Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fuel efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Potential Economic Values of Low-Vapor-Pressure Gasoline-Range Bio-Blendstocks: Property Estimation, and Blending Optimization

Adding non-traditional blendstocks derived from biomass into gasoline has gained renewed interest since it will reduce greenhouse gas emissions and potentially enhance fuel properties and boost engine efficiencies. A competitive bio-blendstock candidate should have either lower prices or superior properties or both relative to conventional gasoline blending components. Gasoline is a mixture of hundreds compounds specified by properties rather than compositions. The addition of bio-blendstocks, most likely oxygenates, will modify the property mixing rules due to the non-ideal interactions between polar and nonpolar components. This paper presents an equation-of-state-based model for predicting Reid vapor pressure, reduced order non-linear property blending models for computing key properties of final gasoline products, and a blending optimization approach to identify key economic drivers. This paper also evaluates the economic values of bio-blendstocks to petroleum refiners using those models. In additional to ethanol, six low-vapor-pressure bio-blendstock candidates were evaluated: i-propanol, n-propanol, i-butanol, diisobutylene, cyclopentanone, and a mixture of furans. Reid vapor pressure, distillation temperatures, and octane numbers were identified as the key economic drivers of adding bio-blendstock. The economic values of those bio-blendstocks range from 2.22 to 4.00 US dollar per gasoline gallon equivalent in 2013 to 2017 5-year averaged price basis. The bio-blendstocks with higher octane numbers may have higher economic values. The uncertainties in property predictions may lead to roughly 15% deviation in the economic value evaluation.

Jiang, Yuan↗

Red-Light-Driven Biophotochemical Diode Based on a Microorganism–Silicon Nanowire Interface for Stable and Efficient Bias-Free CO 2 Reduction

Artificial photosynthesis offers a promising route for sustainable liquid fuel and feedstock production, yet integrating efficient CO 2 reduction catalysts with light-harvesting systems remains challenging. Here, in this study, we present a biophotochemical diode that couples microorganism-driven CO 2 reduction with glycerol oxidation, enabled by silicon nanowire photoelectrodes under varying red-light intensities. Tuning the biotic-abiotic interface─by increasing biocatalyst loading and adjusting the catholyte pH to mitigate local alkalization─significantly improves performance and stability. The enhanced-loading biocathode maintains a high faradaic efficiency across a wide potential range, even under elevated light intensities. At 60 mW/cm 2 , the system achieves a bias-free current density of 3.5 mA/cm 2 . Long-term stability testing at 40 mW/cm 2 demonstrates stable operation for over 100 h. The photoanode generates valuable C 3 products, primarily glycerate and lactate, enhancing the economic viability. This work showcases the importance of microenvironmental control at the biotic-abiotic interface and establishes a scalable platform for light-driven CO 2 reduction using earth-abundant silicon.

Artificial Photosynthesis↗

Enhanced energy conversion efficiency promoted by cavitation in gasoline direct injection

High-pressure direct fuel injection plays the most crucial role in energy conversion and improving engine combustion efficiency and emission. The optimization of turbulent and multiphase fuel injection has focused on controlling hydrodynamic parameters such as injection pressure. While the thermodynamic influence is often considered in the flash boiling situation, we inquire into how gasoline-type fuel’s hydro- and thermodynamic properties impact the injection dynamics by fuel-temperature induced cavitation. The turbulent and cavitating flows emanating from the direct-injection nozzle is visualized by ultrafast x-ray imaging with an unprecedented spatiotemporal resolution. The ultrafast liquid-fuel dynamics are dominated by injection pressure as well as fuel temperature through cavitation, an important thermodynamic parameter but often difficult to control in engine combustion. With the most direct and quantitative measurement, we discovered that the near-nozzle fuel-jet dynamics can be perfectly scaled by a single dimensionless parameter, cavitation number, particularly sensitive to the fuel temperature, in a wide operation range. This universal scaling shows that cavitation can be harnessed to elevate the pneumatic-hydraulic to kinetic energy conversion efficiency, critical for promoting fuel atomization and engine combustion performance. This enhancement effect will have even more impact on engine combustion using alternative low-emission fuels with higher saturated vapor pressure.

