Search NASA⌕ Search

SEARCH · Search NASA

Results for “Error Mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Fast Plasma Investigation for MMS: Simulation of the Burst Triggering System

The Magnetospheric Multiscale (MMS) mission will study small-scale reconnection structures and their rapid motions from closely spaced platforms using instruments capable of high angular, energy, and time resolution measurements. To meet these requirements, the Fast Plasma Instrument (FPI) consists of eight (8) identical half top-hat electron sensors and eight (8) identical ion sensors and an Instrument Data Processing Unit (IDPU). The sensors (electron or ion) are grouped into pairs whose 6 degree x 180 degree fields-of-view (FOV) are set 90 degrees apart. Each sensor is equipped with electrostatic aperture steering to allow the sensor to scan a 45 degree x 180 degree fan about the its nominal viewing (0 deflection) direction. Each pair of sensors, known as the Dual Electron Spectrometer (DES) and the Dual Ion Spectrometer (DIS), occupies a quadrant on the MMS spacecraft and the combination of the eight electron/ion sensors, employing aperture steering, image the full-sky every 30-ms (electrons) and 150-ms (ions), respectively. To probe the diffusion regions of reconnection, the highest temporal/spatial resolution mode of FPI results in the DES complement of a given spacecraft generating 6.5-Mb (raised dot) per second of electron data while the DIS generates 1.1-Mb (raised dot) per second of ion data yielding an FPI total data rate of 6.6-Mb (raised dot) per second. The FPI electron/ion data is collected by the IDPU then transmitted to the Central Data Instrument Processor (CIDP) on the spacecraft for science interest ranking. Only data sequences that contain the greatest amount of temporal/spatial structure will be intelligently down-linked by the spacecraft. This requires a data ranking process known as the burst trigger system. The burst trigger system uses pseudo physical quantities to approximate the local plasma environments. As each pseudo quantity will have a different value, a set of two scaling factors is employed for each pseudo term. These pseudo quantities are then combined at the instrument, spacecraft, and observatory level leading to a final ranking of data based on expected scientific interest. Here, we present simulations of the fixed point burst trigger system for the FPI. A variety of data sets based on previous mission data as well as analytical formulations are tested. Comparisons of floating point calculations versus the fixed point hardware simulation are shown. Analysis of the potential sources of error from overflows, quantization, etc. are examined and mitigation methods are presented. Finally a series of calibration curves are presented, showing the expected error in pseudo quantities based solely on the scale parameters chosen and the expected data range. We conclude with a presentation of the current base-lined FPI burst trigger approach.

Barrie, A. C.↗

EFCOG Best Practice HPI for Knowledge Workers ISM-HPI-22-02

This document is a collection of these best practices as determined by team members. This best practice attempts to: Realize opportunities to break the myth where people believe that HPI does not apply to them as they perform no physical work. Recommend options to create an environment that promotes intellectual collaboration and trust, enabling candor and vulnerability. Explain how errors manifest differently from the same human fallibility. Knowledge workers (KW) have errors that take different perspectives to find and mitigate the unique manifestation of these conditions. Help KW identify the critical steps (or risk important steps) in their processes. Reduce risk/consequence from KW errors (limit latent errors as well as finding latent conditions), building resiliency into KW tasks. Mitigation strategies may be different.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters

Near-infrared spectroscopy (NIRS) can be used to noninvasively measure changes in the concentrations of oxy- and deoxyhemoglobin in tissue. We have previously shown that while global changes can be reliably measured, focal changes can produce erroneous estimates of concentration changes (NeuroImage 13 (2001), 76). Here, we describe four separate sources for systematic error in the calculation of focal hemoglobin changes from NIRS data and use experimental methods and Monte Carlo simulations to examine the importance and mitigation methods of each. The sources of error are: (1). the absolute magnitudes and relative differences in pathlength factors as a function of wavelength, (2). the location and spatial extent of the absorption change with respect to the optical probe, (3). possible differences in the spatial distribution of hemoglobin species, and (4). the potential for simultaneous monitoring of multiple regions of activation. We found wavelength selection and optode placement to be important variables in minimizing such errors, and our findings indicate that appropriate experimental procedures could reduce each of these errors to a small fraction (<10%) of the observed concentration changes.

