Search NASA⌕ Search

SEARCH · Search NASA

Results for “Event detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Deep drilling in the time domain with DECam – II: characterizing the light curves of candidates in the extragalactic fields

ABSTRACT In this second paper on the DECam deep-drilling field (DDF) program, we release 2020 optical $gri$-band light curves for transients and variables in the extragalactic COSMOS and ELAIS fields based on time series observations with a 3-d cadence from semester 2021A through 2023A. In order to demonstrate the wide variety of time domain events detected by the program and encourage others to use the data set, we characterize the sample by presenting a brief analysis of the light-curve parameters such as time span, amplitude, and peak brightness. We also present preliminary light-curve categorizations, and identify potential stellar variables, active galactic nuclei, tidal disruption events, supernovae (SNe) (such as Type Ia, Type IIP, superluminous, and gravitationally lensed SNe), and fast transients. Where relevant, the number of identified transients is compared to the predictions of the original proposal. We also discuss the challenges of analyzing DDF data in the context of the upcoming Vera C. Rubin Observatory and its Legacy Survey of Space and Time, which will include DDFs. Images from the Dark Energy Camera DDF program are available without proprietary period and the light curves presented in this work are publicly available for analysis.

Graham, Melissa L. (ORCID:0000000291543136)↗

Spatial-Temporal Recurrent Graph Neural Networks for Fault Diagnostics in Power Distribution Systems

Fault diagnostics are extremely important to decide proper actions toward fault isolation and system restoration. The growing integration of inverter-based distributed energy resources imposes strong influences on fault detection using traditional overcurrent relays. This paper utilizes emerging graph learning techniques to build new temporal recurrent graph neural network models for fault diagnostics. The temporal recurrent graph neural network structures can extract the spatial-temporal features from data of voltage measurement units installed at the critical buses. From these features, fault event detection, fault type/phase classification, and fault location are performed. Compared with previous works, the proposed temporal recurrent graph neural networks provide a better generalization for fault diagnostics. Moreover, the proposed scheme retrieves the voltage signals instead of current signals so that there is no need to install relays at all lines of the distribution system. Therefore, the proposed scheme is generalizable and not limited by the number of relays installed. The effectiveness of the proposed method is comprehensively evaluated on the Potsdam microgrid and IEEE 123-node system in comparison with other neural network structures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sky Event Reporting Metadata (VOEvent) Version 2.0

VOEvent [20] defines the content and meaning of a standard information packet for representing, transmitting, publishing and archiving information about a transient celestial event, with the implication that timely follow-up is of interest. The objective is to motivate the observation of targets-of-opportunity, to drive robotic telescopes, to trigger archive searches, and to alert the community. VOEvent is focused on the reporting of photon events, but events mediated by disparate phenomena such as neutrinos, gravitational waves, and solar or atmospheric particle bursts may also be reported. Structured data is used, rather than natural language, so that automated systems can effectively interpret VOEvent packets. Each packet may contain zero or more of the "who, what, where, when & how" of a detected event, but in addition, may contain a hypothesis (a "why") regarding the nature of the underlying physical cause of the event.

Seaman, Rob↗

Observation of Undulator Radiation Generated by a Single Electron Circulating in a Storage Ring and Possible Applications

An experimental study into the undulator radiation, generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The individual photons were detected by a Single Photon Avalanche Diode (SPAD) at an average rate of 1 detection per 300 revolutions in the ring. The detection events were continuously recorded by a picosecond event timer for as long as 1 minute at a time. The collected data were used to test if there is any deviation from the classically predicted Poissonian photostatistics. It was motivated by the observation * of sub-Poissonian statistics in a similar experiment. The observation * could be an instrumentation effect related to low detection efficiency and long detector dead time. In our experiment, the detector (SPAD) has a much higher efficiency (65%) and a much lower dead time. In addition, we show that the collected data (recorded detection times) can be used to study the synchrotron motion of a single electron and infer some parameters of the ring. For example, by comparing the results of simulation and measurement for the synchrotron motion we were able to estimate the magnitude of the RF phase jitter.

