Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Fairness-Aware Distributed Energy Coordination for Voltage Regulation in Power Distribution Systems

The accelerating deployment of solar photovoltaics into low-voltage distribution networks can cause reverse power flow and overvoltage problems. However, if coordinated properly, the real and reactive power flexibility of these resources enables distribution operators to manage their networks more efficiently. Existing literature is rich in droop-based control (Volt-Watt and Volt-VAr) and optimization-based distributed energy coordination for four-quadrant control of photovoltaics to prevent overvoltage issues. While optimal coordination can effectively mitigate overvoltage, it tends to treat resources at sensitive parts of the grid unfairly. Here, to address this concern, we propose a distributed optimal power flow formulation that incorporates fairness in curtailing photovoltaic generation and utilizes the reactive power capability of smart inverters. The proposed distributed formulation allows for scalable resource aggregation that can be leveraged to achieve fairness within a certain segment of the grid and/or fairness across the entire network. Fair curtailment of photovoltaic systems is demonstrated with aggregation at each of two layers in a distribution network: 1) area-level fairness and 2) feeder-level fairness. To explore the trade-off between fairness and optimal utilization, the fairness-aware control actions are compared against the performance of a centralized controller that aims to maximize the aggregate PV generation without incorporating fairness. Simulation results show that introducing area-level fairness increased curtailment by 0.0101 percentage points and feeder-level fairness increased curtailment by 0.0458 percentage points compared to a fairness-agnostic control.

Poudel, Shiva↗

Optimization of an interactive distributive computer network

The activities under a cooperative agreement for the development of a computer network are briefly summarized. Research activities covered are: computer operating systems optimization and integration; software development and implementation of the IRIS (Infrared Imaging of Shuttle) Experiment; and software design, development, and implementation of the APS (Aerosol Particle System) Experiment.

Frederick, V.↗

Online Model-Free DER Dispatch Via Adaptive Voltage Sensitivity Estimation and Chance Constrained Programming

This paper proposes an online data-driven distributed energy resource management system (DERMS) for distribution system optimal DER dispatch as well as voltage regulation. Here, the key innovation is to leverage the Local Sensitivity Factor (LSF) for transforming the DER control into a computationally efficient linear programming (LP) problem. By taking real-time measurements, the estimation of LSF eliminates the need for an accurate distribution system model as well as full nodal load information, which is difficult to achieve in practice. A robust recursive least squares method is also developed to ensure the robust estimation of LSF, which is initialized using reasonable values from model-derived LSFs. This allows the system to adapt to changing operational conditions effectively. A scenario-based, chance-constrained framework is further employed to ensure voltage remains within acceptable limits in the presence of measurement and estimation uncertainties. Test results on a real-world, 759-node distribution network located in western Colorado, U.S., validate the effectiveness and robustness of the proposed control approach and demonstrate its superior performance as compared to alternative methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Control Allocation for Distributed Electric Propulsion in a Series/Parallel Partial Hybrid Powertrain

The SUbsonic Single Aft eNgine (SUSAN) Electrofan is a NASA concept jet transport aircraft with a 2040 entry-into-service date. It utilizes electrified aircraft propulsion (EAP) to enable propulsive and aerodynamic benefits to reduce fuel usage, emissions, and cost. The powertrain consists of a single thrust producing, boundary layer-ingesting (BLI) turbofan gas turbine engine (GTE) with generators driving a series/parallel partial hybrid EAP system. The architecture includes 16 underwing contrarotating BLI fans, eight on each side, in a mailslot configuration. The 16 fans run on power extracted from the GTE through four 5 MW motor/generators connected to the Low-Pressure Spool, and a single 1 MW motor/generator on the High-Pressure Spool. The distributed fans can be used by the flight control to augment or replace the rudder function. At top of climb, the power extracted from the GTE for the fans is boosted by batteries. The design provides redundancy, and the capacity for boost means that the fans are designed to be able to provide additional thrust when necessary. These features can be leveraged in case of a fan or generator failure. This paper sets up the optimal control problem of setpoint determination for individual fans in the distributed propulsion system, accounting for electrical string efficiencies, saturations, and failures. The solution minimizes power consumption while maintaining thrust and torque on the airframe for maneuvering. Additionally, thrust that would have been lost due to temporary fan speed or power saturation is optimally redistributed to maintain overall desired thrust and torque on the aircraft. The power extraction range constraints derive from the gas turbine engine design and the small amount of variation allowed for the engine to maintain operability. The problem formulation allows the number and location of fan failures for which the thrust and torque can be maintained to be investigated, which has implications for certification. Simulations of a coordinated turn utilizing the distributed electric propulsion for yaw rate control under different failure scenarios demonstrate the robustness of the powertrain design to failures and help define its limitations.

