Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fast Fourier transform”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Measurement of human pilot dynamic characteristics in flight simulation

Fast Fourier Transform (FFT) and Least Square Error (LSE) estimation techniques were applied to the problem of identifying pilot-vehicle dynamic characteristics in flight simulation. A brief investigation of the effects of noise, input bandwidth and system delay upon the FFT and LSE techniques was undertaken using synthetic data. Data from a piloted simulation conducted at NASA Ames Research Center was then analyzed. The simulation was performed in the NASA Ames Research Center Variable Stability CH-47B helicopter operating in fixed-basis simulator mode. The piloting task consisted of maintaining the simulated vehicle over a moving hover pad whose motion was described by a random-appearing sum of sinusoids. The two test subjects used a head-down, color cathode ray tube (CRT) display for guidance and control information. Test configurations differed in the number of axes being controlled by the pilot (longitudinal only versus longitudinal and lateral), and in the presence or absence of an important display indicator called an 'acceleration ball'. A number of different pilot-vehicle transfer functions were measured, and where appropriate, qualitatively compared with theoretical pilot- vehicle models. Some indirect evidence suggesting pursuit behavior on the part of the test subjects is discussed.

Reedy, James T.↗

Dynamic Stability Instrumentation System (DSIS): User Manual - Volume 3

The paper is an operating manual for the Dynamic Stability Instrumentation System in specific NASA Langley wind tunnels. The instrumentation system performs either a synchronous demodulation or a Fast Fourier Transform on dynamic balance strain gage signals, and ultimately computes aerodynamic coefficients. The dynamic balance converts sting motor rotation into pitch or yaw plane or roll axis oscillation, with timing information provided by a shaft encoder. Additional instruments control model attitude and balance temperature and monitor sting vibrations. Other instruments perform self-calibration and diagnostics. Procedures for conducting calibrations and wind-off and wind-on tests are listed.

Daniels, Taumi S.↗

A SETI Search of Nearby Solar-Type Stars at the 203-GHz Positronium Hyperfine Resonance

The development of advanced millimeter-wave technology has made it possible to construct low-noise receivers and high-power transmitters comparable to those available at much lower frequencies. This technology, plus certain physical characteristics of the millimeter-wave spectrum, suggests possible advantages for use of this wavelength range for interstellar communications. As a result, a Search for ExtraTerrestrial Intelligence(SETI) type search has been conducted for narrow-bandwidth signals at frequencies near the positronium hyperfine spectral line (203.385 GHz), a potential natural reference frequency. A total of 40 solar-type stars within 23 parsecs were observed, in addition to three locations near the galactic center. No detections were made at the detection threshold of 2.3 x 10(exp -19) W/sq m in each of two orthogonal linear polarizations Future observations will be made with a higher resolution Fast Fourier Transform Spectrum Analyzer (FFTSA), which should improve sensitivity by an order of magnitude and reduce required observing time.

Steffes, Paul G.↗

Direct Numerical Simulation of a Temporally Evolving Incompressible Plane Wake: Effect of Initial Conditions on Evolution and Topology

Direct numerical simulations have been used to examine the effect of the initial disturbance field on the development of three-dimensionality and the transition to turbulence in the incompressible plane wake. The simulations were performed using a new numerical method for solving the time-dependent, three-dimensional, incompressible Navier-Stokes equations in flows with one infinite and two periodic directions. The method uses standard Fast Fourier Transforms and is applicable to cases where the vorticity field is compact in the infinite direction. Initial disturbances fields examined were combinations of two-dimensional waves and symmetric pairs of 60 deg oblique waves at the fundamental, subharmonic, and sub-subharmonic wavelengths. The results of these simulations indicate that the presence of 60 deg disturbances at the subharmonic streamwise wavelength results in the development of strong coherent three-dimensional structures. The resulting strong three-dimensional rate-of-strain triggers the growth of intense fine scale motions. Wakes initiated with 60 deg disturbances at the fundamental streamwise wavelength develop weak coherent streamwise structures, and do not develop significant fine scale motions, even at high Reynolds numbers. The wakes which develop strong three-dimensional structures exhibit growth rates on par with experimentally observed turbulent plane wakes. Wakes which develop only weak three-dimensional structures exhibit significantly lower late time growth rates. Preliminary studies of wakes initiated with an oblique fundamental and a two-dimensional subharmonic, which develop asymmetric coherent oblique structures at the subharmonic wavelength, indicate that significant fine scale motions only develop if the resulting oblique structures are above an angle of approximately 45 deg.

