Search NASA⌕ Search

SEARCH · Search NASA

Results for “Clean”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Evaluation of AK-225(R), Vertrel(R) MCA and HFE A 7100 as Alternative Solvents for Precision Cleaning and Verification Technology

The National Aeronautics and Space Administration (NASA), Kennedy Space Center (KSC) Materials Science Division conducted a study to evaluate alternative solvents for CFC-113 in precision cleaning and verification on typical samples that are used in the KSC environment. The effects of AK-225(R), Vertrel(R), MCA, and HFE A 7100 on selected metal and polymer materials were studied over 1, 7 and 30 day test times. This report addresses a study on the compatibility aspects of replacement solvents for materials in aerospace applications.

Orlando Melendez↗

Absorbent pads for Containment, Neutralization, and Clean-Up of Environmental Spills Containing Chemically-Reactive Agents

A pad for cleaning up liquid spills is described which contains a porous surface covering, and an absorbent interior containing chemically reactive reagents for neutralizing noxious chemicals within the spilled liquid. The porous surface and the absorbent component would normally consist of chemically resistant materials allowing tentative spill to pass. The absorbent interior which contains the neutralizing reagents can but is not required to be chemically resilient and conducts the liquid chemical spill towards the absorbent interior containing the chemically reactive reagents where the dangerous and undesirable chemicals within the chemical spill are then neutralized as well as removed from the premises.

Davis, Dennis D.↗

Reactivities of Precision Cleaning Solvents with Hypergolic Propellants

The reactivities of several selected halogenated precision cleaning solvents with hypergolic propellants has been determined by analysis of the rates of formation of halide ion decomposition products. The solvents were Asahiklin AK 225, Asahiklin AK 225 AES, HFE 7100, HFE 7100 DE, Vertrel XF, Vertrel MCA, Vertrel MCA Plus, 1,1,2-trichloro-1,2,2-trifluoroethane (CFC-113), and trans-1,2-dichloroethylene (DCE). The propellants were hydrazine (HZ), monomethylhydrazine (MMH), and mixed oxides of nitrogen (MON-3). The Vertrel solvents showed significant reactivity with HZ. All of the solvents except DCE exhibited significant reactivity with MMH, particularly HFE 7100 DE and CFC-113. HFE 7100 DE, Vertrel MCA, and Vertrel MCA Plus also showed significant reactivity with MON-3 oxidizer.

Davis, Dennis D.↗

Development of Electrostatically Clean Solar Array Panels

Certain missions require Electrostatically Clean Solar Array (ECSA) panels to establish a favorable environment for the operation of sensitive scientific instruments. The objective of this program was to demonstrate the feasibility of an ECSA panel that minimizes panel surface potential below 100mV in LEO and GEO charged particle environments, prevents exposure of solar cell voltage and panel insulating surfaces to the ambient environment, and provides an equipotential, grounded structure surrounding the entire panel. An ECSA panel design was developed that uses a Front Side Aperture-Shield (FSA) that covers all inter-cell areas with a single graphite composite laminate, composite edge clips for connecting the FSA to the panel substrate, and built-in tabs that interconnect the FSA to conductive coated coverglasses using a conductive adhesive. Analysis indicated the ability of the design to meet the ECSA requirements. Qualification coupons and a 0.5m x 0.5m prototype panel were fabricated and tested for photovoltaic performance and electrical grounding before and after exposure to acoustic and thermal cycling environments. The results show the feasibility of achieving electrostatic cleanliness with a small penalty in mass, photovoltaic performance and cost, with a design is structurally robust and compatible with a wide range of current solar panel technologies.

Stern, Theodore G.↗

Development of an Electrostatically Clean Solar Array Panel

The results of design, analysis, and qualification of an Electrostatically Clean Solar Array (ECSA) panel are described. The objective of the ECSA design is to provide an electrostatic environment that does not interfere with sensitive instruments on scientific spacecraft. The ECSA design uses large, ITO-coated coverglasses that cover multiple solar cells, an aperture grid that covers the intercell areas, stress-relieved interconnects for connecting the aperture grid to the coverglasses, and edge clips to provides an electromagnetically shielded enclosure for the solar array active circuitry. Qualification coupons were fabricated and tested for photovoltaic response, conductivity, and survivability to launch acoustic and thermal cycling environments simulating LEO and GEO missions. The benefits of reducing solar panel interaction with the space environment are also discussed.

Stern, Theodore G.↗

Physical Evaluation of Cleaning Performance: We Are Only Fooling Ourselves

Surface cleaning processes are normally evaluated using visual physical properties such as discolorations, streaking, staining and water-break-free conditions. There is an assumption that these physical methods will evaluate all surfaces all the time for all subsequent operations. We have found that these physical methods are lacking in sensitivity and selectivity with regard to surface residues and subsequent process performance. We will report several conditions where evaluations using visual physical properties are lacking. We will identify possible alternative methods and future needs for surface evaluations.

