Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Room Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Diagnostic Cardiac Catheterization Using the MEDRAD Avanta™ Fluid Management System as Compared to the Traditional Manual Injection Method

Nearly 4 million patient procedures performed annually in US cardiac catheterization laboratories utilize contrast media to achieve vessel opacification. The amount of contrast media used is variable and depends on the complexity of the procedure, the method of contrast delivery as well as the skill-level of the operator. Since the total amount of contrast used for each procedure can have both patient safety and economic implications, it is essential for cardiologists to have the ability to control contrast delivery such that optimal angiographic image quality is achieved using the least amount of contrast. Although the complication rate associated with cardiac catheterization remains low, the most common serious complication, contrast-induced nephropathy (CIN), is associated with poor prognosis and a high mortality rate. Numerous interventional strategies for preventing and reducing the severity of CIN have demonstrated varying degrees of clinical benefit, but none has been shown to reliably prevent this serious complication. To date, the most effective approach for reducing the risk of CIN is to properly hydrate the patient and to minimize the amount of contrast media administered. Automated injection systems are intended for use in virtually all cardiac catheterization procedures and have numerous features which can provide potential advantages over traditional methods. With automated injection technology the operator is able to control and precisely monitor contrast delivery. Additionally, the MEDRAD Avanta Fluid Management Injection System utilizes a sterile contrast reservoir which eliminates the need to discard unused contrast in individual opened containers following each procedure. Considering that an average of 50% of opened contrast media is wasted using manual injection methods, this savings can provide a substantial economic benefit. Automated systems also facilitate the use of smaller (5 French) catheter sizes. Precise flow control and the use of smaller diameter catheters have both been shown to reduce the volume of contrast administered. The use of smaller size catheters also permits more rapid hemostasis, thus allowing shorter ambulation time without the need for costly wound closure devices. These factors can result in enhanced patient satisfaction as well as more efficient management of post-procedure rooms. The intent of this study was to demonstrate that using the MEDRAD Avanta™ Fluid Management Injection System (MEDRAD, INC., Pittsburgh, PA) for coronary diagnostic procedures can produce a reduction in the volume of contrast administered without loss of operational quality or efficiency. In addition, this study will explore procedure time and efficiency in an effort to minimize the amount of ionizing radiation delivered to the patient as well as the diagnostic team members. Study Design This is a post-market study designed to collect data during diagnostic cardiac catheterization when utilizing 5FR or 6FR catheters in conjunction with the Avanta Fluid Management System or a manual manifold injection method control group. A minimum of 420 patients scheduled for diagnostic cardiac catheterization will be enrolled in the study cohort. Patients will be assigned into the following two groups. Group 1: Catheterization with 5FR or 6FR catheters, using the traditional manual manifold injection method for contrast media delivery which is defined as manual hand injection of contrast media through a 3 or 4 port manifold and left ventriculography performed via standard fixed rate power injection. Group 2: Catheterization with 5FR or 6FR catheters, using the MEDRAD Avanta™ system for contrast media delivery. Study endpoints include volume of contrast media administered during diagnostic cardiac catheterization, volume of contrast media wasted post-procedure, procedure time (defined as the time from first catheter insertion to last diagnostic catheter removal), fluoroscopy time and angiographic image quality. The study demonstrated that use of the Advanta system reduced overall contrast utilization by decreasing the amount of contrast administered to the patient and reducing the amount of contrast wasted during preparation and post-procedure clean-up. The quality of the angiographic images and the radiation exposure to the patient were not affected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and fabrication of non silicon substrate based MEMS energy harvester for arbitrary surface applications

