Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Effect of Exercise Training and +Gz Acceleration Training on Men

Countermeasures for reduction in work capacity (maximal oxygen uptake and strength) during spaceflight and enhanced orthostatic intolerance during re-entry, landing and egress from the return vehicle are continuing problems. The purpose for this study was to test the hypothesis that passive-acceleration training; supine, interval, exercise plus acceleration training and exercise combined with acceleration training would improve orthostatic tolerance in ambulatory men; and that addition of the aerobic exercise conditioning would not alter this improved tolerance from that of passive-acceleration training. Seven men (24-38 yr) underwent "Passive" training on the Ames human-powered centrifuge (HPC) for 30 min, "Exercise" training on the cycle ergometer with constant +Gz acceleration; and "Combined" exercise training at 40% to 90% of the HPC +Gz(max) exercise level. Maximal supine exercise loads increased significant (P<0.05) by 8.3% (Passive), 12.6% (Exercise), and by 15.4% (Combined) after training, but their post-training maximal oxygen uptakes and maximal heart rates were unchanged. Maximal time to fatigue (endurance) was unchanged with Passive was increased (P<0.05) with Exercise and Combined training. Thus, the exercise in the Exercise and Combined training Phases resulted in greater maximal loads and endurance without effect on maximal oxygen uptake or heart rate. There was a 4% to 6% increase (P<0.05) in all four quadriceps muscle volumes (right and left) after post-Combined training. Resting pre-tilt heart rate was elevated by 12.9% (P<0.05) only after Passive training suggesting that the exercise training attenuated the HR response. Plasma volume (% Delta) was uniformly decreased by 8% to 14% (P<0.05) at tilt-tolerance pre- vs. post-training indicating essentially no effect of training on the level of hypovolemia. Post-training tilt-tolerance time and heart rate were increased (P<0.05) only with Passive training by 37.8% and by 29.1%, respectively. Thus, addition of exercise training appeared to attenuate the increased Passive tilt-tolerance.

Greenleaf, John E.↗

Cardiac and Vascular Function in Bedrested Volunteers: Effects of Artificial Gravity Training

Cardiovascular effects of an artificial gravity (AG) countermeasure on deconditioned male volunteers were studied. In two groups of men we measured cardiovascular parameters at rest and in response to 30 minutes of 80 deg. head up tilt (HUT) before, at the end of, and four days following 21 days of 6 deg. head down bed rest (HDBR). One group (N=7) underwent no countermeasure while the other (N=8) received a daily, one hour, dose (2.5 gz at the foot, decreasing to 1.0 gz at the heart) of AG training on the Johnson Space Center short radius centrifuge. Cardiovascular parameters measured included heart rate, blood pressure, stroke volume, cardiac output, peripheral vascular resistance, plasma volume shifts, and vasoactive hormones. Untrained subjects exhibited shorter tilt survival (on average 8 minutes shorter) compared to trained subjects. By the end of bed rest, mean heart rate (MHR) was elevated in both groups (both supine and during tilt). In addition, treated subjects demonstrated lower, tilt-induced, increases in MHR four days following HDBR, indicating a more rapid return to pre bed rest conditions. Results from an index of autonomic balance (percentage of MHR spectral power in the respiratory frequency range) in control of heart rate are consistent with the interpretation that parasympathetic nervous system withdrawal was responsible for both tilt- and bed rest-induced increases in MHR. Our data support our pre-study hypothesis that AG treatment would lessen cardiovascular effects of deconditioning in bed rested men and suggest that AG should be further pursued as a space flight countermeasure.

