (LESs) within a constant-volume vessel. Cool-flame and high-temperature combustion were measured simultaneously via high-speed (50 kHz) imaging with formaldehyde (CH 2 O) planar laser-induced fluorescence (PLIF) representing the former and line-of-sight OH* chemiluminescence the latter. Both RANS and LES simulations accurately describe the cool-flame development process with the formation of CH 2 O. However, CH 2 O consumption and the onset of high-temperature reactions, signaled by the rise of OH* levels, show significant deviations between RANS, LES, and experiments as well as between n-dodecane and OME. A focus is set on the quality of the simulated results compared to the experimentally observed spatial distribution of OH*, especially in OME fuel-rich regions. The influence of the turbulence modeling is investigated for the two distinct ambient temperatures of 900 K and 1200 K within the Engine Combustion Network Spray A setup. The capabilities and limitations of the RANS simulations are demonstrated with the initial cool-flame propagation and periodic oscillations of CH 2 O formation/consumption during the quasi-steady combustion period captured by the LES.

CFD↗