Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRONIC GUIDANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Dynamic evolution of ultracold electron beams from nanostructured cathodes

Dynamic Coulomb expansion of dense, nonuniform particle beamlets can lead to causticlike formations in the charge density profile of the resultant beam. Such features only occur for cold beams where thermal diffusion of the particles is minimized. These phenomena have been observed experimentally for select cases with ion beams but not yet for electron beams as the electron dynamics occur over far faster timescales. We simulate the interaction of electron bunches while varying the initial transverse temperature and density profiles to determine the thresholds that characterize this pattern formation. Furthermore, we extend the simulations to geometric arrangements that are more pertinent to the nanotip cathode application and consider the effects of asymmetries and the impact of a low-density halo on the overall process. The simulations are conducted using a previously documented high-fidelity algorithm for collisional particle dynamics. These studies identify the temperature and density thresholds required for caustic formation and provide guidance for optimizing the design of nanoscale structured cathodes. We also demonstrate that the correlation between the final density patterns and the underlying beam parameters enables a virtual diagnostic tool for measuring ultralow emittance beams solely based on a transverse charge density profile.

43 PARTICLE ACCELERATORS↗

SU-D-BRD-01: An Automated Physics Weekly Chart Checking System Supporting ARIA

Purpose: A software tool was developed in this study to perform automatic weekly physics chart check on the patient data in ARIA. The tool accesses the electronic patient data directly from ARIA server and checks the accuracy of treatment deliveries, and generates reports which summarize the delivery history and highlight the errors. Methods: The tool has four modules. 1) The database interface is designed to directly access treatment delivery data from the ARIA database before reorganizing the data into the patient chart tree (PCT). 2) PCT is a core data structure designed to store and organize the data in logical hierarchies, and to be passed among functions. 3) The treatment data check module analyzes the organized data in PCT and stores the checking results into PCT. 4) Report generation module generates reports containing the treatment delivery summary, chart checking results and plots of daily treatment setup parameters (couch table positions, shifts of image guidance). The errors that are found by the tool are highlighted with colors. Results: The weekly check tool has been implemented in MATLAB and clinically tested at two major cancer centers. Javascript, cascading style sheets (CSS) and dynamic HTML were employed to create the user-interactive reports. It takes 0.06 second to search the delivery records of one beam with PCT and compare the delivery records with beam plan. The reports, saved in the HTML files on shared network folder, can be accessed by web browser on computers and mobile devices. Conclusion: The presented weekly check tool is useful to check the electronic patient treatment data in Varian ARIA system. It could be more efficient and reliable than the manually check by physicists. The work was partially supported by a research grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

SU-E-T-433: Calibration Accuracy in Mailed High-Resolution 3D Dosimetry Service for SRS/SBRT QA

Purpose: SRS/SBRT combines hypofractionation with excellent dose distributions. However, extremely steep gradients across the target along with dose escalation, if not administered accurately, may lead to serious complications, recurrences, or even fatalities. Existing commercial QA products either lack adequate spatial resolution or the 3D aspect. By contrast, the new CrystalBall™ mailed high-resolution 3D dosimetry service removes the above limitations while reducing the overall workload on medical physics staff. The exposed dosimeters, which change optical density in proportion to local dose, are sent back to the manufacturer (MGS Research Inc., Madison, CT) for sub-millimeter-resolution laser-CT scanning and QA data analysis. QA report is returned electronically within 24 hours. The purpose of this study was to evaluate the dose calibration accuracy in this system. Methods: Two spherical CrystalBall™ polymer gel dosimeters from the same batch, 166 mm diameter, with embedded 3D image registration markers, were mounted in a special phantom designed for reproducible positioning. For full end to end testing, the optical guidance array was mounted onto the phantom and a CT was taken. Two separate Rapid Arc SRS plans were designed. Varian Medical Systems optical guidance system was used to position the phantom and the SRS treatment plans were delivered to the two spheres on Varian's Trilogy Accelerator. Exposed dosimeters were mailed back to the manufacturer for laser CT scanning and analysis. Results: For each plan, 3D gamma passing rate was 100% for 2%/2mm distance-to-agreement criteria above 50% isodose level. The two calibration curves, generated using volumetric dose and optical density data, showed excellent mutual agreement (max difference 2.2%, median difference 0.75%). Conclusion: The clinical utility of new CrystalBall™ mailed QA service for SRS/SBRT and high accuracy of dose calibration have been validated. The workflow associated with the use of the CrystalBall™ in clinical setting was found to be minimal. The presenting author is the founder of and has an ownership in MGS Research Inc which manufactures the CrystalBall system for 3D dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helicopter Flight Test of 3-D Imaging Flash LIDAR Technology for Safe, Autonomous, and Precise Planetary Landing

