Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPECTATION VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Weak scale as a trigger

Does the value of the Higgs mass parameter affect the expectation value of local operators in the Standard Model? For essentially all local operators the answer to this question is "no", and this is one of the avatars of the hierarchy problem: nothing is "triggered" when the Higgs mass parameter crosses zero. In this letter, we explore settings in which Higgs mass parameters $can$ act as a "trigger" for some local operators ${\cal O}_T$. In the Standard Model, this happens for ${\cal O}_T = {\rm Tr} (G \tilde G)$. We also introduce a "type-0" two Higgs doublet model, with a $Z_4$ symmetry, for which ${\cal O}_T = H_1 H_2$ is triggered by the Higgs masses, demanding the existence of new Higgs states necessarily comparable to or lighter than the weak scale, with no wiggle room to decouple them whatsoever. Surprisingly, this model is not yet entirely excluded by collider searches, and will be incisively probed by the high-luminosity run of the LHC, as well as future Higgs factories. We also discuss a possibility for using this trigger to explain the origin of the weak scale, invoking a landscape of extremely light, weakly interacting scalars $\phi_i$, with a coupling to ${\cal O}_T$ needed to make it possible to find vacua with small enough cosmological constant. The weak scale trigger links the tuning of the Higgs mass to that of the cosmological constant, while coherent oscillations of the $\phi_i$ can constitute dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Taming the Goldstone contributions to the effective potential

The standard perturbative effective potential suffers from two related problems of principle involving the field-dependent Goldstone boson squared mass, G. First, in general G can be negative, and it actually is negative in the Standard Model; this leads to imaginary contributions to the effective potential that are not associated with a physical instability, and therefore spurious. Second, in the limit that G approaches zero, the effective potential minimization condition is logarithmically divergent already at two-loop order, and has increasingly severe power-law singularities at higher loop orders. I resolve both issues by resumming the Goldstone boson contributions to the effective potential. For the resulting resummed effective potential, the minimum value and the minimization condition that gives the vacuum expectation value are obtained in forms that do not involve G at all.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wave-function functionals

We extend our prior work on the construction of variational wave functions {psi} that are functionals of functions {chi}:{psi}={psi}[{chi}] rather than simply being functions. In this manner, the space of variations is expanded over those of traditional variational wave functions. In this article we perform the constrained search over the functions {chi} chosen such that the functional {psi}[{chi}] satisfies simultaneously the constraints of normalization and the exact expectation value of an arbitrary single- or two-particle Hermitian operator, while also leading to a rigorous upper bound to the energy. As such the wave function functional is accurate not only in the region of space in which the principal contributions to the energy arise but also in the other region of the space represented by the Hermitian operator. To demonstrate the efficacy of these ideas, we apply such a constrained search to the ground state of the negative ion of atomic hydrogen H{sup -}, the helium atom He, and its positive ions Li{sup +} and Be{sup 2+}. The operators W whose expectations are obtained exactly are the sum of the single-particle operators W={Sigma}{sub i}r{sub i}{sup n},n=-2,-1,1,2, W={Sigma}{sub i{delta}}(r{sub i}), W=-(1/2){Sigma}{sub i{nabla}i}{sup 2}, and the two-particle operators W={Sigma}{sub n}u{sup n},n=-2,-1,1,2, where u=|r{sub i}-r{sub j}|. Comparisons with the method of Lagrangian multipliers and of other constructions of wave-function functionals are made. Finally, we present further insights into the construction of wave-function functionals by studying a previously proposed construction of functionals {psi}[{chi}] that lead to the exact expectation of arbitrary Hermitian operators. We discover that analogous to the solutions of the Schroedinger equation, there exist {psi}[{chi}] that are unphysical in that they lead to singular values for the expectations. We also explain the origin of the singularity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quasi 2D Ultrahigh Carrier Density in a Complex Oxide Broken Gap Heterojunction