Meng, M.↗

Validation of Cardiovascular Parameters During NASA's Functional Task Test

Microgravity-induced physiological changes, including cardiovascular deconditioning may impair crewmembers f capabilities during exploration missions on the Moon and Mars. The Functional Task Test (FTT), which will be used to assess task performance in short and long duration astronauts, consists of 7 functional tests to evaluate crewmembers f ability to perform activities to be conducted in a partial-gravity environment or following an emergency landing on Earth. The Recovery from Fall/Stand Test (RFST) tests both the subject fs ability to get up from a prone position and orthostatic intolerance. PURPOSE: Crewmembers have never become presyncopal in the first 3 min of quiet stand, yet it is unknown whether 3 min is long enough to cause similar heart rate fluctuations to a 5-min stand. The purpose of this study was to validate and test the reliability of heart rate variability (HRV) analysis of a 3-min quiet stand. METHODS: To determine the validity of using 3 vs. 5-min of standing to assess HRV, 7 healthy subjects remained in a prone position for 2 min, stood up quickly and stood quietly for 6 min. ECG and continuous blood pressure data were recorded. Mean R-R interval and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the complete FTT on separate days, including the RFST with a 3-min stand test. Analysis of variance (ANOVA) was performed on the HRV measures. RESULTS: Spectral HRV measures reflecting autonomic activity were not different (p>0.05) during the 0-3 and 0-5 min segment (mean R-R interval: 738+/-74 ms, 728+/-69 ms; low frequency to high frequency ratio: 6.5+/-2.2, 7.7+/-2.7; normalized high frequency: 0.19+/-0.03, 0.18+/-0.04). The average coefficient of variation for mean R-R interval, systolic and diastolic blood pressures in the prone position and stand test were less than 8% for the test sessions. ANOVA results yielded a greater inter-subject variability (p.0.006) than inter-session variability (p>0.05) for HRV in the stand test. CONCLUSION: These studies show that a 3 minute stand delivers repeatable cardiovascular heart rate and BP data in the context of this larger series of tests such as the FTT.

Arzeno, N. M.↗

Microwave Treatment for Cardiac Arrhythmias

NASA seeks to transfer the NASA developed microwave ablation technology, designed for the treatment of ventricular tachycardia (irregular heart beat), to industry. After a heart attack, many cells surrounding the resulting scar continue to live but are abnormal electrically; they may conduct impulses unusually slowly or fire when they would typically be silent. These diseased areas might disturb smooth signaling by forming a reentrant circuit in the muscle. The objective of microwave ablation is to heat and kill these diseased cells to restore appropriate electrical activity in the heart. This technology is a method and apparatus that provides for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In comparison with other methods that involve direct-current pulses or radio frequencies below 1 GHz, this method may prove more effective in treating ventricular tachycardia. This is because the present method provides for greater control of the location, cross-sectional area, and depth of a lesion via selection of the location and design of the antenna and the choice of microwave power and frequency.

Hernandez-Moya, Sonia↗

Nature's Autonomous Oscillators

Nonlinearity is required to produce autonomous oscillations without external time dependent source, and an example is the pendulum clock. The escapement mechanism of the clock imparts an impulse for each swing direction, which keeps the pendulum oscillating at the resonance frequency. Among nature's observed autonomous oscillators, examples are the quasi-biennial oscillation and bimonthly oscillation of the Earth atmosphere, and the 22-year solar oscillation. The oscillations have been simulated in numerical models without external time dependent source, and in Section 2 we summarize the results. Specifically, we shall discuss the nonlinearities that are involved in generating the oscillations, and the processes that produce the periodicities. In biology, insects have flight muscles, which function autonomously with wing frequencies that far exceed the animals' neural capacity; Stretch-activation of muscle contraction is the mechanism that produces the high frequency oscillation of insect flight, discussed in Section 3. The same mechanism is also invoked to explain the functioning of the cardiac muscle. In Section 4, we present a tutorial review of the cardio-vascular system, heart anatomy, and muscle cell physiology, leading up to Starling's Law of the Heart, which supports our notion that the human heart is also a nonlinear oscillator. In Section 5, we offer a broad perspective of the tenuous links between the fluid dynamical oscillators and the human heart physiology.

Mayr, H. G.↗

Modelflow Estimates of Stroke Volume Do Not Correlate With Doppler Ultrasound Estimates During Upright Posture

