Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computer Communication Networks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

430 records · Page 24

Design and Development of a High Fidelity Cyber-Physical Testbed

In order to ensure that future critical infrastructure systems are resilient to various types of such advanced and persistent threats, it is important to develop and integrate tailored solutions that holistically address cyber-attack detection and mitigation in a timely manner such that adverse system impacts that impact a large population are avoided. Further, it is essential to create environments that allow control, protection and communication to exist within a realistic environment to analyze the effects of adverse conditions and system operating modes. This project aims to establish a high-fidelity testbed environment for modeling and simulating a single microgrid all the way up to a network of microgrids along with baseline controls, protection, and associated cyber communication. This is an important activity because accurately modeling and simulating the various power-electronics-based DERs and loads in a microgrid is critical to adequately capturing their behaviors over a wide range of off-normal conditions, as well as to evaluate the resilience of the system using the developed controls. The work presented in this report focuses on the process of building this high-fidelity testbed and the associated experimentation it enables. The model enables the creation of high-fidelity use cases and associated datasets that have been used extensively within the initiative to study resilience and support novel control development and prototyping. The work heavily leverages existing capability that is part of the high-fidelity cyber-physical system experimentation lab to create a power hardware-in-the-loop setup. The report also details the creation of an automated model building platform that can enable high-fidelity real-time models to be built without much effort allowing existing low-fidelity models to be analyzed in higher fidelity. Lastly, the report also discusses efforts center around scaling to large complex power system models to make the experimentation more effective.

97 MATHEMATICS AND COMPUTING↗

Recommended reporting items for epidemic forecasting and prediction research: The EPIFORGE 2020 guidelines

Background: The importance of infectious disease epidemic forecasting and prediction research is underscored by decades of communicable disease outbreaks, including COVID-19. Unlike other fields of medical research, such as clinical trials and systematic reviews, no reporting guidelines exist for reporting epidemic forecasting and prediction research despite their utility. We therefore developed the EPIFORGE checklist, a guideline for standardized reporting of epidemic forecasting research. Methods and findings: We developed this checklist using a best-practice process for development of reporting guidelines, involving a Delphi process and broad consultation with an international panel of infectious disease modelers and model end users. The objectives of these guidelines are to improve the consistency, reproducibility, comparability, and quality of epidemic forecasting reporting. The guidelines are not designed to advise scientists on how to perform epidemic forecasting and prediction research, but rather to serve as a standard for reporting critical methodological details of such studies. Conclusions: These guidelines have been submitted to the EQUATOR network, in addition to hosting by other dedicated webpages to facilitate feedback and journal endorsement.

60 APPLIED LIFE SCIENCES↗

Model-Based Detection of Coordinated Attacks (DCA) in Distribution Systems

The fast-paced growth in digitization of smart grid components enhances system observability and remote-control capabilities through efficient communication. However, enhanced connectivity results in heightened system vulnerability towards cybersecurity risks in the cyber-physical power system. Coordinated cyber-attacks (CCA), when undetected, lead to system-wide impact in terms of large disturbances or widespread outages. Detecting CCA in the cyber layer is critical to thwart cyber-attacks in real-time before the attack impacts the physical system. The challenge of locating CCA stems from the complex grid dynamics, making it difficult to distinguish between normal operational variations and cyber-attack impact. CCA often employs multiple attack vectors targeting geographically distributed components, further complicating CCA identification. Existing research in intrusion detection is primarily focused on the transmission network and limited to detecting individual attacks. In this paper, a novel proactive DCA strategy is proposed for early detection of CCA by establishing correlations among distinct attack events through model-based reinforcement learning that utilizes abductive reasoning to conclude the attacker goal. The solution includes understanding the system model, learning the system dynamics, and correlating individual cyber-attacks to extract the attacker’s objective. The developed learning algorithm identifies the most probable attack path to reach the attacker’s objective by predicting the next attack steps. A DNP3-based cyber-physical co-simulation testbed is developed to test the proposed algorithm using the IEEE 13-node test feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Blockchain based Communication Architectures with Applications to Private Security Networks

