Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A Novel Technique Using a Protection Filter During Fibrin Sheath Removal for Implanted Venous Access Device Dysfunction

With the increased use of implanted venous access devices (IVADs) for continuous long-term venous access, several techniques such as percutaneous endovascular fibrin sheath removal, have been described, to maintain catheter function. Most standard techniques do not capture the stripped fibrin sheath, which is subsequently released in the pulmonary circulation and may lead to symptomatic pulmonary embolism. The presented case describes an endovascular technique which includes stripping, capture, and removal of fibrin sheath using a novel filter device. A 64-year-old woman presented with IVAD dysfunction. Stripping was performed using a co-axial snare to the filter to capture the fibrin sheath. The captured fragment was subsequently removed for visual and pathological verification. No immediate complication was observed and the patient was discharged the day of the procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LANDSAT-4 and LANDSAT-5 Multispectral Scanner Coherent Noise Characterization and Removal

A technique is described for characterizing the coherent noise found in LANDSAT-4 and LANDSAT-5 MSS data and a companion technique for filtering out the coherent noise. The techniques are demonstrated on LANDSAT-4 and LANDSAT-5 MSS data sets, and explanations of the noise pattern are suggested in Appendix C. A cookbook procedure for characterizing and filtering the coherent noise using special NASA/Goddard IDIMS functions is included. Also presented are analysis results from the retrofitted LANDSAT-5 MSS sensor, which shows that the coherent noise has been substantially reduced.

Tilton, James C.↗

A Novel Technique for Inferior Vena Cava Filter Extraction

Inferior vena cava (IVC) filters are used to protect against pulmonary embolism in high-risk patients. Whilst the insertion of retrievable IVC filters is gaining popularity, a proportion of such devices cannot be removed using standard techniques. We describe a novel approach for IVC filter removal that involves snaring the filter superiorly along with the use of flexible forceps or laser devices to dissect the filter struts from the caval wall. This technique has used to successfully treat three patients without complications in whom standard techniques failed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray Emission from Electron Betatron Motion in a Laser-Plasma Accelerator

Single-shot x-ray spectra from electron bunches produced by a laser-plasma wakefield accelerator (LPA) were measured using a photon-counting single-shot pixelated Silicon-based detector [3], providing for the first time direct spectra without assumptions required by filter based techniques. In addition, the electron bunch source size was measured by imaging a wire target, demonstrating few micron source size and stability. X-rays are generated when trapped electrons oscillate in the focusing field of the wake trailing the driver laser pulse. In addition to improving understanding of bunch emittance and wake structure, this provides a broadband, synchronized femtosecond source of keV x-rays. Electron bunch spectra and divergence were measured simultaneously and preliminary analysis shows correlation between x-ray andelectron spectra. Bremsstrahlung background was managed using shielding and magnetic diversion.

43 PARTICLE ACCELERATORS↗

Two techniques enable sampling of filtered and unfiltered molten metals

Filtered samples of molten metals are obtained by filtering through a plug of porous material fitted in the end of a sample tube, and unfiltered samples are obtained by using a capillary-tube extension rod with a perforated bucket. With these methods there are no sampling errors or loss of liquid.

Burris, L., Jr.↗

A directional filter diplexer using optical techniques for millimeter to submillimeter wavelengths

An optical diplexer for injection of a local oscillator into a mixer, useful in the submillimeter and short millimeter range, is described. It has very low insertion loss for both the signal and local oscillator (LO) and high rejection of LO noise. The measured performance of a unit tested at 337 GHz indicates a loss of about 0.2 dB for both inputs and 20-dB noise rejection.

Erickson, N. R.↗

Accuracy and resolution of Earth Radiation Budget Estimates

A numerical filter inversion technique that reduces wide-angle satellite measurements to top-of-the-atmosphere radiant exitances has been proposed for the Earth Radiation Budget Experiment (ERBE). The matrix formulation of this technique is presented, and the design of the numerical filter is discussed. The filter is smoothed with a singular value decomposition. The inversion process is simulated by generating synthetic measurements from a 24 degree spherical harmonic radiation field derived from Nimbus 6 ERB data. The numerical filter is applied to these measurements after they are corrupted with instrument error. The results are curves of expected error versus resolution area.

