Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

SU-G-IeP3-09: Investigating the Interplay of Antiscatter Grids with Modern Detectors and Image Processing in Digital Radiography

Purpose: To use phantom and simulation experiments to relate technique factors, patient size and antiscatter grid use to image quality in portable digital radiography (DR), in light of advancements in detector design and image processing. Methods: Image contrast-to-noise ratio (CNR) on a portable DR system (MobileDaRt Evolution, Shimadzu) was measured by imaging four aluminum inserts of varying thickness, superimposed on a Lucite slab phantom using a pediatric abdominal protocol. Three thicknesses of Lucite were used: 6.1cm, 12cm, and 18.2cm, with both 55 and 65 kVp beams. The mAs was set so that detector entrance exposure (DEE) was matched between kVp values. Each technique and phantom was used with and without an antiscatter grid (focused linear grid embedded in aluminum with an 8:1 ratio). The CNR-improvement-factor was then used to determine the thickness- and technique-dependent appropriateness of grid use. Finally, the same experiment was performed via Monte Carlo simulation, integrating incident energy fluence at each detector pixel, so that effects of detector design and image processing could be isolated from physical factors upstream of the detector. Results: The physical phantom experiment demonstrated a clear improvement for the lower tube voltage (55kVp), along with substantial CNR benefits with grid use for 12–18cm phantoms. Neither trend was evident with Monte Carlo, suggesting that suboptimal quantum-detection-efficiency and automated grid-removal could explain trends in kVp and grid use, respectively. Conclusion: Physical experiments demonstrate marked improvement in CNR when using a grid for phantoms of 12 and 18cm Lucite thickness (above ∼10cm soft-tissue equivalent). This benefit is likely due to image processing, as this result was not seen with Monte Carlo. The impact of image processing on image resolution should also be investigated, and the CNR benefit of low kVp and grid use should be weighed against the increased exposure time necessary to achieve adequate DEE.

60 APPLIED LIFE SCIENCES↗

Some recent results from ICARUS

ICARUS T600 is the largest Liquid Argon (LAr) Time Projection Chamber (TPC) ever built. Thanks to the excellent spatial and calorimetric resolutions and the three-dimensional visualization capabilities ICARUS T600 represents a major milestone towards the realization of future LAr detectors for neutrino physics and for the search of rare events. Three new important results from the analysis of the events collected by this detector will be here shortly presented: in particular the new improved results on the electron neutrino search, the results on the determination of the muon momentum using the Multiple Scattering and the new LAr purification methods and improvements of the electron lifetime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Parametrizing the detector response with neural networks

In high energy physics, characterizing the response of a detector to radiation is one of the most important and fundamental experimental tasks. In many cases, this task is accomplished by parameterizing summary statistics of the full detector response probability density. The parameterized detector response can then be used for calibration as well as for directly improving physics analysis sensitivity. This paper reports on how to parameterize summary statistics of the detector response using neural networks. Specifically, neural networks are powerful tools for incorporating multidimensional data and the loss function used during training determines which summary statistic is learned. One common summary statistic that has not been combined with deep learning (as far as the authors are aware) is the mode. A neural network-based approach to mode learning is proposed and empirically demonstrated in the context of high energy jet calibrations. Altogether, the neural network-based toolkit for detector response parameterization can enhance the utility of data collected at high energy physics experiments and beyond.

47 OTHER INSTRUMENTATION↗

Detection of high energy muons with sub-20 ps timing resolution using L(Y)SO crystals and SiPM readout

Precise timing capability will be a key aspect of particle detectors at future high energy colliders, as the time information can help in the reconstruction of physics events at the high collision rate expected there. Other than being used in detectors for PET, fast scintillating crystals coupled to compact Silicon Photomultipliers (SiPMs) constitute a versatile system that can be exploited to realize an ad-hoc timing device to be hosted in a larger high energy physics detector. In this paper, we present the timing performance of LYSO:Ce and LSO:Ce codoped 0.4% Ca crystals coupled to SiPMs, as measured with 150 GeV muons at the CERN SPS H2 extraction line. Small crystals, with lengths ranging from 5 mm up to 30 mm and transverse size of 2×2mm 2 or 3×3mm 2 , were exposed to a 150 GeV muon beam. SiPMs from two different companies (Hamamatsu and FBK) were used to detect the light produced in the crystals. The best coincidence time resolution value of (14.5±0.5)ps , corresponding to a single-detector time resolution of about 10 ps, is demonstrated for 5 mm long LSO:Ce,Ca crystals coupled to FBK SiPMs, when time walk corrections are applied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geant4-based multiphysics simulation toolkit for analysis of radiation detector performance

