Search NASA⌕ Search

SEARCH · Search NASA

Results for “Error analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Notes on Regression Analysis for Radar Parameter Estimation

A fundamental task of radar, beyond merely detecting a target, is to estimate some parameters associated with it. For example, this might include range, direction, velocity, etc. In any case, multiple measurements, often noisy, need to be processed to yield a ‘best estimate’ of the parameter. A common mathematical method for doing so is called “Regression” analysis. The goal is to minimize the expected squared error in the estimate. Even when alternate algorithms are considered, the least squared-error regression analysis is the benchmark against which alternatives are compared.

47 OTHER INSTRUMENTATION↗

Mechanistic Modeling of TEG Dehydrator Emissions in Oil and Gas Industry

This work presents a mechanistic modeling approach for simulating methane emissions from triethylene glycol (TEG) dehydrators used in oil & gas (O&G) operations. The model was developed as a modular component of the Mechanistic Air Emissions Simulator (MAES) tool, incorporating species-specific absorption and emission dynamics through two-level, second-order polynomial regression (PR) models trained on ProMax simulation data: (1) species-level regression models that track the transfer rates of individual gas species within the dehydrator unit streams, and (2) outlet flow stream regression models that predict the fraction of inlet gas distributed among the outlet streams of the dehydrator unit. These behaviors were characterized over a range of glycol circulation ratios, wet gas pressures, and temperatures. The model was validated using root mean square error (RMSE) analysis. The species-level PR achieved low root mean square error (RMSE) values (<0.03) for light hydrocarbon species across all dehydrator components, ranging from 0.0009 for methane to 0.029 for normal pentane. Similarly, the outlet-level PR yielded RMSE values below 0.002 for the dry gas fraction, 0.001 for the flash tank fraction, and 0.002 for the still vent fraction, demonstrating strong agreement between predicted and reference ProMax values. When deployed at field facilities, the model significantly improved MAES-simulated dehydrator emissions, revealing that gas-assisted glycol pump emissions are the dominant contributors to both dehydrator-level and site-level methane emissions under uncontrolled conditions. Further analysis of the 154 dehydrator units reported by operators under the AMI 2024 project showed that 54 units (31%) used gas-driven glycol pumps, of which 6 units (11%) operated with uncontrolled flash tanks, and 22 units (40.7%) were identified as potentially oversized. Of the six dehydrator units with uncontrolled gas-assisted pumps, pump emissions accounted for 90.25% of total dehydrator emissions and 63.10% of total site-level emissions. These findings highlight substantial opportunities for emissions mitigation through equipment upgrades.

MAES↗

Analysis of the effects of mismatched errors on coherent beam combining based on a self-imaging waveguide

A theoretical model of coherent beam combining (CBC) based on a self-imaging waveguide (SIW) is built and the effects of mismatched errors on SIW-based CBC are simulated and analysed numerically. With the combination of the theoretical model and the finite difference beam propagation method, two main categories of errors, assembly and nonassembly errors, are numerically studied to investigate their effect on the beam quality by using the M{sup 2} factor. The optimisation of the SIW and error control principle of the system is briefly discussed. The generalised methodology offers a good reference for investigating waveguide-based high-power coherent combining of fibre lasers in a comprehensive way. (lasers and laser beams)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Benchmarking of a treatment planning system for spot scanning proton therapy: Comparison and analysis of robustness to setup errors of photon IMRT and proton SFUD treatment plans of base of skull meningioma

