At least 433 records · Page 24

An electromagnetic/electrostatic dual cathode system for electron beam instruments

A method of providing cathode redundancy which consists of two fixed cathodes and uses electromagnetic and/or electrostatic fields to direct the electron beam to the electron optical axis is presented, with application to the cathode system of the Scanning Electron Microscope and Particle Analyzer proposed for NASA's Mariner Mark II Comet Rendezvous/Asteroid Flyby projected for the 1990s. The symmetric double deflection system chosen has the optical property that the image of the effective electron source is formed above the magnet assembly near the apparent position of the effective source, and it makes the transverse positions of the electron sources independent of the electron beam energy. Good performance of the system is found, with the sample imaging resolution being the same as for the single-axis cathode.

Bradley, J. G.↗

AlGaAs phased array laser for optical communications

Phased locked arrays of multiple AlGaAs diode laser emitters were investigated both in edge emitting and surface emitting configurations. CSP edge emitter structures, coupled by either evanescent waves or Y-guides, could not achieve the required powers (greater than or similar to 500 mW) while maintaining a diffraction limited, single lobed output beam. Indeed, although the diffraction limit was achieved in this type of device, it was at low powers and in the double lobed radiation pattern characteristic of out-of-phase coupling. Grating surface emitting (GSE) arrays were, therefore, investigated with more promising results. The incorporation of second order gratings in distribute Bragg reflector (DBR) structures allows surface emission, and can be configured to allow injection locking and lateral coupling to populate 2-D arrays that should be able to reach power levels commensurate with the needs of high performance, free space optical communications levels. Also, a new amplitude modulation scheme was developed for GSE array operation.

Carlson, N. W.↗

A superconducting tunnel junction receiver for 345 GHz

The design, fabrication, and testing of a quasi-particle tunnel junction receiver for use at 345 GHz are discussed. The design employs small area Nb/Nb-oxide/PbInAu edge junctions in order to keep the device capacitance small and maintain a modest value for omega R(N)C. For optimum noise performance and beam properties the mixer is contained in a waveguide mounting structure. The best sensitivity was obtained at 312 GHz where a double sideband (DSB) noise temperature of 275 K was measured. Noise temperatures of 400 K (DSB) or better were obtained out to 350 GHz.

Sutton, E. C.↗

Robust, sub-angstrom level mid-spatial frequency profilometry

A noncontacting measurement approach is presented that involves the measurement of the local curvature of the test piece by simultaneously measuring its slope at two slightly displaced locations. As the sensing beams are scanned along the test piece, a profile of curvature is built, from which the height profile is deduced by double integration. The sensing of curvature eliminates the need for a reference surface, and makes the approach insensitive to all types of vibration and drift, both in surface height and in surface slope. The approach is considered to be well suited to measuring grazing incidence optics with highly different transverse and longitudinal radii of curvature. Implementation features including a steering mirror and a movable detector provide for servo tracking of test pieces as fast as F-0.5, with radii as small as 20 mm (convex or concave).

Glenn, Paul↗

Electron-Impact Ionization of Mg

A pulsed crossed beam technique is used to measure inonization cross-sections of metallic atoms. Relative values of cross-sections of single, double and triple inonization of magnesium have been successfully measured with good accuracy over the o-700 eV range. Absolute values of cross sections have been obtained by normalization to a theoretical value at high electron energy. Results are compared to previously published values and, for single inonization in particular, a comparison with theoretical cross-extions is perfomed.