Existing communication protocols in high consequence security networks are highly centralized. While this naively makes the controls easier to physically secure, external actors require fewer resources to disrupt the system because there are fewer points in the system can be destroyed or interrupted without the entire system failing. We present a solution to this problem using a proof-of-work-based blockchain implementation built on MultiChain. We construct a test-bed network containing two types of data input: visual imagers and microwave sensor information. These data types are ubiquitous in perimeter intrusion detection security systems and allow a realistic representation of a real-world network architecture. The cameras in this system use an object detection algorithm to nd important targets in the scene. The raw data from the camera and the outputs from the detection algorithm are then placed in a transaction on the distributed ledger. Similarly, microwave data is used to detect relevant events and are placed in a transaction. These transactions are then bundled into blocks and broadcast to the rest of the network using the Bitcoin-based MultiChain protocol. We develop five tests to examine the security metrics of our network. We performed the five security metric test using different sized networks from 7 to 39 nodes to determine how the metrics scale with respect to size. We nd that when compared to a centralized architecture our implementation provides a resiliency increase that is expected from a blockchain-based protocol without slowing the system so much that a human operator would notice. Furthermore, our approach is able to detect tampering in real time. Based on these results, we theorize that security networks in general could use a blockchain-based approach in a meaningful way.

97 MATHEMATICS AND COMPUTING↗

Cybersecurity Certification Recommendations for Interconnected Grid Edge Devices and Inverter Based Resources

Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RX-ADS: Interpretable Anomaly Detection Using Adversarial ML for Electric Vehicle CAN Data

Recent year has brought considerable advancements in Electric Vehicles (EVs) and associated infrastructures/ communications. Intrusion Detection Systems (IDS) are widely deployed for anomaly detection in such critical infrastructures. This paper presents an Interpretable Anomaly Detection System (RX-ADS) for intrusion detection in CAN protocol communication in EVs. Contributions include: 1) window based feature extraction method; 2) deep Autoencoder based anomaly detection method; and 3) adversarial machine learning based explanation generation methodology. The presented approach was tested on two benchmark CAN datasets: OTIDS and Car Hacking. The anomaly detection performance of RX-ADS was compared against the state-of-the-art approaches on these datasets: HIDS and GIDS. The RX-ADS approach presented performance comparable to the HIDS approach (OTIDS dataset) and has outperformed HIDS and GIDS approaches (Car Hacking dataset). Further, the proposed approach was able to generate explanations for detected abnormal behaviors arising from various intrusions. Furthermore, these explanations were later validated by information used by domain experts to detect anomalies. Other advantages of RX-ADS include: 1) the method can be trained on unlabeled data; 2) explanations help experts in understanding anomalies and root course analysis, and also help with AI model debugging and diagnostics, ultimately improving user trust in AI systems.

42 ENGINEERING↗

Cybersecurity for Electric Vehicle Charging Infrastructure

As the U.S. electrifies the transportation sector, cyberattacks targeting vehicle charging could impact several critical infrastructure sectors including power systems, manufacturing, medical services, and agriculture. This is a growing area of concern as charging stations increase power delivery capabilities and must communicate to authorize charging, sequence the charging process, and manage load (grid operators, vehicles, OEM vendors, charging network operators, etc.). The research challenges are numerous and complicated because there are many end users, stakeholders, and software and equipment vendors interests involved. Poorly implemented electric vehicle supply equipment (EVSE), electric vehicle (EV), or grid operator communication systems could be a significant risk to EV adoption because the political, social, and financial impact of cyberattacks — or public perception of such — would ripple across the industry and produce lasting effects. Unfortunately, there is currently no comprehensive EVSE cybersecurity approach and limited best practices have been adopted by the EV/EVSE industry. There is an incomplete industry understanding of the attack surface, interconnected assets, and unsecured inter faces. Comprehensive cybersecurity recommendations founded on sound research are necessary to secure EV charging infrastructure. This project provided the power, security, and automotive industry with a strong technical basis for securing this infrastructure by developing threat models, determining technology gaps, and identifying or developing effective countermeasures. Specifically, the team created a cybersecurity threat model and performed a technical risk assessment of EVSE assets across multiple manufacturers and vendors, so that automotive, charging, and utility stakeholders could better protect customers, vehicles, and power systems in the face of new cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LEED: A Lightwave Energy-Efficient Datacenter