Non-NASA Center↗

Inverse Solutions in Spectroscopic Analysis with Applications to Problems in Global Safeguards

This work describes a nondestructive strategy and algorithm designed to evaluate the burnup and plutonium content of light-water-reactor spent fuel and thereby confirm declared values. In contrast with previous methods that focus on only a few photopeaks (e.g., 137 Cs at 662 keV), the present approach involves the entire gamma spectrum up to 2000 keV. Spectra are used as input for the inverse code INDEPTH, which is designed to predict reactor parameters (fuel enrichment, power level, irradiation time, and cooling time) when given either a set of nuclide inventories or the gamma spectrum that they produce. This approach has the advantage of often making possible the determination of parameters other than burnup when they are unknown or in doubt. In addition, error in one photopeak evaluation is mitigated by the inclusion of the entire spectrum. The solution procedure involves multiple runs of the forward code ORIGEN/ARP, each of which produces an extensive list of nuclides formed through depletion/decay processes. The gamma spectrum of these nuclides is compared with the gamma spectrum from a detector through a bin-by-bin sum of squared error. New choices for the reactor parameters that are input to ORIGEN/ARP are determined using a gradient search technique, and the best parameter set is that which minimizes the squared error between calculated and measured gamma spectra. The method is applied to the analysis of gamma data taken from various sections of actual spent reactor fuel and is compared with declared values and other methods of evaluation. The sensitivity of the inverse solution with respect to various parameters is calculated and indicates that the algorithm is stable and robust. One example includes the presence of multiple solutions, each of which can be characterized using additional information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photoelectron spectra of copper oxide cluster anions from first principles methods

We present results and analyses for the photoelectron spectra of small copper oxide cluster anions (CuO – , CuO – 2 , CuO – 3 , and Cu 2 O – ). The spectra are computed using various techniques, including density functional theory (DFT) with semi-local, global hybrid, and optimally tuned range-separated hybrid functionals, as well as many-body perturbation theory within the GW approximation based on various DFT starting points. The results are compared with each other and with the available experimental data. We conclude that as in many metal-organic systems, self-interaction errors are a major issue that is mitigated by hybrid functionals. However, these need to be balanced against a strong role of non-dynamical correlation—especially in smaller, more symmetric systems—where errors are alleviated by semi-local functionals. In conclusion, the relative importance of the two phenomena, including practical ways of balancing the two constraints, is discussed in detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Common Cause Failure Mitigation Experience on Digital I and C System in NPP

CCF is failures of redundant or separate structures, systems, or components due to a shared root cause. The CCF includes those are resulted from severe environments, design errors, calibration and maintenance errors, and consequential failures. In addition, digital I and C systems can be vulnerable to CCF caused by software errors or software developed logic, which could defeat the redundancy achieved by the hardware architecture. Therefore, diversity and defense in-depth (D3) has become an important issue to overcome the CCF of the safety I and C system. The U.S. NRC has established regulatory guidance addressing a method for assessing D3 provided by the safety I and C system architecture at a NPP. This method enables determination of whether vulnerabilities to CCF have been adequately addressed. The guidance is included in BTP 7-19 and Chapter 7 of NUREG-0800. The regulatory guidance provides a methodology for designing diversity. APR1400 establishes the mitigating strategies that consider the characteristics of digital I and C system that contribute to the potential for CCF. The diversity strategies consist of a combination of diversity attributes and associated criteria to address potential CCF vulnerabilities in digital safety I and C system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Band-gap corrected density functional theory calculations for InAs/GaSb type II superlattices

We performed pseudopotential based density functional theory (DFT) calculations for GaSb/InAs type II superlattices (T2SLs), with bandgap errors from the local density approximation mitigated by applying an empirical method to correct the bulk bandgaps. Specifically, this work (1) compared the calculated bandgaps with experimental data and non-self-consistent atomistic methods; (2) calculated the T2SL band structures with varying structural parameters; (3) investigated the interfacial effects associated with the no-common-atom heterostructure; and (4) studied the strain effect due to lattice mismatch between the two components. This work demonstrates the feasibility of applying the DFT method to more exotic heterostructures and defect problems related to this material system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Understanding and Estimating Error Propagation in Neural Networks for Scientific Data Analysis

Neural networks are increasingly integrated into scientific discovery, where input data reduction and model quantization play a key role in accelerating inference. However, understanding and mitigating the impact of these techniques on output error is critical for ensuring reliable results, particularly in tasks demanding high numerical precision. This paper introduces a comprehensive framework for optimizing neural network inference in scientific computing by combining data reduction and weight quantization while maintaining error-controlled outcomes. We develop theoretical analyses to bound error propagation under these reductions and propose a framework that balances computational performance with error constraints. Evaluation on real-world learning-based combustion simulations and satellite image classification demonstrates that our derived error bounds accurately predict observed errors while enabling significant computational speedup under our framework. This work highlights the potential for further leveraging advancements in modern lossy compression algorithms and hardware accelerators that support lower-precision formats.