Two flash lidars, integrated from a number of cutting-edge components from industry and NASA, are lab characterized and flight tested for determination of maximum operational range under the Autonomous Landing and Hazard Avoidance Technology (ALHAT) project (in its fourth development and field test cycle) which is seeking to develop a guidance, navigation, and control (GN&C) and sensing system based on lidar technology capable of enabling safe, precise crewed or robotic landings in challenging terrain on planetary bodies under any ambient lighting conditions. The flash lidars incorporate pioneering 3-D imaging cameras based on Indium-Gallium-Arsenide Avalanche Photo Diode (InGaAs APD) and novel micro-electronic technology for a 128 x 128 pixel array operating at 30 Hz, high pulse-energy 1.06 micrometer Nd:YAG lasers, and high performance transmitter and receiver fixed and zoom optics. The two flash lidars are characterized on the NASA-Langley Research Center (LaRC) Sensor Test Range, integrated with other portions of the ALHAT GN&C system from partner organizations into an instrument pod at NASA-JPL, integrated onto an Erickson Aircrane Helicopter at NASA-Dryden, and flight tested at the Edwards AFB Rogers dry lakebed over a field of human-made geometric hazards during the summer of 2010. Results show that the maximum operational range goal of 1 km is met and exceeded up to a value of 1.2 km. In addition, calibrated 3-D images of several hazards are acquired in real-time for later reconstruction into Digital Elevation Maps (DEM's).

Roback, Vincent↗

Electrocatalytic Effects of Au Nanoclusters in its Electrochemiluminescence Enhanced by Coreactant Tertiary Amines

Abstract Atomically precise metal nanoclusters are increasingly exploited in electrocatalysis such as water electrolysis and CO 2 reduction. The catalytic effects are generally evaluated by conventional electrochemical methods or end‐product analysis. Herein, near infrared electrochemiluminescence (ECL) of the nanoclusters is introduced as a new signaling mechanism to complement classical voltammetric analysis for elucidating essential electrocatalytic parameters. Coreactant ECL from an aqueous soluble Au 22 nanocluster (NCs) enhanced by a common pH buffer materials 4‐(2‐hydroxyethyl)‐1‐piperazineethanesulfonic acid (HEPES) and by a piperazine drug hydroxyzine (HDZ) is studied under oxidative reduction pathways. Foot of the wave analysis on voltametric features and the kinetics profiles in potential‐step experiments are studied in different nanocluster and coreactant concentrations. Benchmark parameters such as rate constants are determined under EC (Electron‐transfer‐Chemical‐reaction) mechanism as feasibility validations. Because the luminescence properties of AuNCs are sensitive to the surface ligands or adsorbents, ECL is proposed as a new signal readout for operando studies providing insights for governing reaction mechanism and kinetics during catalytic reactions. Retrospectively, mechanistic understanding of the complex multi‐step reactions during ECL generation can provide guidance for the evaluation and optimization of ECL property for better quantitative applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Composition and Local Environment on CO 2 Adsorption on Nickel and Magnesium Oxide Solid Solutions