The Lightwave Energy-Efficient Datacenter (LEED) program is a disruptive “green-field” approach that provides a quantum leap in the energy efficiency of datacenters. LEED’s fundamental value proposition is that a novel and re-architected optical network—RotorNet— can deliver “more bandwidth per buck” as well as unique system-level attributes that significantly improve overall datacenter energy efficiency and performance. LEED has developed three system-level testbeds. The first testbed uses calibrated hardware and software power measurements to determine server energy efficiency as a function of network bandwidth and workload. These measurements have shown that increasing network communications bandwidth dramatically increases server energy efficiency providing a realistic path to the overall ENLITENED program goal of doubling the number of transactions per joule. The second testbed demonstrates key hardware: a prototype low-loss, high-port count optical “selector switch”. This switch was fabricated, racked, and tested. Measured switch characteristics include loss, bandwidth, crosstalk, switch time, system-level switch time (including the transceivers), and bit error rate. The third testbed demonstrates a fully working and manufactured pinwheel design which dramatically lowers the cost of design, while delivering high switch radix and low reconfiguration times. The LEED project has tied these three novel photonic switch prototypes together with production servers and software through the development of a novel FPGA-based NIC platform called Corundum. Corundum ensures that the packet-switched protocols supported by commodity operating systems and devices can interface with the Rotor switch design. The LEED group has used this combined hardware and software prototype to characterize applications running at a commercially relevant scale. The project has used a combination of enhanced optical modulation amplitude (OMA) modulators, broadband multiplexers and demultiplexers, avalanche photodiodes, and a novel burst-mode receivers to enable the insertion of LEED-developed optical switches without the need for expensive optical amplification. Our modeling has shown that measured LEED-developed device characteristics can achieve link characteristics of 2 pJ/bit including both transceivers and the Rotor switch. In summary, the LEED program has demonstrated a credible and practical path, through novel hardware and software, to realize the program objectives of ENLITENED. The net result will ensure that the United States maintains its strength in the crucial sector of Information Technology, which is vital to both our economic security and our national security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Three-Dimensional Grid Visualization for Planning Activities: A Dubai Case Study

National Laboratory of the Rockies (NLR), in collaboration with the Dubai Electricity and Water Authority (DEWA) and Infra-X, has undertaken the Energy Visualization Analysis Project. The aim of this project is to enhance analytical and 3D visualization capabilities for distribution network planning and renewable energy integration. As modern grid continues to evolve with large-scale solar PV deployment and emerging distributed energy resources (DERs), the ability to effectively analyze, visualize, and communicate complex grid behaviors has become increasingly critical. The project focuses on developing empirical use cases based on real distribution feeder data and engineering workflows, ensuring the outcomes are directly aligned with operational environment. Through time-series power flow simulations and nodal hosting capacity analysis, the study quantifies the impacts of high PV penetration on voltage and thermal limits within representative 11 kV feeders. These analyses identify specific nodes and conditions where DER integration challenges arise. Furthermore, a Battery Energy Storage System (BESS) optimization algorithm was applied to determine the optimal size and placement of storage systems that can mitigate network constraints and enhance hosting capacity. The comparative results between base-case and BESS-augmented scenarios clearly demonstrate improvements in network stability and load management efficiency. In parallel, the NLR team developed an immersive 3D visualization framework, enabling interactive exploration of grid simulations using commodity head-mounted display (HMD) systems. This framework transforms conventional 2D simulation data into spatially intuitive visual environments - allowing engineers to analyze feeder conditions, PV hosting potential, and BESS effects in real time. This report represents the first foundational phase in establishing a visualization-driven analytical ecosystem. It provides a methodological foundation for data integration, visualization architecture, and simulation-based decision support, paving the way for large-scale adoption of immersive visualization across DEWA's Smart Grid Initiative, R&D activities, and future network resilience studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigation of birefringence in cavity-based quantum networks using frequency-encoded photons

Atom-cavity systems offer unique advantages for building large-scale distributed quantum computers by providing strong atom-photon coupling while allowing for high-fidelity local operations of atomic qubits. However, in prevalent schemes where the photonic state is encoded in polarization, cavity birefringence introduces an energy splitting of the cavity eigenmodes and alters the polarization states, thus limiting the fidelity of remote entanglement generation. To address this challenge, we propose a scheme that encodes the photonic qubit in the frequency degree-of-freedom. The scheme relies on resonant coupling of multiple transverse cavity modes to different atomic transitions that are well-separated in frequency. We numerically investigate the temporal properties of the photonic wavepacket, two-photon interference visibility, and atom-atom entanglement fidelity under various cavity polarization-mode splittings and find that our scheme is less affected by cavity birefringence. Finally, we propose practical implementations in two trapped ion systems, using the fine structure splitting in the metastable D state of 40 Ca + , and the hyperfine splitting in the ground state of 225 Ra + . Furthermore, our study presents an alternative approach for cavity-based quantum networks that is less sensitive to birefringent effects, and is applicable to a variety of atomic and solid-state emitter-cavity interfaces.