Purpose: Base of skull meningioma can be treated with both intensity modulated radiation therapy (IMRT) and spot scanned proton therapy (PT). One of the main benefits of PT is better sparing of organs at risk, but due to the physical and dosimetric characteristics of protons, spot scanned PT can be more sensitive to the uncertainties encountered in the treatment process compared with photon treatment. Therefore, robustness analysis should be part of a comprehensive comparison between these two treatment methods in order to quantify and understand the sensitivity of the treatment techniques to uncertainties. The aim of this work was to benchmark a spot scanning treatment planning system for planning of base of skull meningioma and to compare the created plans and analyze their robustness to setup errors against the IMRT technique. Methods: Plans were produced for three base of skull meningioma cases: IMRT planned with a commercial TPS [Monaco (Elekta AB, Sweden)]; single field uniform dose (SFUD) spot scanning PT produced with an in-house TPS (PSI-plan); and SFUD spot scanning PT plan created with a commercial TPS [XiO (Elekta AB, Sweden)]. A tool for evaluating robustness to random setup errors was created and, for each plan, both a dosimetric evaluation and a robustness analysis to setup errors were performed. Results: It was possible to create clinically acceptable treatment plans for spot scanning proton therapy of meningioma with a commercially available TPS. However, since each treatment planning system uses different methods, this comparison showed different dosimetric results as well as different sensitivities to setup uncertainties. The results confirmed the necessity of an analysis tool for assessing plan robustness to provide a fair comparison of photon and proton plans. Conclusions: Robustness analysis is a critical part of plan evaluation when comparing IMRT plans with spot scanned proton therapy plans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Pointing Self-calibration Algorithm for Aperture Synthesis Radio Telescopes

This paper is concerned with algorithms for calibration of direction-dependent effects (DDE) in aperture synthesis radio telescopes (ASRT). After correction of direction-independent effects (DIE) using self-calibration, imaging performance can be limited by the imprecise knowledge of the forward gain of the elements in the array. In general, the forward gain pattern is directionally dependent and varies with time due to a number of reasons. Some factors, such as rotation of the primary beam with Parallactic Angle for Azimuth–Elevation mount antennas are known a priori. Some, such as antenna pointing errors and structural deformation/projection effects for aperture-array elements cannot be measured a priori. Thus, in addition to algorithms to correct for DD effects known a priori, algorithms to solve for DD gains are required for high dynamic range imaging. Here, we discuss a mathematical framework for antenna-based DDE calibration algorithms and show that this framework leads to computationally efficient optimal algorithms that scale well in a parallel computing environment. As an example of an antenna-based DD calibration algorithm, we demonstrate the Pointing SelfCal (PSC) algorithm to solve for the antenna pointing errors. Our analysis show that the sensitivity of modern ASRT is sufficient to solve for antenna pointing errors and other DD effects. We also discuss the use of the PSC algorithm in real-time calibration systems and extensions for antenna Shape SelfCal algorithm for real-time tracking and corrections for pointing offsets and changes in antenna shape.

79 ASTRONOMY AND ASTROPHYSICS↗

Deployment of Traditional and Hybrid Machine Learning for Critical Heat Flux Prediction in the CTF Thermal-Hydraulics Code

Critical heat flux (CHF) marks the transition from nucleate to film boiling, where heat transfer to the working fluid can rapidly deteriorate. Accurate CHF prediction is essential for efficiency, safety, and preventing equipment damage, particularly in nuclear reactors. Although widely used, empirical correlations frequently exhibit discrepancies when compared to experimental data, limiting their reliability in diverse operational conditions. Traditional machine learning (ML) approaches have demonstrated potential for CHF prediction but often suffer from limited interpretability, data scarcity, and insufficient knowledge of physical principles. Hybrid model approaches, which combine data-driven ML with base models, mitigate these concerns by incorporating prior knowledge of the domain. This study integrates an externally trained purely data-driven ML model and two hybrid models (using the Biasi and Bowring CHF correlations) within the CTF subchannel code via a custom Fortran framework. Performance was evaluated using two validation cases: a subset of the Nuclear Regulatory Commission (NRC) CHF database and the Bennett dryout experiments. In both cases, the hybrid models demonstrated significantly lower error metrics compared to conventional empirical correlations, with the best models often reducing relative error by about 5 percentage points. The pure ML model achieved comparable accuracy, outperforming the hybrid Biasi model in the NRC test case (3.3% versus 5.5% relative error) but exhibiting slightly higher error against the hybrid Bowring model in the Bennett test case (7.7% versus 6.1%). Trend analysis of error parity indicated that ML-based models reduced the tendency for CHF overprediction, improving overall accuracy. These results demonstrate that ML-based CHF models can be effectively integrated into subchannel codes and could potentially increase performance compared to conventional methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PHOTOMETRIC CALIBRATION OF THE FIRST 1.5 YEARS OF THE PAN-STARRS1 SURVEY