Pratz, Earl↗

ODC-Free Solvent Implementation for Phenolics Cleaning

During phenolic liner manufacture, resin-impregnated (pre-preg) bias tape of silica, glass, or carbon cloth is tape-wrapped, cured, machined, and then wiped with 1,1,1 tri-chloroethane (TCA) to remove contaminants that may have been introduced during machining and handling. Following the TCA wipe, the machined surface is given a resin wet-coat and over-wrapped with more prepreg and cured. A TCA replacement solvent for these wiping operations must effectively remove both surface contaminants, and sub-surface oils and greases while not compromising the integrity of this interface. Selection of a TCA replacement solvent for phenolic over-wrap interface cleaning began with sub-scale compatibility tests with cured phenolics. Additional compatibility tests included assessment of solvent retention in machined phenolic surfaces. Results from these tests showed that, while the candidate solvent did not degrade the cured phenolics, it was retained in higher concentrations than TCA in phenolic surfaces. This effect was most pronounced with glass and silica cloth phenolics with steep ply angles relative to the wiped surfaces.

Wurth, Laura↗

Issues Related to Cleaning Complex Geometry Surfaces with ODC-Free Solvents

Implementing ozone depleting chemicals (ODC)-free solvents into full-scale reusable solid rocket motor cleaning operations has presented problems due to the low vapor pressures of the solvents. Because of slow evaporation, solvent retention is a problem on porous substrates or on surfaces with irregular geometry, such as threaded boltholes, leak check ports, and nozzle backfill joints. The new solvents are being evaluated to replace 1,1,1-trichloroethane, which readily evaporates from these surfaces. Selection of the solvents to be evaluated on full-scale hardware was made based on results of subscale tests performed with flat surface coupons, which did not manifest the problem. Test efforts have been undertaken to address concerns with the slow-evaporating solvents. These concerns include effects on materials due to long-term exposure to solvent, potential migration from bolthole threads to seal surfaces, and effects on bolt loading due to solvent retention in threads. Tests performed to date have verified that retained solvent does not affect materials or hardware performance. Process modifications have also been developed to assist drying, and these can be implemented if additional drying becomes necessary.

Bradford, Blake F.↗

Clean Room Apparel

American Hospital Supply Corporation (AHSC), Baxter Healthcare Corporation's predecessor, used the NASA informational base on contamination control technology to improve industrial contamination control technology. When a study determined that microscopic body particles escaping through tiny "windows" in woven garments worn by workers were the greatest source of contamination, AHSC developed TYVEK. This non-woven material filters 99% of all particulate matter larger than half a micron. Baxter Healthcare added a polyimide coating which seals and ties down any loose fibers, providing greater durability. Stress points along seams have been minimized to make the garment almost tearproof. Micro-Clean 212 garments are individually packaged and disposable.

Source record↗

NASA's Principal Center for Review of Clean Air Act Regulations

Marshall Space Flight Center (MSFC) was selected as the Principal Center for review of Clean Air Act (CAA) regulations. The CAA Principal Center is tasked to: 1) Provide centralized support to NASA/HDQ Code JE for the management and leadership of NASA's CAA regulation review process; 2) Identify potential impact from proposed CAA regulations to NASA program hardware and supporting facilities. The Shuttle Environmental Assurance Initiative, one of the responsibilities of the NASA CAA Working Group (WG), is described in part of this viewgraph presentation.

Clark-Ingram, Marceia↗

Electrolysis Propulsion Provides High-Performance, Inexpensive, Clean Spacecraft Propulsion

An electrolysis propulsion system consumes electrical energy to decompose water into hydrogen and oxygen. These gases are stored in separate tanks and used when needed in gaseous bipropellant thrusters for spacecraft propulsion. The propellant and combustion products are clean and nontoxic. As a result, costs associated with testing, handling, and launching can be an order of magnitude lower than for conventional propulsion systems, making electrolysis a cost-effective alternative to state-of-the-art systems. The electrical conversion efficiency is high (>85 percent), and maximum thrust-to-power ratios of 0.2 newtons per kilowatt (N/kW), a 370-sec specific impulse, can be obtained. A further advantage of the water rocket is its dual-mode potential. For relatively high thrust applications, the system can be used as a bipropellant engine. For low thrust levels and/or small impulse bit requirements, cold gas oxygen can be used alone. An added innovation is that the same hardware, with modest modifications, can be converted into an energy-storage and power-generation fuel cell, reducing the spacecraft power and propulsion system weight by an order of magnitude.

deGroot, Wim A.↗

Monitoring and Testing the Parts Cleaning Stations, Abrasive Blasting Cabinets, and Paint Booths