Internet of Things (IoT) uses MEMS sensor nodes and actuators to sense and control objects through Internet. IOT deploys millions of chemical battery driven sensors at different locations which are not reliable many times because of frequent requirement of charging & battery replacement in case of underground laying, placement at harsh environmental conditions, huge count and difference between demand (24 % per year) and availability (energy density growing rate 8% per year). Energy harvester fabricated on silicon wafers have been widely used in manufacturing MEMS structures. These devices require complex fabrication processes, costly chemicals & clean room. In addition to this silicon wafer based devices are not suitable for curved surfaces like pipes, human bodies, organisms, or other arbitrary surface like clothes, structure surfaces which does not have flat and smooth surface always. Therefore, devices based on rigid silicon wafers are not suitable for these applications. Flexible structures are the key solution for this problems. Energy transduction mechanism generates power from free surrounding vibrations or impact. Sensor nodes application has been purposefully selected due to discrete power requirement at low duty cycle. Such nodes require an average power budget in the range of about 0.1 microwatt to 1 mW over a period of 3-5 seconds. Energy harvester is the best alternate source in contrast with battery for sensor node application. Novel design of Energy Harvester based on cheapest flexible non silicon substrate i.e. cellulose acetate substrate have been modeled, simulated and analyzed on COMSOL multiphysics and fabricated using sol-gel spin coating setup. Single cantilever based harvester generates 60-75 mV peak electric potential at 22Hz frequency and approximately 22 µW power at 1K-Ohm load. Cantilever array can be employed for generating higher voltage by replicating this structure. This work covers design, optimization, fabrication of harvester and schottky diodes based voltage multiplier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cleanup and Dismantling of Highly Contaminated Ventilation Systems Using Robotic Tools - 13162

The UP1 plant reprocessed nearly 20,000 tons of used natural uranium gas cooled reactor fuel coming from the first generation of civil nuclear reactors in France. Following operating incidents in the eighties, the ventilation system of the continuous dissolution line facility was shut down and replaced. Two types of remote controlled tool carriers were developed to perform the decontamination and dismantling operations of the highly contaminated ventilation duct network. The first one, a dedicated small robot, was designed from scratch to retrieve a thick powder deposit within a duct. The robot, managed and confined by two dedicated glove boxes, was equipped for intervention inside the ventilation duct and used for carrying various cleanup and inspection tools. The second type, consisting of robotic tools developed on the base of an industrial platform, was used for the clean-up and dismantling of the ventilation duct system. Depending on the type of work to be performed, on the shape constraints of the rooms and any equipment to be dismantled, different kinds of robotic tools were developed and installed on a Brokk 40 carrier. After more than ten years of ventilation duct D and D operations at the UP1 plant, a lot of experience was acquired about remote operations. The three main important lessons learned in terms of remote controlled operation are: characterizing the initial conditions as much as reasonably possible, performing non-radioactive full scale testing and making it as simple and modular as possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An inverse approach to solving zone air infiltration rate and people count using indoor environmental sensor data

Physics-based simulation of energy use in buildings is typically widely used in building design and performance rating, controls design and operations. However, various challenges exist in the modeling process. Model parameters such as people count and air infiltration rate are usually highly uncertain, yet they have significant impacts on the simulation accuracy. With the increasing availability and affordability of sensors and meters in buildings, a large amount of measured data has been collected including indoor environmental parameters, such as room air dry-bulb temperature, humidity ratio, and CO 2 concentration levels. Fusing these sensor data with traditional energy modeling poses new opportunities to improve simulation accuracy. This study develops a set of physics-based inverse algorithms which can solve the highly uncertain and hard-to-measure building parameters such as zone-level people count and air infiltration rate. A simulation-based case study is conducted to verify the inverse algorithms implemented in EnergyPlus covering various sensor measurement scenarios and different modeling use cases. The developed inverse models can solve the zone people count and air infiltration at sub-hourly resolution using the measured zone air temperature, humidity and/or CO 2 concentration given other easy-to-measure model parameters are known.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defining the Direction of Nuclear-Plasma Interaction Research at the National Ignition Facility

Electron-mediated nuclear-plasma interactions (NPIs) have the potential to change nuclear reaction rates in high energy density plasma (HEDP) environments, such as those found in experiments at the National Ignition Facility (NIF), in astrophysical phenomenon, or in nuclear detonations, relative to conventional laboratory measurements on room-temperature targets. Two Discovery Science shots to detect these interactions at the NIF were conducted in January and September 2017 at the conclusion of a campaign to develop the indirect-drive exploding pusher experimental platform and diagnostics. These shots were designed to measure the differential population of a high-spin isomer of 133 Xe of an inplasma versus a control sample, where a non-zero differential would indicate a measurable influence of the plasma on 134 Xe(n,2n) reactions. Preliminary observations from these shots were consistent with a small NPI effect, but improved theoretical understanding coupled with refined data analysis were needed to definitively establish the discovery or lack thereof. Achieving both of these, a statistically-credible NPI was indeed observed at a level predicted by an adapted Monte Carlo gamma-cascade model, a significant lowering by of the isomerto- ground state activity ratio in 133 Xe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Review of antiskid and brake dynamics research

The behavior of various antiskid systems was investigated under controlled conditions. Results from utilizing a single main wheel of a DC-9 aircraft suggest that the systems investigated perform well under most circumstances but there may be room for improvement. For example, it was demonstrated that pressure bias modulation can adversely affect the response of antiskid systems to rapid changes in the runway friction level. Results also indicate that antiskid systems designed to operate at a slip ratio of approximately 0.1 can provide a maximum braking effort without undue loss in the cornering capability of the tire. Time histories of braking friction coefficient were shown to provide a means of determining antiskid system performance and for systems that employed pressure bias modulation it was shown that performance could also be estimated from time histories of brake pressure and torque.