He, Weiming [New Jersey Institute of Technology]↗

SU-E-T-269: Differential Hazard Analysis For Conventional And New Linac Acceptance Testing Procedures

Purpose: New techniques and materials have recently been developed to expedite the conventional Linac Acceptance Testing Procedure (ATP). The new ATP method uses the Electronic Portal Imaging Device (EPID) for data collection and is presented separately. This new procedure is meant to be more efficient then conventional methods. While not clinically implemented yet, a prospective risk assessment is warranted for any new techniques. The purpose of this work is to investigate the risks and establish the pros and cons between the conventional approach and the new ATP method. Methods: ATP tests that were modified and performed with the EPID were analyzed. Five domain experts (Medical Physicists) comprised the core analysis team. Ranking scales were adopted from previous publications related to TG 100. The number of failure pathways for each ATP test procedure were compared as well as the number of risk priority numbers (RPN’s) greater than 100 were compared. Results: There were fewer failure pathways with the new ATP compared to the conventional, 262 and 556, respectively. There were fewer RPN’s > 100 in the new ATP compared to the conventional, 41 and 115. Failure pathways and RPN’s > 100 for individual ATP tests on average were 2 and 3.5 times higher in the conventional ATP compared to the new, respectively. The pixel sensitivity map of the EPID was identified as a key hazard to the new ATP procedure with an RPN of 288 for verifying beam parameters. Conclusion: The significant decrease in failure pathways and RPN’s >100 for the new ATP mitigates the possibilities of a catastrophic error occurring. The Pixel Sensitivity Map determining the response and inherent characteristics of the EPID is crucial as all data and hence results are dependent on that process. Grant from Varian Medical Systems Inc.

60 APPLIED LIFE SCIENCES↗

Development and testing of a photometric method to identify non-operating solar hot water systems in field settings

This report presents the results of experimental tests of a concept for using infrared (IR) photos to identify non-operational systems based on their glazing temperatures; operating systems have lower glazing temperatures than those in stagnation. In recent years thousands of new solar hot water (SHW) systems have been installed in some utility districts. As these numbers increase, concern is growing about the systems dependability because installation rebates are often based on the assumption that all of the SHW systems will perform flawlessly for a 20-year period. If SHW systems routinely fail prematurely, then the utilities will have overpaid for grid-energy reduction performance that is unrealized. Moreover, utilities are responsible for replacing energy for loads that failed SHW system were supplying. Thus, utilities are seeking data to quantify the reliability of SHW systems. The work described herein is intended to help meet this need. The details of the experiment are presented, including a description of the SHW collectors that were examined, the testbed that was used to control the system and record data, the IR camera that was employed, and the conditions in which testing was completed. The details of the associated analysis are presented, including direct examination of the video records of operational and stagnant collectors, as well as the development of a model to predict glazing temperatures and an analysis of temporal intermittency of the images, both of which are critical to properly adjusting the IR camera for optimal performance. Many IR images and a video are presented to show the contrast between operating and stagnant collectors. The major conclusion is that the technique has potential to be applied by using an aircraft fitted with an IR camera that can fly over an area with installed SHW systems, thus recording the images. Subsequent analysis of the images can determine the operational condition of the fielded collectors. Specific recommendations are presented relative to the application of the technique, including ways to mitigate and manage potential sources of error.

