Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Study on fabrication of TiO{sub 2} thin films by spin – coating and their optical properties

Study on fabrication of TiO{sub 2} thin films and their optical properties in UV-VIS spectrum has been conducted. TiO{sub 2} nanopowders were prepared by co-precipitation method with varying mixing duration for 5, 10 and 25 hours using TiCl{sub 3} as precursor. The as-synthesized TiO{sub 2} phase is anatase having crystalline size of 14.25 nm, 13.75 nm and 12.62, respectively for the corresponding mixing duration. Thin films of TiO{sub 2} were fabricated by spin coating method and then checked by XRD diffractometer and UV-Vis Spectrophotometer to examine their structure and band gap energy. The prepared films also contain anatase phase of TiO{sub 2} with respective band gap of 3.70 eV, 3.74 eV and 3.76 eV, depending on the powders and their treatment.

36 MATERIALS SCIENCE↗

Nanostructured wear resistant coating for reversible cultivator shovels: An experimental investigation

Cultivator, one of the agriculture farm tool, extensively suffers from the wear problem. In this paper, we report nanostructured chromium nitrite (CrN) coating for the cultivator shovels to mitigate wear problem. The (CrN) coating was developed using DC magnetron sputtering technique at 200 °C. The structural, morphological, hydrophobic and wear properties were investigated using X-ray diffractometer, scanning electron microscope, contact angle goniometer and custom designed soil bin assembly. The XRD reveals that the deposited coating was polycrystalline in nature with cubic structure. Also, The deposited coating was found to be anti wear resistant as well as hydrophobic in nature. The gravimetric wear for the coating developed at 200 °C coated was found out to be 8.15 gm and for non coated it was 14.48 gm tested for 100 hrs. The roughness of the coating plays an important role in determining the hydrophobicity of the coated film. Roughness and contact angle measured for 200 °C coated shovel was found out to be 11.17 nm and 105 ° respectively.

36 MATERIALS SCIENCE↗

Study of structural and optical properties of Fe doped CuO nanoparticles

Iron doped Copper oxide nanoparticles were synthesized by the co-precipitation method at different concentration (3%, 6%, 9%) at 300-400° C with Copper Acetate and Ferric Chloride as precursors in presence of Polyethylene Glycol and Sodium Hydroxide as stabilizing agent. Effect of doping on the structural and optical properties is studied. The obtained nanoparticles were characterized by X-Ray Diffraction and UV-Visible Spectroscopy for examining the size and the band gap respectively. The X-Ray Diffraction plots confirmed the monoclinic structure of Copper oxide suggesting the Cu atoms replaced by Fe atoms and no secondary phase was detected. The indirect band gap of Fe doped CuO nanoparticles is 2.4eV and increases to 3.4eV as the concentration of dopant increases. The majority of particle size is in range 8 nm to 35.55 nm investigated by X-ray diffractometer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Upgrade of small angle x-ray scattering beamline BL-6A at the photon factory

BL-6A has been operational since 2011 as a small angle X-ray scattering (SAXS) beamline at the Photon Factory (PF), and beginning in 2013 its old components and systems, which were mainly inside the experimental hutch, have been extensively updated. Both the vacuum-passes located between the sample stage and the detector and the fixed surface plate have been replaced by a new semi-automatic diffractometer. These upgrades allow simultaneous SAXS/WAXS experiments and grazing-incidence small angle X-ray scattering (GISAXS) measurements to be conducted. The hybrid pixel detector PILATUS3 1M is installed for SAXS, and PILATUS 100K is available as a WAXS detector. Additionally, a pinhole equipped with a micro-ion chamber is available to realize a lower-background and higher-resolution of low angles. Moreover, in a simultaneous SAXS/WAXS experiment, we developed a new beam stop with an embedded photodiode. Thus, BL-6A has evolved into a multipurpose beamline capable of dealing with various types of samples and experimental techniques.

43 PARTICLE ACCELERATORS↗

A suite-level review of the neutron single-crystal diffraction instruments at Oak Ridge National Laboratory

The nascent suite of single-crystal neutron diffractometers at the Oak Ridge National Laboratory has no equal at any other neutron scattering facility worldwide and offers the potential to re-assert single-crystal diffraction using neutrons as a significant tool to study nuclear and magnetic structures of small unit cell crystals, nuclear structures of macromolecules, and diffuse scattering. Signature applications and features of single-crystal neutron diffraction are high resolution nuclear structure analysis, magnetic structure and spin density determinations, contrast variation (particularly D 2 O/H 2 O) for nuclear structural studies, lack of radiation damage when using crystals of biological molecules such as proteins, and the fidelity to measure nuclear and magnetic diffuse scattering with elastic discrimination.