Stubbs, S. M.↗

MO-D-213-07: RadShield: Semi- Automated Calculation of Air Kerma Rate and Barrier Thickness

Purpose: To develop the first Java-based semi-automated calculation program intended to aid professional radiation shielding design. Air-kerma rate and barrier thickness calculations are performed by implementing NCRP Report 147 formalism into a Graphical User Interface (GUI). The ultimate aim of this newly created software package is to reduce errors and improve radiographic and fluoroscopic room designs over manual approaches. Methods: Floor plans are first imported as images into the RadShield software program. These plans serve as templates for drawing barriers, occupied regions and x-ray tube locations. We have implemented sub-GUIs that allow the specification in regions and equipment for occupancy factors, design goals, number of patients, primary beam directions, source-to-patient distances and workload distributions. Once the user enters the above parameters, the program automatically calculates air-kerma rate at sampled points beyond all barriers. For each sample point, a corresponding minimum barrier thickness is calculated to meet the design goal. RadShield allows control over preshielding, sample point location and material types. Results: A functional GUI package was developed and tested. Examination of sample walls and source distributions yields a maximum percent difference of less than 0.1% between hand-calculated air-kerma rates and RadShield. Conclusion: The initial results demonstrated that RadShield calculates air-kerma rates and required barrier thicknesses with reliable accuracy and can be used to make radiation shielding design more efficient and accurate. This newly developed approach differs from conventional calculation methods in that it finds air-kerma rates and thickness requirements for many points outside the barriers, stores the information and selects the largest value needed to comply with NCRP Report 147 design goals. Floor plans, parameters, designs and reports can be saved and accessed later for modification and recalculation. We have confirmed that this software accurately calculates air-kerma rates and required barrier thicknesses for diagnostic radiography and fluoroscopic rooms.

07 ISOTOPE AND RADIATION SOURCES↗

Compact cold stage for micro-computerized tomography imaging of chilled or frozen samples

High resolution X-ray microCT (computerized tomography) can be used to image a variety of objects, including temperature-sensitive materials. In cases where the sample must be chilled or frozen to maintain sample integrity, either the microCT machine itself must be placed in a refrigerated chamber, or a relatively expensive commercial cold stage must be purchased. We describe here the design and construction of a low-cost custom cold stage suitable for use in a microCT imaging system. Our device uses a boron nitride sample holder, two-stage Peltier cooler, fan-cooled heat sink, and electronic controller to maintain sample temperatures as low as −25 °C ± 0.2 °C for the duration of a tomography acquisition. The design does not require modification to the microCT machine, and is easily installed and removed. Our custom cold stage represents a cost-effective solution for refrigerating CT samples for imaging, and is especially useful for shared equipment or machines unsuitable for cold room use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics of charged excitons in electronically and morphologically homogeneous single-walled carbon nanotubes

Significance Formation of quasiparticles, such as excitons, polarons, and trions in semiconductors are the foundation for modern optoelectronics. Unlike the widely investigated exciton and polaron, the trion, a three-body charge-exciton bound state, is less familiar due to its small binding energy in conventional inorganic semiconductors. Here, employing ultrafast spectroscopy and rigorously controlled charge-doping levels, we characterize trion creation and decay in single-walled carbon nanotubes (SWNTs), wherein trions are stable at room temperature. We show that SWNT trions derive exclusively from a precursor exciton state, and importantly, that exciton-to-trion conversion can approach unity under appropriate conditions. Because trions simultaneously carry excitation energy, charge, and spin, our findings may guide design of new SWNT-based optoelectronic devices, including photovoltaics, photodetectors, and spintronics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser angle sensor

A laser angle measurement system was designed and fabricated for NASA Langley Research Center. The instrument is a fringe counting interferometer that monitors the pitch attitude of a model in a wind tunnel. A laser source and detector are mounted above the model. Interference fringes are generated by a small passive element on the model. The fringe count is accumulated and displayed by a processor in the wind tunnel control room. This report includes optical and electrical schematics, system maintenance and operation procedures.

