Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fermilab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Superconducting radiofrequency linac development at Fermilab

As the Fermilab Tevatron Collider program draws to a close, a strategy has emerged of an experimental program built around the high intensity frontier. The centerpiece of this program is a superconducting H- linac that will support world leading programs in long baseline neutrino experimentation and the study of rare processes. Based on technology shared with the International Linear Collider, Project X will provide multi-MW beams at 60-120 GeV from the Main Injector, simultaneous with very high intensity beams at lower energies. Project X also supports development of a Muon Collider as a future facility at the energy frontier.

43 PARTICLE ACCELERATORS↗

Project X: A Multi-MW Proton Source at Fermilab

As the Fermilab Tevatron Collider program draws to a close a strategy has emerged of an experimental program built around the high intensity frontier. The centerpiece of this program is a superconducting H- linac that will support world leading programs in long baseline neutrino experimentation and he study of rare processes. Based on technology shared with the International Linear Collider (ILC), Project X will provide multi-MW beams at 60-120 GeV from the Main Injector, simultaneous with very high intensity beams at lower energies. Project X will also support development of a Muon Collider as a uture facility at the energy frontier.

43 PARTICLE ACCELERATORS↗

Material Activation Benchmark Experiments at the NuMI Hadron Absorber Hall in Fermilab

In our previous study, double and mirror symmetric activation peaks found for Al and Au arranged spatially on the back of the Hadron absorber of the NuMI beamline in Fermilab were considerably higher than those expected purely from muon-induced reactions. From material activation bench-mark experiments, we conclude that this activation is due to hadrons with energy greater than 3 GeV that had passed downstream through small gaps in the hadron absorber.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The fast non-ferric kicker system for the Muon g–2 Experiment at Fermilab

Here we describe the installation, commissioning, and characterization of the new injection kicker system in the Muon g – 2 Experiment (E989) at Fermilab, which makes a precision measurement of the muon magnetic anomaly. Three Blumlein pulsers drive each of the 1.27-m-long non-ferric kicker magnets, which reside in a storage ring vacuum (SRV) that is subjected to a 1.45 T magnetic field. The new system has been redesigned relative to Muon g – 2 ’s predecessor experiment, and we present those details in this manuscript.

43 PARTICLE ACCELERATORS↗

Qualifying LaBr3:Ce+Sr detector performance for the Mu2e experiment at Fermilab Using the ELBE Accelerator

A LaBr3:Ce+Sr detector will be used to measure the stopped muon captures at the Mu2e experiment at Fermilab. It has been benchmarked in a test beam experiment performed at the ELBE electron accelerator located at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. ELBE’s pulsed bremsstrahlung beam line was set to deliver an average γ -ray energy of between 4–5 MeV. The detector response was mapped to match Mu2e beam conditions, including rates up to 1 Mcps, energy flux, and time structure. A radioactive calibration source was used to mimic the characteristic 1808.7 keV γ -ray, emitted during the atomic muon nuclear capture in the Mu2e aluminum stopping target. The detector energy resolution was measured as a function of the average energy flux: up to 1 TeV/s for 0.34 s, the steady-operation beam-on time and up to 4 TeV/s for 5 ms to get a conservative estimate of the effect of high intensity Mu2e beam fluctuations. The PMT gain variation as a function of the beam spill length and average intensity has been parametrized and corrected for. When a PMT gain correction corresponding to the average beam-spill intensity is applied, the residual effect of beam intensity fluctuations around the average degrades the energy resolution, σ E γ /E γ , at 1808.7 keV from 0.66% to 0.83%.

Huang, Shihua [Purdue U., West Lafayette]↗

The Fermilab Neutrino Beam Program

This talk presents an overview of the Fermilab Neutrino Beam Program. Results from completed experiments as well as the status and outlook for current experiments is given. Emphasis is given to current activities towards planning for a future program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CRYOGENIC INFRASTRUCTURE FOR FERMILAB'S ILC VERTICAL CAVITY TEST FACILITY