30 DIRECT ENERGY CONVERSION↗

System efficiency and power assessment of the all-aqueous copper thermally regenerative ammonia battery

Thermally regenerative ammonia batteries (TRABs) use low-temperature (T < 100 °C) heat to provide stationary energy and power with higher power densities and efficiency relative to other waste heat devices. TRABs are an active area of research in waste heat devices, but currently there is little consensus on what aspect of the system is limiting TRAB performance and what maximum efficiencies are possible. Experiments and numerical models were used here to examine the sensitivity of the battery and distillation column in a TRAB system to key operating variables, thereby establishing practical limits and identifying focus areas for improving performance. Battery power was eight times more sensitive to ohmic losses than kinetic and mass transfer losses, regardless of the operating temperature, and the peak power density was simulated to be 18.8 mW cm –2 at 75 °C. Theoretical energy efficiency limits were defined for a series of ammonia concentrations and operating pressures, ranging from 5 – 12%, which is 2–3 times higher than previous experimental estimations. Atmospheric pressure column operation used a larger amount of waste heat compared to sub-atmospheric pressure. It is estimated that the volume of the battery would take up 9.2m 3 for every 1% of the power output of a natural gas turbine, but with realistic improvements to cell conductivity, the size would reduce to 2.5 m 3 . Finally, the results presented in this work will help streamline future development by focusing on minimizing ohmic losses and provide specific data for full system evaluation of future TRABs.

25 ENERGY STORAGE↗

Energy Savings Results from Small Commercial Building Retrofits in the US

Small commercial buildings, or those comprising less than 50,000 square feet of floor area, represent 94% of U.S commercial buildings by count and consume approximately 8% of the nation’s primary energy; as such, they represent a largely unexploited opportunity for energy savings. Small commercial buildings also represent a large economic market—the National Institute of Building Sciences (NIBS) estimated the small commercial retrofit market at USD 35.6 billion. Despite the prominence of small commercial buildings and the economic opportunity for energy retrofits, many energy efficiency programs focus on large commercial buildings, and create efficiency solutions that do not meet the needs of the small commercial market. This paper presents an analysis of 34 small commercial case study projects that implemented energy efficiency retrofits. This paper contributes to the existing building retrofit body of knowledge in the following ways: (1) it identifies the decision criteria used by small commercial building stakeholders that decided to complete an energy retrofit; (2) it identifies the most commonly implemented efficiency measures in small commercial buildings, and discusses why this is the case; and (3) it provides empirical evidence about the efficacy of installing single energy efficiency measures (EEMs) compared to packages of EEMs in small commercial buildings by reporting verified energy savings. To the authors’ knowledge, this paper is the first to catalog decision criteria and energy savings for the existing small commercial buildings market, and this research illustrates that small commercial building decision-makers seem most motivated to retrofit their spaces by energy cost savings and operational concerns. Furthermore, small commercial building decision-makers opted to implement single-system retrofits in fifteen (15) of the thirty-four cases studied. Finally, this research documents the improved savings, in the small commercial buildings market, associated with a more integrated package of EEMs compared to a single-system approach, achieving approximately 10% energy savings for a single-system approach and more than 20% energy savings for integrated approaches. These savings translate to CO2 savings of 1,324,000 kgCO2/year to 2,647,000 kgCO2/year, respectively, assuming small commercial buildings are retrofit at a rate of 0.95% of the stock annually.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Powertrain Performance and Total Cost of Ownership Analysis for Class 8 Yard Tractors and Refuse Trucks