Cavity quantum electrodynamics↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precursor Analysis Report: Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016

The Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016 Precursor Analysis Report leverages publicly available information about the December 2016 cyber attack against the Ukrainian Ukrenergo electric transmission utility and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. Industroyer is a modular malware framework designed to deploy several Industrial Control System (ICS) protocol-specific attack payloads to disrupt electricity distribution. Adversaries deployed Industroyer within the target network on a Microsoft Windows endpoint capable of directly manipulating or communicating with ICS. Industroyer abuses the functionality of a targeted ICS’s legitimate control system to achieve its intended impact. Adversaries likely first gained access to Ukrenergo enterprise networks in early 2016 after a successful spearphishing campaign against organizations in the electric power sector. Adversaries then began capturing credentials beginning on 1 December 2016. This allowed access to the ICS environment at the Pivnichna electric transmission substation outside Kyiv through a device dual-homed on the Information Technology (IT) and ICS networks. Adversaries conducted discovery, targeting, and access to this device using information and previously captured credentials from compromised enterprise IT machines. Finally, the adversaries deployed and launched the Industroyer malware just before midnight on 17 December. By midnight, Ukrenergo had lost control of a targeted substation, resulting in electric power outages for over an hour in the city of Kyiv and the Kyiv region. Researchers and analysts identified 31 unique techniques (used in a sequence of 33 steps) utilized during the attack with a total of 846 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Twenty-nine of the identified techniques used during the Industroyer cyber attack were precursors to the triggering event. Analysis identified 548 observables associated with these precursor techniques, 353 of which were assessed to have an increased likelihood of being perceived in the 300 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Next Stage for Smart Cities: Metrics to Spur an Evolution from Technology for Efficiency to Technology for People's Needs

The Smart Cities movement is about a decade old, energized by the USDOT Smart Cities grant that sparked cities to dream big. Now, 10 years later, and multitudes of conferences and papers later, the biggest question regarding Smart Cities is whether any progress has been made? Smart Cities forums are typically led by the technology sector, either telecommunications, internet access, or most recently artificial intelligence (AI) concerns. Each of these areas have grown and found new applications in the context of Smart Cities, however, these technology applications are just tools toward ends. Do digital communications and assistance enable or foster improved access to real, tactile, non-virtual goods and services such as transportation, food, housing, trash removal, health care, education, social interaction? These and other topics are not 'big tech', but are each critical to quality of life outcomes and are day-to-day necessities, comprising many of the touch points through which citizens interact with municipal agencies. Regarding Smart Cities, relationships have not been fully refined as to how best to merge the emerging generation of technology and related trends with more mundane but essential requirements of tactile services. How should municipal managers and operators bring the range of new technology tools (e.g. on-demand transit, automated vehicles, digital connectivity) to bear to improve functions serving real- physical- non-virtual needs? How do we make cities more efficient in providing access to services and opportunities for improved quality of life? This paper examines the current Smart City movement, emerging trends, and the need to put metrics with respect to the delivery, access, and provision of real-life needs. Using a few case studies of past, present, and projected future scenarios, this paper attempts to bring Smart Cities into the real cities domain, perhaps pushing the moniker away from 'Smart' to 'Efficient' - something that can be measured, counted, and assessed. Through the consideration of the next stage of the evolution of cities from 'Smart' to 'Efficient', the combined efforts and experience of multiple researchers at the NREL and their network of collaborators highlights the need for updates metrics that can be used to start guiding efforts toward productive initiatives to improve quality of life.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Support for Reactor Operators in Case of Cyber-Security Threats (NEUP Final Report)