Sondergaard, R.↗

Apparatus and Method for Determining the Mass Density of a Filament

A method and apparatus for determining the mass density of a moving filament is provided. The method includes the steps of providing a filament across two supports, tensioning the filament. inducing a vibration into the filament segment between the supports, reinforcing the vibration using an amplified feedback signal, detecting the vibrational frequency data. processing the data using a fast-fourier transform analysis. and then displaying the frequency. The use of the feedback signal results in a self-tuning resonant loop. Open loop versions may also be used. The apparatus includes a base supporting a fixed support and a transducer which in turn supports a moveable support. The transducer vibrates the moveable support transversely to the direction of travel of the filament, thereby inducing a transverse vibrational mode. The output of the transducer is amplified and used to drive a second amplifier to produce a self-tuning resonant loop. In the open loop version a signal generator is used to drive the transducer through a frequency range, during which the amplitude peak is identified.

Hinkley, Jeffrey A.↗

Registration assisted mosaic generation

This paper presents a general strategy for assembling mosaics from numerous individual images where uncertainty exists in the position and orientation of those images. Both of the presented applications relate to remotely operated camera platforms, the first being the Galileo solid state imaging (SSI) camera presently in orbit around Jupiter, and the second being the Imager for Mars Pathfinder (IMP) stereo camera on Mars. A basic strategy in both applications is to determine the correct relative camera pointing followed by direct map projection of the images. It is assumed that approximate camera pointing exists sufficient to locate adjacent images and to place initial tiepoints within reach of the correlator. Spatial correlation is used to fix tiepoints whose initial locations are predicted by the camera pointing. We use either an fast fourier transform (fft) algorithm or a variant of Gruen's scheme permitting limited image rotation and skew. The Gruen correlator has three hierarchical modes: 1) A classical spatial least squares correlation on integral pixel boundaries used when rotation is small. 2) An annealing non-deterministic search used when rotations are unknown. A simplex deterministic search used for the end game. The correlation operation can be performed either interactively or autonomously. The final camera pointing solution relies upon a simplex downhill search in 2n or 3n dimensions where n is the number of images comprising the mosaic and the objective function to be minimized is the disagreement between tiepoint locations predicted from the camera pointing with those observed by the correlator. For Galileo the 3n unknowns are euler angles defining camera pointing in planet coordinates, and for Mars Pathfinder they are 2n unknowns representing commanded azimuth and elevation in the Lander coordinate system.

Lorre, Jean J.↗

Fast Nitrogen Atoms from Dissociative Excitation of N2 by Electron Impact

The Doppler profiles of one of the fine structure lines of the N I (1200 A) g (sup 4)S(sup 0)-(sup 4)P multiplet and of the N II (1085 A) g (sup 3)p(sup O)-(sup 3)D multiplet have been measured. Excitation of the multiplets is produced by electron impact dissociative excitation of N2. The experimental line profiles are evaluated by fast Fourier transform (FFT) techniques and analysis of the profiles yields the kinetic energy distribution of fragments. The full width at half maximum (FWHM) of N I (1200 A) increases from 27+/-6 mA at 30 eV to 37+/-4 mA at 100 eV as the emission cross section of the dissociative ionization excitation process becomes more important relative to the dissociative excitation process. The FWHM of the N II (1085 A) line is 36+/-4 mA at 100 eV. For each multiplet the kinetic energy distribution function of each of the two fragment N atoms (ions) is much broader than thermal with a mean energy above 1.0 eV. The dissociation process with the largest cross section is predissociation and predominantly produces N atoms with kinetic energy distributions having mean energies above 0.5 eV. Dissociative processes can lead to a substantial escape flux of N I atoms from the satellites, Titan and Triton of the outer planets.