Advanced powertrain technologies, specifically fuel cell electric powertrains, have gained attention as viable alternatives for medium- and heavy-duty (M/HD) vehicles. However, it is unclear how these alternative powertrain vehicles stack up against their diesel counterparts in terms of performance and total cost of ownership (TCO). Furthermore, there are vehicle segments within the M/HD sector that have remained unstudied for fuel cell electric applications. This analysis aims to provide a comparative scoping-level TCO and performance analysis for two heavy-duty vocation vehicles (Class 8 U.S. port-side yard tractor and Class 8 U.S.-based refuse truck) for both conventional diesel and heavy-duty fuel cell electric (HDFC) powertrains. The refuse truck analysis also considered compressed natural gas powertrains (CNG) for comparison. The analysis includes seven timeframes (2020, 2025, 2030, 2035, 2040, 2045, and 2050) for comparison. This simplified TCO analysis includes only direct costs (fuel price, glider purchase price, and operating & maintenance costs) and excludes any associated indirect cost (e.g., dwell time costs and other opportunity based costs). Representative drive cycles for each vehicle were based on on-board GPS logged data and chosen by the analysis team to represent average, non-extreme driving conditions. At the time the analysis was performed, the Inflation Reduction Act was not in effect and therefore any potential subsidies and future cost reductions enacted under the Inflation Reduction Act were not included. Based on the operational setpoints used in this analysis, HDFC powertrains for both yard tractors and refuse trucks have the potential to achieve TCO advantages over conventional diesel powertrains (and CNG for refuse truck applications) in the near- to mid-term future while meeting the necessary duty cycle performance requirements. Yard tractors and refuse trucks spend a significant amount of time operating at low speeds, with long durations of idling, and experience numerous start/stop occurrences. These operational characteristics favor fuel cell performance as fuel cells operate with higher efficiencies at lower percentages of total power output. Conversely, conventional diesel and CNG engines are most efficient at higher percentages of total power output. This helps HDFC powered yard tractors and refuse trucks realize improved fuel economy when compared to their diesel counterparts, which helps reduce total fuel costs and therefore, total TCO. The analysis demonstrates that fuel prices play a significant role in determining TCO for each vehicle and should remain an R&D focus area. Overall, under the analysis' specified conditions, HDFC yard tractors have the potential to achieve cost parity with diesel yard tractors as early as 2025. For refuse trucks, HDFC refuse trucks have the potential to achieve cost parity with diesel and CNG refuse trucks in 2030 and 2040, respectively.

33 ADVANCED PROPULSION SYSTEMS↗

Solid State Solar Thermochemical Fuel (SoFuel) for Long Duration Storage

Efficient thermal storage systems, when coupled with renewable energy, enable the decarbonization of numerous industrial processes requiring high temperature steam or air, and provide a path for seasonal building heating, especially for colder climates. Existing thermal storage systems face a significant challenge due to losses inherent to all high temperature systems. A viable route to long-term storage is to use thermochemical reactions to convert concentrated solar energy to a fuel that is shelf-stable and can be stored at room temperature, thus eliminating losses associated with high temperature storage. The Solid-State Solar Thermochemical Fuel (SoFuel) technology developed by Michigan State University, Oregon State University, and Mississippi State University provides reactors and processes with minimal sensible heat losses and allows storing solar energy as a solid-state fuel at room temperature for long duration. The production of SoFuel occurs within a cylindrical cavity reduction chemical reactor that captures concentrated solar radiation from a solar field. Reactive magnesium manganese oxide (Mg-Mn-O) resides within the cylindrical cavity chemical reactor and undergoes thermal reduction as the temperature exceeds 1350°C. The thermally reduced Mg-Mn-O pellets (the SoFuel) are cooled down through a recuperative process and stored within a bin until used. The SoFuel can directly supply up to 1100°C heat to an adjacent power plant for electricity generation or industrial heating. Oxidation of SoFuel pellets occurs in a counter flow reactor and supplies heat to the user for electricity generation or industrial processing, after which the fuel is returned to the concentrating solar field where it is regenerated for re-use. Both reactors can be controlled well using a variety of strategies. With the low cost of the material, its cyclability, and the possibility of using the pelletized with on-sun reactors, or with electricity that would be curtailed, this project offers a viable option of medium- and long-term thermal energy storage.

