Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Cosmic microwave background and inflation in multi-fractional spacetimes

We use FIRAS and Planck 2015 data to place observational bounds on inflationary scenarios in multi-fractional spacetimes with q-derivatives. While a power-law expansion in the geometric time coordinate is subject to the usual constraints from the tensor-to-scalar ratio, model-independent best fits of the black-body and scalar spectra yield upper limits on the free parameters of the multi-fractal measure of the theory. When the measure describing the fractal spacetime geometry is non-oscillating, information on the CMB black-body spectrum places constraints on the theory independent from but weaker than those obtained from the Standard Model, astrophysical gravitational waves and gamma-ray bursts (GRBs). When log oscillations are included and the measure describes a discrete fractal spacetime at microscopic scales, we obtain the first observational constraints on the amplitudes of such oscillations and find, in general, strong constraints on the multi-scale geometry and on the dimension of space. These results complete the scan and reduction of the parameter space of the theory. Black-body bounds are obtained also for the theory with weighted derivatives.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced nanoscale characterization of aluminum nanoparticles with modified surface morphology via atmospheric helium and carbon monoxide plasmas

Aluminum nanoparticles (nAl) have the potential as energetic additives in explosive/propellant formulations. Scalable methodologies must be pursued to mitigate the inactive amorphous alumina shell surrounding the active aluminum (Al) core with modified surface morphology and chemistry for increased combustion effects. This work explores the feasibility of making reactive core/shell nAl with thinned oxide shells and modified surface coatings via a two-step atmospheric plasma surface treatment process in a custom dielectric barrier discharge plasma reactor. The commercial nAl of nominal average size similar to 40-60nm was first treated with helium (He) followed by He/carbon monoxide (CO) plasmas for different durations. The resultant samples were characterized via high-resolution transmission electron microscopy (HRTEM) and Fourier transform IR (FTIR) spectra. HRTEM images revealed sporadic patchy gamma -alumina deposits on particle surfaces and in gaps among particles for all samples, suggesting the non-uniform plasma effects of the He/CO glow. Nanoscale chemical analyses via scanning transmission electron microscopy elemental mapping and x-ray energy dispersive spectroscopy were further performed. Although no carbon-associated structure appeared in electron energy loss spectroscopy (EELS) spectra, the presence of carbonaceous materials was confirmed as a thin dispersive layer evenly distributed on the nAl surface suggesting either its amorphous nature or is present at a level insufficient to generate satisfactory EELS spectra. The trend of intensity profiles for key elements acquired by drawing lines across a single particle on the elemental maps confirmed that carbonaceous materials only existed on the surface and they were most likely carboxylates that increased with increased He/CO treatment duration, as evident by FTIR results. Finally, this work demonstrated the success of atmospheric plasma-treated reactive nAl with comprehensively characterized surface features via advanced microscopy and spectroscopy.

36 MATERIALS SCIENCE↗

Optical Spectra of Gamma-Irradiated LiF Crystals with Anisotropic Lithium Nanoparticles

The optical response of Li anisotropic defects and nanoparticles from three faces of cubic LiF crystals with 10-mm edges to γ radiation from a {sup 60}Со source with doses of 10{sup 5}–10{sup 9} R at 320 K in air is studied. After a maximum dose of 10{sup 9} R, scanning electron microscopy revealed submicron metal lithium flakes ordered into long parallel nanofilaments. The resonance absorption band, which shifts from 272 to 295 nm with increasing dose, is assigned to lithium nanocolloids in the (110) plane. The band at 202–225 nm observed only from the (100) face narrows at doses below 10{sup 5} R and is assigned to diatomic fluorine molecules in interstitial sites. The appearance of the 209–212–215-nm triplets at 2.7 × 10{sup 5} R from the (100) plane and the 211–213–215-nm triplets at 0.9 × 10{sup 5} R from the (010) plane is related to radiation-induced axially symmetric bipolarons with a high oscillator strength. The splitting of the 445-nm band into a 438–445–450-nm triplet is observed only for the (010) plane after a dose of 10{sup 6} R and is related to surface plasmon polaritons (longitudinal and transverse) of elongated Li nanoparticles. The (F{sub 2}–F{sub 3}) complexes are oriented in the most imperfect (111) plane and are seen along three cubic axes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Radiation Tolerance Studies of Commercial Strippable Coatings and Fixatives used for Decontamination - 18642