Pond, C. R.↗

Human Reliability Assessments: Using the Past (Shuttle) to Predict the Future (Orion)

NASA (National Aeronautics and Space Administration) Johnson Space Center (JSC) Safety and Mission Assurance (S&MA) uses two human reliability analysis (HRA) methodologies. The first is a simplified method which is based on how much time is available to complete the action, with consideration included for environmental and personal factors that could influence the human's reliability. This method is expected to provide a conservative value or placeholder as a preliminary estimate. This preliminary estimate or screening value is used to determine which placeholder needs a more detailed assessment. The second methodology is used to develop a more detailed human reliability assessment on the performance of critical human actions. This assessment needs to consider more than the time available, this would include factors such as: the importance of the action, the context, environmental factors, potential human stresses, previous experience, training, physical design interfaces, available procedures/checklists and internal human stresses. The more detailed assessment is expected to be more realistic than that based primarily on time available. When performing an HRA on a system or process that has an operational history, we have information specific to the task based on this history and experience. In the case of a Probabilistic Risk Assessment (PRA) that is based on a new design and has no operational history, providing a "reasonable" assessment of potential crew actions becomes more challenging. To determine what is expected of future operational parameters, the experience from individuals who had relevant experience and were familiar with the system and process previously implemented by NASA was used to provide the "best" available data. Personnel from Flight Operations, Flight Directors, Launch Test Directors, Control Room Console Operators, and Astronauts were all interviewed to provide a comprehensive picture of previous NASA operations. Verification of the assumptions and expectations expressed in the assessments will be needed when the procedures, flight rules, and operational requirements are developed and then finalized.

DeMott, Diana L.↗

Designing silicon carbide heterostructures for quantum information science: challenges and opportunities

Abstract Silicon carbide (SiC) can be synthesized in a number of different structural forms known as polytypes with a vast array of optically active point defects of interest for quantum information sciences. The ability to control and vary the polytypes during SiC synthesis may offer a powerful methodology for the formation of new material architectures that expand our ability to manipulate these defects, including extending coherence lifetimes and enhancing room temperature operation. Polytypic control during synthesis presents a significant challenge given the extreme conditions under which SiC is typically grown and the number of factors that can influence polytype selection. In situ monitoring of the synthesis process could significantly expand our ability to formulate novel polytype structures. In this perspective, we outline the state of the art and ongoing challenges for precision synthesis in SiC. We discuss available in situ x-ray characterization methods that will be instrumental in understanding the atomic scale growth of SiC and defect formation mechanisms. We highlight optimistic use cases for SiC heterostructures that will become possible with in situ polytypic control and end by discussing extended opportunities for integration of ultrahigh quality SiC materials with other semiconductor and quantum materials.

Harmon, K. J. (ORCID:0000000164277971)↗

Current Status of Martian Moons eXploration (MMX) Contamination Control and Curation Activity

