Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

HINODE/EXTREME-ULTRAVIOLET IMAGING SPECTROMETER OBSERVATIONS OF THE TEMPERATURE STRUCTURE OF THE QUIET CORONA

We present a differential emission measure (DEM) analysis of the quiet solar corona on disk using data obtained by the Extreme-ultraviolet Imaging Spectrometer (EIS) on Hinode. We show that the expected quiet-Sun DEM distribution can be recovered from judiciously selected lines, and that their average intensities can be reproduced to within 30%. We present a subset of these selected lines spanning the temperature range log T = 5.6-6.4 K that can be used to derive the DEM distribution reliably, including a subset of iron lines that can be used to derive the DEM distribution free of the possibility of uncertainties in the elemental abundances. The subset can be used without the need for extensive measurements, and the observed intensities can be reproduced to within the estimated uncertainty in the pre-launch calibration of EIS. Furthermore, using this subset, we also demonstrate that the quiet coronal DEM distribution can be recovered on size scales down to the spatial resolution of the instrument (1'' pixels). The subset will therefore be useful for studies of small-scale spatial inhomogeneities in the coronal temperature structure, for example, in addition to studies requiring multiple DEM derivations in space or time. We apply the subset to 45 quiet-Sun data sets taken in the period 2007 January to April, and show that although the absolute magnitude of the coronal DEM may scale with the amount of released energy, the shape of the distribution is very similar up to at least log T approx 6.2 K in all cases. This result is consistent with the view that the shape of the quiet-Sun DEM is mainly a function of the radiating and conducting properties of the plasma and is fairly insensitive to the location and rate of energy deposition. This universal DEM may be sensitive to other factors such as loop geometry, flows, and the heating mechanism, but if so they cannot vary significantly from quiet-Sun region to region.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of response nonuniformity for the LHCb calorimeter module and the prototype of the CBM calorimeter module

A spatial nonuniformity of the response to high-energy muons is studied in the modules of the LHCb electromagnetic calorimeter and the prototype of the calorimeter module with lead plates and scintillator tiles 0.5 mm thick. The nonuniformity of the response of the inner LHCb modules to 50-GeV electrons is also measured. Software is developed for a thorough simulation of light collection in scintillator plates of a shashlik calorimeter. A model is elaborated to describe light transmission from the initial scintillation to the wavelength-shifting fiber with a subsequent reradiation and propagation of light over the fiber to the photodetector. The results of the simulation are in good agreement with data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LEPS2: the second Laser-Electron Photon facility at SPring-8

A new project to construct the second beamline for the laser-electron photon beam at SPring-8 (LEPS2) has started. Based on the LEPS experience, the project aims to improve the intensity of the photon beam and to expand the detector acceptance by adopting the BNL-E949 detector, which is a hermetic detector in a large 1 T solenoid magnet. The central region of tracking chambers will be upgraded for the LEPS2. A new LEPS2 experimental building has just been constructed outside the experimental hall of the storage ring. The present status of the development of a frozen-spin polarized HD target is also reported.

43 PARTICLE ACCELERATORS↗

Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon Irradiation Response on Ge and Al-Doped SiO{sub 2} Optical Fibres

Recently, research groups have reported a number of radiation effects on the applications of SiO{sub 2} optical fibres with possible use as dosimeter material because these optical fibre provide a good basis for medical radiation dosimetry. The objective of this study is to investigate the thermoluminescence response and fading characteristic for germanium and aluminium doped SiO{sub 2} optical fibres with photon irradiation. These optical fibres are placed in solid phantom and irradiated to 6 and 10 MV photon beam at dose ranging from 0.06 Gy to 0.24 Gy using Primus MLC 3339 linear accelerator at Hospital Sultan Ismail, Johor Bahru. In fading studies, the TL measurements were continued up to 14 days period. The optical fibres will produce glow curves whereby the information is then analyzed. Al and Ge-doped optical fibres have a linear dose-TL signal relationship that is proportionality between the TL signal and the doses. Comparison for TL response between different linear accelerator showed a good agreement because these optical fibres also have a linear dose-TL signal relationship even using different equipments.