Two-dimensional (2D) ultra-high carrier densities at complex oxide interfaces are of considerable current research interest for novel plasmonic and high charge-gain devices. However, the highest 2D electron density obtained in oxide heterostructures is thus far limited to 3×1014 cm-2 (½ electron/unit cell/interface) at GdTiO3/SrTiO3 interfaces, and is typically an order of magnitude lower at LaAlO3/SrTiO3 interfaces. Here we show that carrier densities much higher than 3×1014 cm-2 can be achieved via band engineering. Transport measurements for 3 nm SrTiO3/t u.c. NdTiO3/3 nm SrTiO3/LSAT (001) show that charge transfer significantly in excess of the value expected from the polar discontinuity model occurs for higher t values. The carrier density remains unchanged, and equivalent to ½ electron/unit cell/interface for t < 6 unit cells. However, above a critical NdTiO3 thickness of 6 u.c., electrons from the valence band of NdTiO3 spill over into the SrTiO3 conduction band as a natural consequence of the band alignment. An atomistic model consistent with first-principle calculations and experimental results is proposed for the charge transfer mechanisms. These results may provide an exceptional route to the realization of the room-temperature oxide electronics.

Environmental Molecular Sciences Laboratory↗

Kinetics of D/H isotope fractionation between molecular hydrogen and water

At equilibrium, the D/H isotope fractionation factor between H 2 and H 2 O (α H 2 O-H 2 (eq) ) is a sensitive indicator of temperature, and has been used as a geothermometer for natural springs and gas discharges. However, δD H 2 measured in spring waters may underestimate subsurface temperatures of origin due to partial isotopic re-equilibration during ascent and cooling. In this work, we present new experimental data on the kinetics of D–H exchange for H 2 dissolved in liquid water at temperatures below 100 °C. Comparing these results with published exchange rates obtained from gas phase experiments (100–400 °C), we derive a consistent activation energy of 52 kJ/mol, and the following rate expressions; ln k =9.186 - 6298/ T and k 1 = 9764.61[H 2 O] e-6298/ T where T is absolute temperature (K), k is the universal rate constant ([L/mol]/hr), and k 1 is a pseudo-first-order constant (hr -1 ) applicable to water-dominated terrestrial systems by constraining [H 2 O] as the density of H 2 O (in mol/L) at the P-T of interest. The density-dependent rate constant accounts for the kinetic disparity of D–H exchange with H 2 when dissolved in liquid H 2 O relative to a gas/steam phase, exemplifed by 1/ k 1 at 100 °C of ~2 days in liquid, versus ~7 yrs in saturated steam. This difference may explain the high variability of δDH 2 observed in fumarolic gases. Fluids convecting in the crust frequently reach T > 225 °C, where isotopic equilibrium is rapidly attained (<1 hr). We compare fractionation factors measured in natural fluids (α OBS ) with values expected for equilibrium at the T of acquisition. Where these values differ, we use kinetic models to estimate cooling rates during upward advection that account for the observed disequilibrium. Models fit to fluids from Yellowstone Park and the Lost City (deep-sea) vent field, both recovered at ~90 °C, require respective transit times of ~7 hrs and ~11 days between higher temperature reaction zones and the surface. Using estimates of subsurface depths of origin, however, suggests similar mean fluid flow rates (10 s of meters/hr). Additional complications must be considered when interpreting the δDH 2 of lower-temperature effluent. When applied to data from deep-sea hydrothermal systems, our kinetic models indicate microbial catalysis accelerates D–H exchange once fluids cool below ~60 °C. The H 2 measured in both continental alkaline springs and fracture fluids from Precambrian shield rock is likely produced at T < 100 °C, through processes such as serpentinization. In these settings, δDH 2 values appear closer to equilibrium with H 2 O than those from geothermal systems. Considering kinetic isotope effects may yield H 2 that is out of equilibrium when generated at lower temperatures, we calculate maximum (isothermal) times to apparent isotopic equilibrium of 1.3 yrs at 50 °C, 9 yrs at 25 °C, and 35 yrs at 10 °C. A similar calculation applied to Antarctic brines (-13 °C), where measured δDH 2 is far from equilibrium, yields ~350 yrs. This time is shorter than the fluids have been isolated (2.8 ka), suggesting kinetic isotope effects associated with H 2 destruction or loss via diffusion may also be possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search for the Higgs boson decay to a Z boson and a photon in pp collisions at $\sqrt{s}$ = 13 TeV and 13.6 TeV with the ATLAS detector