Ajello, Joseph M.↗

Technical Report Series on Global Modeling and Data Assimilation: Filtering Techniques on a Stretched Grid General Circulation Model - Volume 16

This report documents the techniques used to filter quantities on a stretched grid general circulation model. Standard high-latitude filtering techniques (e.g., using an FFT (Fast Fourier Transformations) to decompose and filter unstable harmonics at selected latitudes) applied on a stretched grid are shown to produce significant distortions of the prognostic state when used to control instabilities near the pole. A new filtering technique is developed which accurately accounts for the non-uniform grid by computing the eigenvectors and eigenfrequencies associated with the stretching. A filter function, constructed to selectively damp those modes whose associated eigenfrequencies exceed some critical value, is used to construct a set of grid-spaced weights which are shown to effectively filter without distortion. Both offline and GCM (General Circulation Model) experiments are shown using the new filtering technique. Finally, a brief examination is also made on the impact of applying the Shapiro filter on the stretched grid.

Takacs, Lawrence L.↗

Advanced Engine Health Management Applications of the SSME Real-Time Vibration Monitoring System

The Real Time Vibration Monitoring System (RTVMS) is a 32-channel high speed vibration data acquisition and processing system developed at Marshall Space Flight Center (MSFC). It Delivers sample rates as high as 51,200 samples/second per channel and performs Fast Fourier Transform (FFT) processing via on-board digital signal processing (DSP) chips in a real-time format. Advanced engine health assessment is achieved by utilizing the vibration spectra to provide accurate sensor validation and enhanced engine vibration redlines. Discrete spectral signatures (such as synchronous) that are indicators of imminent failure can be assessed and utilized to mitigate catastrophic engine failures- a first in rocket engine health assessment. This paper is presented in viewgraph form.

Fiorucci, Tony R.↗

Thermodynamic Behavior of Nano-sized Gold Clusters on the (001) Surface

We have studied thermal expansion of the surface layers of the hexagonally reconstructed Au (001) surface using a classical Molecular Dynamics (MD) simulation technique with an Embedded Atomic Method (EAM) type many-body potential. We find that the top-most hexagonal layer contracts as temperature increases, whereas the second layer expands or contracts depending on the system size. The magnitude of expansion coefficient of the top layer is much larger than that of the other layers. The calculated thermal expansion coefficients of the top-most layer are about -4.93 x 10(exp -5)Angstroms/Kelvin for the (262 x 227)Angstrom cluster and -3.05 x 10(exp -5)Angstroms/Kelvin for (101 x 87)Angstrom cluster. The Fast Fourier Transform (FFT) image of the atomic density shows that there exists a rotated domain of the top-most hexagonal cluster with rotation angle close to 1 degree at temperature T less than 1000Kelvin. As the temperature increases this domain undergoes a surface orientational phase transition. These predictions are in good agreement with previous phenomenological theories and experimental studies.

Paik, Sun M.↗

Applications Performance Under MPL and MPI on NAS IBM SP2

On July 5, 1994, an IBM Scalable POWER parallel System (IBM SP2) with 64 nodes, was installed at the Numerical Aerodynamic Simulation (NAS) Facility Each node of NAS IBM SP2 is a "wide node" consisting of a RISC 6000/590 workstation module with a clock of 66.5 MHz which can perform four floating point operations per clock with a peak performance of 266 Mflop/s. By the end of 1994, 64 nodes of IBM SP2 will be upgraded to 160 nodes with a peak performance of 42.5 Gflop/s. An overview of the IBM SP2 hardware is presented. The basic understanding of architectural details of RS 6000/590 will help application scientists the porting, optimizing, and tuning of codes from other machines such as the CRAY C90 and the Paragon to the NAS SP2. Optimization techniques such as quad-word loading, effective utilization of two floating point units, and data cache optimization of RS 6000/590 is illustrated, with examples giving performance gains at each optimization step. The conversion of codes using Intel's message passing library NX to codes using native Message Passing Library (MPL) and the Message Passing Interface (NMI) library available on the IBM SP2 is illustrated. In particular, we will present the performance of Fast Fourier Transform (FFT) kernel from NAS Parallel Benchmarks (NPB) under MPL and MPI. We have also optimized some of Fortran BLAS 2 and BLAS 3 routines, e.g., the optimized Fortran DAXPY runs at 175 Mflop/s and optimized Fortran DGEMM runs at 230 Mflop/s per node. The performance of the NPB (Class B) on the IBM SP2 is compared with the CRAY C90, Intel Paragon, TMC CM-5E, and the CRAY T3D.