43 PARTICLE ACCELERATORS↗

Classification of Dust Days by Satellite Remotely Sensed Aerosol Products

Considerable progress in satellite remote sensing (SRS) of dust particles has been seen in the last decade. From an environmental health perspective, such an event detection, after linking it to ground particulate matter (PM) concentrations, can proxy acute exposure to respirable particles of certain properties (i.e. size, composition, and toxicity). Being affected considerably by atmospheric dust, previous studies in the Eastern Mediterranean, and in Israel in particular, have focused on mechanistic and synoptic prediction, classification, and characterization of dust events. In particular, a scheme for identifying dust days (DD) in Israel based on ground PM10 (particulate matter of size smaller than 10 nm) measurements has been suggested, which has been validated by compositional analysis. This scheme requires information regarding ground PM10 levels, which is naturally limited in places with sparse ground-monitoring coverage. In such cases, SRS may be an efficient and cost-effective alternative to ground measurements. This work demonstrates a new model for identifying DD and non-DD (NDD) over Israel based on an integration of aerosol products from different satellite platforms (Moderate Resolution Imaging Spectroradiometer (MODIS) and Ozone Monitoring Instrument (OMI)). Analysis of ground-monitoring data from 2007 to 2008 in southern Israel revealed 67 DD, with more than 88 percent occurring during winter and spring. A Classification and Regression Tree (CART) model that was applied to a database containing ground monitoring (the dependent variable) and SRS aerosol product (the independent variables) records revealed an optimal set of binary variables for the identification of DD. These variables are combinations of the following primary variables: the calendar month, ground-level relative humidity (RH), the aerosol optical depth (AOD) from MODIS, and the aerosol absorbing index (AAI) from OMI. A logistic regression that uses these variables, coded as binary variables, demonstrated 93.2 percent correct classifications of DD and NDD. Evaluation of the combined CART-logistic regression scheme in an adjacent geographical region (Gush Dan) demonstrated good results. Using SRS aerosol products for DD and NDD, identification may enable us to distinguish between health, ecological, and environmental effects that result from exposure to these distinct particle populations.

satellite remote sensing↗

Analysis Methods and Results for Weak Gamma-Ray Bursts in the BATSE Data

We report initial results on the statistical properties of the dimmest gamma-ray bursts (GRBs) observed with the Burst and Transient Source Experiment (BATSE), using new ground-based methods to obtain a sample of GRBs from 502 days of BATSE data. Using the most sensitive ground-based detection of GRBs, the sample extends to GRBs much fainter than those detected by the on-board trigger, but because of the temporal resolution of the data, the sample is limited to GRBs of duration of at least 2(approx.)s. For each detected event, Bayesian probabilities are calculated for the event to belong to each of seven classes of differing physical origins. The sample of GRB candidates is defined by the requirement that the Bayesian probability for belonging to the GRB class is higher than 0.5. The intensity distribution of the GRB sample is corrected using a Monte Carlo simulation of the post-flight detection efficiency. The dimmest BATSE bursts of the sample continue the hardness-intensity trend seen in brighter GREs and are consistent with isotropy.

Mitrofanov, I. G.↗

A computer aided treatment event recognition system in radiation therapy

Purpose: To develop an automated system to safeguard radiation therapy treatments by analyzing electronic treatment records and reporting treatment events. Methods: CATERS (Computer Aided Treatment Event Recognition System) was developed to detect treatment events by retrieving and analyzing electronic treatment records. CATERS is designed to make the treatment monitoring process more efficient by automating the search of the electronic record for possible deviations from physician's intention, such as logical inconsistencies as well as aberrant treatment parameters (e.g., beam energy, dose, table position, prescription change, treatment overrides, etc). Over a 5 month period (July 2012–November 2012), physicists were assisted by the CATERS software in conducting normal weekly chart checks with the aims of (a) determining the relative frequency of particular events in the authors’ clinic and (b) incorporating these checks into the CATERS. During this study period, 491 patients were treated at the University of Iowa Hospitals and Clinics for a total of 7692 fractions. Results: All treatment records from the 5 month analysis period were evaluated using all the checks incorporated into CATERS after the training period. About 553 events were detected as being exceptions, although none of them had significant dosimetric impact on patient treatments. These events included every known event type that was discovered during the trial period. A frequency analysis of the events showed that the top three types of detected events were couch position override (3.2%), extra cone beam imaging (1.85%), and significant couch position deviation (1.31%). The significant couch deviation is defined as the number of treatments where couch vertical exceeded two times standard deviation of all couch verticals, or couch lateral/longitudinal exceeded three times standard deviation of all couch laterals and longitudinals. On average, the application takes about 1 s per patient when executed on either a desktop computer or a mobile device. Conclusions: CATERS offers an effective tool to detect and report treatment events. Automation and rapid processing enables electronic record interrogation daily, alerting the medical physicist of deviations potentially days prior to performing weekly check. The output of CATERS could also be utilized as an important input to failure mode and effects analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FPGA-based gating and logic for multichannel single photon counting