CO 2 adsorption energies on the (100) surfaces of a nickel oxide doped with Mg, magnesium oxide doped with Ni, and their 50:50 solid solution were calculated using density functional theory. The composition and atomic arrangement of the adsorption site was varied to understand how the local environment affects CO 2 adsorption and the basicity of the surfaces at the atomic level. The dispersive and electronic contributions to the adsorption energies were quantified, and the results indicate that the variation of the adsorption energy with adsorption site configuration and metal composition is dominated by electronic interactions. Interestingly, for magnesium oxide doped with nickel, a single substitution can create stronger CO 2 binding sites, which implies stronger basic sites, even though nickel oxide is less basic than magnesium oxide. The effect of double substitution at the binding site can be reasonably approximated by summing the effects of single substitutions. Furthermore, this work provides guidance for the preparation of metal oxides with tailored Lewis basicity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design considerations for the free-electron laser with the self-seeding and current-enhanced SASE

Cost of the facility producing x-rays using free-electron lasers (FELs) is largely defined by the electron beam energy E 0 and by the availability of the undulators with a certain period that will support production of photons in the range of photon energies between ℏω 1 and ℏω 2 corresponding to the wavelengths λ 1 and λ 2 . Here we first consider a trade-off of various parameters that could provide initial guidance in the cost optimization of the FEL covering the range of photon energies from ℏω 1 = 4 keV to ℏω 2 = 5 keV. In this analysis we also compare helical and planar undulators. After selecting a preferred set of parameters, we proceed with a preliminary design of the FEL that employs self-seeding and enhanced SASE techniques.

Zholents, Alexander↗

Reliability history of the Apollo guidance computer

The Apollo guidance computer was designed to provide the computation necessary for guidance, navigation and control of the command module and the lunar landing module of the Apollo spacecraft. The computer was designed using the technology of the early 1960's and the production was completed by 1969. During the development, production, and operational phase of the program, the computer has accumulated a very interesting history which is valuable for evaluating the technology, production methods, system integration, and the reliability of the hardware. The operational experience in the Apollo guidance systems includes 17 computers which flew missions and another 26 flight type computers which are still in various phases of prelaunch activity including storage, system checkout, prelaunch spacecraft checkout, etc. These computers were manufactured and maintained under very strict quality control procedures with requirements for reporting and analyzing all indications of failure. Probably no other computer or electronic equipment with equivalent complexity has been as well documented and monitored. Since it has demonstrated a unique reliability history, it is important to evaluate the techniques and methods which have contributed to the high reliability of this computer.

Hall, E. C.↗

Novel position sensor technologies for microaccelerometers

An important new approach for vehicle guidance and control is based on the use of compact, low-mass, low-cost sensors integrated with the vehicle structure. Many advantages of this approach lead to new capabilities. However, the development of compact guidance and control sensors leads to a variety of fundamental physical problems associated with sensor sensitivity and noise. For example, as sensor size is reduced, it becomes necessary to improve the sensitivity of the sensor signal detection mechanism. These challenges to sensor development will be described. Recent developments at JPL, based on new position sensor principles such as electron tunneling, have produced a series of novel, ultra-high sensitivity micro-sensors and micro-instruments. Included among the applications demonstrated, are a high sensitivity micro-accelerometer and micro-seismometer. In this paper, the fundamental limits of conventional position sensors will be discussed and a new position sensor for advanced accelerometers will be described.

Vanzandt, T. R.↗

Optical Interference for the Guidance of Cryogenic Focused Ion Beam Milling Beyond the Axial Diffraction Limit

Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labelled structures with accuracy beyond the diffraction limit. We demonstrate the approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of water. Here, we then apply the approach to capture virions inside host cells. Successful targeting is confirmed by cryogenic electron tomography revealing clusters of virions in intracellular vesicles.

Sica, Anthony V. [SLAC National Accelerator Labora↗

Design principles for lifelong learning AI accelerators

Lifelong learning-an agent's ability to learn throughout its lifetime-is a hallmark of biological learning systems and a central challenge for artificial intelligence (AI). The development of lifelong learning algorithms could lead to a range of novel AI applications, but this will also require the development of appropriate hardware accelerators, particularly if the models are to be deployed on edge platforms, which have strict size, weight and power constraints. Here we explore the design of lifelong learning AI accelerators that are intended for deployment in untethered environments. We identify key desirable capabilities for lifelong learning accelerators and highlight metrics to evaluate such accelerators. We then discuss current edge AI accelerators and explore the future design of lifelong learning accelerators, considering the role that different emerging technologies could play. The Perspective explores the future design of lifelong learning artificial intelligence (AI) accelerators that are intended for deployment in untethered environments, identifying key desirable capabilities for such edge AI accelerators and guidance on metrics to evaluate them.