Saini, Subhash↗

A FFT Method for the Quasiclassical Selection of Initial Ro-Vibrational States of Triatomic Molecules

This paper describes the use of an exact fast Fourier transform (FFT) method to prepare specified vibrational-rotational states of triatomic molecules. The method determines the Fourier coefficients needed to describe the coordinates and momenta of a vibrating-rotating triatomic molecule. Once the Fourier coefficients of a particular state are determined, it is possible to easily generate as many random sets of initial cartesian coordinates and momenta as desired. All the members of each set will correspond to the particular vibrational-rotational state selected. For example, in the case of the ground vibrational state of a non-rotating water molecule, the calculated actions of 100 sets of initial conditions produced actions within 0.001 h(bar) of the specified quantization values and energies within 5 cm(sup -1) of the semiclassical eigenvalue. The numerical procedure is straightforward for states in which all the fundamental frequencies are independent. However for states for which the fundamental frequencies become commensurate (resonance states), there are additional complications. In these cases it is necessary to determine a new set of "fundamental" frequencies and to modify the quantization conditions. Once these adjustments are made, good results are obtained for resonance states. The major problems are in labelling the large number of Fourier coefficients and the presence of regions of chaotic motion. Results are presented for the vibrational states of H2O and HCN and the ro-vibrational states of H2O.

Eaker, Charles W.↗

Non-Invasive Measurement of Intracranial Pressure Pulsation using Ultrasound

Exposure to microgravity causes a cephalad fluid shift which may elevate intracranial pressure (ICP). Elevation in ICP may affect cerebral hemodynamics in astronauts during space flight. ICP is, however, a difficult parameter to measure due to the invasiveness of currently available techniques. We already reported our development of a non-invasive ultrasound device for measurement of ICP. We recently modified the device so that we might reproducibly estimate ICP changes in association with cardiac cycles. In the first experiment, we measured changes in cranial distance with the ultrasound device in cadavera while changing ICP by infusing saline into the lateral ventricle. In the second experiment, we measured changes in cranial distance in five healthy volunteers while placing them in 60 deg, 30 deg head-up tilt, supine, and 10 deg head-down tilt position. In the cadaver study, fast Fourier transformation revealed that cranial pulsation is clearly associated with ICP pulsation. The ratio of cranial distance and ICP pulsation is 1.3microns/mmHg. In the tilting study, the magnitudes of cranial pulsation are linearly correlated to tilt angles (r=0.87). The ultrasound device has sufficient sensitivity to detect cranial pulsation in association with cardiac cycles. By analyzing the magnitude of cranial pulsation, estimates of ICP during space flight are possible.

Ueno, Toshiaki↗

Non-Invasive Measurement of Pulsatile Intracranial Pressures Using Ultrasound

Early detection of elevated intracranial pressure (ICP) will aid clinical decision-making for head trauma, brain tumor and other cerebrovascular diseases. Conventional methods, however, require surgical procedures which take time and are accompanied by increased risk of infection. Accordingly we have developed and refined a new ultrasound device to measure skull movements which are known to occur in conjunction with altered ICP. The principle of this device is based upon pulse phase locked loop (PPLL), which enables us to detect changes in distance on the order of microns between an ultrasound transducer on one side of the skull and the opposite inner surface of the cranium. The present study was designed to verify this measurement technique in cadavera. Transcranial distance was increased in steps of 10 mmHg from zero to 50 mmHg by saline infusion into the lateral ventricle of two cadavera. In separate experiments, pulsations of ICP with the amplitudes of zero to 2 mmHg were generated by rhythmic injections of saline using a syringe. When the ICP was stepwise increased from zero to 50 mmHg, transcranial distance increased in proportion with the ICP increase (y=12 x - 76, r=0.938), where y is changes in transcranial distance in microns and x is ICP in mmHg. In the data recorded while ICP pulsations were generated, fast Fourier transform analysis demonstrated that cranial pulsations were clearly associated with ICP pulsations. The results indicate that changes in transcranial distance is linearly correlated with those in ICP, and also that the PPLL device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. By analyzing the magnitude of cranial pulsations, we may be able to estimate the pressure-volume index in the cranium. As a result, estimates of intracranial compliance may be possible by using the PPLL device. Further studies are necessary in normal subjects and patients.