47 OTHER INSTRUMENTATION↗

Next-generation diamond cell and applications to single-crystal neutron diffraction

In this paper, a diamond cell optimized for single-crystal neutron diffraction is described. It is adapted for work at several of the single-crystal diffractometers of the Spallation Neutron Source and the High Flux Isotope Reactor at the Oak Ridge National Laboratory (ORNL). A simple spring design improves portability across the facilities and affords load maintenance from offline pressurization and during temperature cycling. Compared to earlier prototypes, pressure stability of polycrystalline diamond (Versimax®) has been increased through double-conical designs and ease of use has been improved through changes to seat and piston setups. These anvils allow ~30%-40% taller samples than possible with comparable single-crystal anvils. Hydrostaticity and the important absence of shear pressure gradients have been established with the use of glycerin as a pressure medium. Large single-crystal synthetic diamonds have also been used for the first time with such a clamp-diamond anvil cell for pressures close to 20 GPa. The cell is made from a copper beryllium alloy and sized to fit into ORNL’s magnets for future ultra-low temperature and high-field studies. Finally, we show examples from the Spallation Neutron Source’s SNAP and CORELLI beamlines and the High Flux Isotope Reactor’s HB-3A and IMAGINE beamlines.

36 MATERIALS SCIENCE↗

RHEGAL: Resistive heating gas enclosure loadframe for in situ neutron scattering

In situ neutron scattering is a powerful tool to reveal materials atomic structural response such as phase transformation, lattice straining, and texture under external stimuli. The advent of a high flux neutron source such as the Spallation Neutron Source (SNS) allows fast measurement in even non-equilibrium conditions, i.e., phase transformation in steels. However, the commercial fast heating apparatus such as commercial physical simulation equipment is not designed for in situ neutron scattering, which limits its application to in situ materials research by using neutrons. Here we present a resistive heating gas enclosure loadframe (RHEGAL) for non-equilibrium phase transformation studies by using in situ neutron scattering, which takes the advantage of high flux neutron sources like SNS. RHEGAL enables fast resistive heating of metal samples to 1200 °C at a rate up to 60 °C/s in an inert atmosphere. It provides both horizontal and vertical positions for scattering optimization. The mechanical loading capability also allows in situ high temperature tension above the oxidation temperature limit. The optimized translucent neutron scattering window by silicon allows both reflection and transmission measurements, making this equipment applicable for neutron diffraction, small angle scattering, and imaging. Furthermore, to demonstrate the fast heating capability, the phase transformations of an example of advanced high strength steel heated at 3 °C/s and 30 °C/s were measured with the VULCAN engineering diffractometer, and the different phase transformation kinetics by neutron diffraction were presented.

47 OTHER INSTRUMENTATION↗

A suite-level review of the neutron powder diffraction instruments at Oak Ridge National Laboratory

The suite of neutron powder diffractometers at Oak Ridge National Laboratory (ORNL) utilizes the distinct characteristics of the Spallation Neutron Source and High Flux Isotope Reactor to enable the measurements of powder samples over an unparalleled regime at a single laboratory. Full refinements over large Q ranges, total scattering methods, fast measurements under changing conditions, and a wide array of sample environments are available. Here, this article provides a brief overview of each powder instrument at ORNL and details the complementarity across the suite. Future directions for the powder suite, including upgrades and new instruments, are also discussed.

47 OTHER INSTRUMENTATION↗

Probing orientation information using 3-dimensional reciprocal space volume analysis

We present that the crystallographic texture of polycrystalline materials is the result of how these materials are processed and what external forces materials have experienced. Neutron and X-ray diffraction are standard methods to characterize global crystallographic textures. However, conventional neutron and X-ray texture analyses rely on pole figure inversion routines derived from intensity analysis of individual reflections or powder Rietveld analysis to reconstruct and model the orientation distribution from slices through reciprocal space. In this work, we describe an original approach to directly probe the crystallographic texture information of rolled aluminum from the intensity distribution in 3-dimensional reciprocal space volumes measured simultaneously. Using the TOPAZ time-of-flight Laue neutron diffractometer, reciprocal space analysis allowed determination of “pole spheres” with <1° angular resolution. Finally, these pole spheres are compared with reconstructed pole figures from classic texture analysis.