14 SOLAR ENERGY↗

Solid State Solar Thermochemical Fuel (SoFuel) for Long Duration Storage

Efficient thermal storage systems, when coupled with renewable energy, enable the decarbonization of numerous industrial processes requiring high temperature steam or air, and provide a path for seasonal building heating, especially for colder climates. Existing thermal storage systems face a significant challenge due to losses inherent to all high temperature systems. A viable route to long-term storage is to use thermochemical reactions to convert concentrated solar energy to a fuel that is shelf-stable and can be stored at room temperature, thus eliminating losses associated with high temperature storage. The Solid-State Solar Thermochemical Fuel (SoFuel) technology developed by Michigan State University, Oregon State University, and Mississippi State University provides reactors and processes with minimal sensible heat losses and allows storing solar energy as a solid-state fuel at room temperature for long duration. The production of SoFuel occurs within a cylindrical cavity reduction chemical reactor that captures concentrated solar radiation from a solar field. Reactive magnesium manganese oxide (Mg-Mn-O) resides within the cylindrical cavity chemical reactor and undergoes thermal reduction as the temperature exceeds 1350°C. The thermally reduced Mg-Mn-O pellets (the SoFuel) are cooled down through a recuperative process and stored within a bin until used. The SoFuel can directly supply up to 1100C heat to an adjacent power plant for electricity generation or industrial heating. Oxidation of SoFuel pellets occurs in a counter flow reactor and supplies heat to the user for electricity generation or industrial processing, after which the fuel is returned to the concentrating solar field where it is regenerated for re-use. Both reactors can be controlled well using a variety of strategies. With the low cost of the material, its cyclability, and the possibility of using the pelletized with on-sun reactors, or with electricity that would be curtailed, this project offers a viable option of medium- and long-term thermal energy storage.

25 ENERGY STORAGE↗

Flowability of Crumbler Rotary Shear Size-Reduced Granular Biomass: An Experiment-Informed Modeling Study on the Angle of Repose

Biomass has potential as a carbon-neutral alternative to petroleum for chemical and energy products. However, complete replacement of fossil fuel is contingent upon efficient processes to eliminate undesirable characteristics of biomass, e.g., low bulk density, variability, and storage-induced quality problems. Mechanical size reduction via comminution is a processing operation to engineer favorable biomass flowability in handling. Crumbler rotary shear mill has been empirically demonstrated to produce more uniformly shaped particles with higher flowability than hammermilled biomass. This study combines modeling and experimentation to unveil fundamental understandings of the relation between granular particle characteristics and biomass flow behavior, which elucidate underlying mechanisms and guide selection of critical processing parameters. For this purpose, the impact of critical material attributes, including particle size (2–6 mm), particle shape (briquette, chip, clumped-sphere, cube, etc.), and surface roughness, on the angle of repose (AOR) of milled pine chips were investigated using discrete element method (DEM) simulations. Forest Concepts Crumbler rotary shear system is used to produce milled pine particles within the same size range considered in DEM simulations. AOR of different sets of these particles were measured experimentally to benchmark DEM results against experimental data. Specific energy consumption for the comminution of biomass with different particle size and moisture content are measured for technoeconomic analysis. Our results show that the smaller size (2 mm) of pine particle achieves better followability (i.e., smaller AOR) while the energy cost of comminution is significantly higher and bulk density is almost the same as the 6-mm pine particles. For the 2-mm particle size, Crumbles from veneer have better flow properties than Crumbles from chips. Contrarily, no significant difference was observed between the AOR of the two materials for the 6-mm particle size. Furthermore, from DEM simulations, mechanical interlocking between particles was found as a dominant factor in determining AOR of complex-shaped particles such as milled pine, which cannot be accurately captured by using simple particle shapes (e.g., mono-sphere) with a rolling resistance model. Conversely, clumped-sphere model alleviates this limitation without increasing computational cost significantly and can be used for accurate representation of biomass granular particles when simulating free-flow behavior.

09 BIOMASS FUELS↗

Updated sustainability status of cadmium telluride thin‐film photovoltaic systems and projections