A number of commercially available products, designed for use as strippable coating and fixatives for decontamination purposes, were tested to determine their tolerability to high radiation fields and how they potentially degrade. Each product was cured and exposed to γ-radiation from a Co-60 source, up to a total dose of 500 kGy. Obvious physical colour changes and deformities were detected by visual inspection, and images captured by scanning electron microscope (SEM) showed major differences post-irradiation in some coatings. Other physical changes to the coatings were measured using Fourier-transform infrared spectroscopy (FT-IR), Raman spectroscopy, and energy-dispersive X-ray spectroscopy (EDS); both pre- and post-irradiation. FT-IR suggested that some chemical changes were taking place in the coatings, in particular the C-H bonds and the fingerprint region appeared to be drastically altered in some coatings. EDS data indicated an increase in surface oxygen content as a result of irradiation in the majority of the samples. Additionally, coating samples were subjected to analysis by gas chromatography mass spectrometry (GCMS) in order to determine the evolved gases. The GC-MS results show that short chain hydrocarbons are produced to some degree in all the coatings during irradiation. Finally, three of the best performing coatings were selected and were irradiated using an ion beam, mimicking Pu alpha particles (with energy of around 5.25 MeV). Using the Dalton Cumbrian Facility's 5 MV tandem accelerator, coating samples were irradiated by ∼5.25 MeV He{sup 2+} particles to total dose of approximately 500 kGy. Samples were analysed using SEM, FT-IR, Raman and EDS, as was done for the gamma irradiated samples, allowing a comparison to be made between α-particle and γ-ray damage. Results from the alpha and gamma irradiations showed many similarities for the comparable assessments. A number of spectral changes observed in the FT-IR analysis were consistent across both γ-ray and α-particle irradiated samples. While there were some differences, these may be attributed to the conditions under which the irradiations were carried out. The observed similarities may allow for the inference of alpha degradation by Co-60 gamma irradiation as a more easily accessible method for determining the extent of radiolytic damage. Furthermore, gamma irradiation allows for additional analysis that is currently otherwise not possible to achieve with ion-beam exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Differential Scanning Calorimetry of Volatile-Bearing Iron Minerals Under Mars-Like Pressures: New Insights Into Energetics and Mechanisms of Thermal Decomposition

In this study, we have examined the thermal decomposition of two volatile-bearing iron minerals, in particular, lepidocrocite (gamma-FeOOH) and siderite (FeCO3), under Mars-like pressures. Both minerals exhibit different enthalpic events during their decomposition at reduced atmospheric pressures when compared to those at ambient pressure. These differences in energetics are related to the mechanisms of thermal decomposition at Mars-like pressures. Such knowledge regarding the thermal stability of volatile-bearing minerals on Mars will provide useful information for planetary surface processes.

Lin, I.-C.↗

Optimized blind gamma-ray pulsar searches at fixed computing budget

The sensitivity of blind gamma-ray pulsar searches in multiple years worth of photon data, as from the Fermi LAT, is primarily limited by the finite computational resources available. Addressing this 'needle in a haystack' problem, here we present methods for optimizing blind searches to achieve the highest sensitivity at fixed computing cost. For both coherent and semicoherent methods, we consider their statistical properties and study their search sensitivity under computational constraints. The results validate a multistage strategy, where the first stage scans the entire parameter space using an efficient semicoherent method and promising candidates are then refined through a fully coherent analysis. We also find that for the first stage of a blind search incoherent harmonic summing of powers is not worthwhile at fixed computing cost for typical gamma-ray pulsars. Further enhancing sensitivity, we present efficiency-improved interpolation techniques for the semicoherent search stage. Via realistic simulations we demonstrate that overall these optimizations can significantly lower the minimum detectable pulsed fraction by almost 50% at the same computational expense.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-J-208: Prompt Gamma Imaging-Based Prediction of Bragg Peak Position for Realistic Treatment Error Scenarios