A search for the Higgs boson decay to a Z boson and a photon in the ℓℓγ (ℓ = 𝑒,𝜇) final state is performed using pp collisions at $\sqrt{s}$ = 13.6 TeV recorded with the ATLAS detector at the Large Hadron Collider during 2022–2024, corresponding to an integrated luminosity of 165 fb−1. The signal yield, normalised to the Standard Model prediction, is measured to be 𝜇 = 0.9$^{+0.7}_{−0.6}$, compatible with the expected value of 𝜇 = 1.0 ± 0.7. This corresponds to an observed (expected) signal significance of 1.4 (1.5) standard deviations under the background-only hypothesis. This result is combined with that of a similar search performed with 140 fb −1 of $\sqrt{s}$ = 13 TeV pp collisions to provide the best expected sensitivity to date to this rare decay, namely an observed (expected) signal strength of 𝜇 = 1.3$^{+0.6}_{−0.5}$ (𝜇 = 1.0$^{+0.6}_{−0.5}$), corresponding to an observed (expected) significance of 2.5 (1.9) standard deviations. The measurement is consistent with the Standard Model expectation.

Aad, G. (ORCID:0000000266654934)↗

Time Evolution of Correlation Functions in Quantum Many-Body Systems

We give rigorous analytical results on the temporal behavior of two-point correlation functions—also known as dynamical response functions or Green’s functions—in closed many-body quantum systems. We show that in a large class of translation-invariant models the correlation functions factorize at late times $\langle$A ( t ) B$\rangle$ β → $\langle$ A$\rangle$ β $\langle$ B$\rangle$ β , thus proving that dissipation emerges out of the unitary dynamics of the system. We also show that for systems with a generic spectrum the fluctuations around this late-time value are bounded by the purity of the thermal ensemble, which generally decays exponentially with system size. For autocorrelation functions we provide an upper bound on the timescale at which they reach the factorized late time value. Remarkably, this bound is only a function of local expectation values and does not increase with system size. We give numerical examples that show that this bound is a good estimate in nonintegrable models, and argue that the timescale that appears can be understood in terms of an emergent fluctuation-dissipation theorem. Our study extends to further classes of two point functions such as the symmetrized ones and the Kubo function that appears in linear response theory, for which we give analogous results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BINARY CENTRAL STARS OF PLANETARY NEBULAE DISCOVERED THROUGH PHOTOMETRIC VARIABILITY. V. THE CENTRAL STARS OF HaTr 7 AND ESO 330-9

We find the central stars (CSs) of the planetary nebulae (PNe) HaTr 7 and ESO 330-9 to be close-binary systems. Both have orbital periods of less than half a day and contain an irradiated cool companion to the hot CS. We provide light curves, spectra, radial velocity curves, orbital periods, and binary modeling results for both systems. The binary modeling leads to system parameters, or ranges of allowed parameters for each system. We find that for the CS of HaTr 7 we need to use limb-darkening values for the cool companion that are different than the expected values for an isolated star. We also fit the CS spectrum to determine logg and temperature values independent of the binary modeling. For ESO 330-9 we find that based on our binary modeling, the hot CS is most likely a post-red giant branch (RGB) star with a mass of around 0.4 M{sub ⊙}. We discuss our derived stellar and nebular parameters in the broader context of close-binary CSs and their surrounding planetary nebulae (PNe). We also discuss the present status of known or suspected post-RGB stars in PNe.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of absorbed dose in water at the reference point D(r{sub 0},{theta}{sub 0}) for an {sup 192}Ir HDR brachytherapy source using a Fricke system