Martian Moons eXploration (MMX) is a sample return mission from the Martian moon Phobos. The MMX spacecraft is scheduled to launch in 2026 and return to Earth in 2031. The main science goals of MMX are “to reveal the origin of the Martian moons and make progress in the understanding of planetary system formation and material transport in the solar system, and to observe processes that impact the circumplanetary and surface environments of Mars”. MMX has two sampling systems: coring (C)-sampler and pneumatic (P)-sampler and plans to bring back >10 g of Phobos sample. The retuned sample in the sample capsule will be transferred to the curation facility in ISAS/JAXA for sample curation and subsequent sample analysis. Contamination control of the sample return mission requires special care to prevent terrestrial contamination to the spacecraft, which would ruin the scientific value of the returned sample. Retaining the pristineness of the retuned sample is an important task of the MMX Curation and Sampler Science teams. The basis of the contamination control is (1) to minimize and understand the nature and amount of contaminants, (2) to perform contamination assessment and evaluate the effect of contaminants in the spacecraft on the retuned sample, (3) to employ a contamination knowledge (CK) material coupon in the spacecraft to identify the contaminants in the returned samples. In the MMX contamination control plan, the allowable contamination level for each contaminant is carefully defined. They are mostly set to be 1/1000 of the expected amount of each material in the returned sample and are divided into two main categories: organic and inorganic. The allowable atmospheric leakage rate to the sample container is also defined. The allowable contamination level of the organic materials is based on the composition of carbonaceous chondrites. The target contaminants are amino acids, aliphatic and aromatic hydrocarbons, carboxylic acids, etc. In case of the inorganic materials, the target contaminants are important elements to permit distinguishing the origin of the Martian moon by nucleosynthetic isotope anomalies (Cr, Ti, and Mo) and to reveal the evolution of the Martian moon by chronology (Hf, W, U, Pb, Rb, Sr, Sm, and Nd). The key instrument of contamination control in the sample return mission is the sampler system. The C-sampler has been developed by JAXA and the P-sampler was provided by Honeybee/NASA. In MMX, materials used in the two samplers (C- and P- sampler) were carefully selected to avoid potential contamination from the design stage of the system. The individual parts of the C-sampler FM (Flight Model) were thoroughly cleaned at the curation facility in ISAS/JAXA by the full-course cleaning procedure, which is an ultrasonic cleaning with organic solvents and ultrapure water in several steps. The equivalent level of cleaning was also carried out on the P-Samper FM as well by Honeybee Robotics in the USA. Now, MMX is in the critical phase for contamination control called ATLO: Assembly, Test, and Launch Operations. During the ATLO phase, sampler FM is constantly purged with nitrogen gas and maintained at positive pressure to prevent environmental contamination. The surrounding environments of the sampler FM are also simultaneously monitored using the CK Monitoring Coupon Set, which consists of several witness materials such as a glass petri dish, sapphire glass disk, and carbon adhesive tape (Figure 1). The detailed environmental assessment of each clean room used for the assembly and test of the sampler FM has also been conducted. This assessment includes microbial analysis, which was performed for OSIRIS-REx. Regarding the sample recovery and sample curation, we have started the designing of Sample Container Disassembling Instrument for the sample recovery from the sample container and the MMX curation chamber for sample curation. The curation protocol for the Phobos returned sample has also been discussed by the MMX Sample Analysis Working Team (SAWT). The MMX curation protocol consists of three phases: (1) quick analysis, (2) pre-basic characterization, and (3) basic characterization. (1) is extraction of the sample gas from the sample container and analysis by mass spectrometry, (2) is observation in bulk level, and (3) is observation in grain level and allocation of the sample aliquots. In parallel with the curation protocol, the returned sample undergoes preliminary examination for scientific investigations to achieve science goals. In addition, the CK witness plates made of sapphire glass are on board the sampler system. The CK witness plates will be recovered from the sampler system and analyzed by SAWT for the assessment of in-flight contamination.

Haruna Sugahara↗

Anisotropic 2D excitons unveiled in organic-inorganic quantum wells

Here we report that two-dimensional (2D) excitons arise from electron-hole confinement along one spatial dimension. Such excitations are often described in terms of Frenkel or Wannier limits according to the degree of exciton spatial localization and the surrounding dielectric environment. In hybrid material systems, such as the 2D perovskites, the complex underlying interactions lead to excitons of an intermediate nature, whose description lies somewhere between the two limits, and a better physical description is needed. Here, we explore the photophysics of a tuneable materials platform where covalently bonded metal-chalcogenide layers are spaced by organic ligands that provide confinement barriers for charge carriers in the inorganic layer. We consider self-assembled, layered bulk silver benzeneselenolate, [AgSePh] ∞ , and use a combination of transient absorption spectroscopy and ab initio GW plus Bethe-Salpeter equation calculations. We demonstrate that in this non-polar dielectric environment, strongly anisotropic excitons dominate the optical transitions of [AgSePh] ∞ . We find that the transient absorption measurements at room temperature can be understood in terms of low-lying excitons confined to the AgSe planes with in-plane anisotropy, featuring anisotropic absorption and emission. Finally, we present a pathway to control the exciton behaviour by changing the chalcogen in the material lattice. Our studies unveil unexpected excitonic anisotropies in an unexplored class of tuneable, yet air-stable, hybrid quantum wells, offering design principles for the engineering of an ordered, yet complex dielectric environment and its effect on the excitonic phenomena in such emerging materials.