Purpose: To quantify the accuracy in predicting the Bragg peak position using simulated in-room measurements of prompt gamma (PG) emissions for realistic treatment error scenarios that combine several sources of errors. Methods: Prompt gamma measurements by a knife-edge slit camera were simulated using an experimentally validated analytical simulation tool. Simulations were performed, for 143 treatment error scenarios, on an anthropomorphic phantom and a pencil beam scanning plan for nasal cavity. Three types of errors were considered: translation along each axis, rotation around each axis, and CT-calibration errors with magnitude ranging respectively, between −3 and 3 mm, −5 and 5 degrees, and between −5 and +5%. We investigated the correlation between the Bragg peak (BP) shift and the horizontal shift of PG profiles. The shifts were calculated between the planned (reference) position and the position by the error scenario. The prediction error for one spot was calculated as the absolute difference between the PG profile shift and the BP shift. Results: The PG shift was significantly and strongly correlated with the BP shift for 92% of the cases (p<0.0001, Pearson correlation coefficient R>0.8). Moderate but significant correlations were obtained for all cases that considered only CT-calibration errors and for 1 case that combined translation and CT-errors (p<0.0001, R ranged between 0.61 and 0.8). The average prediction errors for the simulated scenarios ranged between 0.08±0.07 and 1.67±1.3 mm (grand mean 0.66±0.76 mm). The prediction error was moderately correlated with the value of the BP shift (p=0, R=0.64). For the simulated scenarios the average BP shift ranged between −8±6.5 mm and 3±1.1 mm. Scenarios that considered combinations of the largest treatment errors were associated with large BP shifts. Conclusion: Simulations of in-room measurements demonstrate that prompt gamma profiles provide reliable estimation of the Bragg peak position for complex error scenarios. Yafei Xing and Luiza Bondar are funded by BEWARE grants from the Walloon Region. The work presents simulations results for a prompt gamma camera prototype developed by IBA.

60 APPLIED LIFE SCIENCES↗

Structural and optical effects induced by gamma irradiation on NdPO{sub 4}: X-ray diffraction, spectroscopic and luminescence study

Highlights: • Inorganic NdPO{sub 4} crystal was grown first time using potassium polyphosphate (K{sub 6}P{sub 4}O{sub 13}) flux. • NdPO{sub 4} crystal is insoluble in water, non-hygroscopic and high radiation resistance favoring for actinides host. • Actinide immobilization can be made at 1273 K. • High yield of 1061 nm photon emission. - Abstract: Rare earth orthophosphate (NdPO{sub 4}) monazite single crystals were grown using high temperature flux growth method employing K{sub 6}P{sub 4}O{sub 13} (K{sub 6}) as molten solvent. Their structural parameters were studied using single crystal X-ray diffraction (XRD) method. The grown crystals were examined by SEM and EDX techniques for their homogeniousity and inclusion in the crystals. The influence of gamma irradiation in structural and optical absorption properties were studied by the powder XRD, FTIR and reflectance spectroscopy. The effect of gamma irradiation on luminescence properties was recorded. No significant structural change is observed up to 150 kGy gamma dose. The gamma ray induced charge trap in the crystal was saturated to 40 kGy dose. The luminescence intensity decreases with an increase in the irradiation. The emission of luminescence intensity stabilizes above 40 kGy gamma dose.

36 MATERIALS SCIENCE↗

Gamma Knife irradiation method based on dosimetric controls to target small areas in rat brains

Purpose: Targeted and whole-brain irradiation in humans can result in significant side effects causing decreased patient quality of life. To adequately investigate structural and functional alterations after stereotactic radiosurgery, preclinical studies are needed. The purpose of this work is to establish a robust standardized method of targeted irradiation on small regions of the rat brain. Methods: Euthanized male Fischer rats were imaged in a stereotactic bed, by computed tomography (CT), to estimate positioning variations relative to the bregma skull reference point. Using a rat brain atlas and the stereotactic bregma coordinates obtained from CT images, different regions of the brain were delimited and a treatment plan was generated. A single isocenter treatment plan delivering ≥100 Gy in 100% of the target volume was produced by Leksell GammaPlan using the 4 mm diameter collimator of sectors 4, 5, 7, and 8 of the Gamma Knife unit. Impact of positioning deviations of the rat brain on dose deposition was simulated by GammaPlan and validated with dosimetric measurements. Results: The authors’ results showed that 90% of the target volume received 100 ± 8 Gy and the maximum of deposited dose was 125 ± 0.7 Gy, which corresponds to an excellent relative standard deviation of 0.6%. This dose deposition calculated with GammaPlan was validated with dosimetric films resulting in a dose-profile agreement within 5%, both in X- and Z-axes. Conclusions: The authors’ results demonstrate the feasibility of standardizing the irradiation procedure of a small volume in the rat brain using a Gamma Knife.

