Observation of CW laser action in chlorine, argon, and helium gas mixtures
Continuous wave laser action in chlorine, Ar and He gas mixtures, observing energy transfer between Ar and chlorine by pumping action
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Continuous wave laser action in chlorine, Ar and He gas mixtures, observing energy transfer between Ar and chlorine by pumping action
Fringe pattern motion is compensated by closed-loop servo system that adjusts a mirror mounted on piezoelectric crystal, so that path difference in interferometer is maintained at constant values at one point in the field. System is applicable to holography with continuous wave laser sources.
System studies, equipment simulation, hardware development and flight tests which were conducted during the development of aircraft collision hazard warning system are discussed. The system uses a cooperative, continuous wave Doppler radar principle with pseudo-random frequency modulation. The report presents a description of the system operation and deals at length with the use of pseudo-random coding techniques. In addition, the use of mathematical modeling and computer simulation to determine the alarm statistics and system saturation characteristics in terminal area traffic of variable density is discussed.
Continuous-wave laser can achieve higher rate of emission through Q-switching. Technique keeps Q, energy storage rating, of laser cavity at low value while ion population inversion is being built up. Then Q is suddenly switched to high value just before instability occurs.
Electronic system locates interferences in radar reception. System utilizes well known frequency-modulated continuous-wave technique to locate objects with nonlinear impedances. FM transmitter generates signal through bandpass filter which eliminates higher order harmonics around carrier frequency.
A multichannel laser remote control system is described. The system is used in areas where radio frequency, acoustic, and hardware control systems are unsatisfactory or prohibited and where line of sight is unobstructed. A modulated continuous wave helium-neon laser is used as the transmitter and a 360 degree light collector serves as the antenna at the receiver.
A year's statistical data were acquired for the purposed of refining existing coordination procedures for the sharing of common frequency allocations between terrestrial and space services. The measurement program was conducted between October 3, 1970 and October 2, 1971, to empirically determine the cumulative distributions of scattering cross section per unit volume of hydrometeors at heights up to 9 km above the surface and of rain rate at the surface. The measurements were made in southeastern Virginia using a bistatic, continuous-wave, vertically polarized radar system operating at S- and X-band frequencies and tipping-bucket rain gages. The bistatic radar system was configured to represent an interference situation between a radio-relay system and a space communication system Earth terminal; the results may be interpreted as measured distributions of transmission loss for interference due to rain. A description of the experiment and equipment is included.
The irradiation effects of 22 MeV protons on the electrical characteristics of GaAs continuous-wave Gunn oscillators was studied. The radio frequency power output was reduced by 3 decibels at proton fluences in the neighborhood of 1.5 x 10 to the 12th power protons/sq cm. Conductance measurements indicate that the carrier removal rate at high electric fields remained roughly 40 percent less than at low fields. Diode efficiencies of two device groups were found to be monotonically descreasing functions of fluence. Frequency modulation noise was generally unaffected by radiation, but the magnitude of the noise in the noise power spectrum increased significantly. These effects are partially accounted for, in a qualitative fashion, by a model of electron traps having field-dependent net-carrier capture rates and various response times.
Experimental and analytical natural frequencies, nodal patterns, and typical modal displacements for a corrugated, flexibly supported, heat-shield panel are discussed. Good correlation was found between the experimental data and NASTRAN analytical results for the corrugated panel over a relatively wide frequency spectrum covered in the investigation. Of the two experimental techniques used for mode shape and displacement measurements (a noncontacting displacement sensor system and a holographic technique using a helium-neon, continuous-wave laser), the holographic technique was found, in the present investigation, to be faster and better suited for determining a large number of complex nodal patterns of the corrugated panel.
A standard particle sizer-cum-velocimeter is described, which was designed and built for the purpose of providing a standard source of aerosols of known size-distribution, moving with a known velocity, for the purpose of calibrating the continuous wave (CW) CO2-Laser Doppler Velocimeters at Marshall Space Flight Center. The instrument is designed with the capabilities of: (1) monitoring the size-distribution of particles of diameters larger than 1.0 microns; (2) measuring flow velocities in the range 0.05 - 100.0 cm/sec; (3) photographing particles of diameters above 0.2 microns moving at slow speeds (approximately 0.1 cm/sec); (4) measuring the size-distribution of particles settling in quiet air (or convection velocities of less than 0.15 cm/sec); and (5) use in the laboratory or in the field.