A ring-shaped Fricke device was developed to measure the absolute dose on the transverse bisector of a {sup 192}Ir high dose rate (HDR) source at 1 cm from its center in water, D(r{sub 0},{theta}{sub 0}). It consists of a polymethylmethacrylate (PMMA) rod (axial axis) with a cylindrical cavity at its center to insert the {sup 192}Ir radioactive source. A ring cavity around the source with 1.5 mm thickness and 5 mm height is centered at 1 cm from the central axis of the source. This ring cavity is etched in a disk shaped base with 2.65 cm diameter and 0.90 cm thickness. The cavity has a wall around it 0.25 cm thick. This ring is filled with Fricke solution, sealed, and the whole assembly is immersed in water during irradiations. The device takes advantage of the cylindrical geometry to measure D(r{sub 0},{theta}{sub 0}). Irradiations were performed with a Nucletron microselectron HDR unit loaded with an {sup 192}Ir Alpha Omega radioactive source. A Spectronic 1001 spectrophotometer was used to measure the optical absorbance using a 1 mL quartz cuvette with 1.00 cm light pathlength. The PENELOPE Monte Carlo code (MC) was utilized to simulate the Fricke device and the {sup 192}Ir Alpha Omega source in detail to calculate the perturbation introduced by the PMMA material. A NIST traceable calibrated well type ionization chamber was used to determine the air-kerma strength, and a published dose-rate constant was used to determine the dose rate at the reference point. The time to deliver 30.00 Gy to the reference point was calculated. This absorbed dose was then compared to the absorbed dose measured by the Fricke solution. Based on MC simulation, the PMMA of the Fricke device increases the D(r{sub 0},{theta}{sub 0}) by 2.0%. Applying the corresponding correction factor, the D(r{sub 0},{theta}{sub 0}) value assessed with the Fricke device agrees within 2.0% with the expected value with a total combined uncertainty of 3.43%(k=1). The Fricke device provides a promising method towards calibration of brachytherapy radiation sources in terms of D(r{sub 0},{theta}{sub 0}) and audit HDR source calibrations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-204-06: Monte Carlo Dose Calculation for Kilovoltage X-Ray-Psoralen Activated Cancer Therapy (X-PACT): Preliminary Results

Purpose: X-PACT is an experimental cancer therapy where kV x-rays are used to photo-activate anti-cancer therapeutics through phosphor intermediaries (phosphors that absorb x-rays and re-radiate as UV light). Clinical trials in pet dogs are currently underway (NC State College of Veterinary Medicine) and an essential component is the ability to model the kV dose in these dogs. Here we report the commissioning and characterization of a Monte Carlo (MC) treatment planning simulation tool to calculate X-PACT radiation doses in canine trials. Methods: FLUKA multi-particle MC simulation package was used to simulate a standard X-PACT radiation treatment beam of 80kVp with the Varian OBI x-ray source geometry. The beam quality was verified by comparing measured and simulated attenuation of the beam by various thicknesses of aluminum (2–4.6 mm) under narrow beam conditions (HVL). The beam parameters at commissioning were then corroborated using MC, characterized and verified with empirically collected commissioning data, including: percent depth dose curves (PDD), back-scatter factors (BSF), collimator scatter factor(s), and heel effect, etc. All simulations were conducted for N=30M histories at M=100 iterations. Results: HVL and PDD simulation data agreed with an average percent error of 2.42%±0.33 and 6.03%±1.58, respectively. The mean square error (MSE) values for HVL and PDD (0.07% and 0.50%) were low, as expected; however, longer simulations are required to validate convergence to the expected values. Qualitatively, pre- and post-filtration source spectra matched well with 80kVp references generated via SPEKTR software. Further validation of commissioning data simulation is underway in preparation for first-time 3D dose calculations with canine CBCT data. Conclusion: We have prepared a Monte Carlo simulation capable of accurate dose calculation for use with ongoing X-PACT canine clinical trials. Preliminary results show good agreement with measured data and hold promise for accurate quantification of dose for this novel psoralen X-ray therapy. Funding Support, Disclosures, & Conflict of Interest: The Monte Carlo simulation work was not funded; Drs. Adamson & Oldham have received funding from Immunolight LLC for X-PACT research.