36 MATERIALS SCIENCE↗

Time-of-flight neutron total scattering with applied electric fields: Ex situ and in situ studies of ferroelectric materials

Characterizing the structural response of functional materials (e.g., piezoelectrics and ferroelectrics) to electric fields is key for the creation of structure-property relationships. Here in this paper, we present a new sample environment and data reduction routines which allow the measurement of time-of-flight neutron total scattering during the in situ or ex situ application of high voltage (<10 kV) to a sample. Instead of utilizing the entire detector space of the diffractometer, only selected regions of detector pixels with scattering at the desired angle to the sample electric field are interrogated, which allows the generation of orientation-dependent reciprocal space patterns and real-space pair distribution functions (PDFs). We demonstrate the method using the relaxor ferroelectric Na 1/2 Bi 1/2 TiO 3 and observe lattice expansion parallel and contraction perpendicular to the electric field for both in situ or ex situ experiments, revealing the irreversible nature of the local scale structural changes to this composition. Additionally, changes in the distributions of nearest neighbor metal-oxygen bond lengths are observed, which have been difficult to observe in previously measured analogous orientation-dependent X-ray PDFs. Lastly, considerations related to sample positioning and background subtraction are discussed, and future research directions are suggested.

36 MATERIALS SCIENCE↗

In operando studies of CO oxidation on epitaxial SrCoO 2.5+δ thin films

The high abundance and fast kinetics of select transition metal oxide catalysts are attractive features for many chemical and electrochemical device applications. However, the activity of such catalysts can be accompanied by phase instabilities that prevent their widespread usage. Furthermore, complexities associated with variations in phase behavior and oxygen stoichiometry have hindered studies on the true origins of catalytic activity. Here, we explore the interactions between activity, phase stability, and microstructure using in operando synchrotron X-ray techniques and gas chromatography/mass spectroscopy (GCMS) to probe the behavior of model SrCoO 2.5+δ (SCO) catalysts. Pulsed laser deposition was used to prepare SCO thin films on (001) SrTiO 3 , (111) SrTiO 3 , and pseudocubic (001) DyScO 3 substrates. The GCMS catalytic measurements were performed with a custom-built microreactor compatible with a synchrotron X-ray diffractometer at the Advanced Photon Source. The activity for carbon monoxide oxidation was determined as a function of temperature from 500 °C to 800 °C. We show that the SrCoO 2.5+δ films are active for CO oxidation, most likely by direct reaction with lattice oxygen; consequently, the activity was observed to increase as the films become less stable, with the most active film being the one exhibiting the lowest surface and crystal quality. All films decompose at high temperatures, with in operando diffraction indicating the gradual formation of Sr-rich hexagonal and CoO phases. We find that real-time studies of model oxide systems with synchrotron X-rays is a powerful means of gaining insight into the varied processes taking place at catalytic surfaces.

36 MATERIALS SCIENCE↗

A large field-of-view high-resolution hard x-ray microscope using polymer optics

Here, we present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field X-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross-section is used for uniformly illuminating samples over a large field of view (FoV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wave-front distortions. Using a specific lens-pair designed for 20 keV X-rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FoV, 80 × 80 µm 2 in extent. The results were contrasted with those collected under illumination using commercial two-dimensional parabolic lenses with a smaller FoV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of ‘mesoscopic’ phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.

47 OTHER INSTRUMENTATION↗

Methods for neutron diffraction studies on hydride superconductors and other metal hydrides

High-pressure neutron diffraction is an extremely useful technique in the quest for making and understanding novel hydride superconductors. Neutron diffraction can be used to directly determine elemental stoichiometries and atomic positions of many light elements such as hydrogen or deuterium, even in the presence of heavy elements such as rare-earth metals. In this work, we report on the current status and ongoing developments on high-pressure neutron diffraction for hydride superconductors and other metal hydrides with a special focus on current advancements at the Spallation Neutrons and Pressure (SNAP) beamline of the Spallation Neutron Source at Oak Ridge National Laboratory. For broader context, an overview of high-pressure neutron diffractometers and pressure cells is included together with insight into critical sample considerations. There, attention is given to the requirements for powdered hydride samples and the need for deuterium rather than hydrogen. Additionally, the advantages of angular access and data representation as possible at SNAP are described. We demonstrate the current capability for high-pressure neutron diffraction on two different samples created via hydrogen gas loading, specifically pure deuterium and nickel-deuteride. The deuterium example highlights the usefulness of adding sample materials that facilitate the formation of a good powder while the nickel-deuteride example demonstrates that atomic deuterium positions and stoichiometry can be directly determined. Both examples highlight the importance of large scattering apertures. These enable investigation of the data resolved by scattering angle that is needed to identify parasitic peaks and background features. Finally, future directions beyond current high-pressure neutron powder diffraction are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron Total Scattering Analysis of Materials for the Nuclear Fuel Cycle