36 MATERIALS SCIENCE↗

Low Background Counting At SNOLAB

It is a continuous and ongoing effort to maintain radioactivity in materials and in the environment surrounding most underground experiments at very low levels. These low levels are required so that experiments can achieve the required detection sensitivities for the detection of low-energy neutrinos, searches for dark matter and neutrinoless double-beta decay. SNOLAB has several facilities which are used to determine these low background levels in the materials and the underground environment. This proceedings will describe the SNOLAB High Purity Germanium Detector which has been in continuous use for the past five years and give results of many of the items that have been counted over that period. Brief descriptions of SNOLAB's alpha-beta and electrostatic counters will be given, and the radon levels at SNOLAB will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THz pulses from 4th generation X-ray light sources: Perspectives for fully synchronized THz pump X-ray probe experiments

In this paper the prospects of terahertz (THz) pulses generated at 4th generation X-ray light sources are presented on the example of recent results from a prototype set-up at the soft X-ray FEL FLASH. It is shown, that the THz pulses from the relativistic ultra short electron bunches have unique properties, that at FLASH are utilized for novel THz pump X-ray probe experiments with a robust few fs resolution. Based on these experiences it is discussed, how future facilities can benefit from implementation of similar or further improved instrumentation.

43 PARTICLE ACCELERATORS↗

A stretch/compress scheme for a high temporal resolution detector for the magnetic recoil spectrometer time (MRSt)

Here we present a time-resolved detector concept for the magnetic recoil spectrometer for time-resolved measurements of the NIF neutron spectrum. The measurement is challenging due to the time spreading of the recoil protons (or deuterons) as they transit an energy dispersing magnet system. Ions arrive at the focal plane of the magnetic spectrometer over an interval of tens of nanoseconds. We seek to measure the time-resolved neutron spectrum with 20 ps precision by manipulating an electron signal derived from the ions. A stretch-compress scheme is employed to remove transit time skewing while simultaneously reducing the bandwidth requirements for signal recording. Simulation results are presented along with design concepts for structures capable of establishing the required electromagnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Band-notched spiral antenna

A band-notched spiral antenna having one or more spiral arms extending from a radially inner end to a radially outer end for transmitting or receiving electromagnetic radiation over a frequency range, and one or more resonance structures positioned adjacent one or more segments of the spiral arm associated with a notch frequency band or bands of the frequency range so as to resonate and suppress the transmission or reception of electromagnetic radiation over said notch frequency band or bands.

47 OTHER INSTRUMENTATION↗

Nonproportional scintillation response of NaI:Tl to low energy x-ray photons and electrons

Nonproportional response of the scintillation yield of NaI:Tl was measured using highly monochromatic synchrotron irradiation ranging from 9-100 keV. Special attention is paid to the x-ray escape peaks. They provide us additional information about photon response in the range 0.9-12 keV. A rapid variation in the photon response curve is observed near the iodine K-electron binding energy. A dense sampling of data is performed around this energy and that data are used to apply a method, which we call K-dip spectroscopy. This method allows us to derive the electron response curve of NaI:Tl down to energies as low as 30 eV. A comparison of our data with data of others employing different methods is made. Advantages, limitations, and peculiarities of presented techniques and methods are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exotic Physics with ADMX

The Axion Dark Matter Experiment (ADMX) is an axion haloscope intended to search for local dark matter axions through their resonant conversion to microwave photons. As such, it is extremely sensitive to any particle that couples weakly to microwave photons. Preliminary results from a search for scalar chameleons and plans for a search for a two cavity search for hidden sector photons are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffractive Measurements at the LHC: Elastic and Inelastic Soft Diffraction

A short review of four topics was presented: (1) Photon bremsstrahlung in elastic proton-proton scattering, (2) Low mass Single Diffraction (SD), (3) Low mass Central Exclusive Diffraction (CED), and (4) Event classification of the pp interactions at the LHC. This article summarizes topic (1).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE HIGH-ENERGY EMISSION OF THE CRAB NEBULA FROM 20 keV TO 6 MeV WITH INTEGRAL SPI