We present results characterizing multichannel InGaAs single photon detectors utilizing gated passive quenching circuits (GPQC), self-differencing techniques, and field programmable gate array (FPGA)-based logic for both diode gating and coincidence counting. Utilizing FPGAs for the diode gating frontend and the logic counting backend has the advantage of low cost compared to custom built logic circuits and current off-the-shelf detector technology. Further, FPGA logic counters have been shown to work well in quantum key distribution (QKD) test beds. Our setup combines multiple independent detector channels in a reconfigurable manner via an FPGA backend and post processing in order to perform coincidence measurements between any two or more detector channels simultaneously. Using this method, states from a multi-photon polarization entangled source are detected and characterized via coincidence counting on the FPGA. Photons detection events are also processed by the quantum information toolkit for application testing (QITKAT)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino emission from the direction of the blazar TXS 0506+056 prior to the IceCube-170922A alert

A high-energy neutrino event detected by IceCube on 22 September 2017 was coincident in direction and time with a gamma-ray flare from the blazar TXS 0506+056. Prompted by this association, we investigated 9.5 years of IceCube neutrino observations to search for excess emission at the position of the blazar. We found an excess of high-energy neutrino events, with respect to atmospheric backgrounds, at that position between September 2014 and March 2015. Allowing for time-variable flux, this constitutes 3.5σ evidence for neutrino emission from the direction of TXS 0506+056, independent of and prior to the 2017 flaring episode. This suggests that blazars are identifiable sources of the high-energy astrophysical neutrino flux.

Science & Technology - Other Topics↗

First operation of undoped CsI directly coupled with SiPMs at 77 K

Abstract The light yield of a small undoped cesium iodide (CsI) crystal directly coupled with two silicon photomultipliers (SiPMs) at about 77 Kelvin was measured to be $$43.0 \pm 1.1$$ 43.0 ± 1.1 photoelectrons (PE) per keV electron-equivalent (keV $$_\text {ee}$$ ee ) using X and $$\gamma $$ γ -ray peaks from an $$^{241}$$ 241 Am radioactive source from 18 to 60 keV. The high light yield together with some other technical advantages illustrate the great potential of this novel combination for neutrino and low-mass dark matter detection, particularly at accelerator-based neutrino sources, where random background can be highly suppressed by requiring coincident triggers between SiPMs and beam pulse timing signals. Some potential drawbacks of using cryogenic SiPMs instead of photomultiplier tubes (PMTs) were identified, such as worse energy resolution and optical cross-talks between SiPMs. Their influence to rare-event detection was discussed and possible solutions were provided.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A flare event of the long-period RS Canum Venaticorum system IM Pegasi

The characteristics of a flare event detected on the long-period RS CVn system IM Pegasi are reported. The low-resolution spectrum show enhancements of up to a factor of five in some emission lines. All of the ultraviolet emission lines normally visible are enhanced significantly more than the normal 30 rotational modulation. Emission fluxes of both the quiescent and flare event are used to construct models of the density and temperature variation with height. These models reveal a downward shift of the transition region during the flare. Scaled models of the quiet and flaring solar outer atmosphere are used to estimate the filling factor of the flare event at about 30 percent of the stellar surface. The pattern of line enhancements in the flare is the same as a previous event in Lambda Andromeda observed previously.

Buzasi, Derek L.↗

Contemporary Toxicity Profile of Breast Brachytherapy Versus External Beam Radiation After Lumpectomy for Breast Cancer