15 GEOTHERMAL ENERGY↗

PIP-II LLRF Master Oscillator and Precision Reference Line - Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago]↗

Non-trivial symmetries in quantum landscapes and their resilience to quantum noise

Very little is known about the cost landscape for parametrized Quantum Circuits (PQCs). Nevertheless, PQCs are employed in Quantum Neural Networks and Variational Quantum Algorithms, which may allow for near-term quantum advantage. Such applications require good optimizers to train PQCs. Recent works have focused on quantum-aware optimizers specifically tailored for PQCs. However, ignorance of the cost landscape could hinder progress towards such optimizers. In this work, we analytically prove two results for PQCs: (1) We find an exponentially large symmetry in PQCs, yielding an exponentially large degeneracy of the minima in the cost landscape. Alternatively, this can be cast as an exponential reduction in the volume of relevant hyperparameter space. (2) We study the resilience of the symmetries under noise, and show that while it is conserved under unital noise, non-unital channels can break these symmetries and lift the degeneracy of minima, leading to multiple new local minima. Based on these results, we introduce an optimization method called Symmetry-based Minima Hopping (SYMH), which exploits the underlying symmetries in PQCs. Our numerical simulations show that SYMH improves the overall optimizer performance in the presence of non-unital noise at a level comparable to current hardware. Overall, this work derives large-scale circuit symmetries from local gate transformations, and uses them to construct a noise-aware optimization method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mitigation of High Altitude and Low Earth Orbit Radiation Effects on Microelectronics via Shielding or Error Detection and Correction Systems

The NASA Cooperative Agreement NAG4-210 was granted under the FY2000 Faculty Awards for Research (FAR) Program. The project was proposed to examine the effects of charged particles and neutrons on selected random access memory (RAM) technologies. The concept of the project was to add to the current knowledge of Single Event Effects (SEE) concerning RAM and explore the impact of selected forms of radiation on Error Detection and Correction Systems. The project was established as an extension of a previous FAR awarded to Prairie View A&M University (PVAMU), under the direction of Dr. Richard Wilkins as principal investigator. The NASA sponsored Center for Applied Radiation Research (CARR) at PVAMU developed an electronic test-bed to explore and quantify SEE on RAM from charged particles and neutrons. The test-bed was developed using 486DX microprocessor technology (PC-104) and a custom test board to mount RAM integrated circuits or other electronic devices. The test-bed had two configurations - a bench test version for laboratory experiments and a 400 Hz powered rack version for flight experiments. The objectives of this project were to: 1) Upgrade the Electronic Test-bed (ETB) to a Pentium configuration; 2) Accommodate more than only 8 Mbytes of RAM; 3) Explore Error Detection and Correction Systems for radiation effects; 4) Test modern RAM technologies in radiation environments.

Gupta, Kajal↗

Modeling of Deadbanding DV for the Stardust Earth Return: Calibration, Analysis, Prediction and Performance

On January 15th, 2006, 0556 UTC, the Stardust spacecraft released a 42-kg Sample Return Canister (SRC) along a trajectory intended to impact a target on the Air Force Utah Test and Training Range (UTTR), near Dugway, Utah. Assurances of a successful SRC delivery to UTTR depended on identifying (and mitigating, if possible) a myriad of error sources. These sources included atmospheric effects, maneuver execution, Orbit Determination (OD) uncertainties and (Delta)V induced by the firing of the unbalanced Reaction Control System (RCS) thrusters needed for deadband attitude control. Every mm/s in prediction error at the TCM-19 epoch would amount to missing the target by approximately one kilometer. This paper will describe the work performed in analyzing and predicting the levels of (Delta)V caused by the attitude deadbanding, as well as prediction performance.

Stardust↗

Using Thin-Film Thermometers as Heaters in Thermal Control Applications

A cryogenic sensor maintains calibration at approximately equal to 4.2 K to better than 2 mK (< 0.5 percent resistance repeatability) after being heated to approximately equal 40 K with approximately equal 0.5 W power. The sensor withstands 4 W power dissipation when immersed in liquid nitrogen with verified resistance reproducibility of, at worst, 1 percent. The sensor maintains calibration to 0.1 percent after being heated with 1-W power at approximately equal 77 K for a period of 48 hours. When operated with a readout scheme that is capable of mitigating the self-heating calibration errors, this and similar sensors can be used for precision (mK stability) temperature control without the need of separate heaters and associated wiring/cabling.

Cho, Hyung J.↗

Post-Coronagraph Wavefront Sensor for Gemini Planet Imager

The calibration wavefront system for the Gemini Planet Imager (GPI) will measure the complex wavefront at the apodized pupil and provide slow phase errors to the AO system to mitigate against image plane speckles that would cause a loss in contrast. This talk describes both the low-order and high-order sensors in the calibration wavefront sensor and how the information is combined to form the wavefront estimate before the coronagraph. We will show laboratory results from our calibration testbed that demonstrate the subsystem performance at levels commensurate with those required on the final instrument.

interferometry↗