Distributed Electric Propulsion↗

Distributionally Robust Decision Making Leveraging Conditional Distributions

Distributionally robust optimization (DRO) is a powerful tool for decision making under uncertainty. It is particularly appealing because of its ability to leverage existing data. However, many practical problems call for decision-making with some auxiliary information, and DRO in the context of conditional distributions is not straightforward. We propose a conditional kernel distributionally robust optimization (CKDRO) method that enables robust decision making under conditional distributions through kernel DRO and the conditional mean operator in the reproducing kernel Hilbert space (RKHS). In particular, we consider problems where there is a correlation between the unknown variable y and an auxiliary observable variable x. Given past data of the two variables and a queried auxiliary variable, CKDRO represents the conditional distribution P(y|x) as the conditional mean operator in the RKHS space and quantifies the ambiguity set in the RKHS as well, which depends on the size of the dataset as well as the query point. To justify the use of RKHS, we demonstrate that the ambiguity set defined in RKHS can be viewed as a ball under a metric that is similar to the Wasserstein metric. The DRO is then dualized and solved via a finite dimensional convex program. The proposed CKDRO approach is applied to a generation scheduling problem and shows that the result of CKDRO is superior to common benchmarks in terms of quality and robustness.

Chen, Yuxiao↗

Learning Optimal Power Flow Solutions using Linearized Models in Power Distribution Systems

Solving nonlinear optimal power flow (OPF) problem is computationally expensive, and poses scalability challenges for power distribution networks. An alternative to solving the original nonlinear OPF is the linear approximated OPF models. Although, these linear approximated OPF models are fast, the resulting solutions may result in significant optimality gap. Lately, the application of machine learning (ML) methods in successfully solving the nonlinear OPF has been reported. These methods learn and estimate the nonlinear control policies using a purely data-driven approach. In this paper, we propose an approach to complements the ML based approach to solving OPF using solutions from known linearized OPF model. Specifically, we use supervised learning to map the solutions of linear OPF to nonlinear control variables. Unlike, the traditional ML based methods for OPF that approximate the full distribution feeder model using function approximation, our approach uses a two-node approximation of radial networks. The proposed approach is validated using IEEE 123 bus test system for OPF solutions obtained using the nonlinear OPF models.

optimal power flow, power distribution systems, su↗

Optimal field-splitting algorithm in intensity-modulated radiotherapy: Evaluations using head-and-neck and female pelvic IMRT cases

To develop an optimal field-splitting algorithm of minimal complexity and verify the algorithm using head-and-neck (H and N) and female pelvic intensity-modulated radiotherapy (IMRT) cases. An optimal field-splitting algorithm was developed in which a large intensity map (IM) was split into multiple sub-IMs (≥2). The algorithm reduced the total complexity by minimizing the monitor units (MU) delivered and segment number of each sub-IM. The algorithm was verified through comparison studies with the algorithm as used in a commercial treatment planning system. Seven IMRT, H and N, and female pelvic cancer cases (54 IMs) were analyzed by MU, segment numbers, and dose distributions. The optimal field-splitting algorithm was found to reduce both total MU and the total number of segments. We found on average a 7.9 ± 11.8% and 9.6 ± 18.2% reduction in MU and segment numbers for H and N IMRT cases with an 11.9 ± 17.4% and 11.1 ± 13.7% reduction for female pelvic cases. The overall percent (absolute) reduction in the numbers of MU and segments were found to be on average −9.7 ± 14.6% (−15 ± 25 MU) and −10.3 ± 16.3% (−3 ± 5), respectively. In addition, all dose distributions from the optimal field-splitting method showed improved dose distributions. The optimal field-splitting algorithm shows considerable improvements in both total MU and total segment number. The algorithm is expected to be beneficial for the radiotherapy treatment of large-field IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