42 ENGINEERING↗

Universal signal scaling in microwave impedance microscopy

Microwave impedance microscopy (MIM) is an emerging scanning probe technique that measures the local complex dielectric function using near-field microwave. Although it has made significant impacts in diverse fields, a systematic, quantitative understanding of the signal's dependence on various important design parameters is lacking. Here, we show that for a wide range of MIM implementations, given a complex tip-sample admittance change ΔΥ, the MIM signal—the amplified change in the reflected microwave amplitude—is –G · ΔΥ/2Υ 0 · η 2 · V in , where η is the ratio of the microwave voltage at the probe to the incident microwave amplitude, Y o is the system admittance, and G is the total voltage gain. For linear circuits, η is determined by the circuit design and does not depend on V in . We show that the maximum achievable signal for different designs scales with η 2 or η when limited by input power or sample perturbation, respectively. Furthermore, this universal scaling provides guidance on diverse design goals, including maximizing narrow-band signal for imaging and balancing bandwidth and signal strength for spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-Time Quantum Dynamics of Long-Range Electronic Excitation Transfer in Plasmonic Nanoantennas

Using large-scale, real-time, quantum dynamics calculations, we present a detailed analysis of electronic excitation transfer (EET) mechanisms in a multiparticle plasmonic nanoantenna system. Specifically, we utilize real-time, time-dependent, density functional tight binding (RT-TDDFTB) to provide a quantum-mechanical description (at an electronic/atomistic level of detail) for characterizing and analyzing these systems, without recourse to classical approximations. We also demonstrate highly long-range electronic couplings in these complex systems and find that the range of these couplings is more than twice the conventional cutoff limit considered by Förster resonance energy transfer (FRET)-based approaches. Furthermore, we attribute these unusually long-ranged electronic couplings to the coherent oscillations of conduction electrons in plasmonic nanoparticles. This long-range nature of plasmonic interactions has important ramifications for EET; in particular, we show that the commonly used “nearest-neighbor” FRET model is inadequate for accurately characterizing EET even in simple plasmonic antenna systems. These findings provide a real-time, quantum-mechanical perspective for understanding EET mechanisms and provide guidance in enhancing plasmonic properties in artificial light-harvesting systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine learning guided search for energetically favorable metal borocarbide ternary compounds

In this work, we employ machine-learning (ML) combined with first principles calculations to efficiently search for the energetically favorable metal borocarbide (M-B-C) ternary compounds with M being the group 1–3 metal elements. Using a crystal graph convolutional neural network (CGCNN) ML approach followed by first-principles calculations, we predicted 47 energetically favorable stable and metastable ternary Na-B-C, Ca-B-C, and La-B-C ternary compounds with their decomposition energy (E d ) below or within 100 meV/atom from the currently known convex hulls. Phonon spectra and electronic structures of the 14 energetically favorable stable structures are also investigated by first-principles calculations. By substituting the metal atoms in the 29 energetically favorable non-equivalent template structures of Na (Ca, La)-B-C with other group 1–3 elements in the periodic table, we further obtain 22 stable structures and 52 metastable structures (E d ≤100 meV/atom with respect to the known convex hulls) for Li-B-C, K-B-C, Rb-B-C, Mg-B-C, Sr-B-C, Ba-B-C, Sc-B-C and Y-B-C ternary compounds. New convex hulls including our newly predicted stable ternary structures and the known stable structures are constructed for the M-B-C systems. The results obtained by our ML guided first-principles calculations enrich our knowledge in the structure and energy landscape of metal borocarbide ternary compounds and provide useful guidance for further experimental synthesis and discovery.