This paper provides a comprehensive assessment of the up-to-date life-cycle sustainability status of cadmium-telluride based photovoltaic (PV) systems. Current production modules (Series 6 and Series 7) are analyzed in terms of their energy performance and environmental footprint and compared with the older series 4 module production and current single-crystalline Silicon (sc-Si) module production. For fixed-tilt systems with Series 6 modules operating under average US irradiation of 1800 kWh/m 2 /year, the global warming potential (GWP) is reduced from 16 g CO 2eq /kWh in Series 4 systems to 10 CO 2 eq /kWh in Series 6 systems. For operation in US-SW irradiation of 2300 kWh/m 2 /year, the GWP is reduced from 11 to 8 CO 2eq /kWh and for 1-axis tracking systems operating in Phoenix, Arizona, with point-of array irradiation of 3051 kWh/m 2 /year the GWP is reduced to 6.5 CO 2eq /kWh. Similar reductions have happened in all environmental indicators. Energy payback times (EPBT) of currently installed systems range from 0.6 years for fixed–tilt ground–mounted installations at average US irradiation at latitude tilt installations to 0.3 years for one-axis trackers at high US-SW irradiation, considering average fossil-fuel dominated electricity grids with fuel to electricity conversion efficiency of 0.3. The resulting energy return on energy investment (EROI) also depends on the conversion efficiency of the electricity grid and on the operation life expectance. For a 30-year operational life and grid conversion efficiency of 0.3, EROI ranges from 50 (at US average irradiation) to 70 for US-SW irradiation. The EROI declines with increased grid conversion efficiency; for CdTe PV operating in south California with grid conversion efficiency of 49%, the EROI is about 50 and is projected to fall to 30 when the state's 2030 target of 80% renewable energy penetration materializes. Material alternatives that show a potential of further reductions in degradation rates and materials for enhanced encapsulation that would enable longer operation lives have also been investigated. A degradation rate of 0.3%/year, which has been verified by accelerated testing, is assumed in 30-year scenarios; this is projected to be reduced to 0.2%/year in the near-term and potentially to 0.1%/year in the longer term. With such low degradation rates and enhanced edge-sealing, modules can last 40- to 50-years. Consequently, all impact indicators will be proportionally reduced while EROI will increase. This detailed LCA was conducted according to ISO standards and IEA PVPS Task 12 guidelines. Furthermore, the study revealed that the choices of system models, methods and temporal system boundaries can significantly impact the results and points out to the need to include assumptions regarding these choices in the “transparency in reporting” requirements listed in the IEA PVPS Task 12 Guidelines.

14 SOLAR ENERGY↗

Quantifying Firebrand Production and Transport Using the Acoustic Analysis of In-Fire Cameras

Firebrand travel and ignition of spot fires is a major concern in the Wildland-Urban Interface and in wildfire operations overall. Firebrands allow for the efficient breaching across fuel-free barriers such as roads, rivers and constructed fuel breaks. Existing observation-based knowledge on medium-distance firebrand travel is often based on single tree experiments that do not replicate the intensity and convective updraft of a continuous crown fire. Recent advances in acoustic analysis, specifically pattern detection, has enabled the quantification of the rate at which firebrands are observed in the audio recordings of in-fire cameras housed within fire-proof steel boxes that have been deployed on experimental fires. The audio pattern being detected is the sound created by a flying firebrand hitting the steel box of the camera. This technique allows for the number of firebrands per second to be quantified and can be related to the fire's location at that same time interval (using a detailed rate of spread reconstruction) in order to determine the firebrand travel distance. A proof of concept is given for an experimental crown fire that shows the viability of this technique. When related to the fire's location, key areas of medium-distance spotting are observed that correspond to regions of peak fire intensity. Trends on the number of firebrands landing per square metre as the fire approaches are readily quantified using low-cost instrumentation.

58 GEOSCIENCES↗

Porous materials for hydrogen storage

Hydrogen is a clean energy carrier and a promising candidate to realize carbon-neutral systems for a sustainable future because the combustion of hydrogen produces only water. The large-scale implementation of hydrogen, particularly in zero-emission hydrogen-powered fuel-cell automobiles, requires efficient hydrogen storage systems; however, the current on-board hydrogen storage technologies mainly rely on costly and potentially unsafe high-pressure compression strategies that reach pressures of up to 700 bar. Recently, solid-state porous materials, such as metal-organic frameworks, have emerged as sorbents that can conceivably store comparable amounts of hydrogen in a safer and more efficient manner relative to the current high-pressure storage technologies. Here this review summarizes the current progress on the development of state-of-the-art porous materials and their composites for hydrogen storage. We hope this work will inspire efforts toward creating next-generation hydrogen storage materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

Optimization of energy requirements for CO 2 post-combustion capture process through advanced thermal integration