60 APPLIED LIFE SCIENCES↗

SU-F-T-568: QA of a Multi-Target Multi-Dose VMAT SRS

Purpose: To, experimentally, corroborated the prescribed doses utilizing dosimeters (e.g. films and TLDs) that can provide high spatial resolution, allow dose measurement of multiple targets at once, and provide accurate dosimetric results. Methods: A single-isocenter 6FFF SRS VMAT plan consisting of one 358° arc at 0° couch angle and four 179° arcs at 30°, 60°, 330° and 300° couch angles respectively, was generated in ECLIPSE v.11 using a Rando-Alderson anthropomorphic head phantom CT study. This plan was a reproduction of a clinical plan generated for a stage-IV melanoma patient diagnosed with 19 intracranial lesions. The phantom was loaded with axially mounted (between phantom slabs) Gafchromic EBT3 film and TLDs strategically positioned within various target volumes. Film and TLDS were calibrated according to established protocols. Target prescription doses were 16 Gy (3cc≤, 3 lesions), 18 Gy (∼1–3cc, 10 lesions) and 20 Gy (≤1cc, 6 lesions). Phantom setup was verified through CBCT imaging prior to irradiation. Gafchromic films were scanned in transmission mode and TLDs were read, respectively, ∼24 hrs after irradiation. Results: Dose calibrated Gafchromic film data were compared to the ECLIPSE calculated data using a 3% / 3mm gamma function analysis. Results for the gamma values were 96–99% in agreement with the calculated data and with 84–90% of the film pixels within the 3% dose difference. TLD data showed a dose difference of 0.4–8% while the film data for those same locations yielded a difference of 0.4–4%. It was observed that the highest dose discrepancies correlated with the location of the small volume targets. Conclusion: Overall this study corroborated that a VMAT SRS treatment, employing various treatment table rotations and arcs, to multiple intracranial lesions with multiple dose prescriptions can be delivered accurately with the existing radiotherapy technology.

60 APPLIED LIFE SCIENCES↗

Independent Verification Survey Summary and Results for Sub-Slab Soils Associated with the Former Building K-33, Oak Ridge, Tennessee (Final Report)

At DOE’s request, ORAU conducted confirmatory surveys of the K-33 sub-slab soil during the period of August 2011 through May 2012. The survey activities included visual inspections and measurement and sampling activities. LSRS was forthcoming with information relating to surface scan results. Scans performed by the contractor were of adequate coverage and overall data appear to represent actual site conditions. However, the LSRS technicians failed to identify several areas of elevated direct gamma radiation. Most of the samples taken by ORAU at locations of elevated instrument response were above the remediation concentration for one or more radionuclides of concern (ROC). The contractor was, however, quick to perform additional remediation of areas identified to have contamination above the guidelines. Further investigation by ORAU was not requested once additional remediation was completed. It is presumed the remediation contractor’s future PCCR will present detailed and conclusive evidence that K-33 sub-slab soils either comply or do not comply with record of decision (ROD) criteria. However, ORAU concludes, based on both independent verification (IV) data and data provided by LSRS, that the remediation contractor followed appropriate and applicable procedures and that the associated data adequately represent site conditions.

54 ENVIRONMENTAL SCIENCES↗

Mechanical and structural characterizations of gamma- and alpha-alumina nanofibers

We investigate the applicability of alumina nanofibers as a potential reinforcement material in ceramic matrix compounds by comparing the mechanical properties of individual nanofibers before and after annealing at 1400 °C. Mechanical testing is performed inside a scanning electron microscope (SEM), which enables observation in real time of the deformation and fracture of the fibers under loading, thereby providing a close-up inspection of the freshly fractured area in vacuum. Improvement of both the Young's modulus and the breaking strength for annealed nanofibers is demonstrated. Mechanical testing is supplemented with the structural characterization of the fibers before and after annealing using SEM, transmission electron microscopy and X-ray diffraction methods. - Highlights: • Mechanical properties of individual alumina nanofibers were measured using in situ SEM cantilevered beam bending technique. • Improvement of mechanical properties of the alumina fibers after annealing at 1400 °C is demonstrated. • Formation of branched structures is demonstrated and their mechanical properties are studied. • XRD and electron microscopy were used for structural characterization of untreated and annealed nanofibers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Gamma-ray burst observations by the HEAO-3 high-resolution gamma-ray spectrometer

Special attention is given to two bursts occurring on November 16, 1979. Because of the close temporal coincidence of the two events, the possibility that both originated from a single celestial source is considered, as is the possibility that the scanning motion of HEAO-3 (nominal spin period, 20 min) was such as to exclude the first from the (approximately 30 deg FWHM) field of view of the germanium detectors and include the second. Directional data from the relative response of the shield pieces and earth occultation constraint are found to be consistent with this interpretation, and high-resolution spectral data from the second burst are discussed in this light. It is noted that recent unpublished analyses of long-baseline timing data from interplanetary spacecraft reveal that the response in the HEAO high-resolution detectors is probably earth albedo scattering. This, it is noted, can be an important systematic effect in low-earth orbit.