60 APPLIED LIFE SCIENCES↗

Bayesian Approach to Estimation of Water Table Elevations Using Historical Rasters as Prior Information 2019 - 20430

In cases of complex but only partially known geology and a lack of spatial control in observation well locations, water table elevation estimation is very challenging. In some cases, auxiliary information, such as observations of the movement of tracers, operation of injection and extraction wells, and calibration of groundwater models against the historical elevation data, can be combined with expert judgement to estimate flow directions in areas of sparse data and to aid in the production of more reliable contour maps (and associated rasters) than could be produced by relying on sparse well elevation data alone. Given a historical sequence of these raster maps, the question arises how to automate, to the extent possible, the process of producing new raster maps to reflect data from previous times, the current data and the operation of expert judgement. One solution is to adopt a Bayesian point of view and to regard the historical well elevation data, auxiliary information and historical raster maps as prior information. The well elevations for water table wells, as well as those for injection/extraction wells and the data associated with other relevant variables, can be viewed as predictors for the raster surface. From this prior information, we can, conditional on the values of these predictors for a new time period, compute an expected value map and a standard deviation map for the new raster. These then can be taken to specify a prior predictive distribution for the pixels in the new raster map. Then we condition the pixels, corresponding to water level observation wells within the raster, on the observed values in those wells (which in general will differ from the regression estimate) for the new time period. Given the smoothness of the water table surface, we then smooth the surface of deviations from the mean surface, based on the variograms of the historical rasters, and add this smoothed surface to the regression mean surface. The error structure of the produced raster map is defined by the regression error structure and the error due to smoothing based on the estimated variograms. This methodology has been developed and is being further refined for groundwater monitoring and remediation at LANL. It is a very flexible method that can also be applied with a variety of other predictors applied to model the water level wells in the area of interest over the historical record. The smoothness of the spatial process and its possible evolution over time can then be estimated from the residuals from this regression. This can be augmented by expert hydrogeological opinion based on site topography and hydrogeology. (authors)

54 ENVIRONMENTAL SCIENCES↗

Criticality Safety Validation of SCALE 6.1 (Revised)

The computational bias of criticality safety computer codes must be established through the validation of the codes to critical experiments. A large collection of suitable experiments has been vetted by the International Criticality Safety Benchmark Experiment Program (ICSBEP) and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). A total of more than 350 cases from this reference have been prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID) maintained by the Reactor and Nuclear Systems Division at Oak Ridge National Laboratory. The performance of the KENO V.a and KENO-VI Monte Carlo codes within the SCALE 6.1 code system with ENDF/B-VII.0 cross-section data in 238-group and continuous energy is assessed using the VALID models of benchmark experiments. The TSUNAMI tools for sensitivity and uncertainty analysis are utilized to examine some systems further in an attempt to identify potential causes of unexpected results. The critical experiments available for validation of the KENO V.a code cover eight different broad categories of systems. These systems use a range of fissile materials including a range of uranium enrichments, various plutonium isotopic vectors, and mixed uranium/plutonium oxides. The physical form of the fissile material also varies and is represented as metal, solutions, or arrays of rods or plates in a water moderator. The neutron energy spectra of the systems also vary and cover both fast and thermal spectra. Over 300 of the total cases used utilize the KENO V.a code. The critical experiments available for the validation of the KENO-VI code cover three broad categories of systems. The fissile materials in the systems vary and include high- and intermediate-enrichment uranium and mixed uranium/plutonium oxides. The physical form of the fissile material is either metal or rod arrays in water. As with KENO V.a, both fast and thermal neutron energy spectra are represented in the systems considered. The results indicate generally good performance of both the KENO V.a and KENO-VI codes across the range of systems analyzed. The bias of calculated k eff from expected values is less than 0.9% Δk in all cases. All eight categories of experiments show biases of less than 0.5% Δk in KENO V.a with the exception of intermediate enrichment metal systems using the 238-group library. The continuous energy library generally manifests lower biases than the multigroup data. The KENO-VI results show slightly larger biases, though this may primarily be the result of modeling systems with more geometric complexity, which are more difficult to describe accurately, even with a generalized geometry code like KENO-VI. Several additional conclusions can be drawn from the results of this validation effort. These conclusions include that the TSUNAMI tools can be used successfully to explain the cause of aberrant results, that some evaluations in the IHECSBE should be updated to provide more rigorous expected k eff values and uncertainties, and that potential cross-section errors can be identified by detailed review of the results of this validation. It also appears that the overall cross-section uncertainty as quantified through the SCALE covariance library is overestimated. Overall, the KENO V.a and KENO-VI codes are shown to provide consistent, low-bias results for a wide range of physical systems of potential interest in criticality safety applications.

