Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Correlation between microstructure and residual stress formation in friction stir welded armor steels characterized by neutron diffraction

Friction stir welding (FSW) is a solid-state joining process that minimizes the heat-affected zone (HAZ) compared with fusion-based arc welding, making it well suited for joining martensitic armor steels where hardness and ballistic resistance are critical. This study investigates residual stress formation in three defect-free FSW butt-joint configurations relevant to armored-vehicle fabrication: similar rolled homogeneous armor (RHA–RHA, Case 1), similar high-hardness armor (HHA–HHA, Case 2), and dissimilar HHA–RHA (Case 3) joints produced under temperature-controlled conditions (770 °C). Neutron diffraction was employed to quantify the magnitude and spatial distribution of residual stresses in the longitudinal, transverse, and normal directions and to correlate them with weld microstructure and hardness. Tensile residual stresses were concentrated in the softened HAZ, reaching approximately 300 MPa for Case 2 and 400 MPa for Case 1 (≈50–70 % of the base-metal yield strength; ∼581 MPa for RHA and ∼566 MPa for HHA), while compressive residual stresses dominated the stir zone. The spatial extent of tensile stresses scaled with the width of the softened HAZ, which was largest in the dissimilar HHA–RHA joint and smallest in the HHA–HHA joint. Full-width-at-half-maximum (FWHM) analysis revealed low microstrain in overtempered HAZ regions and high microstrain in the stir zone associated with severe plastic deformation and fresh martensite formation. This work demonstrates that residual stress evolution in FSW of martensitic armor steels is governed not primarily by peak temperature or thermal contraction, as inferred from fusion-welding analogies, but by the competition between transformation-induced volumetric expansion and tempering-induced stress relaxation. The relative dominance of these mechanisms is shown to depend on alloy hardenability and local thermal history, leading to more extensive HAZ softening and broader tensile stress regions in the lower-hardenability RHA steel. These findings establish a transferable mechanistic framework for optimizing solid-state joining strategies in high-strength steels and other transformation-hardening alloys beyond armor applications.

Friction stir welding↗

Vegetation biogeography is a main source of uncertainty in modelling the land carbon cycle

The terrestrial biosphere exchanges a large amount of CO 2 with the atmosphere through photosynthesis and respiration, determining the magnitude of land carbon sink and consequently influencing the rate of global warming. The magnitudes of global photosynthesis and respiration, however, vary widely across models (100-200 PgC/year), constituting a key and persistent source of uncertainty in carbon cycle and climate modelling. Here, we argue that the uncertainty in the land carbon cycle modelling is largely attributable to the uncertainty in biogeography – the distribution of plant functional types (PFTs). Using an ensemble of dynamic global vegetation models (DGVMs), we find a strong dependence of total photosynthesis on total area for each PFT. The dependence allows us to reduce the spread of land carbon cycle estimates by ~75% using remote sensing-based PFT maps. We further find that 56 ± 21% of climate-driven changes in global photosynthesis modelled by DGVMs are caused by changes in PFT distribution in the last two decades. Our study identifies vegetation biogeography as a main controlling factor of uncertainty in land carbon cycle modelling and highlights the importance of biogeography-climate interactions in carbon cycle and climate studies.

Zhao, Ruiying [National Univ. of Singapore (Singap↗

Asymmetric linker generates intrinsically disordered metal–organic framework with local MOF-74 structure

Here, we report an intrinsically disordered MOF in the MOF-74 family, Mg 2−x (as-dobpdc) (as-dobpdc 4− = 3′,4-dioxidobiphenyl-3,4′-dicarboxylate). Despite the absence of crystallinity, this material exhibits local ordering consistent with that of its crystalline isomers, maintains porosity, and exhibits a high density of open metal sites. Metal–organic frameworks (MOFs) are typically valued for their combination of crystallinity, porosity, and tunability. However, amorphous MOFs can retain local order while introducing advantages, such as broader distribution of active sites types, reduced thermal conductivity, and emergent modes of tunability via control over the type of disorder. Conventional amorphization strategies rely on external stimuli including pressure, temperature, stress, electrical discharge, or fast precipitation. Recently, amorphous MOFs have been accessed directly using low symmetry organic linkers.