Here, this paper reviews recent experimental efforts at the University of Tennessee and Oak Ridge National Laboratory to comprehensively characterize the structural details of materials relevant for the nuclear fuel cycle by employing advanced neutron scattering techniques. For the study of nuclear ceramics, neutron scattering offers distinct advantages over traditional laboratory or synchrotron X-ray diffraction, including enhanced sensitivity to elements with a low atomic mass, such as oxygen, nitrogen, and carbon. The key to these efforts is the recent advancement in the neutron scattering infrastructure at the high-flux diffractometers at the Spallation Neutron Source. The high neutron flux at these instruments enables neutron total scattering, a nondestructive bulk technique that simultaneously captures both short-range structural effects through pair distribution function analysis and long-range order through diffraction pattern analysis. This approach is particularly important for a comprehensive description of defective, disordered, or amorphous nuclear materials. The case studies presented here include analyses of the local defect structure in hyperstoichiometric uranium oxides and short-range order of ion-irradiated ceramics. This advanced analytical methodology will improve our understanding of the behavior of materials in extreme environments and contribute to the development of more resilient nuclear materials.

Neutron scattering↗

High pressure neutron diffraction on WAND 2 with a Paris-Edinburgh press

The Paris-Edinburgh press is a widely available, highly adaptable pressure cell commonly used while collecting neutron scattering data. Here, we detail the use of the VX3 and VX5 Paris-Edinburgh presses on the Wide-Angle Neutron Diffractometer (WAND 2 ) at the High Flux Isotope Reactor at Oak Ridge National Laboratory. We first give a detailed overview of the instrument setup and alignment capabilities used at WAND 2 . We then demonstrate the high pressure capabilities through three examples. In this work, the first example focuses on diffraction data obtained from a lithium-diamond mixture to 10 GPa with the use of single toroidal cubic boron nitride anvils. Other examples include the room temperature compressions of germanium (up to 16 GPa) and the mineral malachite with double toroidal sintered diamond anvils. This work thereby represents the first studies above 10 GPa at the High Flux Isotope Reactor and opens the door for future user experiments at these elevated pressures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A novel compact end-loaded piston cylinder cell for high pressure neutron scattering up to 5 GPa

Here, a miniature sized end-loaded piston cylinder cell with radial side windows for neutron scattering experiments is described. The principle of the bicone-shaped cylinders used was first presented by McWhan in 1974. The present cell is of compact portable design yet significantly enlarges the scattering angles. Its small size allows neutron scattering experiments at low temperatures. The bicone-shaped cylinders are made from various ceramics or a highly neutron-transmissive Ni-free Cr–Mo–V steel. Successful neutron scattering experiments up to 5 GPa have been demonstrated on the CORELLI single-crystal diffractometer and the VISION vibrational spectrometer of the Spallation Neutron Source at the Oak Ridge National Laboratory.

Neutrons↗

Structural differences between single crystal and polycrystalline UBe 13

Here, we report on observations of structural and chemical differences between samples of UBe 13 that were synthesised using two different methods. Unexplained discrepancies in properties between samples with differing synthesis had previously been found in this heavy fermion superconductor. A polycrystalline UBe 13 sample was made by arc-melting the constituents. Single crystals were grown using an aluminium flux and had a consistently slightly larger lattice parameter than the polycrystals, which merited further study. Neutron diffraction data were collected at the Lujan Center at LANSCE on the HIPPO diffractometer. Aluminium was detected by inductively coupled plasma mass spectrometry (ICP-MS) in the flux-grown single crystal (0.803 wt%), and small amounts (~0.2 wt%) of thorium were detected in the UBe 13 polycrystalline sample. In order to probe the implications of the presence of Al, calculations by spin-polarised DFT-GGA+U show that the incorporation of Al onto the 96i site (the lowest symmetry site in the structure) is energetically more favourable than on other sites. In general, the trends calculated by DFT for bond lengths and lattice parameter increases are consistent with bond lengths experimentally observed by neutron diffraction, but specific percentage changes with aluminium incorporation may be obscured by the unexpected thorium in the polycrystalline sample. The aggregate of our initial observations suggests that incorporation of aluminium from the flux into single crystal UBe 13 is significant.

36 MATERIALS SCIENCE↗

Isotropic Thermal Expansivity and Anisotropic Compressibility of ReB2

We experimentally investigated some of the mechanical properties of ReB{sub 2} under high temperature/pressure (T/P) conditions. High-T experiments (up to 600 C at 1 atm) were carried out in a high-T oven attached to a conventional X-ray diffractometer whereas high-P experiments (up to about 42 GPa at 25 C) were conducted in a diamond-anvil cell using synchrotron X-ray radiation. High-T data suggest a highly isotopic thermal expansivity whereas high-P data suggest a highly anisotropic compressibility for ReB{sub 2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