Search NASA⌕ Search

SEARCH · Search NASA

Results for “FOILS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Foil seal Patent

Fluid seal formed by flexible disk on rotating shaft to retain lubricating oils around shaft

Ludwig, L. P.↗

Unsteady radiant heating of conical foil receptors.

The time dependent thermal equations of two types of conical radiation detectors are discussed and solved for a step function application of radiation parallel to the axis of the cases. The first type has a heat sink at the base and the second has the vertex buried in a heat sink to a variable proportion of its total height. It is found that the first case has the lower sensitivity and better time response. The time response of the second case is improved by more deeply burying the vertex, but to the detriment of sensitivity. At no value of this inclusion can both a superior sensitivity and time response be achieved for the second case.

Saunders, R. C., Jr.↗

Mini-BRU/BIPS foil bearing development

The analysis revealed the failure agent to be a combination of poor teflon coating adhesion, a decrease in bearing sway space and, possibly, lack of flushing flow through the bearing. A change in Teflon coating vendors provided substantially improved coating quality and surface finish. The sway space was increased and the cooling bleed flow was adjusted to flush the bearing. These changes were included in a test conducted in the WHL from 6 April to 22 May 1978 which resulted in the completion of 1006.9 hours of operation at temperature and load. Post-test inspection revealed the bearings to be in excellent condition and capable of completing a much longer test.

Dobler, F. X.↗

High temperature self-lubricating coatings for air lubricated foil bearings for the automotive gas turbine engine

coating combinations were developed for compliant surface bearings and journals to be used in an automotive gas turbine engine. The coatings were able to withstand the sliding start/stops during rotor liftoff and touchdown and occasional short time, high speed rubs under representative loading of the engine. Some dozen coating variations of CdO-graphite, Cr2O3 (by sputtering) and CaF2 (plasma sprayed) were identified. The coatings were optimized and they were examined for stoichiometry, metallurgical condition, and adhesion. Sputtered Cr2O3 was most adherent when optimum parameters were used and it was applied on an annealed (soft) substrate. Metallic binders and interlayers were used to improve the ductility and the adherence.

Bhushan, B.↗

Multiple-path fission-foil nuclear lasing of Ar-Xe

Nuclear lasing of Ar 10% Xe at 760 torr with a thermal neutron flux of 3.5 x 10 to the 16th n/sq cm s has produced an output power of 50 W. Lasing occurred at 2.6 microns in Xe-I. The argon buffer gas is shown to efficiently stop fission fragments at reasonable pressures emitted from (U-235)3O8 coatings. A unique folded optical path was used to increase the excited gas volume which in turn increases laser output.

De Young, R. J.↗

Thin foil silicon solar cells with coplanar back contacts

To fabricate 50 microns thick, coplanar back contact (CBC) silicon solar cells, wraparound junction design was selected and proved to be effective. The process sequence used, the cell design, and the cell performance are described. CBC cells with low solar absorptance have shown AMO efficiencies to 13%, high cells up to 14%; further improvements are projected with predictable optimization.

Ho, F.↗

Wind tunnel evaluation of air-foil performance using simulated ice shapes

A two-phase wind tunnel test was conducted in the 6 by 9 foot Icing Research Tunnel (IRT) at NASA Lewis Research Center to evaluate the effect of ice on the performance of a full scale general aviation wing. In the first IRT tests, rime and glaze shapes were carefully documented as functions of angle of attack and free stream conditions. Next, simulated ice shapes were constructed for two rime and two glaze shapes and used in the second IRT tunnel entry. The ice shapes and the clean airfoil were tapped to obtain surface pressures and a probe used to measure the wake characteristics. These data were recorded and processed, on-line, with a minicomputer/digital data acquisition system. The effect of both rime and glaze ice on the pressure distribution, Cl, Cd, and Cm are presented.

Bragg, M. B.↗

Resistance-foil strain-gage technology as applied to composite materials

A general review of existing strain-gage technologies as applied to orthotropic-composite materials is given. The specific topics addressed are gage-bonding procedures, transverse-sensitivity effects, errors due to gage misalignment, and temperature-compensation methods. The discussion is supplemented by numerical examples where appropriate. It is shown that the orthotropic behavior of composites can result in experimental error which would not be expected based on practical experience with isotropic materials. In certain cases, the transverse sensitivity of strain gages and/or slight gage misalignment can result in strain-measurement errors exceeding 50 percent.

Tuttle, M. E.↗

An experimental evaluation of apparent strain from foil strain gauges attached to carbon composite substrates

An experimental evaluation of apparent thermal strains is conducted using various combinations of substrate/gauge/attachment structure and redundant high temperature extensometry. It is found that the extensometry could either confirm independent measurements of the substrate's thermal expansion, or quantify nonzero mechanical strains resulting from uncertain material behavior and boundary conditions. Apparent strain and thermal expansion behavior data can then be used to modify the raw strain measurements in order to determine either stress producing or total strains. Limitation of the correction procedure for the three selected strain gauges is noted which is due to relatively large gauge/attachment variability.

Scott, B. R.↗

Conical foil X-ray mirrors - Performance and projections

The design, fabrication, and performance of conical grazing incidence mirrors designed to increase the sensitivity and resolution of observations in the iron K spectral band around 7 KeV are discussed. The present mirrors consist of two adjacent, coaxial and confocal arrays of tightly packed fixed-length cones. Heat treatment is used to minimize distortions in forming the cones. Reflector assembly is simplified by changing from rectangular reflector support slots to tapered ones. An image-blur of only 1.3 arcmin half-power radius has been achieved, in addition to X-ray reflectivity in the 1.5-10 keV range at about the 90 percent level of theoretical values.

Serlemitsos, Peter J.↗

Use of piezoelectric foil for flow diagnostics

A laboratory investigation was conducted to characterize two piezoelectric-film sensor configurations, a rigidly mounted sensor and a sensor mounted over an air cavity. The sensors are evaluated for sensitivity and frequency response, and methods to optimize data are presented. The cavity-mounted sensor exhibited a superior frequency response and was more sensitive to normal pressure fluctuations and less sensitive to vibrations through the structure. Both configurations were sensitive to large-scale structural vibrations. Flight-test data are shown for cavity-mounted sensors, illustrating practical aspects to consider when designing sensors for application in such harsh environments. The relation of the data to skin friction and maximum shear stress, transition detection, and turbulent viscous layers is derived through analysis of the flight data.

Carraway, Debra L.↗

Recent experience with elevated-temperature foil strain gages with application to thin-gage materials

The effects of thin-gage materials on high-temperature strain measurements are discussed. Apparent strain test were performed using facesheet coupons, honeycomb coupons, and the panel with strain gages in an installed condition. The apparent strain results differed in each of the cases. The apparent strain curves from the panel tests are expected to provide the best correlation with analysis, assuming that the thermal strains are insignificant or that the thermal strains derived from the analysis of the apparent strain test performed on the panel can be used to correct the apparent strain curves.

Hudson, Larry D.↗

Sensitivity of LDEF foil analyses using ultra-low background germanium versus large NaI(T1) multidimensional spectrometers

Cobalt samples were analyzed for cosmic ray induced Co-60 with both an ultralow background germanium gamma ray spectrometer and with a large NaI(T1) multidimensional spectrometer using electronic anticoincidence shielding. Aluminum samples were analyzed for Na-22. The results are presented along with the relative sensitivities and precision afforded by the two methods.

Reeves, James H.↗