Fermilab is building a Vertical Cavity Test Facility (VCTF) to provide for R and D and pre-production testing of bare 9-cell, 1.3-GHz superconducting RF (SRF) cavities for the International Linear Collider (ILC) program. This facility is located in the existing Industrial Building 1 (IB1) where the Magnet Test Facility (MTF) also resides. Helium and nitrogen cryogenics are shared between the VCTF and MTF including the existing 1500-W at 4.5-K helium refrigerator with vacuum pumping for super-fluid operation (125-W capacity at 2-K). The VCTF is being constructed in multiple phases. The first phase is scheduled for completion in mid 2007, and includes modifications to the IB1 cryogenic infrastructure to allow helium cooling to be directed to either the VCTF or MTF as scheduling demands require. At this stage, the VCTF consists of one Vertical Test Stand (VTS) cryostat for the testing of one cavity in a 2-K helium bath. Planning is underway to provide a total of three Vertical Test Stands at VCTF, each capable of accommodating two cavities. Cryogenic infrastructure improvements necessary to support these additional VCTF test stands include a dedicated ambient temperature vacuum pump, a new helium purification skid, and the addition of helium gas storage. This paper describes the system design and initial cryogenic operation results for the first VCTF phase, and outlines future cryogenic infrastructure upgrade plans for expanding to three Vertical Test Stands.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CRYOGENIC CONTROLS FOR FERMILAB'S SRF CAVITIES AND TEST FACILITY

A new superconducting radio frequency (SRF) cavities test facility is now operational at Fermilab's Meson Detector Building (MDB). The Cryogenic Test Facility (CTF), located in a separate building 500 m away, supplies the facility with cryogens. The design incorporates ambient temperature pumping for superfluid helium production, as well as three 0.6 kW at 4.5 K refrigerators, five screw compressors, a helium purifier, helium and nitrogen inventory, cryogenic distribution system, and a variety of test cryostats.To control and monitor the vastly distributed cryogenic system, a flexible scheme has been developed. Both commercial and experimental physics tools are used. APACS+, a process automation control system from Siemens-Moore, is at the heart of the design. APACS+ allows engineers to configure an ever evolving test facility while maintaining control over the plant and distribution system. APACS+ nodes at CTF and MDB are coupled by a fiber optic network. DirectLogic205 PLCs by KOYO are used as the field level interface to most I/O.The top layer of this system uses EPICS (Experimental Physics and Industrial Control System) as a SCADA/HMI. Utilities for graphical display, control loop setting, real time/historical plotting and alarming have been implemented by using the world-wide library of applications for EPICS.OPC client/server technology is used to bridge across each different platform.This paper presents this design and its successful implementation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polarization Study Of {lambda}{sub c} Baryon Using Data From The Fermilab E831 Experiment

Using the data obtained by the Fermilab E831 photoproduction Experiment, a spin polarization study of {lambda}{sub c} baryon is presented for two of its decay modes: {lambda}{sub 0}{pi} and K{sub s}p. Preliminary polarization results for {lambda}{sub 0}{pi} and values of the product {alpha}{sub {lambda}{sub c}}P for K{sub s}p are obtained. We show that, for {lambda}{sub 0}{pi}, {lambda}{sub c} is produced with a small polarization that due to the low statistics is consistent with zero within 2{sigma}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The PEANUT experiment in the NuMI beam at Fermilab

The PEANUT experiment was designed to study neutrino interactions in the few GeV range using the NuMI beam at Fermilab. The detector uses a hybrid technique, being made of nuclear emulsions and scintillator trackers. Emulsion films act as a tracking device and they are interleaved with lead plates used as neutrino targets. The detector is designed to reconstruct the topology of neutrino interactions at the single particle level. We present here the full reconstruction and analysis of a sample of 147 neutrino interactions that occurred in the PEANUT detector and the measurement of the quasielastic, resonance and deep-inelastic contributions to the total charged-current cross section. This technique could be applied for the beam monitoring at future neutrino facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton Beam Formation at Fermilab for mu2e (and for NF/MC)

Proton bunch formation from the Fermilab proton sources for the mu2e experiment is discussed. In the initial scenario a single intense h = 1 bunch is formed in the Accumulator/Debuncher, with slow extraction providing the required spill. However, the mu2e experiment could use h = 4 bunching in the Accumulator rather than h = 1, with the 4 bunches fed one at a time into the more isochronous Debuncher for slow extraction. The h = 4 variant has several advantages and a few disadvantages, and can reduce peak beam intensities, and therefore improve space charge limits. The method can be extended to project X to enable high duty cycle extraction within space charge limits. A further extension should make possible an accumulator/buncher scenario that can provide 8 GeV short bunches for a neutrino factory and/or muon collider scenario.

43 PARTICLE ACCELERATORS↗

Project X and a Muon Facility at Fermilab

An integrated program is described, starting with muon experiments in the Booster era, continuing with a 2 MW target station, a 4 GeV Neutrino Factory and a 3 TeV Muon Collider, all driven by Project X. This idea provides an integrated approach to the Intensity and Energy Frontiers at Fermilab.