36 MATERIALS SCIENCE↗

Ab-initio Cu alloy design for high-gradient accelerating structures

Operation of normal conducting accelerator structures at high accelerating gradients is beneficial for many accelerator applications in basic science, industry, medicine, and National Security. RF breakdown is the major factor that limits the achievable accelerating gradients. Previous experiments on copper (Cu) have demonstrated that RF breakdown probability can be significantly decreased by hardening the material and alloying Cu with solutes such as silver (Ag). In this paper, we propose a figure-of-merit (FOM) that characterizes the ability of Cu alloys to withstand high-gradients. The FOM represents a trade-off between hardening through solid solution strengthening and the additional thermal stress induced by incremental RF pulse heating resulting from changes in electronic properties induced by alloying. We performed high-throughput ab initio calculations and computed the FOM for a large number of binary Cu alloys. Several promising candidate alloys for high-gradient accelerating structures were identified, such as CuAg, CuCd, CuHg, CuAu, CuIn, and CuMg. CuAg alloys have previously exhibited low RF breakdown rates in experiments. The results provide guidance for selecting alloys for the future high-gradient normal conducting accelerating structures operating at very high gradients.

36 MATERIALS SCIENCE↗

Dose rates near the Service Buildings for Al, Cu, Fe and Pb targets

Fluka simulations were performed to model fault conditions that result in the electron beam hitting different materials found in the storage ring (SR), namely aluminum in beam pipes, copper in magnet coils, iron in magnet yokes and lead in local shields. The primary goal of the simulations was to determine dose distributions outside the bulk shielding due to beam losses for different fault conditions. These predicted doses can be used to provide guidance regarding the need for additional shielding or administrative safeguards. A secondary goal was to compare the simulated dose at three different locations with the dose obtained from analytical calculations using the thick target approximation. The analytical calculations are quick and easy and do not require detailed modeling of the geometry. If these calculations can indeed provide reasonably accurate estimates of the dose then they can be used instead of the detailed FLUKA simulations which require more time, effort and computational resources. However the assumptions embedded in the analytical methods result in the maximum possible yield of secondary particles and will therefore overestimate the radiation dose and the radiation shielding required.

36 MATERIALS SCIENCE↗

Autonomous control of roving vehicles for unmanned exploration of the planets

The guidance of an autonomous rover for unmanned planetary exploration using a short range (0.5 - 3.0 meter) hazard detection system was studied. Experimental data derived from a one laser/one detector system were used in the development of improved algorithms for the guidance of the rover. The new algorithms which account for the dynamic characteristics of the Rensselaer rover can be applied to other rover concepts provided that the rover dynamic parameters are modified appropriately. The new algorithms will also be applicable to the advanced scanning system. The design of an elevation scanning laser/multisensor hazard detection system was completed. All mechanical and electronic hardware components with the exception of the sensor optics and electronic components were constructed and tested.

Yerazunis, S. W.↗

Evolution of miniature detectors and focal plane arrays for infrared sensors

Sensors that are sensitive in the infrared spectral region have been under continuous development since the WW2 era. A quest for the military advantage of 'seeing in the dark' has pushed thermal imaging technology toward high spatial and temporal resolution for night vision equipment, fire control, search track, and seeker 'homing' guidance sensing devices. Similarly, scientific applications have pushed spectral resolution for chemical analysis, remote sensing of earth resources, and astronomical exploration applications. As a result of these developments, focal plane arrays (FPA) are now available with sufficient sensitivity for both high spatial and narrow bandwidth spectral resolution imaging over large fields of view. Such devices combined with emerging opto-electronic developments in integrated FPA data processing techniques can yield miniature sensors capable of imaging reflected sunlight in the near IR and emitted thermal energy in the Mid-wave (MWIR) and longwave (LWIR) IR spectral regions. Robotic space sensors equipped with advanced versions of these FPA's will provide high resolution 'pictures' of their surroundings, perform remote analysis of solid, liquid, and gas matter, or selectively look for 'signatures' of specific objects. Evolutionary trends and projections of future low power micro detector FPA developments for day/night operation or use in adverse viewing conditions are presented in the following test.

Watts, Louis A.↗