Wheaton, W. A.↗

Evaluation of camera-based freehand SPECT in preoperative sentinel lymph node mapping for melanoma patients

Assessment of lymphatic status via sentinel lymph node (SLN) biopsy is an integral and crucial part of melanoma surgical oncology. The most common technique for sentinel node mapping is preoperative planar scintigraphy of an injected gamma-emitting lymphatic tracer followed by intraoperative node localization using a non-imaging gamma probe with auditory feedback. In recent years, intraoperative visualization of SLNs in 3D has become possible by coupling the probe to an external system capable of tracking its location and orientation as it is read out, thereby enabling computation of the 3D distribution of the tracer (freehand SPECT). In this project, the non-imaging probe of the fhSPECT system was replaced by a unique handheld gamma camera containing an array of sodium iodide crystals optically coupled to an array of silicon photomultipliers (SiPMs). A feasibility study was performed in which preoperative SLN mapping was performed using camera fhSPECT and the number of detected nodes was compared to that visualized by lymphoscintigraphy, probe fhSPECT, and to the number ultimately excised under non-imaging probe guidance. Among five subjects, SLNs were detected in nine lymphatic basins, with one to five SLNs detected per basin. A basin-by-basin comparison showed that the number of SLNs detected using camera fhSPECT exceeded that using lymphoscintigraphy and probe fhSPECT in seven of nine basins and five of five basins, respectively. (Probe fhSPECT scans were not performed for four basins.) It exceeded the number excised under non-imaging probe guidance for seven of nine basins and equaled the number excised for the other two basins. Freehand SPECT using a prototype SiPM-based gamma camera demonstrates high sensitivity for detection of SLNs in a preoperative setting. Camera fhSPECT is a potential means for efficiently obtaining real-time 3D activity distribution maps in applications such as image-guided percutaneous biopsy, and surgical SLN biopsy or radioguided tumor excision.

60 APPLIED LIFE SCIENCES↗

Changes realized from extended bit-depth and metal artifact reduction in CT

Purpose: High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosimetry. Methods: Extended CT to electron density (CT-ED) curves were derived from a tissue characterization phantom with titanium and stainless steel inserts scanned at 90-140 kVp for 12- and 16-bit reconstructions. MAR was applied to sinogram data (Brilliance BigBore CT scanner, Philips Healthcare, v.3.5). Monte Carlo simulation (MC-SIM) was performed on a simulated double hip prostheses case (Cerrobend rods embedded in a pelvic phantom) using BEAMnrc/Dosxyz (400 000 0000 histories, 6X, 10 Multiplication-Sign 10 cm{sup 2} beam traversing Cerrobend rod). A phantom study was also conducted using a stainless steel rod embedded in solid water, and dosimetric verification was performed with Gafchromic film analysis (absolute difference and gamma analysis, 2% dose and 2 mm distance to agreement) for plans calculated with Anisotropic Analytic Algorithm (AAA, Eclipse v11.0) to elucidate changes between 12- and 16-bit data. Three patients (bony metastases to the femur and humerus, and a prostate cancer case) with metal implants were reconstructed using both bit depths, with dose calculated using AAA and derived CT-ED curves. Planar dose distributions were assessed via matrix analyses and using gamma criteria of 2%/2 mm. Results: For 12-bit images, CT numbers for titanium and stainless steel saturated at 3071 Hounsfield units (HU), whereas for 16-bit depth, mean CT numbers were much larger (e.g., titanium and stainless steel yielded HU of 8066.5 {+-} 56.6 and 13 588.5 {+-} 198.8 for 16-bit uncorrected scans at 120 kVp, respectively). MC-SIM was well-matched between 12- and 16-bit images except downstream of the Cerrobend rod, where 16-bit dose was {approx}6.4% greater than 12-bit. Absolute film dosimetry in a region downstream of a stainless steel rod revealed that 16-bit calculated dose, with and without MAR, agreed more closely with film results (1%-2% less than film) as compared to 12-bit reconstructions (5.6%-6.5% less than film measurements). Gamma analysis revealed that 16-bit dose calculations were better matched to film results than 12-bit ({approx}10% higher pass rates for 16-bit). Similar results were observed in two patient cases; the largest discrepancy was observed for a femur case where 12-bit doses, both with and without MAR correction, were 6-7 Gy lower ({approx}17%-20% of the prescription dose) as compared to 16-bit dose calculations. However, when beams are not directly traversing metal, such as a prostate cancer case with bilateral hip prostheses; the impact of 16-bit reconstruction was diminished. Conclusions: These results suggest that it may be desirable to implement 16-bit MAR-corrected images for treatment planning purposes, which can provide a more accurate dosimetric approach coupled with improved visualization by suppression of CT artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Three-Dimensional Dose Verification for Intensity-Modulated Radiation Therapy in the Radiological Physics Centre Head-and-Neck Phantom Using Optical Computed Tomography Scans of Ferrous Xylenol-Orange Gel Dosimeters