Ionization of Mg↗

Detectors and Focal Plane Modules for Weather Satellites

Weather satellite instruments require detectors with a variety of wavelengths ranging from the visible to VLWIR. One of the remote sensing applications is the geostationary GOES-ABI imager covering wavelengths from the 450 to 490 nm band through the 13.0 to 13.6 micron band. There are a total of 16 spectral bands covered. The Cross-track infrared Sounder (CrIS) is a Polar Orbiting interferometric sensor that measures earth radiances at high spectral resolution, using the data to provide pressure, temperature and moisture profiles of the atmosphere. The pressure, temperature and moisture sounding data are used in weather prediction models that track storms, predict levels of precipitation etc. The CrIS instrument contains SWIR (lamba(sub c) approximately 5 micron at 98K), MWIR (lambda(sub c) approximately 9 micron at 98K) and LWIRs (lamba(sub c) approximately 15.5 micron at 81K) bands in three Focal Plane Array Assemblies (FPAAs). GOES-ABI contains three focal plane modules (FPMs), (i) a visible-near infrared module consisting of three visible and three near infrared channels, (ii) a MWIR module comprised of five channels from 3.9 micron to 8.6 micron and (iii) a 9.6 micron to 13.3 micron, five-channel LWIR module. The VNIR FPM operates at 205 K, and the MWIR and LWIR FPMs operate at 60 K. Each spectral channel has a redundant array built into a single detector chip. Switching is thus permitted from the primary selected array in each channel to the redundant array, given any degradation in performance of the primary array during the course of the mission. Silicon p-i-n detectors are used for the 0.47 micron to 0.86 micron channels. The thirteen channels above 1 micron are fabricated in various compositions of Hg1-xCdxTe, and in this particular case using two different detector architectures. The 1.38 micron to 9.61 micron channels are all fabricated in Hg1-xCdxTe grown by Liquid Phase Epitaxy (LPE) using the HDVIP detector architecture. Molecular beam epitaxy (MBE)-grown Hg1-xCdxTe material are used for the LWIR 10.35 micron to 13.3 micron channels fabricated in Double layer planar heterostructure (DLPH) detectors. This is the same architecture used for the CrIS detectors CrIS detectors are 850 micron diameter detectors with each FPAA consisting of nine photovoltaic detectors arranged in a 3 x 3 pattern. Each detector has an accompanying cold preamplifier. SWIR and MWIR FPAAs operate at 98 K and the LWIR FPAA at 81 K, permitting the use of passive radiators to cool the detectors. D* requirements at peak wavelength are ≥ 5.0E+10 Jones for LWIR, ≥ 9.3E+10 Jones for MWIR and ≥ 3.0E+11 Jones for SWIR. All FPAAs exceeded the D* requirements. Measured mean values for the nine photodiodes in each of the LWIR, MWIR and SWIR FPAAs are D* = 5.3 x 10(exp 10) cm-Hz(exp 1/2)/W at 14.0 micron, 1.0 x 10(exp 11) cm-Hz(exp 1/2)/W at 8.0 micron and 3.1 x 10(exp 11) cm-Hz(exp 1/2)/W at 4.64 micron.

satellite instruments↗

Demonstration of a 1-D Submillimeter-Wave Phased Array with MEMS Phase Shifters

At submillimeter-wave frequencies, due to the nonavailability of low-loss phase shifters, electronic antenna beam scanning is difficult to realize. Traditionally, power-hungry and bulky motors are used to mechanically scan the antenna beam. At lower-frequencies, phased array antennas are most commonly used where low-loss phase shifters are used with the array elements to accomplish beam steering. However, development of similar phased array antennas at submillimeter-waves has been challenging. Recently, we have developed a low-loss microelectromechanical systems (MEMS) based phased shifter in the 500-750 GHz band. In this work, we present a submillimeter-wave phased array antenna system with a cavity-backed double slot antenna architecture using the MEMS-based phase shifters. To demonstrate the concept, we developed two arrays: first one is a 8×1 linear antenna array with a fixed waveguide feeding network that achieved ±20◦ beam scanning, 18 dB directivity, and less than 1 dB scan loss over the design frequency of 500–570 GHz. The second one is a 4 × 1 linear antenna array with integrated MEMS-based phase shifters on each array element, achieving 15 dB directivity and capable of dynamic beam scanning over a range of ±9 ◦ . All the plots presented are simulated results since the parts are currently being fabricated. We hope to have access to our assembly and measurement facilities over the next few months and present measured performances at the conference.

Chattopadhyay, G.↗

A high resolution electro-optical displacement measurement system

An improved electrooptical system has been developed to sense wind tunnel model position. The original system using 25.6 mm, 1024-element linear photodiode arrays (PDAs) is being successfully used at a NASA wind tunnel but has a limited range. A new two-channel system using 61.44 mm, 4096-element PDAs has been developed to double the range of vertical and pitch measurement and increase the resolution by 60 percent. The PDAs are illuminated by expanding the beam of a single low power helium neon laser into a collimated sheet of light. An object placed in front of the two parallel PDAs produces a shadow on the array apertures which determines the object's position or size. The system has an overall precision of 12.7 microns and + or - 0.015 degrees in linear and angular measurements.

Schott, Timothy D.↗

One joule output from a diode-array-pumped Nd:YAG laser with side-pumped rod geometry

Output of 1.25 J per pulse (1.064 micron) with an absolute optical efficiency of 28 percent and corresponding electrical efficiency of 10 percent was demonstrated in a diode-array-pumped Nd:YAG laser using a side-pumped rod geometry in a master-oscillator/power-amplifier configuration. In Q-switched operation, an output of 0.75 J in a 17-ns pulse was obtained. The fundamental laser output was frequency doubled in KTP with 60 percent conversion efficiency to obtain 0.45 J in a 16-ns pulse at 532 nm. The output beam had high spatial quality with pointing stability better than 40 microrad and a shot-to-shot pulse energy fluctuation of less than +/-3 percent.

Kasinski, Jeffrey J.↗

Two-Photon Entanglement and EPR Experiments Using Type-2 Spontaneous Parametric Down Conversion

Simultaneous entanglement in spin and space-time of a two-photon quantum state generated in type-2 spontaneous parametric down-conversion is demonstrated by the observation of quantum interference with 98% visibility in a simple beam-splitter (Hanburry Brown-Twiss) anticorrelation experiment. The nonlocal cancellation of two-photon probability amplitudes as a result of this double entanglement allows us to demonstrate two different types of Bell's inequality violations in one experimental setup.