The SPI spectrometer aboard the International Gamma-Ray Astrophysics Laboratory mission regularly observes the Crab Nebula since 2003. We report on observations distributed over 5.5 years and investigate the variability of the intensity and spectral shape of this remarkable source in the hard X-rays domain up to a few MeV. While single power-law models give a good description in the X-ray domain (mean photon index approx 2.05) and MeV domain (photon index approx 2.23), crucial information is contained in the evolution of the slope with energy between these two values. This study has been carried out through individual observations and long duration (approx 400 ks) averaged spectra. The stability of the emission is remarkable and excludes a single power-law model. The slopes measured below and above 100 keV agree perfectly with the last values reported in the X-ray and MeV regions, respectively, but without indication of a localized break point. This suggests a gradual softening in the emission around 100 keV and thus a continuous evolution rather than an actual change in the mechanism parameters. In the MeV region, no significant deviation from the proposed power-law model is visible up to 5-6 MeV. Finally, we take advantage of the spectroscopic capability of the instrument to seek for previously reported spectral features in the covered energy range with negative results for any significant cyclotron or annihilation emission on 400 ks timescales. Beyond the scientific results, the performance and reliability of the SPI instrument is explicitly demonstrated, with some details about the most appropriate analysis method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beam Asymmetries in {pi}{sup 0} Photoproduction on the Proton

Polarization observables, such as the beam asymmetry {Sigma}, are vital to the study of the many N* and {Delta} resonances that decay to the p{pi}{sup 0} final state. Beam asymmetries in {pi}{sup 0} photoproduction off the proton have been determined using the Crystal Barrel CsI(Tl) calorimeter at ELSA, University of Bonn in Germany, in the energy range E{gamma} = 920 to 1680 MeV by analyzing the neutral decay mode {pi}{sup 0{yields}{gamma}{gamma}}. In this experiment, the BaF{sub 2} spectrometer TAPS was placed in the forward direction increasing the solid angle coverage to nearly 4{pi} and serving as a fast trigger. For the first time, these measurements include the most forward angles in {theta}{sub {pi}}{sup 0c{center_dot}m}. Additionally, this analysis provides new data points in the energy range E{gamma} = 1510 to 1680 MeV where few measurements have previously been made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Weak lensing effects in the measurement of the dark energy equation of state with LISA

The Laser Interferometer Space Antenna's (LISA's) observation of supermassive binary black holes (SMBBH) could provide a new tool for precision cosmography. Inclusion of subdominant signal harmonics in the inspiral signal allows for high-accuracy sky localization, dramatically improving the chances of finding the host galaxy and obtaining its redshift. A SMBBH merger can potentially have component masses from a wide range (10{sup 5}-10{sup 8}M{sub {center_dot}}) over which parameter accuracies vary considerably. We perform an in-depth study in order to understand (i) what fraction of possible SMBBH mergers allow for sky localization, depending on the parameters of the source, and (ii) how accurately w can be measured when the host galaxy can be identified. We also investigate how accuracies on all parameters improve when a knowledge of the sky position can be folded into the estimation of errors. We find that w can be measured to within a few percent in most cases, if the only error in measuring the luminosity distance is due to LISA's instrumental noise and the confusion background from Galactic binaries. However, weak lensing-induced errors will severely degrade the accuracy with which w can be obtained, emphasizing that methods to mitigate weak lensing effects would be required to take advantage of LISA's full potential.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision measurements of K{sup {+-}} {yields} {pi}{sup {+-}}{pi}{sup 0}{gamma} decay at NA48/2 and search for CP violation

The direct emission (DE) and interference (INT) terms of the radiative decay K{sup {+-}} {yields} {pi}{sup {+-}}{pi}{sup 0}{gamma} have been measured by the NA48/2 experiment at CERN SPS. About 6 10{sup 5} K{sup {+-}} {yields} {pi}{sup {+-}}{pi}{sup 0}{gamma} decays have been selected from data collected during 2003 and 2004. The relative amounts of DE and INT with respect to the dominant Inner Bremsstrahlung (IB) contribution have been measured in the range 0<T{sub {pi}}{sup *}<80 MeV, where T{sub {pi}}{sup *} is the kinetic energy of the charged pion in the kaon rest frame, obtaining: Frac(DE) = (3.32 {+-}0.15{sub stat}{+-}0.14{sub syst})10{sup -2}, Frac(INT) = (-2.35 {+-}0.35{sub stat}{+-}0.39{sub syst}) 10{sup -2}. This is the first observation of an interference term in K{sup {+-}} {yields} {pi}{sup {+-}}{pi}{sup 0}{gamma} decays. From this measurement the DE normalized electric and magnetic amplitudes are derived: X{sub E} = (-24 {+-}6) GeV{sup -4}, X{sub M} = (254 {+-} 9) GeV{sup -4}.In addition, the CP violating asymmetry in the K{sup +} and K- branching ratios for this channel has been determined to be less than 1.5 10{sup -3} at 90% confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