Purpose: We compared toxicities after brachytherapy versus external beam radiation therapy (EBRT) in contemporary breast cancer patients. Methods and Materials: Using MarketScan healthcare claims, we identified 64,112 women treated from 2003 to 2012 with lumpectomy followed by radiation (brachytherapy vs EBRT). Brachytherapy was further classified by multichannel versus single-channel applicator approach. We identified the risks and predictors of 1-year infectious and noninfectious postoperative adverse events using logistic regression and temporal trends using Cochran-Armitage tests. We estimated the 5-year Kaplan-Meier cumulative incidence of radiation-associated adverse events. Results: A total of 4522 (7.1%) patients received brachytherapy (50.2% multichannel vs 48.7% single-channel applicator). The overall risk of infectious adverse events was higher after brachytherapy than after EBRT (odds ratio [OR] = 1.21; 95% confidence interval [CI] 1.09-1.34, P<.001). However, over time, the frequency of infectious adverse events after brachytherapy decreased, from 17.3% in 2003 to 11.6% in 2012, and was stable after EBRT at 9.7%. Beyond 2007, there were no longer excess infections with brachytherapy (P=.97). The overall risk of noninfectious adverse events was higher after brachytherapy than after EBRT (OR=2.27; 95% CI 2.09-2.47, P<.0001). Over time, the frequency of noninfectious adverse events detected increased: after multichannel brachytherapy, from 9.1% in 2004 to 18.9% in 2012 (Ptrend = .64); single-channel brachytherapy, from 12.8% to 29.8% (Ptrend<.001); and EBRT, from 6.1% to 10.3% (Ptrend<.0001). The risk was significantly higher with single-channel than with multichannel brachytherapy (hazard ratio = 1.32; 95% CI 1.03-1.69, P=.03). Of noninfectious adverse events, 70.9% were seroma. Seroma significantly increased breast pain risk (P<.0001). Patients with underlying diabetes, cardiovascular disease, and treatment with chemotherapy had increased infectious and noninfectious adverse events. The 5-year incidences of fat necrosis, breast pain, and rib fracture were slightly higher after brachytherapy than after EBRT (13.7% vs 8.1%, 19.4% vs 16.0%, and 1.6% vs 1.3%, respectively), but the risks were not significantly different for multichannel versus single-channel applicators. Conclusion: Toxicities after breast brachytherapy were distinct from those after EBRT. Temporal toxicity trends may reflect changing technology and evolving practitioner experience with brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Case study of a low-reflectivity pulsating microburst - Numerical simulation of the Denver, 8 July 1989, storm

An intense, low-reflectivity, and pulsating microburst event, detected on July 8, 1989 by the Low-Level Windshear Alert System north of Denver Stapleton Airport is described using a Terminal Area Simulation System (TASS) model (Proctor, 1987). This 3d nonhydrostatic cloud model includes parametrizations for both liquid- and ice-phase microphysics. Simulation results show that the dissipating cloud induces a type-1 pulsating microburst event, with at least three distinct microburst pulses over a period of 20 min. Virga from the dissipating cloud continued to maintain hazardous windshear for a period much longer than the typical lifetime of a single microburst.

Proctor, Fred H.↗

The Destruction and Recreation of the X-Ray Corona in a Changing-look Active Galactic Nucleus

We present the drastic transformation of the X-ray properties of the active galactic nucleus 1ES 1927+654, following a changing-look event. After the optical/UV outburst the power-law component, produced in the X-ray corona, disappeared, and the spectrum of 1ES 1927+65 instead became dominated by a blackbody component (kT ∼ 80− 120 eV). This implies that the X-ray corona, ubiquitously found in AGN, was destroyed in the event. Our dense ∼ 450 day long X-ray monitoring shows that the source is extremely variable in the X-ray band. On long time scales the source varies up to ∼ 4 dex in ∼ 100 days, while on short timescales up to ∼ 2 dex in ∼ 8 hours. The luminosity of the source is found to first show a strong dip down to ∼ 10(exp 40) erg/s, and then a constant increase in luminosity to levels exceeding the pre-outburst level &300 days after the optical event detection, rising up asymptotically to ∼ 2 × 10(exp 44) erg/s. As the X-ray luminosity of the source increases, the X-ray corona is recreated, and a very steep power-law component (Γ ≃ 3) reappears, and dominates the emission for 0.3–2 keV luminosities & 10(exp 43.7) erg/s, ∼ 300 days after the beginning of the event. We discuss possible origins of this event, and speculate that our observations could be explained by the interaction between the accretion flow and debris from a tidally disrupted star. Our results show that changing-look events can be associated with dramatic and rapid transformations of the innermost regions of accreting SMBHs.