Ueno, Toshiaki↗

Communication Studies of DMP and SMP Machines

Understanding the interplay between machines and problems is key to obtaining high performance on parallel machines. This paper investigates the interplay between programming paradigms and communication capabilities of parallel machines. In particular, we explicate the communication capabilities of the IBM SP-2 distributed-memory multiprocessor and the SGI PowerCHALLENGEarray symmetric multiprocessor. Two benchmark problems of bitonic sorting and Fast Fourier Transform are selected for experiments. Communication-efficient algorithms are developed to exploit the overlapping capabilities of the machines. Programs are written in Message-Passing Interface for portability and identical codes are used for both machines. Various data sizes and message sizes are used to test the machines' communication capabilities. Experimental results indicate that the communication performance of the multiprocessors are consistent with the size of messages. The SP-2 is sensitive to message size but yields a much higher communication overlapping because of the communication co-processor. The PowerCHALLENGEarray is not highly sensitive to message size and yields a low communication overlapping. Bitonic sorting yields lower performance compared to FFT due to a smaller computation-to-communication ratio.

Sohn, Andrew↗

Frequency Analyzed Laser Light Scattering (Falls)

A simple and robust light scattering technique for spray diagnostics was developed. The technique provides a spray's intact length and breakup frequency. Scattered light is collected from a laser sheet that illuminates a portion of the spray. The scattered light is imaged on a fast photodiode whose output is sampled at 20 kHz. Fast Fourier transform (FFT) analysis is performed on the sampled signal. The shape of the FFT produced can be correlated to one of three distinct spray regimes: intact sheet, ligaments, or droplets. Strobe and laser illuminated photographs are also shown for reference.

Rhys, Noah O.↗

An Investigation into the Potential Application of Wavelets to Modal Testing and Analysis

The analysis of transient data of the type found in vibrating mechanical systems has been greatly improved through the use of modern techniques such as Fourier analysis. This is especially true when considered in conjunction with the development of the so-called Fast Fourier Transform algorithm by Cooley and the tremendous strides in computational power of the last several decades. The usefulness of the discrete Fourier Transform is its ability to transform sampled data from the "time-domain" to the "frequency domain," thereby allowing the analyst to decompose a signal into its frequency content. More recent developments have led to the wavelet transform. The strength of wavelet analysis is its ability to maintain both time and frequency information, thus making it an attractive candidate for the analysis of non-stationary signals. This report is an overview of wavelet theory and the potential use of the wavelet transform as an alternative to Fourier analysis in modal identification.

A. Fort Gwinn, Jr.↗

Ultrasonic Resonance Spectroscopy of Composite Rims for Flywheel Rotors

Flywheel energy storage devices comprising multilayered composite rotor systems are being studied extensively for utilization in the International Space Station. These composite material systems were investigated with a recently developed ultrasonic resonance spectroscopy technique. The ultrasonic system employs a continuous swept-sine waveform and performs a fast Fourier transform (FFT) on the frequency response spectrum. In addition, the system is capable of equalizing the amount of energy at each frequency. Equalization of the frequency spectrum, along with interpretation of the second FFT, aids in the evaluation of the fundamental frequency. The frequency responses from multilayered material samples, with and without known defects, were analyzed to assess the capabilities and limitations of this nondestructive evaluation technique for material characterization and defect detection. Amplitude and frequency changes were studied from ultrasonic responses of thick composite rings and a multiring composite rim. A composite ring varying in thickness was evaluated to investigate the full thickness resonance. The frequency response characteristics from naturally occurring voids in a composite ring were investigated. Ultrasonic responses were compared from regions with and without machined voids in a composite ring and a multiring composite rim. Finally, ultrasonic responses from the multiring composite rim were compared before and after proof spin testing to 63,000 rpm.

Harmon, Laura M.↗