Marshall, William (BJ) J.↗

Heavy quark free energy in QCD and in gauge theories with gravity duals

Recent lattice results in pure glue SU(3) theory at high temperatures have shown that the expectation value of the renormalized Polyakov loop approaches its asymptotic limit at high temperatures from above. We show that this implies that the 'heavy quark free energy' obtained from the renormalized loop computed on the lattice does not behave like a true thermodynamic free energy. While this should be expected to occur in asymptotically free gauge theories such as QCD, we use the gauge/string duality to show that in a large class of strongly coupled gauge theories with nontrivial UV fixed points the Polyakov loop reaches its asymptotic value from above only if the dimension of the relevant operator used to deform the conformal field theory is greater than or equal to 3.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron cooling in a young radio supernova: SN 2012aw

We present the radio observations and modeling of an optically bright Type II-P supernova (SN), SN 2012aw which exploded in the nearby galaxy Messier 95 (M95) at a distance of 10 Mpc. The spectral index values calculated using C, X, and K bands are smaller than the expected values for the optically thin regime. During this time, the optical bolometric light curve stays in the plateau phase. We interpret the low spectral-index values to be a result of electron cooling. On the basis of comparison between the Compton cooling timescale and the synchrotron cooling timescale, we find that the inverse Compton cooling process dominates over the synchrotron cooling process. We therefore model the radio emission as synchrotron emission from a relativistic electron population with a high energy cutoff. The cutoff is determined by comparing the electron cooling timescale, t {sub cool}, and the acceleration timescale, t-tilde {sub acc}. We constrain the mass-loss rate in the wind ( M-dot ∼1.9×10{sup −6} M{sub ⊙} yr{sup −1}) and the equipartition factor between relativistic electrons and the magnetic field ( α-tilde =ϵ{sub e}/ϵ{sub B}∼1.12×10{sup 2}) through our modeling of radio emission. Although the time of explosion is fairly well constrained by optical observations within about two days, we explore the effect of varying the time of explosion to best fit the radio light curves. The best fit is obtained for the explosion date as 2012 March 15.3 UT.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection and Interpretation of Long-lived X-Ray Quasi-periodic Pulsations in the X-class Solar Flare on 2013 May 14