Often only a single physical process or component is investigated in the simulation of radiation detector systems. The results are then considered to be representative of what is expected in the correlating physical experiment. Although singular assessments may serve as a good estimate, the overall performance of a radiation detector system depends on several physical processes and the performance of all components within the system. Our Geant4-based multiphysics simulation toolkit couples radiation transport with optical photon processes, providing simulations of radiation detector systems components from the scintillator through the photocathode of the photodetector. Work to incorporate the back-end detector components, including the complete photodetector and subsequent electronics (e.g., amplifiers, digitizers), is underway. Geant4 is used to model the radiation transport and optical photon processes that occur in the front-end detector system components when exposed to a chosen source. These components include the scintillator, detector housing, optical coupling to the photodetector, and photocathode of the photodetector. Characteristics of several detector systems that have been studied include time response; pulse height spectra; number of photoelectrons per MeV; detector efficiency versus incident quanta energy; and effects on detector response due to change in geometries, materials, and reflectivity. Comparison of these characteristics by means of this toolkit enables the selection of the optimal individual components; thus, it is possible to specify the radiation detector system best suited to meet the requirements of any physical experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SAND detector for the DUNE experiment

The Deep Underground Neutrino Experiment (DUNE) is a next-generation project aiming to study several neutrino properties. It will feature two experimental setups: a near detector that will be installed at Fermilab, in proximity of the neutrino-production point, and a far detector at a distance of 1300 km and 1500 m underground, at the SURF laboratory. The DUNE design and configuration will allow the study of neutrino oscillation, astrophysical neutrinos, and beyond standard model physics. The near detector complex foresees three detectors to be installed. Among these, the System for on-Axis Neutrino Detection (SAND) will serve as on-axis beam monitor, reduce the systematic uncertainties for the oscillation analysis, and search for physics beyond the standard model. SAND will be composed of three sub-detectors, surrounded by a 0.6 T superconducting magnet. The outermost detector will be a lead/scintillating-fiber electromagnetic calorimeter while the inner volume will include a 1-ton liquid argon active target placed upstream followed by a target tracker system. The SAND detector and its goals will be shown in this poster.

Alemanno, Francesca [Salento U.; INFN, Lecce]↗

Search for Gluonic Excitations in Hadrons with GlueX

The GlueX experiment will employ a linearly polarized 9 GeV tagged photon beam incident on a liquid hydrogen target to search for exotic states in the light meson spectrum. Optimized for this purpose, the detector has a highly uniform acceptance over nearly 4p solid angle, with high efficiency for both neutral and charged final state particles. An overview of the physics motivation and detector design will be given.

08 HYDROGEN↗

Oblique incidence effects in direct x-ray detectors: A first-order approximation using a physics-based analytical model

Purpose: The authors describe the modifications to a previously developed analytical model of indirect CsI:Tl-based detector response required for studying oblique x-ray incidence effects in direct semiconductor-based detectors. This first-order approximation analysis allows the authors to describe the associated degradation in resolution in direct detectors and compare the predictions to the published data for indirect detectors. Methods: The proposed model is based on a physics-based analytical description developed by Freed et al. [''A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems,'' Med. Phys. 37(6), 2593-2605 (2010)] that describes detector response functions for indirect detectors and oblique incident x rays. The model, modified in this work to address direct detector response, describes the dependence of the response with x-ray energy, thickness of the transducer layer, and the depth-dependent blur and collection efficiency. Results: The authors report the detector response functions for indirect and direct detector models for typical thicknesses utilized in clinical systems for full-field digital mammography (150 {mu}m for indirect CsI:Tl and 200 {mu}m for a-Se direct detectors). The results suggest that the oblique incidence effect in a semiconductor detector differs from that in indirect detectors in two ways: The direct detector model produces a sharper overall PRF compared to the response corresponding to the indirect detector model for normal x-ray incidence and a larger relative increase in blur along the x-ray incidence direction compared to that found in indirect detectors with respect to the response at normal incidence angles. Conclusions: Compared to the effect seen in indirect detectors, the direct detector model exhibits a sharper response at normal x-ray incidence and a larger relative increase in blur along the x-ray incidence direction with respect to the blur in the orthogonal direction. The results suggest that the oblique incidence effect in direct detectors can be considered to be caused mostly by the geometry of the path where the x-ray beam and its secondary particles deposit energy in the semiconductor layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility study of SiGHT: a novel ultra low background photosensor for low temperature operation