Increasing use of digital technology in nuclear power plants (NPPs) poses cyber-security as a crucial threat to public safety and to continuous energy production. Cyber-security risks are comprised of complex known and unknown interactions between various entities, system vulnerabilities, network protocols, human users and malicious attacks. There is little understanding or research geared towards plant operators’ response under cyber-security threats and operational procedures to cope with such threats. This is particularly critical when a cyber-security event masquerades as a safety incident or an evolving accident. Instead of leading operators to the remediation of the accident, the masked cyber event may lead them to circumvent the safety mechanisms of the plant. Given these challenges, the objective of this project is to develop a tool to characterize abnormal NPP events as “cyber” or “safety” incidents, and to further develop this tool as a real-time operator aid to assist in response to the incident. This NEUP Final Report summarizes the research efforts towards the above goals and the results in the following three aspects. First, a methodology for classifying abnormal NPP events as cyber-attacks or safety incidents was developed. This provides the basis for responding to potential cyber-attacks. In this methodology, the causal relationships between various variables (i.e., physical variables, network variables, and control variables) for a nuclear system under consideration are modeled using dynamic Bayesian networks. Based on observations of certain variables (i.e., the evidence), inference is performed to identify the state of hidden variables, which helps indicate the occurrence of cyber-attacks or safety incidents. The proposed methodology was applied to the full scope NPP simulator system at The Ohio State University as a case study. The result shows that the proposed methodology is capable of distinguishing between cyber-attacks and safety incidents. Second, a game-theoretic approach for responding to cyber-attacks on nuclear power plants was developed. This is the second major goal of the project, and the method is used to recommend optimal responses to reactor operators in the case of cyber-attacks. We consider two cases in this research. In the first case, the interaction between the defender (i.e., the reactor operator) and the attacker is modeled as a two-player, nonzero-sum, Markov game with an infinite time horizon. In the second case, we consider a semi-Markov game between the defender and the attacker within a finite time horizon. The model in the second case enables us to consider the time sensitive response of the defender. In each case, the method for deriving the Nash equilibrium is developed. The Nash Equilibrium of the game provides the valid prediction of both players’ actions because no single player can benefit from unilaterally deviating from the equilibrium policy if the other player adheres to his/hers, hence it provides the best response of the defender to cyber-attacks. The proposed method in each case is demonstrated through a simplified benchmark digital feedwater control system. Third, a prototype display is developed to integrate the above information. The prototype display depicts the communication information to the operator and incorporates the cyber-security tool developed by the team into the interface. It consists of the regular display in current control rooms, as well as a panel used to indicate the occurrence of cyber-attacks or safety events and a panel used to guide the operator’s response to detected cyber-attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Facility Cybersecurity Framework Best Practices

Federal facilities are increasingly adopting automation and connecting to the Internet creating an energy-internet-of-things environment that converges operational technology (OT) and information technology (IT). Today's buildings increasingly weave together networked sensors and cyber and physical systems that enable data to be collected, aggregated, exchanged, stored and monetized in new ways. Building technological advances have created new energy technology, services, markets and value creation opportunities (e.g. transactive energy, two-way grid communications, machine learning, and increased use of renewable and distributed energy resources). But as larger data sets are being exchanged at faster speeds between an increasing number of OT systems, it becomes more difficult to protect the security of the data lifecycle and the physical equipment it interacts with. These challenges are especially difficult to overcome because the economic and environmental gain (interoperability, big data, social networks and ubiquitous information sharing) are driving these prominent trends in the digital age. Often cybersecurity is an afterthought. The U.S. Department of Energy’s (DOE) Federal Energy Management Program (FEMP) funded the Pacific Northwest National Laboratory (PNNL) to develop various cybersecurity tools, trainings, and reports to aid federal facility managers – and other building owners and operators – in better applying frameworks and lessons learned from the National Institute of Standards and Technology (NIST) Cybersecurity Framework (CSF), risk management framework (RMF), DOE’s cybersecurity capability maturity model (C2M2), and a wide variety of industry best practices and guidance documents (i.e., NIST 800 series, Department of Defense United Facilities Criteria). This set of tools, collectively known as the FEMP Facility-Related Control System Cyber Toolkit (FRCS Cyber Toolkit)2, is focused on cybersecurity concerns from facility-related control systems and other operational technology (OT), such as industrial control systems (ICS). The FRCS Cyber Toolkit can be applied across six of the sixteen critical infrastructure sectors designated by the Department of Homeland Security, including government facilities, healthcare and public health, commercial facilities (e.g., public assembly, offices, lodging), financial services (e.g., banking and insurance), emergency services (e.g., fire and police stations), and information technology. With increasingly converged IT and OT systems, it is crucial to address OT cybersecurity considerations and assess how the seam of these two systems could impact the overall cybersecurity posture of a facility. The objective of this report is to provide an overview of the best possible method to use FRCS Cyber Toolkit (section 2.0) and distilled cybersecurity best practices for the federal facilities to address growing non-linear cyber threats (section 3.0). Recommendations in this document are aggregated from several NIST and other documents (see Appendix A for additional details).

97 MATHEMATICS AND COMPUTING↗