Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW, SUPERSONIC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

LV software for supersonic flow analysis

The NASA Lewis Research Center (LeRC) maintains a leadership position in research into advanced aerospace propulsion systems. For the next generation of aircraft, engine designs continue to involve complex, high-speed flows. Performing the detailed flow diagnostics to properly evaluate these designs requires advanced instrumentation to probe these highly turbulent flows. The hostile flow environment often requires nonintrusive measurement techniques such as the laser velocimeter (LV). Since the LV is a proven instrument for nonintrusive flow measurement, it can provide quantitative velocity data with minimal interference to the flow. Based on anticipated flow conditions, laser velocimeter systems were procured from TSI, Inc. The initial system utilized counter processor technology, but later procurements this past year include a more advanced, correlator-based processor, which significantly improves the overall LV performance. To meet the needs of advanced research into propulsion, this instrument must be integrated into an existing VAX/VMS computer system for data acquisition, processing, and presentation. The work done under this grant before this period concentrated on developing the software required to setup and acquire data from the TSI MI-990 multichannel interface, and the RMR 1989 rotating machinery resolver. With the basis established for controlling the operation of the LV system, software development this past year shifted in emphasis from instrumentation control and data acquisition to data analysis and presentation. The progress of the program is reported.

Bell, William A.↗

LV software support for supersonic flow analysis

The software for configuring a Laser Velocimeter (LV) counter processor system was developed using structured design. The LV system includes up to three counter processors and a rotary encoder. The software for configuring and testing the LV system was developed, tested, and included in an overall software package for data acquisition, analysis, and reduction. Error handling routines respond to both operator and instrument errors which often arise in the course of measuring complex, high-speed flows. The use of networking capabilities greatly facilitates the software development process by allowing software development and testing from a remote site. In addition, high-speed transfers allow graphics files or commands to provide viewing of the data from a remote site. Further advances in data analysis require corresponding advances in procedures for statistical and time series analysis of nonuniformly sampled data.

Bell, William A.↗

Measurements of density, temperature, and their fluctuations in turbulent supersonic flow using UV laser spectroscopy

Nonintrusive measurements of density, temperature, and their turbulent fluctuation levels were obtained in the boundary layer of an unseeded, Mach 2 wind tunnel flow. The spectroscopic technique that was used to make the measurements is based on the combination of laser-induced oxygen fluorescence and Raman scattering by oxygen and nitrogen from the same laser pulse. Results from this demonstration experiment are compared with previous measurements obtained in the same facility using conventional probes and an earlier spectroscopic technique. Densities and temperatures measured with the current technique agree with the previous surveys to within 3 percent and 2 percent, respectively. The fluctuation amplitudes for both variables agree with the measurements obtained using the earlier spectroscopic technique and show evidence of an unsteady, weak shock wave that perturbs the boundary layer.

Fletcher, Douglas G.↗

A hybrid multigrid technique for computing steady-state solutions to supersonic flows

Recently, Li and Sanders have introduced a class of finite difference schemes to approximate generally discontinuous solutions to hyperbolic systems of conservation laws. These equations have the form together with relevant boundary conditions. When modelling hypersonic spacecraft reentry, the differential equations above are frequently given by the compressible Euler equations coupled with a nonequilibrium chemistry model. For these applications, steady state solutions are often sought. Many tens (to hundreds) of super computer hours can be devoted to a single three space dimensional simulation. The primary difficulty is the inability to rapidly and reliably capture the steady state. In these notes, we demonstrate that a particular variant from the schemes presented can be combined with a particular multigrid approach to capture steady state solutions to the compressible Euler equations in one space dimension. We show that the rate of convergence to steady state coming from this multigrid implementation is vastly superior to the traditional approach of artificial time relaxation. Moreover, we demonstrate virtual grid independence. That is, the rate of convergence does not depend on the degree of spatial grid refinement.

Sanders, Richard↗

Single-pulse measurement of density and temperature in a turbulent, supersonic flow using UV laser spectroscopy

Nonintrusive measurements of density and temperature and their turbulent fluctuation levels have been obtained in the boundary layer of an unseeded, Mach 2 wind tunnel flow. The spectroscopic technique that was used to make the measurements is based on the combination of laser-induced oxygen fluorescence and Raman scattering by oxygen and nitrogen from the same laser pulse. Results from this demonstration experiment compare favorably with previous measurements obtained in the same facility from conventional probes and an earlier spectroscopic technique.

Fletcher, D. G.↗

LV software support for supersonic flow analysis

The software for configuring an LV counter processor system has been developed using structured design. The LV system includes up to three counter processors and a rotary encoder. The software for configuring and testing the LV system has been developed, tested, and included in an overall software package for data acquisition, analysis, and reduction. Error handling routines respond to both operator and instrument errors which often arise in the course of measuring complex, high-speed flows. The use of networking capabilities greatly facilitates the software development process by allowing software development and testing from a remote site. In addition, high-speed transfers allow graphics files or commands to provide viewing of the data from a remote site. Further advances in data analysis require corresponding advances in procedures for statistical and time series analysis of nonuniformly sampled data.

Bell, W. A.↗

A high-order compact numerical algorithm for supersonic flows

A dissipative compact two-four scheme (second-order time, fourth-order space) similar to the original MacCormack scheme has been developed, that exhibits greater accuracy than conventional fourth-order schemes. The dissipative nature of the scheme allows it to resolve weak discontinuities without artificial damping. A derivation of the scheme is presented, as well as the theoretical stability characteristics. The temporal scheme is then generalized into a steady-state formulation which achieves fourth-order spatial accuracy at steady-state. Several test problems are used to show that the scheme is more accurate than the traditional MacCormack scheme, and is nearly as efficient.

Carpenter, M. H.↗

Near-field supersonic flow predictions by an adaptive unstructured tetrahedral grid solver

Applicability of a three-dimensional solution adaptive unstructured tetrahedral Euler flow solver about generic models for near-field sonic boom pressure signature predictions is evaluated. Comparisons of computational and experimental data demonstrates the capability of the method for predicting inviscid solutions useful for high speed calculations about simple 3-D geometries. The approach has promising features and results indicate potential for application to more complex configurations. The mesh generation is based on the advancing front technique, and steady state solutions of the Euler equations are achieved by explicit time integration. Spatial discretization uses the Taylor-Galerkin approach; an alternate time integration, based on the Runge-Kutta method, is also included. The solution-adaptive grid procedure is based on either remeshing or mesh refinement techniques. An alternative geometry-adaptive grid procedure has also been incorporated.

Djomehri, M. J.↗

A numerical analysis of supersonic flow over an axisymmetric afterbody

The performance of a pressure-based algorithm and the k-epsilon type turbulence models, including the original formulation proposed by Jones and Launder (1972), model extensions for refined treatment of time scales, and model corrections developed for treating compressible flows is assessed by analyzing the near-wake region of a Mach 2.5 flow over an axisymmetric cylindrical afterbody. The mechanisms responsible for the different levels of performance of the various turbulence models for the flow are investigated. It is shown that the k-epsilon models extended to allow for better response to the mean strain rate and corrected for compressibility result in better flowfield predictions than the original k-epsilon model.

Tucker, P. K.↗