Rare event search experiments, such as those searching for dark matter and observations of neutrinoless double beta decay, require ultra low levels of radioactive background for unmistakable identification. In order to reduce the radioactive background of detectors used in these types of event searches, low background photosensors are required, as the physical size of these detectors become increasing larger, and hence the number of such photosensors used also increases rapidly. Considering that most dark matter and neutrinoless double beta decay experiments are turning towards using noble liquids as the target choice, liquid xenon and liquid argon for instance, photosensors that can work well at cryogenic temperatures are required, 165 K and 87 K for liquid xenon and liquid argon, respectively. The Silicon Geiger Hybrid Tube (SiGHT) is a novel photosensor designed specifically for use in ultra low background experiments operating at cryogenic temperatures. It is based on the proven photocathode plus silicon photomultiplier (SiPM) hybrid technology and consists of very few other, but also ultra radio-pure, materials like fused silica and silicon for the SiPM. Lastly, the introduction of the SiGHT concept, as well as a feasibility study for its production, is reported in this article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operational Characteristics of SiC Diodes as Ionizing Radiation Detectors

In order to explore the possibility of using SiC detectors in nuclear physics applications in extreme environments, the operational characteristics of 4H-SiC Schottky diodes with different dopant concentrations have been studied with {sup 12}C and {sup 16}O ions at various incident energies. The detector response has been investigated in term of linearity, energy resolution, signal rise-time and Charge Collection Efficiency as a function of the applied reverse bias and of the dopant concentration. Moreover, since one of the most promising properties of SiC detectors is their radiation hardness, the radiation damage, produced by irradiating SiC diodes with {sup 16}O ions at 35.2 MeV, has been evaluated by measuring the degradation of both the signal pulse-height and the energy resolution as a function of the {sup 16}O fluence.

36 MATERIALS SCIENCE↗

Quasi-Elastic Neutrino Interactions in the SAND Detector of DUNE

The System for on-Axis Neutrino Detection (SAND) is one of the three components of the DUNE Near Detector Complex. Its main goals are monitoring of the beam, precision measurements of neutrino cross-sections and short-baseline neutrino physics. The SAND detector is composed of a 0.6 T superconducting magnet, an electromagnetic calorimeter, a liquid argon active target (GRAIN) and a modular low-density target system. The GRAIN subdetector has been designed to allow the reconstruction of neutrino interactions in Argon using only the scintillation light, by implementing an innovative imaging system. In this poster, the performances of SAND are presented focusing on its capability to reconstruct νμ+Ar→μ−+p events using the information provided by the calorimeter, the tracking system and GRAIN.

Ingratta, Gianfranco↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lambda baryon production in neutrino-nucleus interactions and light signals reconstruction in the Short-Baseline Near Detector

The field of neutrino physics is nowadays entering the era of precision measurements, with new detectors capable of capturing neutrino interactions with unprecedented detail and high intensity neutrino beams. Liquid Argon Time Projection Chambers (LArTPCs) have become one of the main neutrino detection technologies, providing excellent imaging capabilities and particle identification. The Short-Baseline Near Detector (SBND) at Fermilab is a LArTPC experiment designed to capture neutrinos from the Booster Neutrino Beam (BNB). Its proximity to the beam target (110\,m) and large size (112\,ton) enable the recording of millions of neutrino interactions annually. SBND provides the highest statistics worldwide for neutrino-argon cross-section measurements, facilitating the study of rare channels like Cabibbo-suppressed quasielastic hyperon production. Specifically, this thesis focuses on neutral $\Lambda$ baryon production for which only tens of events have been observed up to date. Our work introduces a novel selection strategy leveraging LArTPC imaging capabilities to identify the distinctive decay signatures of $\Lambda$ baryons, enhancing sensitivity to this channel. Besides being a very mature technology, LArTPCs are an evolving technology. Part of the focus of the new developments lies in harnessing the potential of scintillation light signals. The Photon Detection System (PDS) in SBND has been designed to provide an efficient detection of the scintillation light, representing a major R\&D opportunity in the LArTPC community. Its design provides a high and more uniform light yield, an excellent timing resolution and an independent 3D reconstruction of the events, including the drift coordinate, using exclusively the light signals. This work presents the first comprehensive study of the SBND PDS capabilities. The new developments in the simulation and reconstruction of the light signals in SBND are presented. The whole chain is applied to accurately tag neutrino events through timing information, with a predicted resolution $\mathcal{O}$(2\,ns), and ultimately retrieve the pulse structure of the BNB.