We present a precise photometric calibration of the first 1.5 years of science imaging from the Pan-STARRS1 survey (PS1), an ongoing optical survey of the entire sky north of declination -30 Degree-Sign in five bands. Building on the techniques employed by Padmanabhan et al. in the Sloan Digital Sky Survey (SDSS), we use repeat PS1 observations of stars to perform the relative calibration of PS1 in each of its five bands, simultaneously solving for the system throughput, the atmospheric transparency, and the large-scale detector flat field. Both internal consistency tests and comparison against the SDSS indicate that we achieve relative precision of <10 mmag in g, r, and i{sub P1}, and {approx}10 mmag in z and y{sub P1}. The spatial structure of the differences with the SDSS indicates that errors in both the PS1 and SDSS photometric calibration contribute similarly to the differences. The analysis suggests that both the PS1 system and the Haleakala site will enable <1% photometry over much of the sky.

79 ASTRONOMY AND ASTROPHYSICS↗

A Visual Comparison of Silent Error Propagation

High-performance computing (HPC) systems play a critical role in facilitating scientific discoveries. Their scale and complexity (e.g., the number of computational units and software stack) continue to grow as new systems are expected to process increasingly more data and reduce computing time. However, with more processing elements, the probability that these systems will experience a random bit-flip error that corrupts a program's output also increases, which is often recognized as silent data corruption. Analyzing the resiliency of HPC applications in extreme-scale computing to silent data corruption is crucial but difficult. An HPC application often contains a large number of computation units that need to be tested, and error propagation caused by error corruption is complex and difficult to interpret. Here, to accommodate this challenge, we propose an interactive visualization system that helps HPC researchers understand the resiliency of HPC applications and compare their error propagation. Our system models an application's error propagation to study a program's resiliency by constructing and visualizing its fault tolerance boundary. Coordinating with multiple interactive designs, our system enables domain experts to efficiently explore the complicated spatial and temporal correlation between error propagations. At the end, the system integrated a nonmonotonic error propagation analysis with an adjustable graph propagation visualization to help domain experts examine the details of error propagation and answer such questions as why an error is mitigated or amplified by program execution.

97 MATHEMATICS AND COMPUTING↗

Nuclear Explosion Monitoring

Teleseismic events (earthquakes or explosions) generate strong seismic energy waves that propagate largely in the mantle. For example, the Threshold Test Ban Treaty restricted nuclear tests to be less that 150 kilotons in size, and explosions of this size generate seismic energy waves that are observed teleseismically. Teleseismic monitoring for explosions answers three questions: Where is the seismic event located? Is the event an explosion or natural (event identification)? If an explosion, how large was it? Resolving whether an explosion is chemical or nuclear can require additional analysis (e.g., analysis of atmospherically observed chemical and nuclear spectra). Because of the political ramifications of event identification errors, risk analysis in the context of nuclear explosion monitoring is unique.

explosion monitoring↗

In Situ Ion Counting for Improved Implanted Ion Error Rate and Silicon Vacancy Yield Uncertainty

An in situ counted ion implantation experiment improving the error on the number of ions required to form a single optically active silicon vacancy (SiV) defect in diamond 7-fold compared to timed implantation is presented. Here, traditional timed implantation relies on a beam current measurement followed by implantation with a preset pulse duration. It is dominated by Poisson statistics, resulting in large errors for low ion numbers. Instead, our in situ detection, measuring the ion number arriving at the substrate, results in a 2-fold improvement of the error on the ion number required to generate a single SiV compared to timed implantation. Through postimplantation analysis, the error is improved 7-fold compared to timed implantation. SiVs are detected by photoluminescence spectroscopy, and the yield of 2.98% is calculated through the photoluminescence count rate. Hanbury–Brown–Twiss interferometry is performed on locations potentially hosting single-photon emitters, confirming that 82% of the locations exhibit single photon emission statistics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Performance of a MEMS-based AO-OCT system using Fourier Reconstruction