I have the opportunity to work in the Environmental Management Office (EMO) this summer. One of the EMO's tasks is to make sure the Environmental Management System is implemented to the entire Glenn Research Center (GRC). The Environmental Management System (EMS) is a policy or plan that is oriented toward minimizing an organization's impact to the environment. Our EMS includes the reduction of solid waste regeneration and the reduction of hazardous material use, waste, and pollution. With the Waste Management Team's (WMT) help, the EMS can be implemented throughout the NASA Glenn Research Center. The WMT is responsible for the disposal and managing of waste throughout the GRC. They are also responsible for the management of all chemical waste in the facility. My responsibility is to support the waste management team by performing an inventory on parts cleaning stations, abrasive cabinets, and paint booths through out the entire facility. These booths/stations are used throughout the center and they need to be monitored and tested for hazardous waste and material. My job is to visit each of these booths/stations, take samples of the waste, and analyze the samples.

Jordan, Tracee M.↗

Keeping the Air Clean and Safe: An Anthrax Smoke Detector

Scientists at work in the Planetary Protection division at NASA s Jet Propulsion Laboratory (JPL) sterilize everything before blasting it to the Red Planet. They take great pains to ensure that all spacecraft are void of bacterial life, especially the microscopic bacteria that can live hundreds of years in their spore states. No one is quite sure what Earthly germs would do on Mars, but scientists agree that it is safest to keep the Martian terrain as undisturbed as possible. Errant Earth germs would also render useless the instruments placed on exploration rovers to look for signs of life, as the life that they registered would be life that came with them from Earth. A team at JPL, headed by Dr. Adrian Ponce, developed a bacterial spore-detection system that uses a simple and robust chemical reaction that visually alerts Planetary Protection crews. It is a simple air filter that traps micron-sized bacterial spores and then submits them to the chemical reaction. When the solution is then viewed under an ultraviolet light, the mixture will glow green if it is contaminated by bacteria. Scientists can then return to the scrubbing and cleaning stages of the sterilization process to remove these harmful bacteria. The detection system is the space-bound equivalent of having your hands checked for cleanliness before being allowed to the table; and although intended to keep terrestrial germs from space, this technology has awesome applications here on Mother Earth. The bacterial spore-detection unit can recognize anthrax and other harmful, spore-forming bacteria and alert people of the impending danger. As evidenced in the anthrax mailings of fall 2001 in the United States, the first sign of anthrax exposure was when people experienced flu-like symptoms, which unfortunately, can take as much as a week to develop after contamination. Anthrax cost 5 people their lives and infected 19 others; and the threat of bioterrorism became a routine concern, with new threats popping up nearly everyday. The attacks threatened the safety that so many Americans took for granted, as the very air that people breathed became suspect. Any building with a circulation system, where large groups congregate, was now a potential target.

Source record↗

PRP: The Proven Solution for Cleaning Up Oil Spills

The basic technology behind PRP is thousands of microcapsules, tiny balls of beeswax with hollow centers. Water cannot penetrate the microcapsule s cell, but oil is absorbed right into the beeswax spheres as they float on the water s surface. This way, the contaminants, chemical compounds that originally come from crude oil such as fuels, motor oils, or petroleum hydrocarbons, are caught before they settle. PRP works well as a loose powder for cleaning up contaminants in lakes and other ecologically fragile areas. The powder can be spread over a contaminated body of water or soil, and it will absorb contaminants, contain them in isolation, and dispose of them safely. In water, it is important that PRP floats and keeps the oil on the surface, because, even if oil exposure is not immediately lethal, it can cause long-term harm if allowed to settle. Bottom-dwelling fish exposed to compounds released after oil spills may develop liver disease, in addition to reproductive and growth problems. This use of PRP is especially effective for environmental cleanup in sensitive areas like coral reefs and mangroves.

Source record↗

X-ray Device Makes Scrubbing Rugs Clean a Spotless Effort

If "pulling the rug out from under" means suddenly withdrawing support and assistance, then NASA is pretty good at "putting the rug under" when it comes to offering technical support and assistance to private industry. In the case of a new X-ray fluorescence (XRF) sensor featuring enhancements compliments of NASA, the Space Agency not only provided the rug, but helped give private industry a means to ensure it keeps clean. This sensor, utilized by NASA to read chemical bar codes concealed by paint and other coatings, perform on-the-spot chemical analyses in field conditions, and detect difficult-to-identify contaminants, has found another use as a tool that can measure how much soil is removed from household and commercial carpets. The original technology was developed in 2002 to conduct quality control for critical aluminum alloy parts destined for the space shuttle. Evaluation of these parts is critical for the Space Agency, as any signs of contamination, corrosion, or material deviation could compromise a shuttle mission.

Source record↗

Cleaning devices

Cleaning devices are described which include a vacuum cleaner wherein electrostatically charged brushes that brush dirt off a floor, are electrically grounded to remove charges that could tend to hold dirt to the brushes.

Schneider, Horst W.↗