Purpose: To extend the Radiological Physics Centre (RPC) intensity-modulated radiation therapy dose verification protocol to three dimensions using optical computed tomography (CT) scans of ferrous xylenol-orange (FX) gels. Methods and Materials: The dosimetry insert in the RPC head-and-neck phantom was replaced with an FX cylindrical gel dosimeter. Two gels were calibrated, independently irradiated with 6-MV X-ray beams and scanned using laser and cone-beam (Vista{sup TM}) optical CT, respectively. For matching dose slices, measured dose distributions were compared with Pinnacle{sup 3} computed distributions. Results: Within high-dose regions and low gradients, doses measured using laser CT were 2% to 3% less than the computed dose, whereas with cone-beam CT they were 4% to 5% less. Inside the central 90% of the gel cylinder diameter, the fraction of voxels satisfying the two-dimensional gamma analysis (5% dose difference, 3-mm distance to agreement) with laser-beam- and cone-beam-measured dose distributions were 98.4% and 99.0%, respectively. A three-dimensional gamma analysis with cone-beam data revealed that 96.7% of voxels within the central 90% gel volume satisfied the above criteria. Within the axial and sagittal planes through the primary planning target volume (PTV), computed and measured doses using GAFChromic EBT film (RPC measured) and cone-beam scanned FX gel generally agreed. At equivalent points in the planning target volumes, computed, thermoluminescent dosimeter (RPC-measured), and gel point doses agreed to within 5.1% in absolute dose. Conclusions: Laser and cone-beam CT yield comparable dose distributions in high-dose regions. The RPC head phantom and optical CT-scanned FX gels can be used for accurate intensity-modulated radiation therapy dose verification in three dimensions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ADONIS, high count-rate HP-Ge {gamma} spectrometry algorithm: Irradiated fuel assembly measurement

ADONIS is a digital system for gamma-ray spectrometry, developed by CEA. This system achieves high count-rate gamma-ray spectrometry with correct dynamic dead-time correction, up to, at least, more than an incoming count rate of 3.10{sup 6} events per second. An application of such a system at AREVA NC's La Hague plant is the irradiated fuel scanning facility before reprocessing. The ADONIS system is presented, then the measurement set-up and, last, the measurement results with reference measurements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gamma imaging and mapping advancements

The Savannah River National Lab (SRNL) in partnership with Los Alamos National Lab (LANL) developed an in-situ GrayQb™ radiation mapping device eliminating the need to remove the radiation sensitive phosphor storage plate (PSP) from the device for scanning between exposures. By incorporating a customized version of the LANL patented MiniMax camera-based PSP reader system into the GrayQb™ housing, the exposed PSP can now be read in-situ and digitally transmitted to a remote computer for viewing. The ability to generate radiation contour maps showing source locations and relative radiological levels present in an area has high utility for targeting clean-up efforts, maintaining worker ALARA, determining leak locations and radiological situational awareness. In-situ GrayQb™ reduces the number of required interactions with the device providing deployment cost savings, increasing personnel safety and removing human handling errors during the manual scan process. Additionally, by negating the need for an external scanner, the device becomes more mobile. Other upgrades to the device included identification of a more sensitive imaging medium and incorporation of a dual pinhole rendering the device physically capable of obtaining 3D images. Laboratory tests with Am-241 sources using a mockup of the in-situ GrayQ™, successfully demonstrated the ability to digitally capture radiation source information using the dual pinhole and camera-based PSP reader.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