Adaptive optics (AO) and optical coherence tomography (OCT) are powerful imaging modalities that, when combined, can provide high-resolution (3.5 {micro}m isotropic), 3-D images of the retina. The AO-OCT system at UC Davis has demonstrated the utility of this technology for microscopic, volumetric, in vivo retinal imaging. The current system uses an AOptix bimorph deformable mirror (DM) for low-order, high-stroke correction and a 140-actuator Boston Micromachines DM for high-order correction. Developments to improve performance or functionality of the instrument are on-going. Based on previous work in system characterization we have focused on improved AO control. We present preliminary results and remaining challenges for a newly implemented Fourier transform reconstructor (FTR). The previously reported error budget analysis is also reviewed and updated, with consideration of how to improve both the amount of residual error and the robustness of the system. Careful characterization of the AO system will lead to improved performance and inform the design of future systems.

59 BASIC BIOLOGICAL SCIENCES↗

Enhancing ZFP: A Statistical Approach to Understanding and Reducing Error Bias in a Lossy Floating-Point Compression Algorithm

The amount of data generated and gathered in scientific simulations and data collection applications is continuously growing, putting mounting pressure on storage and bandwidth concerns. A means of reducing such issues is data compression; but, lossless data compression is typically ineffective when applied to floating-point data. Thus, users tend to apply a lossy data compressor, which allows for small deviations from the original data. It is essential to understand how the error from lossy compression impacts the accuracy of the data analytics. Thus, we must analyze not only the compression properties but the error as well. In this paper, we provide a statistical analysis of the error caused by ZFP compression, a state-of-the-art, lossy compression algorithm explicitly designed for floating-point data. We show that the error is indeed biased and propose simple modifications to the algorithm to neutralize the bias and further reduce the resulting error.

97 MATHEMATICS AND COMPUTING↗

DETERMINING THE ABSOLUTE ASTROMETRIC ERROR IN CHANDRA SOURCE CATALOG POSITIONS

Although relative errors can readily be calculated, the absolute astrometric accuracy of the source positions in the Chandra Source Catalog (CSC), version 1.0, is a priori unknown. However, the cross-match with stellar objects from the Sloan Digital Sky Survey offers the opportunity to compare the apparent separations of the cross-matched pairs with the formally calculated errors. The analysis of these data allowed us to derive a value of 0.''16 for the residual absolute astrometric error in CSC positions. This error will be added to the published position errors in the CSC from now on, starting with CSC, version 1.1.

79 ASTRONOMY AND ASTROPHYSICS↗

A study of examiner accuracy in cartridge case comparisons. Part 2: Examiner use of the AFTE range of conclusions

Here, this report describes an analysis of how examiners used the Association of Firearm and Toolmark Examiners (AFTE) Range of Conclusions in a controlled study undertaken to estimate examiner error rates in comparing cartridge cases. Results of the error rate analysis are reported in [1]; this paper focuses on a broader analysis of how the entire collection of classification categories, especially those in the Inconclusive range, were used by the participating examiners. Volunteer active examiners with AFTE membership or working in laboratories that participate in Association of Crime Laboratory Directors (ASCLD) were provided with 15 sets of three known and one questioned cartridge cases fired from a collection of 25 new Ruger SR9 handguns. Remington 9-mm Luger (manufacturer designation L9MM3) ammunition was used and comparison sets were made up of cartridge cases fired within 100 cartridges of each other for each gun. Examiners were provided with a background survey, an answer sheet allowing for the AFTE Range of Conclusions, and return shipping materials. The participating examiners were provided with both same-source and different-source comparison sets allowing the study to assess both error rates. Responses were received from 218 participating examiners. The overall rate of false-negatives was estimated as 0.367 % from comparisons known to be from the same firearm but reported as eliminations. The overall rate of false-positives was estimated as 1.01 % from comparisons known to be from different firearms but reported as identifications. In the case of true different-source examinations, it is clear that the three Inconclusive categories and the Elimination category are not used consistently by all examiners. We identify five different apparent patterns of use of the AFTE Range of Conclusions scale, and discuss possible reasons for and implications of these differences.