Green, R. N.↗

Axial and transverse characterizations of ceramic candle filters

Ceramic candle filters are stiff composite tubes used in particle-removal during hot-gas filtration in coal energy generation. These filters are designed to withstand high temperature and pressure gradients. To determine the consistency in manufactured qualities of these filters, dynamic characterization method is recommended as a nondestructive evaluation technique. Six filters of the same manufactured batch were tested dynamically to establish the baseline properties of these filters. The test results are compared to theoretical values and are used to identify the variation in the manufactured products. This paper reports the frequencies in both transverse and axial directions indicating acceptable variations between all filters that are compatible to variations in measured physical parameters including density, stiffness and elastic modulus.

01 COAL, LIGNITE, AND PEAT↗

Probing two-path electron quantum interference in strong-field ionization with time-correlation filtering

We report attosecond dynamics in strong-field tunnel ionization are encoded in intricate holographic patterns in the photoelectron momentum distributions. These patterns show the interference between two or more superposed quantum electron trajectories, which are defined by their ionization times and subsequent evolution in the laser field. We determine the ionization time separation between interfering pairs of electron orbits by performing a differential Fourier analysis on the measured momentum spectrum. We identify electron holograms formed by trajectory pairs whose ionization times are separated by less than a single quarter cycle, between a quarter cycle and half cycle, between a half cycle and three fourths of a cycle, and a full cycle apart. We compare our experimental results to the predictions of the Coulomb quantum orbit strong-field approximation (CQSFA) with significant success. We also time-filter the CQSFA trajectory calculations to demonstrate the validity of the technique on spectra with known time correlations. As a general analysis technique, the filter can be applied to all energy- and angularly resolved data sets to recover time correlations between interfering electron pathways, providing an important tool to analyze any strong-field ionization spectra. Moreover, it is independent of theory and can be applied directly to experiments, without the need of a direct comparison with orbit-based theoretical methods.

74 ATOMIC AND MOLECULAR PHYSICS↗

Statistical Error Analysis on White-Light Filter Ratio Experiments to Measure Electron Parameters

The Filter ratio technique to remotely measure electron temperature and speed using four color filters in visible light and a polarization camera was described in detail in four articles by Reginald et al., Solar physics, (2018, 2019a, 2019b, 2020). In these four articles we quantified the systematic error associated with using models of symmetric corona to interpret results from asymmetric corona. We also showed the criteria applied to select the bandwidths of filters, and the pros and cons of replacing the traditional linear polarizer with a polarization camera to measure pB. What started in 1990s as ground experiments conducted during total solar eclipses that lasted for a few minutes lead to a balloon borne experiment lasting eight hours in 2019 and will blossom into a space experiment on the International Space Station in 2023. Due to constraints on the bandwidths of the four filters, a successful mission requires quantification of the statistical error using Monte Carlo simulation to generate two feasibility profiles, which are unique to the design parameters of the coronagraph, to comprehend the feasibility to measure temperature and speed within the desired temporal and spatial resolutions. For the statistical error analysis, we use modeled K and F corona profiles, representative theoretical diffraction, scattering, and vignetting profiles, assumed efficiencies for lenses, mirrors, and polarizers, assumed detector properties on quantum efficiency, full well depth, dark noise, and read noise, and assumed instrument properties on aperture diameter, solid angle, and pixel resolution. We hope future white-light coronagraphs will exhibit capabilities to measure electron density, temperature, and speed.

Nelson Reginald↗

Lunar surface chemistry - A new imaging technique

Detailed chemical maps of the lunar surface have been constructed by applying a new weighted-filter imaging technique to Apollo 15 and Apollo 16 X-ray fluorescence data. The data quality improvement is amply demonstrated by (1) modes in the frequency distribution, representing highland and mare soil suites, which are not evident before data filtering, and (2) numerous examples of chemical variations which are correlated with small-scale (about 15 kilometer) lunar topographic features.