Orthostatic intolerance affects 60‐80% of astronauts returning from long‐duration missions, representing a significant risk to completing mission‐critical tasks. While likely multifactorial, a reduction in stroke volume (SV) represents one factor contributing to orthostatic intolerance during stand and head up tilt (HUT) tests. Current measures of SV during stand or HUT tests use Doppler ultrasound and require a trained operator and specialized equipment, restricting its use in the field. BeatScope (Finapres Medical Systems BV, The Netherlands) uses a modelflow algorithm to estimate SV from continuous blood pressure waveforms in supine subjects; however, evidence supporting the use of Modelflow to estimate SV in subjects completing stand or HUT tests remain scarce. Furthermore, because the blood pressure device is held extended at heart level during HUT tests, but allowed to rest at the side during stand tests, changes in the finger arterial pressure waveform resulting from arm positioning could alter modelflow estimated SV. The purpose of this project was to compare Doppler ultrasound and BeatScope estimations of SV to determine if BeatScope can be used during stand or HUT tests. Finger photoplethysmography was used to acquire arterial pressure waveforms corrected for hydrostatic finger‐to‐heart height using the Finometer (FM) and Portapres (PP) arterial pressure devices in 10 subjects (5 men and 5 women) during a stand test while simultaneous estimates of SV were collected using Doppler ultrasound. Measures were made after 5 minutes of supine rest and while subjects stood for 5 minutes. Next, SV estimates were reacquired while each arm was independently raised to heart level, a position similar to tilt testing. Supine SV estimates were not significantly different between all three devices (FM: 68+/-20, PP: 71+/-21, US: 73+/-21 ml/beat). Upon standing, the change in SV estimated by FM (‐18+/-8 ml) was not different from PP (‐21+/-12), but both were significantly less than US (‐37+/-16 ml, p<.05). Raising finger BP devices to heart level caused no significant change in SV measured with any of the devices (FM: 1.5+/-19, PP: 1.7+/-26, US: 0.5+/-6), although variability was 3‐6x greater as assessed by both blood pressure devices compared to US. Retrospective analysis of blood pressure data to assess SV in 11 supine subjects revealed significantly different estimates between methods (FM: 95+/-17, US: 75+/-32, p<.05), but the change in SV resulting from HUT was similar between methods (FM: ‐37+/-9, US: ‐40+/-18 ml). However, the correlation coefficient determined from pairs of SV estimated by US and FM was weak (r2=0.03). These data suggest Modelflow cannot be used in lieu of Doppler ultrasound to estimate SV during stand or HUT tests. Further investigation should focus on identifying factors contributing to differences between these measurement techniques in order to make use of a simple method for assessing beat‐by‐beat changes in SV during postural changes, especially during field testing.

Ferguson, Connor R.↗

Forecasting Sensorimotor Adaptability from Baseline Inter-Trial Correlations

One of the greatest challenges surrounding adaptation to the spaceflight environment is the large variability in symptoms, and corresponding functional impairments, from one crewmember to the next. This renders preflight training and countermeasure development difficult, as a "one-size-fits-all" approach is inappropriate. Therefore, it would be highly advantageous to know ahead of time which crewmembers might have more difficulty adjusting to the novel g-levels inherent to spaceflight. Such knowledge could guide individually customized countermeasures, which would enable more efficient use of crew time, both preflight and inflight, and provide better outcomes. The primary goal of this project is to look for a baseline performance metric that can forecast sensorimotor adaptability without exposure to an adaptive stimulus. We propose a novel hypothesis that considers baseline inter-trial correlations, the trial-to-trial fluctuations in motor performance, as a predictor of individual sensorimotor adaptive capabilities. To-date, a strong relationship has been found between baseline inter-trial correlations and adaptability in two oculomotor systems. For this project, we will explore an analogous predictive mechanism in the locomotion system. METHODS: Baseline Inter-trial Correlations: Inter-trial correlations specify the relationships among repeated trials of a given task that transpire as a consequence of correcting for previous performance errors over multiple timescales. We can quantify the strength of inter-trial correlations by measuring the decay of the autocorrelation function (ACF), which describes how rapidly information from past trials is "forgotten." Processes whose ACFs decay more slowly exhibit longer-term inter-trial correlations (longer memory processes), while processes whose ACFs decay more rapidly exhibit shorterterm inter-trial correlations (shorter memory processes). Longer-term correlations reflect low-frequency activity, which is more easily measured in the frequency domain. Therefore, we use the power spectrum (PS), which is the Fourier transform of the ACF, to describe our inter-trial correlations. The decay of the PS yields a straight line on a log-log frequency plot, which we quantify by Beta = - (slope of PS on log-log axes). Hence, Beta is a measure of the strength of inter- trial correlations in the baseline data. Larger Beta values are indicative of longer inter-trial correlations. Experimental Approach: We will begin by performing a retrospective analysis of treadmill-gait adaptation data previously collected by Dr. Bloomberg and colleagues. Specifically, we will quantify the strength of inter-trial correlations in the baseline step cadence and heart rate data and compare it to the locomotor adaptability performance results already described by these investigators. Incorporating these datasets will also allow us to explore the applicability of (and potential limitations surrounding) the use of Beta in forecasting physiological performance. We will also perform a new experiment, in which Beta will be derived from baseline data collected during over-ground (non-treadmill) walking, which will enable us to consider locomotor performance, through the parameter Beta, under the most functionallyrelevant, natural gait condition. This experiment will incorporate two baseline and five post-training over-ground locomotion tests to explore the consistency and potential adaptability of the Beta values themselves. HYPOTHESES: We hypothesize that the strength of baseline inter-trial correlations of step cadence and heart rate will relate to locomotor adaptability. Specifically, we anticipate that individuals who show weaker longer-term inter-trial correlations in baseline step cadence data will be the better adaptors, as step cadence can be modified in real-time (i.e., online corrections are an inherent property of the locomotor system; analogous to results observed in the VOR). Conversely, because heart rate is not altered mid-beat, we expect that individuals who demonstrate stronger longer-term correlations in heart rate will be the better adaptors (analogous to results observed in the saccadic system). CONCLUSIONS: At the conclusion of this project we hope to uncover a baseline predictor of locomotor adaptability. If our hypotheses hold true, our results will demonstrate that the temporal structure of baseline behavioral data contains important information that may aid in forecasting adaptive capacities. The ability to predict such adaptability in the sensorimotor system has significant implications for spaceflight, where astronauts must adjust their motor programs following a change in g-level to retain movement accuracy.