36 MATERIALS SCIENCE↗

Ultra-Low SWaP CO 2 Sensing for Demand Control Ventilation (Final Report)

In this project PARC and Energy ETC aimed to develop an ultra-low cost, size, weight, and power (SWaP) printed CO 2 sensor system for occupancy detection to enable Demand Control Ventilation (DCV) on a per-room basis. The CO 2 sensor technology is based on the temperature variation when CO 2 reversibly physisorbs to a highly conductive and high surface area sorbent surface, and is compatible with integration with PARC innovations in printed sensors and flexible electronics, for which PARC is a globally leading research center. The printed CO 2 sensor itself is designed to be compatible with PARC’s “peel-and-stick” platform of ultra-low power, low-cost, distributed sensors, and to facilitate real-time DCV based on overall indoor air quality (IAQ). Previously, PARC has developed flexible hybrid electronics (FHE) compatible materials to measure humidity, temperature, light, strain, and gases such as carbon monoxide, methane, ammonia, and hydrogen sulfide. Through this project, PARC developed FHE-compatible materials to measure CO 2 . Thus, with one <$15 FHE “peel-and-stick” based sensor node, a building management system (BMS) will be able to capture a complete picture of the indoor environment. This includes IAQ, light, temperature, and other comfort factors that impact building operations. Combined with optimized DCV, this low-cost sensor capability can be a key enabler of annual primary energy savings of ~ 0.3-0.4 Quad in commercial buildings while ensuring healthy IAQ. Energy ETC is a leader in supplier-agnostic BMS deployments and will design the commissioning and deployment procedures to maximize system interoperability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing Fundamental Properties of Ionic Liquids for Colloid Microthruster Applications

NASA's New Millennium Program is scheduled to test a Disturbance Reduction System (DRS) on Space Technology 7 (ST7) as part of the European Space Agency's (ESA's) LISA Pathfinder Mission in late 2009. Colloid Micronewton Thrusters (CMNTs) will be used to counteract forces, mainly solar photon pressure, that could disturb gravitational reference sensors as part of the DRS. The micronewton thrusters use an ionic liquid, a room temperature molten salt, as propellant. The ionic liquid has a number of unusual properties that have a direct impact on thruster design. One of the most important issues is bubble formation before and during operation, especially during rapid pressure transitions from atmospheric to vacuum conditions. Bubbles have been observed in the feed system causing variations in propellant flow rate that can adversely affect thruster control. Bubbles in the feed system can also increase the likelihood that propellant will spray onto surfaces that can eventually lead to shorting high voltage electrodes. Two approaches, reducing the probability of bubble formation and removing bubbles with a new bubble eliminator device in the flow system, were investigated at Busek Co., Inc. and the Jet Propulsion Laboratory (JPL) to determine the effectiveness of both approaches. Results show that bubble formation is mainly caused by operation at low pressure and volatile contaminants in the propellant coming out of solution. A specification for the maximum tolerable level of contamination has been developed, and procedures for providing system cleanliness have been tested and implemented. The bubble eliminator device has also been tested successfully and has been implemented in recent thruster designs at Busek. This paper focuses on the propellant testing work at JPL, including testing of a breadboard level bubble eliminator device.

bubble formation↗

PGSFR General Arrangement

The Nuclear Island of the PGSFR is constructed upon the seismic isolation structure bearing a common basemat of the Reactor Building and the Auxiliary Building. The Reactor Building is divided into two different functional structures: 1) containment structure comprised of a operating floor, head access area (HAA), annulus area and etc., 2) the other areas accessible to reactor vault area outside of the containment structure via the Auxiliary Building. The arrangement of the Auxiliary Building is composed of symmetric divisional areas where there are two steam generators, heat exchangers of the Decay Heat Removal System (DHRS), facilities of the Intermediate Sodium Purification System (ISPS), the Primary Inert Gas Processing System (PIGPS), a main control room (MCR), electric equipment rooms, and main steam valve houses (MSVH), and etc. The general arrangement of the Reactor Building and the Auxiliary Building of the PGSFR is currently in development. Not only NSSS but supporting systems have not been finalized yet. Moreover, the other facility buildings such as a Turbine Generator Building, a fuel cycle facility, radwaste treatment facilities, and etc. have to be designed with relevant interfaces to the Reactor Building and the Auxiliary Building. We can expect additional modifications to optimize the general arrangement. However, the basic principles such as sodium and non-sodium segregation, convenient accessibility and maintenance, economics of architectural volume would be kept in the design. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modular Hydronic Room Conditioning System (CRADA NFE-24-10120 Final Report)

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin-tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