Andre, C. G.↗

Shortwave wide-field-of-view results from the Earth Radiation Budget Experiment

The deconvolution (DCN) and numerical filter (NF) techniques of analyzing nonscanning radiometer measurements are evaluated by comparison with scanning radiometer results for monthly mean maps of albedo and absorbed solar radiation. Both techniques successfully enhance the resolution of the monthly mean product. The numerical filter albedo adheres closer to the scanning radiometer in the zonal average than does the DCN albedo. Zonal rms's, however, show that the DCN albedo is about 1 percent better than the NF in the Southern Hemisphere, but in the Northern Hemisphere the NF is better by up to 2 percent.

Rutan, David↗

The Aeolus-Earth DWTS Heliophysics Mission

The Aeolus-Earth Mission (DWTS-Helio) is a recently selected NASA Heliophysics investigation that will apply the innovative Doppler Wind Temperature Sounder (DWTS) technique to the Space Atmosphere Interaction Region (SAIR) at ~105-180 km. The technique, invented by Gordley & Marshall (2011), applies the Doppler Scanning with Gas Filter (DSGF) technique using a cryo-cooled MWIR radiometer to view the limb of the atmosphere from LEO (orbital velocity creates the Doppler shifts required by the technique). For this implementation of DWTS, a Nitric Oxide (NO) low pressure gas cell is used. The limb of the atmosphere is observed from a spacecraft at orbital velocity, and as an observed air volume passes through the field of view, this velocity creates a set of Doppler-shifted images. These images are used to create Doppler Integrated Pass (DIP) signals, from which atmospheric temperature and wind profiles are extracted (it may be considered a converse of the successful in-flight calibration of gas cells used for the HALOE instrument). The technique is relative, removing the need for absolute radiances, and the signal-to-noise ratio for this technique is high, resulting in good measurement precision. Different gas cells can be used to create different altitude coverage and may be combined to measure a more continuous altitude range. For example, using a NO cell captures the lower atmosphere from 30-50km as well as the SAIR, while using the 13 isotopologue of CO2 would capture 50-120km. Due to the desired data volume as well as power and thermal considerations, this initial Aeolus-Earth flight will be more suited for a ‘hosted’ payload on an Orbital Maneuvering Vehicle platform instead of the ‘free-flyer’ option originally investigated. Lastly, the technique is sufficiently powerful that a two-channel system could produce full Mars atmosphere data not currently possible.

DWTS↗

Characterization of Mid-Infrared Single Mode Fibers as Modal Filters

We present a technique for measuring the modal filtering ability of single mode fibers. The ideal modal filter rejects all input field components that have no overlap with the fundamental mode of the filter and does not attenuate the fundamental mode. We define the quality of a nonideal modal filter Q(sub f) as the ratio of transmittance for the fundamental mode to the transmittance for an input field that has no overlap with the fundamental mode. We demonstrate the technique on a 20 cm long mid-infrared fiber that was produced by the U.S. Naval Research Laboratory. The filter quality Q(sub f) for this fiber at 10.5 micron wavelength is 1000 +/- 300. The absorption and scattering losses in the fundamental mode are approximately 8 dB/m. The total transmittance for the fundamental mode, including Fresnel reflections, is 0.428 +/- 0.002. The application of interest is the search for extrasolar Earthlike planets using nulling interferometry. It requires high rejection ratios to suppress the light of a bright star, so that the faint planet becomes visible. The use of modal filters increases the rejection ratio (or, equivalently, relaxes requirements on the wavefront quality) by reducing the sensitivity to small wavefront errors. We show theoretically that, exclusive of coupling losses, the use of a modal filter leads to the improvement of the rejection ratio in a two-beam interferometer by a factor of Q(sub f).

single mode fibers↗

Input filter compensation for switching regulators

Problems caused by input filter interaction and conventional input filter design techniques are discussed. The concept of feedforward control is modeled with an input filter and a buck regulator. Experimental measurement and comparison to the analytical predictions is carried out. Transient response and the use of a feedforward loop to stabilize the regulator system is described. Other possible applications for feedforward control are included.

Lee, F. C.↗