Beaton, K. H.↗

Evaluation of Different MODIS AOD Retrieval Algorithms for PM (sub 2.5) Estimation in the Western, Midwestern and Southeastern United States with Implications for Public Health

This study was part of the research activities of the Center for Applied Atmospheric Research and Education (CAARE) funded by the NASA MUREP (Minority University Research and Education Project) Institutional Research Opportunity (MIRO) Program. Satellite measurements of Aerosol Optical Depth (AOD) have been shown to be correlated with ground measurements of fine particulate matter less than 2.5 microns PM (sub 2.5), which in turn has been linked to respiratory and heart diseases. The strength of the correlation between AOD and PM (sub 2.5) varies for different AOD retrieval algorithms and geographic regions. We evaluated several Moderate Resolution Imaging Spectrometer (MODIS) AOD products from different satellites (Aqua vs. Terra), retrieval algorithms (Dark Target versus Deep Blue), Collections (5.1 versus 6) and spatial resolutions (10-kilometers versus 3-kilometers) for cities in the Western, Midwestern and Southeastern U.S. We developed and validated PM (sub 2.5) prediction models using remotely-sensed AOD data, which were improved by incorporating meteorological variables (temperature, relative humidity, precipitation, wind speed, and wind direction) from the North American Land Data Assimilation System Phase 2 (NLDAS-2). Adding these meteorological data significantly improved the predictive power of all the PM (sub 2.5) models, especially in the Western U.S. Temperature, relative humidity and wind speed were the most significant meteorological variables throughout the year in the Western U.S. Wind speed was the most significant meteorological variable for the cold season while temperature was the most significant variable for the warm season in the Midwestern and Southeastern U.S. Our study re-establishes the connection between PM (sub 2.5) and public health concerns including respiratory and cardiovascular diseases (asthma, high blood pressure, coronary heart disease, heart attack, and stroke). Using PM (sub 2.5) data and health data from the Centers for Disease Control and Prevention (CDC)'s Behavioral Risk Factor Surveillance System (BRFSS), our statistical analysis showed that heart attack and stroke occurrences had the strongest correlations with PM (sub 2.5).

Environmental Public Health↗

Deviations from uniform power law scaling in nonstationary time series

A classic problem in physics is the analysis of highly nonstationary time series that typically exhibit long-range correlations. Here we test the hypothesis that the scaling properties of the dynamics of healthy physiological systems are more stable than those of pathological systems by studying beat-to-beat fluctuations in the human heart rate. We develop techniques based on the Fano factor and Allan factor functions, as well as on detrended fluctuation analysis, for quantifying deviations from uniform power-law scaling in nonstationary time series. By analyzing extremely long data sets of up to N = 10(5) beats for 11 healthy subjects, we find that the fluctuations in the heart rate scale approximately uniformly over several temporal orders of magnitude. By contrast, we find that in data sets of comparable length for 14 subjects with heart disease, the fluctuations grow erratically, indicating a loss of scaling stability.