Dinakar, Bhavish [Massachusetts Institute of Techn↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Real Time Phasor Analytics (RTPA) and RTPA-SCR System Strength Online Tool

This presentation showcases the Real-Time Phasor Analytics (RTPA) framework for monitoring inertia and assessing system strength in power grids. RTPA is an open-source tool designed to standardize access to data from Power Management Units (PMUs) and Phasor Data Concentrators (PDCs). It facilitates real-time connectivity to multiple PDCs in accordance with the IEEE C37.118-2 standard and supports asynchronous data stream integration. Additionally, RTPA can simulate a PDC server streaming C37.118-2 data and provides Python bindings for seamless interaction with the framework, eliminating the need for direct Rust programming.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Controlled Placement of Trivalent Heteroatoms in MFI Zeolite Frameworks Using Structure-Directing Agents

MFI zeolites contain distinct confining pore environments, either smaller (∼0.55 nm) channels or larger (∼0.70 nm) intersections. The substitution of trivalent heteroatoms generates Brønsted acid sites of varying acid strength, which, together with their location within different pore environments, dictates the stability of transition states via electrostatic (ion-pair) and van der Waals interactions. Here, we report that structure-directing agents (SDAs) that control Al 3+ substitutional patterns during MFI crystallization analogously position other trivalent heteroatoms (Ga 3+ , Fe 3+ , B 3+ ), altering the distribution of acid sites between channels and intersections, as probed by low-temperature (403 K) toluene methylation kinetics. Heteroatom-substituted MFI crystallized with tetrapropylammonium result in low selectivity toward p-xylene (<30%), while those crystallized using (co-)SDAs containing peripheral hydrogen-bonding groups (e.g., ethylenediamine) show high p-xylene selectivity (∼80%). These selectivities are consistent with DFT-calculated Gibbs free energy barriers for intersection-dominant and channel-dominant active site distributions, respectively. Transition states to form each xylene isomer are similar in size and charge; thus, their rate constants decrease with acid strength similarly, causing isomer selectivity to depend strongly on confinement but not on acid strength. These generalizable synthetic strategies enable independently controlling acid site strength and location in MFI zeolites and, in turn, catalytic rates and selectivities.

36 MATERIALS SCIENCE↗

Distribution of nickel(II) ions adsorbed at the muscovite mica (001)-water interface determined by in-situ resonant anomalous X-ray reflectivity

Mineral-water interfaces mediate adsorption, ion exchange, and secondary mineral formation that control element mobility in natural and engineered systems. Reliable prediction and control of these processes require a fundamental understanding of the interfacial structure that links adsorbed ion speciation to macroscopic sorption capacity and strength. Here, we determine atomic-scale changes in hydration and distribution of Ni(II) at the muscovite mica (001)-water interface using in situ high-resolution X-ray reflectivity (XR) and resonant anomalous X-ray reflectivity (RAXR) at 1 mM NiCl2 and pH 5.7. XR reveals reorganization of the primary hydration structure relative to that in deionized water: the water layer adsorbed in the cavity sites at a height of ~1.3 Å disappears, while distinct solution layers emerge at ~2.3, ~4.1, and ~5.6 Å above the basal oxygen plane. RAXR resolves three interfacial Ni(II) species: a dominant outer-sphere complex at 3.65 Å (~80% of the total coverage), a minor inner-sphere complex at 0.75 Å, and a low-coverage, more distant outer-sphere species at 5.63 Å. These three adsorbed Ni(II) species account for a total Ni(II) coverage of 0.54 ± 0.02 ion per unit cell area that compensates for the surface charge. These results highlight the role of interfacial hydration in controlling the speciation and stability of adsorbate cations on the negatively charged mica surface, providing quantitative insight into predicting the geochemical behavior of divalent metal cations in the aqueous environments.

Lee, Sang Soo↗

Uncertainty quantification and sensitivity analysis of a nuclear thermal propulsion reactor startup sequence