LONG-TERM MONITORING OF MODE SWITCHING FOR PSR B0329+54

The mode-switching phenomenon of PSR B0329+54 is investigated based on the long-term monitoring from 2003 September to 2009 April made with the Urumqi 25 m radio telescope at 1540 MHz. At that frequency, the change of relative intensity between the leading and trailing components is the predominant feature of mode switching. The intensity ratios between the leading and trailing components are measured for the individual profiles averaged over a few minutes. It is found that the ratios follow normal distributions, where the abnormal mode has a greater typical width than the normal mode, indicating that the abnormal mode is less stable than the normal mode. Our data show that 84.9% of the time for PSR B0329+54 was in the normal mode and 15.1% was in the abnormal mode. From the two passages of eight-day quasi-continuous observations in 2004, supplemented by the daily data observed with the 15 m telescope at 610 MHz at Jodrell Bank Observatory, the intrinsic distributions of mode timescales are constrained with the Bayesian inference method. It is found that the gamma distribution with the shape parameter slightly smaller than 1 is favored over the normal, log-normal, and Pareto distributions. The optimal scale parameters of the gamma distribution are 31.5 minutes for the abnormal mode and 154 minutes for the normal mode. The shape parameters have very similar values, i.e., 0.75{sup +0.22}{sub -0.17} for the normal mode and 0.84{sup +0.28}{sub -0.22} for the abnormal mode, indicating that the physical mechanisms in both modes may be the same. No long-term modulation of the relative intensity ratios was found for either mode, suggesting that the mode switching was stable. The intrinsic timescale distributions, constrained for this pulsar for the first time, provide valuable information to understand the physics of mode switching.

79 ASTRONOMY AND ASTROPHYSICS↗

Power Optimal Control Allocation for Distributed Electric Propulsion in a Series/Parallel Hybrid Powertrain

This paper describes a thrust allocation scheme that minimizes power consumption in an electrified powertrain with Distributed Electric Propulsion. It takes advantage of an observation about component efficiency maps, that efficiency is often highest at high torque/high speed conditions. This optimal approach is demonstrated to satisfy total thrust and net yaw axis torque requirements, making it suitable for utilizing differential thrust for maneuvering.

electrified aircraft propulsion↗

Power Optimal Control Allocation for Distributed Electric Propulsion in a Series/Parallel Hybrid Powertrain

This paper describes a thrust allocation scheme that minimizes power consumption in an electrified powertrain with Distributed Electric Propulsion. It takes advantage of an observation about component efficiency maps, that efficiency is often highest at high torque/high speed conditions. This optimal approach is demonstrated to satisfy total thrust and net yaw axis torque requirements, making it suitable for utilizing differential thrust for maneuvering.

electrified aircraft propulsion↗

Power Optimal Control Allocation for Distributed Electric Propulsion in a Series/Parallel Hybrid Powertrain

This paper describes a thrust allocation scheme that minimizes power consumption in an electrified powertrain with Distributed Electric Propulsion. It takes advantage of an observation about component efficiency maps, that efficiency is often highest at high torque/high speed conditions. This optimal approach is demonstrated to satisfy total thrust and net yaw axis torque requirements, making it suitable for utilizing differential thrust for maneuvering.

electrified aircraft propulsion↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on Banshee Distribution Network

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An optimization technique for lumped-distributed two ports

A frequency domain direct efficient analysis and an optimization technique of a large class of lumped-distributed networks containing active elements are presented. Sensitivity and Hessian matrix calculations are performed using truncated Taylor series expansion of two-port parameters of subnetworks. An interactive computer program was developed to demonstrate the application of the method. Examples of network optimizations are included to illustrate the powerfulness of the technique.

Iobst, K. W.↗

Distributed computer system enhances productivity for SRB joint optimization

The Programming System for Structural Synthesis software package, which couples structural analysis and optimization, has been distributed over a network of work stations for use in Space Shuttle Solid Rocket Booster joint redesign optimization. Finite difference computing techniques were applied to the optimization gradients in parallel execution, allowing several work stations to simultaneously contribute to the problem's solution. An optimal joint shape was obtained which achieves minimum weight while keeping the gap between joints well closed and limiting structural stresses. The optimization cycle was reduced from two hours to one-half hour.

Rogers, James L., Jr.↗

Analytical and Computational Properties of Distributed Approaches to MDO

Historical evolution of engineering disciplines and the complexity of the MDO problem suggest that disciplinary autonomy is a desirable goal in formulating and solving MDO problems. We examine the notion of disciplinary autonomy and discuss the analytical properties of three approaches to formulating and solving MDO problems that achieve varying degrees of autonomy by distributing the problem along disciplinary lines. Two of the approaches-Optimization by Linear Decomposition and Collaborative Optimization-are based on bi-level optimization and reflect what we call a structural perspective. The third approach, Distributed Analysis Optimization, is a single-level approach that arises from what we call an algorithmic perspective. The main conclusion of the paper is that disciplinary autonomy may come at a price: in the bi-level approaches, the system-level constraints introduced to relax the interdisciplinary coupling and enable disciplinary autonomy can cause analytical and computational difficulties for optimization algorithms. The single-level alternative we discuss affords a more limited degree of autonomy than that of the bi-level approaches, but without the computational difficulties of the bi-level methods. Key Words: Autonomy, bi-level optimization, distributed optimization, multidisciplinary optimization, multilevel optimization, nonlinear programming, problem integration, system synthesis

Alexandrov, Natalia M.↗