99 GENERAL AND MISCELLANEOUS↗

Optimal 1D Ly α forest power spectrum estimation – III. DESI early data

ABSTRACT The 1D power spectrum P1D of the Ly α forest provides important information about cosmological and astrophysical parameters, including constraints on warm dark matter models, the sum of the masses of the three neutrino species, and the thermal state of the intergalactic medium. We present the first measurement of P1D with the quadratic maximum likelihood estimator (QMLE) from the Dark Energy Spectroscopic Instrument (DESI) survey early data sample. This early sample of 54 600 quasars is already comparable in size to the largest previous studies, and we conduct a thorough investigation of numerous instrumental and analysis systematic errors to evaluate their impact on DESI data with QMLE. We demonstrate the excellent performance of the spectroscopic pipeline noise estimation and the impressive accuracy of the spectrograph resolution matrix with 2D image simulations of raw DESI images that we processed with the DESI spectroscopic pipeline. We also study metal line contamination and noise calibration systematics with quasar spectra on the red side of the Ly α emission line. In a companion paper, we present a similar analysis based on the Fast Fourier Transform estimate of the power spectrum. We conclude with a comparison of these two approaches and discuss the key sources of systematic error that we need to address with the upcoming DESI Year 1 analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative assessment of fitting errors associated with streak camera noise in Thomson scattering data analysis

Thomson scattering measurements in high energy density experiments are often recorded using optical streak cameras. In the low-signal regime, noise introduced by the streak camera can become an important and sometimes the dominant source of measurement uncertainty. In this paper, we present a formal method of accounting for the presence of streak camera noise in our measurements. We present a phenomenological description of the noise generation mechanisms and present a statistical model that may be used to construct the covariance matrix associated with a given measurement. This model is benchmarked against simulations of streak camera images. We demonstrate how this covariance may then be used to weight fitting of the data and provide quantitative assessments of the uncertainty in the fitting parameters determined by the best fit to the data and build confidence in the ability to make statistically significant measurements in the low-signal regime, where spatial correlations in the noise become apparent. These methods will have general applicability to other measurements made using optical streak cameras.

47 OTHER INSTRUMENTATION↗

Rigorous constraints on three-nucleon forces in chiral effective field theory from fast and accurate calculations of few-body observables

We explore the constraints on the three-nucleon force (3NF) of chiral effective field theory (χ EFT) that are provided by bound-state observables in the A = 3 and A = 4 sectors. Our statistically rigorous analysis incorporates experimental error, computational method uncertainty, and the uncertainty due to truncation of the χ EFT expansion at next-to-next-to-leading order. A consistent solution for the 3 H binding energy, the 4 He binding energy and radius, and the 3 H β-decay rate can only be obtained if χ EFT truncation errors are included in the analysis. Here, the β-decay rate is the only one of these that yields a nondegenerate constraint on the 3NF low-energy constants, which makes it crucial for the parameter estimation. We use eigenvector continuation for fast and accurate emulation of no-core shell model calculations of the few-nucleon observables. This facilitates sampling of the posterior probability distribution, allowing us to also determine the distributions of the parameters that quantify the truncation error. We find a χ EFT expansion parameter of Q = 0.33 ± 0.06 for these observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis and mitigation of systematic errors in spectral shearing interferometry of pulses approaching the single-cycle limit [Invited]

We derive an analytical approximation for the measured pulse width error in spectral shearing methods, such as spectral phase interferometry for direct electric-field reconstruction (SPIDER), caused by an anomalous delay between the two sheared pulse components. This analysis suggests that, as pulses approach the single-cycle limit, the resulting requirements on the calibration and stability of this delay become significant, requiring precision orders of magnitude higher than the scale of a wavelength. This is demonstrated by numerical simulations of SPIDER pulse reconstruction using actual data from a sub-two-cycle laser. We briefly propose methods to minimize the effects of this sensitivity in SPIDER and review variants of spectral shearing that attempt to avoid this difficulty.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