The research presented in this article describes progress in applying stochastic methods, uncertainty quantification, parametric studies, and variance-based sensitivity analysis (also known as Sobol sensitivity analysis) to a full-core model of a nuclear thermal propulsion (NTP) system simulated via the radiation transport code Griffin to simulate neutronics. Our goal is to develop a reduced-order (surrogate) model that can be rapidly sampled with perturbations to multiple input parameters. In this NTP system, reactivity and power feedback affect the rotation of control drums (CDs), which is itself controlled by a hybrid proportional-integral-derivative (PID) controller actuated by the power demand and reactivity feedback from the numerical model. This model uses reactor kinetic feedback (mean generation time [Λ] and effective delayed neutron fraction [ β eff ] from a transient Griffin simulation executed via Griffin’s improved quasi-static solver to provide the kinetic parameters) as inputs to functions that control the CD rotation angle. By investigating numerous stochastic approaches, we developed a dual-purpose surrogate model of the NTP system, using polynomial regression in the Multiphysics Object-Oriented Simulation Environment (MOOSE) Stochastic Tools Module (STM). The trained model can be rapidly sampled while simultaneously perturbing various input parameters, such as coefficients on the PID control or temperature (directly affecting the neutron cross section). The surrogate model delivers accurate (within 5%) results at speeds orders of magnitude faster (minutes, not days of computational time) than the base model. Once the surrogate model has been trained, distributions of the uncertain parameters can be changed at will to investigate the effects of perturbing multiple inputs as well as the effects of these inputs on the model output. For example, coefficients used in the PID control system may vary due to some type of physical interference, or uncertainty may exist in the temperature of the neutron cross sections in various regions of the reactor. A distribution can be placed on these parameters, and operational boundaries can be determined. The goal of this work is to support development of an advanced control system for operating CDs in a functioning NTP system. This work is a scoping study of the MOOSE STM.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Modeling the Effects of Artificial Drainage on Agriculture-Dominated Watersheds Using a Fully Distributed Integrated Hydrology Model

In agriculture-dominated watersheds where natural drainage is poor, agricultural ditches (narrow engineered channels) and tile drains (perforated pipes) are widely employed to enhance surface and subsurface drainage, respectively. Despite their relatively small scale, these features exert substantial control over the hydro-biogeochemical function of watersheds and their effects need to be represented in the models. We introduce a novel strategy to incorporate the effects of artificial agricultural drainage into a fully distributed basin-scale integrated surface-subsurface hydrology models. In our approach, narrow agriculture ditches for surface drainage are resolved efficiently using ditch-aligned computational meshes that are hydrologically conditioned to ensure connectivity in the stream/ditch network. For tile drainage in the subsurface, we use the physically based Hooghoudt's drainage equation as a subgrid model and route the water drained through tiles to the nearest ditch. Without site-specific calibration, this model reproduced observed streamflow in the Portage River Watershed (>1,000 km 2 ) as recorded by a USGS gauge with good accuracy (normalized KGE = 0.81) and outperformed a calibrated SWAT model (normalized KGE = 0.68). Numerical experiments confirm that artificial drainage reduces surface inundations and effectively controls the water table. At the watershed scale, artificial drainage increases baseflow but has little effect on watershed discharges above the 90th percentile. The strong physical underpinnings and reduced need for calibration allow us to study the impacts of artificial drainage on distributed hydrological response in terms of fluxes and states and provide a platform for investigating watershed-scale nutrient transport.

54 ENVIRONMENTAL SCIENCES↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

Control and Real-Time Simulation of Microgrids with EV Fast-Charging and Grid-Forming Resources

Fast charging stations (FCSs) for electric vehicles (EVs) can behave as constant power loads, which is problematic for the operation of grid-forming (GFM) inverter-based resources (IBRs). To tackle this problem, this paper proposes a control suite that makes FCSs responsive to ac voltage and frequency disturbances. To test the performance of the FCS controls, the paper also sets forth theory to compensate for time-delays appearing in the real-time simulation of microgrid models divided into several central processing units (CPUs). Furthermore, these contributions are showcased via multi-CPU real-time simulations of a faulted microgrid having EV FCSs and GFM IBRs powered by photovoltaic solar arrays as well as power hardware-in-the-loop experiments. These contributions are significant to address NERC recommendations and IEEE standards.

14 SOLAR ENERGY↗

Effect of 3D-printed surface textures on wear mechanism in 3-body abrasion of soil

This study systematically investigates the enhancement of wear resistance in 3D printed surface textures through both experimental and theoretical approaches. Three distinct surface morphologies (Smooth Surface, Surface with uniformly distributed Pits, and Surface with uniformly distributed Bumps) were fabricated using High-Impact Polystyrene, where the meso-scale textures were precisely controlled through the 3D printing process. Wear behavior was evaluated using a 3-body wear tester in an abrasive particle environment, analyzing the influence of surface textures under various operating conditions. Systematic wear tests revealed that optimally designed surface textures achieved a remarkable 77 % reduction in wear compared to the worst-performing sample. The wear mechanisms were comprehensively characterized through weight loss measurements, Scanning Electron Microscopy (SEM), and Energy Dispersive Spectroscopy (EDS) analyses, elucidating the surface morphology changes and their interaction with wear particles. Notably, the study identified how the geometric characteristics of surface textures influence the movement of wear particles and the distribution of contact stresses. Discrete element method simulations corroborated the experimental findings, providing theoretical validation for the enhanced wear resistance of the optimal structure. The high correlation between simulated wear patterns and experimental results validates the reliability of the proposed design methodology. In conclusion, these results demonstrate that 3D printed surface texturing offers a cost-effective and scalable approach to significantly improve wear resistance in engineering applications, presenting a practical alternative to conventional, high-cost surface engineering methods.