43 PARTICLE ACCELERATORS↗

Radon emanation based material measurement and selection for the SuperNEMO double beta experiment

The SuperNEMO Demonstrator experiment aims to study the neutrinoless double beta decay of 7 kg of {sup 82}Se in order to reach a limit on the light Majorana neutrino mass mechanism T{sub 1/2} (ββ0ν) > 6.5 10{sup 24} years (90%CL) equivalent to a mass sensitivity mβ{sub β} < 0.20 - 0.40 eV (90%CL) in two years of data taking. The detector construction started in 2014 and its installation in the Laboratoire Souterrain de Modane (LSM) is expected during the course of 2015. The remaining level of {sup 226}Ra ({sup 238}U chain) in the detector components can lead to the emanation of {sup 222}Rn gas. This isotope should be controlled and reduced down to the level of a 150 µBq/m{sup 3} in the tracker chamber of the detector to achieve the physics goals. Besides the HPGe selection of the detector materials for their radiopurity, the most critical materials have been tested and selected in a dedicated setup facility able to measure their {sup 222}Rn emanation level. The operating principle relies on a large emanation tank (0.7m{sup 3}) that allows measuring large material surfaces or large number of construction pieces. The emanation tank is coupled to an electrostatic detector equipped with a silicon diode to perform the alpha spectroscopy of the gas it contains and extract the {sup 222}Rn daughters. The transfer efficiency and the detector efficiency have been carefully calibrated through different methods. The intrinsic background of the system allows one to measure 222Rn activities down to 3 mBq, leading to a typical emanation sensitivity of 20 µBq/m{sup 2}/day for a 30 m{sup 2} surface sample. Several construction materials have been measured and selected, such as nylon and aluminized Mylar films, photomultipliers and tracking of the SuperNEMO Demonstrator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Review of the Multiple-Readout Concept and Its Application in an Integrally Active Calorimeter

A comprehensive multi-jet physics program is anticipated for experiments at future colliders. Key physics processes necessitate detectors that can distinguish signals from W and Z bosons and the Higgs boson. Typical examples include channels with or pairs and processes involving new physics in those cases where neutral particles must be disentangled from charged ones due to the presence of W or Z bosons in their final states. Such a physics program demands calorimetric energy resolution at or beyond the limits of traditional calorimetric techniques. Multiple-readout calorimetry, which aims to reduce fluctuations in energy measurements of hadronic showers, is a promising approach. The first part of this article reviews dual- and triple-readout calorimetry within a mathematical framework describing the underlying compensating mechanism. The second part proposes a potential implementation using an integrally active and total absorption detector. This model serves as the basis for several Monte Carlo studies, illustrating how the response of a multiple-readout calorimeter depends on construction parameters. Among the layouts considered, one configuration operating in triple-readout mode shows the potential to achieve an energy resolution approaching .

47 OTHER INSTRUMENTATION↗

Geant4 Computing Performance Benchmarking and Monitoring

Performance evaluation and analysis of large scale computing applications is essential for optimal use of resources. As detector simulation is one of the most compute intensive tasks and Geant4 is the simulation toolkit most widely used in contemporary high energy physics (HEP) experiments, it is important to monitor Geant4 through its development cycle for changes in computing performance and to identify problems and opportunities for code improvements. All Geant4 development and public releases are being profiled with a set of applications that utilize different input event samples, physics parameters, and detector configurations. Results from multiple benchmarking runs are compared to previous public and development reference releases to monitor CPU and memory usage. Observed changes are evaluated and correlated with code modifications. Besides the full summary of call stack and memory footprint, a detailed call graph analysis is available to Geant4 developers for further analysis. The set of software tools used in the performance evaluation procedure, both in sequential and multi-threaded modes, include FAST, IgProf and Open|Speedshop. In conclusion, the scalability of the CPU time and memory performance in multi-threaded application is evaluated by measuring event throughput and memory gain as a function of the number of threads for selected event samples.

97 MATHEMATICS AND COMPUTING↗