Sergienko, A. V.↗

Bandwidth and threshold calculations for angle-tuned parametric oscillators.

The bandwidth of angle-tuned optical parametric oscillators, in some cases, is limited by the noncolinear interaction of the pump, signal, and idler beams, which results when the nonlinear material is rotated relative to the pump beam. To determine this bandwidth, a theoretical expression for the pump power threshold is derived in the near field limit taking into account double refraction for a noncolinear interaction. Angle tuning can be done by (1) rotating the crystal and mirrors as a unit, or by (2) rotating the crystal only. Expressions for determining the tuning rate and threshold increase for both tuning methods are derived.

Basu, R.↗

Method of and apparatus for double-exposure holographic interferometry

Double-exposure holographic interferometry is carried out using first and second lasers responsive to respective applied firing signals for producing respective pulsed output beams. An optical system is provided oriented such that the output beams of the lasers produce coinciding scene and reference beams. An initiator circuit generates and applies a firing signal to the first laser; and a timer/firing device responsive to the generation of a firing signal by the initiator circuit, generates and applies a firing signal to the second laser a predetermined period of time later.

Witherow, W. K.↗

A laboratory investigation of potential double layers

In a triple plasma device, the injection of electron current from the source chamber to the target chamber causes the formation of a potential double layer. At a low current density, the space charge of the injected current produces a virtual cathode-type potential double layer. This double layer is stable, and various wave instabilities are observed to associate with this double layer. As the current density is increased, the double layer becomes unstable, and a moving double layer results. As the current density is increased further, the enhanced ionization causes the neutralization of the space charge of the electron beam, and the beam plasma discharge is ignited.

Leung, Philip↗

A laboratory investigation of potential double layers

In a triple plasma device, the injection of electron current from the source chamber to the target chamber causes the formation of a potential double layer. At a low current density, the space charge of the injected current produces a virtual cathode-type potential double layer. This double layer is stable and various wave instabilities are observed to associate with this double layer. As the current density is increased, the double layer becomes unstable and a moving double layer results. As the current density is increased further, the enhanced ionization causes the neutralization of the space charge of the electron beam and the 'beam plasma discharge' is ignited.

Leung, Philip↗

Internal upconversion and doubling of an optical parametric oscillator to extend the tuning range.

Efficient extension of the tuning range of a 1.09-1.95-micron parametric oscillator to 0.435-0.975 microns by upconversion and doubling internally to the oscillator cavity is reported. Unlike previously studied external mixing, internal upconversion and doubling yielded uniform powers of 30 and 60 kW, respectively, over the entire extended tuning range with an unfocused 2-mm ruby laser pump beam of 750 kW.-

Campillo, A. J.↗

A polarizer for vacuum ultraviolet

An MgF2 double Rochon prism, useful as a polarizer or analyzer in wavelengths longer than 1300A is described. Measurements of MgF2 transmission and of polarizer angular beam deviation from 1150 to 2900A are presented. The prism is comprised of 2.25 mm, MgF2 depolarizers, optically contacted. At normal incidence, a 4% transmission gain was measured from 6000 to 2200A, compared with air spaced elements. One depolarizer was vibrated to 40 g from 20 to 3500 Hz without deterioration in optical contact. Transmissions below 1400A are not good. In thin samples, surface loss is twice absorption loss in the range 1150 to 1500A. Refraction indices and a computer ray trace were used in processing photographic beam divergence data. If care is taken to remedy scattering effects, the prism is an efficient on-axis polarizer in the 1300 to 3000A range.

Steinmetz, D. L.↗

Double passing the Kitt Peak 1-m Fourier transform spectrometer

Attention is given to a simple technique for performing the conversion of the Kitt Peak 1-m Fourier transform spectrometer's dual input/output optical configuration to a double pass configuration that improves spectral resolution by a factor of 2. The modification is made by placing a flat mirror in the output beam from each cat's eye, retroreflecting the beams back through the cat's eyes to the first beam splitter. A single detector is placed at the second input port, which then becomes the instrument's output.

Jennings, D. E.↗

Fanaroff-Riley I galaxies as the parent population of BL Lacertae objects. II - Optical constraints

The hypothesis is investigated that BL Lacertae objects are a subset of Fanaroff-Riley (FR) I galaxies dominated by beamed emission from a relativistic jet aligned with the line of sight. It is found that FR I galaxies, although of low radio luminosity, are bright optical galaxies. If the beaming hypothesis is correct, the optical luminosity function of BL Lac objects, including the effect of the host galaxy, can be approximated by a double power law with a given differential index. New estimates of the number counts of BL Lac objects are made which constrain their local number density for L(B) greater than about 6 x 10 to the 43rd ergs/s to be in the range 110-720/cu Gpc. The corresponding ratio between the total number densities of BL Lac objects and FR I galaxies is 0.003 to 0.02. This limits the Lorentz factor of the optical emission to the range 8-20, larger than that of the X-ray emitting plasma and roughly of the same order as the radio Lorentz factor.