Quasi-periodic pulsations (QPP) seen in the time derivative of the GOES soft X-ray light curves are analyzed for the X3.2 event on 2013 May 14. The pulsations are apparent for a total of at least two hours from the impulsive phase to well into the decay phase, with a total of 163 distinct pulses evident to the naked eye. A wavelet analysis shows that the characteristic timescale of these pulsations increases systematically from ∼25 s at 01:10 UT, the time of the GOES peak, to ∼100 s at 02:00 UT. A second “ridge” in the wavelet power spectrum, most likely associated with flaring emission from a different active region, shows an increase from ∼40 s at 01:40 UT to ∼100 s at 03:10 UT. We assume that the QPP that produced the first ridge result from vertical kink-mode oscillations of the newly formed loops following magnetic reconnection in the coronal current sheet. This allows us to estimate the magnetic field strength as a function of altitude given the density, loop length, and QPP timescale as functions of time determined from the GOES light curves and Ramaty High Energy Solar Spectroscopic Imager ( RHESSI ) images. The calculated magnetic field strength of the newly formed loops ranges from ∼500 G at an altitude of 24 Mm to a low value of ∼10 G at 60 Mm, in general agreement with the expected values at these altitudes. Fast sausage-mode oscillations are also discussed and cannot be ruled out as an alternate mechanism for producing the QPP.

79 ASTRONOMY AND ASTROPHYSICS↗

RAPID UNSEPARATED RARE EARTH ELEMENT ANALYSES BY ISOTOPE DILUTION MULTICOLLECTOR INDUCTIVELY COUPLED MASS SPECTROMETRY (ID-MC-ICP-MS)

We present a method for analyzing rare earth elements (REEs) by isotope dilution without separation of individual elements. Utilizing a Nu Plasma 2 multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) equipped with an Aridus II desolvation nebulizer, sample introduction tuning parameters (torch position, gas flows) were investigated and used to minimize oxide formation (e.g., NdO/Nd <0.05%) and remove the need to analyze the REEs as separated “cuts.” Ratios for spike/sample isotopes in mixed synthetic standards containing varying amounts of Ce, Nd, Sm, Eu, Gd, Dy, Er, and Yb were measured accurately within 1% of IUPAC values. La and Lu in the standards were more than 2% off from expected values due to more demanding interference corrections. A USGS BCR-2 rock standard was also processed with flux fusion, iron coprecipitation and a single column pass bulk separation followed by analysis. The concentrations for Ce, Nd, Sm, Eu, Dy, Er, and Yb fell within 2% of consensus values. A United States Geological Survey (USGS) BIR-1A rock standard was also processed in triplicate by hydrofluoric and nitric acid digestion, yielding rare earth concentrations within 3% of consensus values with 0.3% relative standard deviation (n=3). This demonstrates the ability to produce high quality REE patterns of comparable quality to traditional methods involving labor and time intensive REE separation, with sample preparation and analytical times that are comparable to analyses against isotope dilution by single-collector ICP-MS.

Shen, Steve D.↗

Investigating the Relativistic Motion of the Stars Near the Supermassive Black Hole in the Galactic Center

The S-star cluster in the Galactic center allows us to study the physics close to a supermassive black hole, including distinctive dynamical tests of general relativity. Our best estimates for the mass of and the distance to Sgr A* using the three stars with the shortest period (S2, S38, and S55/S0-102) and Newtonian models are M {sub BH} = (4.15 ± 0.13 ± 0.57) × 10{sup 6} M {sub ⊙} and R {sub 0} = 8.19 ± 0.11 ± 0.34 kpc. Additionally, we aim at a new and practical method to investigate the relativistic orbits of stars in the gravitational field near Sgr A*. We use a first-order post-Newtonian approximation to calculate the stellar orbits with a broad range of periapse distance r {sub p} . We present a method that employs the changes in orbital elements derived from elliptical fits to different sections of the orbit. These changes are correlated with the relativistic parameter defined as ϒ ≡ r {sub s} / r {sub p} (with r {sub s} being the Schwarzschild radius) and can be used to derive ϒ from observational data. For S2 we find a value of ϒ = 0.00088 ± 0.00080, which is consistent, within the uncertainty, with the expected value of ϒ = 0.00065 derived from M {sub BH} and the orbit of S2. We argue that the derived quantity is unlikely to be dominated by perturbing influences such as noise on the derived stellar positions, field rotation, and drifts in black hole mass.

79 ASTRONOMY AND ASTROPHYSICS↗