A continuous wave ultrasonic instrument capable of measuring very small changes in acoustic attenuation and phase velocity is described. This transmission oscillator ultrasonic spectrometer (TOUS) exhibits high sensitivity because it oscillates marginally. In spite of this high sensitivity, the TOUS system is relatively simple, compact, and inexpensive. These features suggest that the TOUS is suitable not only for precise laboratory measurements of the physical properties of materials, but also for field applications in nondestructive testing.
A unique experiment using advanced remote and direct sensing techniques was designed to investigate the detailed evolution and structure of clear-air convection. The measurements involved a high-power, narrow-beam pulse radar, a frequency modulated, continuous wave radar, an acoustic echo sounder, and instrumented aircraft. The various probing methods when used together complement each other and give a compatible and comprehensive description of the spatial and temporal evolution of clear-air convection.
Continuous-wave laser has been proposed based on reaction of hydrogen and fluorine. Hydrogen is produced by dissociation of hydrazine, which can be stored as liquid in light containers at room temperature.
The feasibility of employing a single laser Doppler velocimeter (LDV) system to remotely measure one-, two-, and three-dimensional velocity components in atmospheric flow fields is presented. A focused continuous wave CO2 laser emitting at the 10.6 mu wavelength is used as the laser source. Scan configurations employed by the LDV system were single-point, two-point, conical, and spiral conical. Test results are presented, which include favorable comparisons of velocity components measured by conventional anemometry and the LDV system. The feasibility using a single-beam LDV employing a conical scan technique for measuring two- and three-dimensional mean winds. Measurements to 300 m in dense fogs showed the ability of the LDV system to operate in dense fogs.
A high-power, continuous-wave laser was designed for use in power transmission and energy-collecting systems, and for producing incoherent light for pumping a laser material. The laser has a high repetitive pulsing rate per unit time, resulting in a high-power density beam. The laser is composed of xenon flash tubes powered by fast-charging capacitors flashed in succession by a high-speed motor connected to an automobile-type distributor.
Two alloy systems, (AlGa)As and (InGa)P, were studied for their properties relevant to obtaining laser diode operation in the visible region of the spectrum. (AlGa)As was prepared by liquid-phase epitaxy (LPE) and (InGa)P was prepared both by vapor-phase epitaxy and by liquid-phase epitaxy. Various schemes for LPE growth were applied to (InGa)P, one of which was found to be capable of producing device material. All the InGaP device work was done using vapor-phase epitaxy. The most successful devices were fabricated in (AlGa)As using heterojunction structures. At room temperature, the large optical cavity design yielded devices lasing in the red (7000 A). Because of the relatively high threshold due to the basic band structure limitation in this alloy, practical laser diode operation is presently limited to about 7300 A. At liquid-nitrogen temperature, practical continuous-wave operation was obtained at a wavelength of 6500 to 6600 A, with power emission in excess of 50 mW. The lowest pulsed lasing wavelength is 6280 A. At 223 K, lasing was obtained at 6770 A, but with high threshold currents. The work dealing with CW operation at room temperature was successful with practical operation having been achieved to about 7800 A.
Two CO2 laser doppler systems developed by NASA and some results obtained with them are discussed. A continuous wave, monostatic system for short-range wind measurement is described, and direct comparisons between the data obtained with it and with a cup-anemometer/wind vane system and a hot-wire anemometer show excellent agreement between the systems. Improvements being made in three CW, CO2 laser doppler systems, including a filter bank for optimized signal processing and a versatile scanning system, are noted. A pulsed CO2 system for measuring clear air turbulence is described, and results of test performance on board a Convair 990 are presented. It is noted that while the system was able to measure air speed and turbulence, the range of its transmitter-atmosphere-receiver was lower than predicted, and a difference of about 20 to 30 dB existed between the actual and theoretical turbulence measurements. Factors that may account for this loss are listed.
The present work reviews the fluid-mechanical aspects of high-power continuous-wave (CW) lasers. The flow characteristics of these devices appear as classical fluid-mechanical phenomena recast in a complicated interactive environment. The fundamentals of high-power lasers are reviewed, followed by a discussion of the N2-CO2 gas dynamic laser. Next, the HF/DF supersonic diffusion laser is described, and finally the CO electrical-discharge laser is discussed.