3-body abrasion↗

Near-field-driven radiative thermal dynamics in aperiodic photonic nanostructures

Harnessing structural correlations in near-field plasmonic and polaritonic systems hold untapped potential for controlling light–matter interactions at the nanoscale. By tuning these correlations, one can reshape mode localization, coupling, and spectral distribution which are properties central to manipulating energy transport and field enhancement in nanophotonic platforms. We exploit Vogel spirals, an aperiodic geometry where a single parameter dictates spatial correlations, to show how correlation strength reshapes the modal spectrum and transient dynamics of near-field coupling. As a proof of concept, we demonstrate that aperiodic configurations outperform both uncorrelated (random) and periodic arrays in controlling near-field radiative heat-transfer dynamics. These results establish deterministic aperiodic order as a powerful platform for tailoring correlated electromagnetic responses in next-generation nanophotonic devices.

36 MATERIALS SCIENCE↗

Factors controlling injection-induced rupture of intersecting faults during geological sequestration of CO 2

This study addresses coupled multiphase fluid flow and geomechanics effects on potential fault activation associated with subsurface CO 2 injection around intersecting faults. An enhanced fault-representation model is used to capture geomechanical responses of two intersecting faults with finite length during CO 2 injection. The faults are embedded in a strike-slip stress regime of a caprock-reservoir-basement system with the faults represented by zero-thickness interfaces with adjacent finite-thickness damage zones. A sensitivity analysis is conducted to study the effect of fault permeability, slip-weakening behavior, well location relative to the orientation of faults, and well placement (the number and location of injection wells). Five metrics (pressure, CO 2 plume, shear state on the fault, as well as shear displacement and stress path at selected fault monitoring points) are selected to assess CO 2 migration and reactivation of intersecting faults. The results show that induced ruptures are favored by low permeability faults due to high pressure buildup and by slip-weakening behavior resulting from fault strength reduction. The location of one injection well relative to fault orientation determines the magnitude of changes in effective normal stress and shear stress, affecting the location of induced ruptures. Well placement (two injection wells used in the paper) dominates pressure diffusion around the intersection and tips of faults. This redistributes changes in effective normal stress caused by each injection well, influencing the spatial distribution of ruptures along faults. A larger injection volume induces far-field ruptures that are controlled by stress transfer within the injection layer. The findings presented here can provide valuable insights into engineering operations for a long-term, safe, and reliable geologic CO 2 storage.

Fault permeability↗

New Tank Mapping Method Improves Waste Removal Process

Savannah River Mission Completion is the Liquid Waste (LW) contractor at the Savannah River Site (SRS). The LW mission is tasked with treating and disposing of legacy nuclear waste. There are multiple facilities involved in this work, including the Concentration, Storage, and Transfer Facilities (CSTF), the Defense Waste Processing Facility (DWPF), the Salt Waste Processing Facility (SWPF), and the Saltstone Production Facility (SPF). The CSTF includes 43 underground waste tanks used to store and support processing of radioactive liquid waste. Waste removal activities, such as salt dissolution campaigns and sludge agitation, are conducted within the CSTF waste tanks to convert the waste into a form that allows for downstream processing at other LW facilities. While performing these waste removal campaigns, camera inspections are performed to assess the quantity and distribution of the remaining waste within the waste tank (i.e. saltcake or sludge). Understanding the quantity and distribution of the salt/sludge within the waste tanks allows for improved waste removal strategies (e.g. mixing pump operation) and refined safety controls. Typically, several camera inspections are performed during a waste removal transfer to verify the elevation of the visible salt/sludge mounds against the known elevation of the liquid surface. The camera inspection footage must then be interpreted by a trained engineer who will develop a 2-D map that depicts the waste distribution at various elevations within the waste tank. This tank mapping is then used in conjunction with conservative assumptions to evaluate the volume of saltcake or sludge that is present within the waste tank.

Mini, Melany↗