43 PARTICLE ACCELERATORS↗

Main Injector Particle Production Experiment (MIPP) at Fermilab

The Main Injector Particle Production Experiment at Fermilab uses particle beams of charged pions, kaons, proton and anti-proton with beam momenta of 5 to 90 GeV/c and thin targets spanning the periodic table from (liquid) hydrogen to uranium to measure particle production cross sections in a full acceptance spectrometer with charged particle identification for particles from 0.1 to 120 GeV/c using Time Projection Chamber, Time of Flight, multicell Cherenkov, and Ring Imaging Cherenkov detectors and Calorimeter for neutrons. Particle production using 120 GeV/c protons from Main Injector on the MINOS target was also measured. We describe the physics motivation to perform such cross section measurements and highlight the impact of hadronic interaction data on neutrino physics. Recent results on forward neutron cross sections and analysis of MINOS target data are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermilab E906/SeaQuest Drell-Yan Experiment

The E906/SeaQuest experiment will use the 120 GeV proton beam extracted from the Fermilab Main Injector to measure the Drell-Yan cross section in p-p, p-d, and p-A scattering. Data from liquid hydrogen and deuterium targets will be sensitive to the light anti-quark asymmetry, d-bar/u-bar, over a range of parton momentum fraction 0.04<x<0.45. Previous measurements from the E866/NuSea experiment have shown that while there were clear signs of flavor asymmetry at moderate x, the quark sea became flavor symmetric at higher x, suggesting a possible shift in the underlying mechanism generating the sea. Measurements from solid nuclear targets (carbon, calcium, and tungsten) will determine the modification of antiquark distributions in the nucleus. The results, in addition to being complementary to similar measurements performed through deep inelastic scattering, will also be valuable in providing the nuclear corrections necessary to extract nucleon parton distribution functions from neutrino data. The experiment will start in 2011, and will run for two years.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mu2e, a coherent μ → e conversion experiment at Fermilab

We describe a proposed experiment to search for Charged Lepton Flavor Violation (CLFV) using stopped muons at Fermilab. A primary Proton beam will strike a gold target, producing pions which decay to muons. Low-momentum negative muons will be collected, selected, and transported by a custom arrangement of solenoidal magnets and collimators. Muons will stop in thin foil targets, creating muonic atoms with significant nuclear overlap. Mu2e will search for the coherent conversion of nuclear bound muons to electrons, with an experimental signature of a single mono-energetic electron. Conversion electrons will be detected and measured in a low-mass straw tracker and a crystal calorimeter. Mu2e will have a sensitivity four orders of magnitude better than the most sensitive published result for μ → e conversion, and will have complementary physics reach to LHC experiments and μ → eγ decay experiments such as MEG.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Fermilab short-baseline neutrino program

The Fermilab short-baseline program is a multi-facetted one. Primarily it searches for evidence of sterile neutrinos as hinted at by the MiniBooNE and LSND results. It will also measure a whole suite of ν-Argon cross sections which will be very useful in future liquid argon long-baseline projects. The program is based on MicroBooNE, already installed in the beam line, the recently approved LAr1-ND and the future addition of the refurbished ICARUS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Future possibilities with Fermilab neutrino beams

We will start with a brief overview of neutrino oscillation physics with emphasis on the remaining unanswered questions. Next, after mentioning near future reactor and accelerator experiments searching for a non zero {theta}{sub 13}, we will introduce the plans for the next generation of long-baseline accelerator neutrino oscillation experiments. We will focus on experiments utilizing powerful (0.7-2.1 MW) Fermilab neutrino beams, either existing or in the design phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synchrotron radiation based beam diagnostics at the Fermilab Tevatron

Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. Therefore, if one utilizes the radiation originating near the edge of a bending magnet, or from a short magnet, the rapidly changing magnetic field serves to enhance the wavelengths shorter than the cutoff wavelength, which for more recent high energy proton accelerators such as Fermilab's Tevatron, tends to be visible light. This paper discusses the implementation at the Tevatron of two devices. A transverse beam profile monitor images the synchrotron radiation coming from the proton and antiproton beams separately and provides profile data for each bunch. A second monitor measures the low-level intensity of beam in the abort gaps which poses a danger to both the accelerator's superconducting magnets and the silicon detectors of the high energy physics experiments. Comparisons of measurements from the profile monitor to measurements from the flying wire profile systems are presented as are a number of examples of the application of the profile and abort gap intensity measurements to the modelling of Tevatron beam dynamics.

43 PARTICLE ACCELERATORS↗