C. Ricci↗

OBSERVATION OF DIFFUSE COSMIC AND ATMOSPHERIC GAMMA RAYS AT BALLOON ALTITUDES WITH AN ELECTRON-TRACKING COMPTON CAMERA

We observed diffuse cosmic and atmospheric gamma rays at balloon altitudes with the Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I (SMILE-I) as the first step toward a future all-sky survey with a high sensitivity. SMILE-I employed an electron-tracking Compton camera comprised of a gaseous electron tracker as a Compton-scattering target and a scintillation camera as an absorber. The balloon carrying the SMILE-I detector was launched from the Sanriku Balloon Center of the Institute of Space and Astronautical Science/Japan Aerospace Exploration Agency on 2006 September 1, and the flight lasted for 6.8 hr, including level flight for 4.1 hr at an altitude of 32-35 km. During the level flight, we successfully detected 420 downward gamma rays between 100 keV and 1 MeV at zenith angles below 60 deg. To obtain the flux of diffuse cosmic gamma rays, we first simulated their scattering in the atmosphere using Geant4, and for gamma rays detected at an atmospheric depth of 7.0 g cm{sup -2} we found that 50% and 21% of the gamma rays at energies of 150 keV and 1 MeV, respectively, were scattered in the atmosphere prior to reaching the detector. Moreover, by using Geant4 simulations and the QinetiQ atmospheric radiation model, we estimated that the detected events consisted of diffuse cosmic and atmospheric gamma rays (79%), secondary photons produced in the instrument through the interaction between cosmic rays and materials surrounding the detector (19%), and other particles (2%). The obtained growth curve was comparable to Ling's model, and the fluxes of diffuse cosmic and atmospheric gamma rays were consistent with the results of previous experiments. The expected detection sensitivity of a future SMILE experiment measuring gamma rays between 150 keV and 20 MeV was estimated from our SMILE-I results and was found to be 10 times better than that of other experiments at around 1 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

2012 Geothermal Technologies Peer Review Summary: Mapping Diffuse Seismicity

The purpose of this project as it relates to GTP goals is to create a methodology that can be successfully implemented at an EGS site to aid in the successful creation of an EGS reservoir. The MFP technique would allow developers to obtain better seismic information for input when characterizing the hazard and risk associated with induced seismic events and when creating and monitoring the EGS reservoir. The purpose of this project as it relates to the geothermal industry / market is to create a method by which certain recommendations within the 2012 Protocol for Addressing Induced Seismicity Associated with Enhanced Geothermal Systems can be more easily implemented. The particular recommendation referred to is that seismic instrumentation should be able to detect events at least as small as M1.0 and preferably down to M0.0. This technique has been shown to decrease the magnitude completeness threshold of existing seismic networks, and as such should positively impact implementation of the above recommendation.

15 GEOTHERMAL ENERGY↗

Study of cosmic dust particles on board LDEF: The FRECOPA experiments AO138-1 and AO138-2

Two experiments, within the French Cooperative Payload (FRECOPA) and devoted to the detection of cosmic dust, were flown on the LDEF. A variety of sensors and collecting devices have made possible the study of impact processes on materials of technological interest. Preliminary examination of hypervelocity impact features gives valuable data on size distribution and nature of interplanetary dust particles in low earth orbit, within the 0.5 to 300 micrometer size range. Most of the events detected on the trailing face of LDEF are expected to be the result of impacts of meteoritic particles only. So far, chemical analysis of craters by EDS clearly shows evidence of elements (Na, Mg, Si, S, Ca, and Fe) consistent with cosmic origin. Systematic occurrence of C and O in crater residues is an important result, to be compared with the existence of CHON particles detected in P-Halley comet nucleus. Crater size distribution is in good agreement with results from other dust experiments flown on LDEF. However, no crater smaller than 1.5 micron was observed, thus suggesting a cutoff in the near earth particle distribution. Possible origin and orbital evolution of micrometeoroids is discussed.

Mandeville, J. C.↗

Data-driven estimation of the invisible energy of cosmic ray showers with the Pierre Auger Observatory

The determination of the primary energy of extensive air showers using the fluorescence detection technique requires an estimation of the energy carried away by particles that do not deposit all their energy in the atmosphere. This estimation is typically made using Monte Carlo simulations and thus depends on the assumed primary particle mass and on model predictions for neutrino and muon production. In this work we present a new method to obtain the invisible energy from events detected by the Pierre Auger Observatory. Here, the method uses measurements of the muon number at ground level, and it allows us to reduce significantly the systematic uncertainties related to the mass composition and the high energy hadronic interaction models, and consequently to improve the estimation of the energy scale of the Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