The energy optimization modeling work described here was performed to determine efficiency improvements that could be achieved for existing coal-fired power plants to retrofit a partial CO 2 capture from the post-combustion flue gas for carbon sequestration through thermal integration. The work presented includes optimization of the mono-ethanol amine (MEA)-based post-combustion CO 2 capture to reduce energy requirements that could be achieved at existing power plants by thermal integration of the steam turbine cycle, boiler, CO 2 compression train and post-combustion CO 2 capture process to offset efficiency and capacity losses that would be incurred by retrofit or implementation of post-combustion CO 2 capture. Furthermore, partial CO 2 capture, involving treatment of less than 100% of the flue gas leaving the plant and modular design of the CO 2 scrubbing system, was also investigated. Thermal integration of the steam turbine cycle with boiler and CO 2 compression train improved cycle and plant performance and offset, in part, the negative effects of post-combustion CO 2 capture. The best-analyzed integration options improved gross power output by 5% and net unit efficiency by 1.57%, relative to the conventional MEA process. Operating with 40% CO 2 capture increased gross power output by 11.6–14% (depending on the MEA thermal integration option), relative to the conventional MEA integration and 90% CO 2 capture. The improvement in net unit performance is larger compared to the improvement in turbine cycle performance because of the CO 2 compression work, which is also reduced by partial CO 2 capture.

42 ENGINEERING↗

The effect of water vapor on surface oxygen exchange kinetics of thin film (La,Sr)(Co,Fe)O 3-δ

Oxygen reduction and transport in electrochemical applications are strongly affected by the reactant gas composition, including impurities such as water. Understanding the relationship between oxygen reactivity and humidity is key for attaining stability and high efficiency of solid oxide fuel cells, which are especially attractive for transportation applications as low emission power generation devices. Both short- and long-term effects of moisture have previously been associated with use of ambient air. To better understand these effects, we study oxygen exchange kinetics at the cathode surface and the cathode/electrolyte interface using La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ (LSCF) epitaxial thin films as a model-surface system. In situ synchrotron X-ray techniques evaluate the oxygen reduction reaction (ORR) kinetics in response to environmental variables. The results suggest a clear enhancement of the ORR rate upon short term exposure of the perovskite-structured films to water. Finally, on the basis of these measurements, along with in situ X-ray characterization of Sr segregation and computational first-principles studies, we suggest a model for this increased ORR activity that may lead to further improvements by stabilizing active cathode surface configurations.

25 ENERGY STORAGE↗

ZnTiN 2 as an Electron-Selective, Protective Layer on Si Photocathodes

Photoelectrochemical production of fuels requires photoelectrodes that efficiently convert sunlight to electrochemical energy by producing photovoltage and photocurrent and maintain this ability over time under a variety of pH, illumination, and applied bias conditions. Work in the photovoltaic community has demonstrated that interfaces with high charge carrier selectivity provide high photovoltages. This offers a co-design opportunity to create semiconductor photoelectrodes with contact layers that are both carrier-selective and offer protection from degradation in aqueous solutions. In this work, we explored the ternary nitride ZnTiN 2 as an electronselective, protective layer for Si-based photocathodes. We demonstrated that ZnTiN 2 formed a heterojunction with p-type Si that facilitated electron movement toward the ZnTiN 2 surface for light-driven reduction reactions. Across a variety of electrolyte conditions, ZnTiN 2 /Si produced an open circuit voltage of ca. 400 mV vs the solution potential, while bare Si produced 220−480 mV vs the solution potential depending on conditions. ZnTiN 2 was also shown to protect Si over 72 h at open circuit in the dark in 0.1 M KHCO 3 aqueous solution at pH 10.5, with a 2.4% loss in open circuit voltage compared to a 17% loss for unprotected Si. A protective effect was also observed under illumination during methyl viologen reduction at pH 3.5 for 21 h, with a 2.5% loss in open circuit voltage observed for ZnTiN 2 /Si compared to a 25% loss in open circuit voltage for unprotected Si under the same conditions. Elemental characterization revealed the presence of oxides on the surface of ZnTiN 2 that are consistent with the Pourbaix diagram after photoelectrochemical operation; these oxides appeared to support durability without hindering charge carrier extraction to drive electrochemical work. This work highlights the promise of ZnTiN 2 for durable photoelectrochemical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