Non-NASA Center↗

Construction of extracellular matrix-based 3D hydrogel and its effects on cardiomyocytes

Highlights: • SOD and Triton X-100 could efficiently decellularize cells to get cardiac ECM. • Main proteins of cECM were fibronectin, collagen, elastin, fibrillin, laminin, etc. • 75% cECM-containing 3D hydrogel promoted cell proliferation and anti-apoptosis. • cECM3DH facilitated the differentiation of ESCs into CMs. • APcECM3DH was more conducive to NCM and ESC-derived CM maturation. Some discoveries resulted from 2-dimensional (2D) cultured cardiac cells have been disqualified in animal testing and later clinical trials. Extracellular matrix (ECM) plays a vital role in cardiac homeostasis, cardiac ECM (cECM)-based 3D cell cultures can mimics the physiological and pathological conditions in vivo closely, it is hopeful of addressing this challenge. Construction of cECM-based 3-dimensional (3D) hydrogel (cECM3DH) and its effects on cell behaviors were studied here. The results indicated that cellular compartments could be efficiently removed from heart tissue via sodium dodecyl sulfonate (SDS)- and Triton X-100-mediated decellularization, remaining the natural fibrous network structure and major proteins. 3D hydrogel consisted of 1 × 10{sup 7} cells/mL cells and 75% cECM could promote the proliferation and anti-apoptosis ability of human embryonic kidney (HEK)-293T cells. 0.25% trypsin or 0.20% collagenase was suitable to retrieve these cells from 3D hydrogel for further researches. Compared with 2D culture system, cECM3DH could significantly increase the proportion of GATA 4{sup +} cardiomyocytes (CMs) derived from heart tissue of neonatal mouse or induced differentiation of embryonic stem cells (ESCs) (P < 0.05) The expression levels of mature genes including cTnT, JCN, CaV1.2, MYL2, CASQ2, NCX1, and Cx43 of these CMs in adult pig cECM-based 3D hydrogel (APcECM3DH) were significantly higher than that in 2D culture system and in newborn piglet cECM-based 3D hydrogel (NPcECM3DH), respectively (P < 0.05). Therefore, cECM3DH supports the generation of primary CMs and ESC-derived CMs, APcECM3DH was more conducive to promoting CM maturation, which contributes to building 3D model for pathogenesis exploration, drug screening, and regenerative medicine of heart diseases.

60 APPLIED LIFE SCIENCES↗

Acute total body ionizing gamma radiation induces long-term adverse effects and immediate changes in cardiac protein oxidative carbonylation in the rat

Radiation-induced heart disease presents a significant challenge in the event of an accidental radiation exposure as well as to cancer patients who receive acute doses of irradiation as part of radiation therapy. We utilized the spontaneously hypertensive Wistar-Kyoto rat model, previously shown to demonstrate drug-induced cardiomyopathy, to evaluate the acute and long-term effects of sub-lethal total body gamma irradiation at two, four, and fiftytwo weeks. We further examined irreversible oxidative protein carbonylation in the heart immediately following irradiation in the normotensive Wistar-Kyoto rat. Both males and females sustained weight loss and anemic conditions compared to untreated controls over a one-year period as reflected by reduced body weight and low red blood cell count. Increased inflammation was detected by elevated IL-6 serum levels selectively in males at four weeks. Serum cardiac troponin T and I analyses revealed signs of cardiomyopathy at earlier timepoints, but high variability was observed, especially at one year. Echocardiography at two weeks following 5.0Gy treatment revealed a significant decrease in cardiac output in females and a significant decrease in both diastolic and systolic volumes in males. Following 10.0Gy irradiation in the normotensive Wistar-Kyoto rat, the heart tissue showed an increase in total protein oxidative carbonylation accompanied by DNA damage indicated by an increase in γ-H2AX. Using proteomic analyses, we identified several novel proteins which showed a marked difference in carbonylation including those of mitochondrial origin and most notably, cardiac troponin T, one of the key proteins involved in cardiomyocyte contractility. Overall, we present findings of acute oxidative protein damage, DNA damage, cardiac troponin T carbonylation, and long-term cardiomyopathy in the irradiated animals.

59 BASIC BIOLOGICAL SCIENCES↗

Model-based parameter estimation using cardiovascular response to orthostatic stress

This paper presents a cardiovascular model that is capable of simulating the short-term (< or approximately equal to 3 min) transient hemodynamic response to gravitational stress and a gradient-based optimization method that allows for the automated estimation of model parameters from simulated or experimental data. We perform a sensitivity analysis of the transient heart rate response to determine which parameters of the model impact the heart rate dynamics significantly. We subsequently include only those parameters in the estimation routine that impact the transient heart rate dynamics substantially. We apply the estimation algorithm to both simulated and real data and showed that restriction to the 20 most important parameters does not impair our ability to match the data.

Non-NASA Center↗

NOS II inhibition attenuates post-suspension hypotension in Sprague-Dawley rats

The reduction in mean arterial pressure observed in astronauts may be related to the impairment of autonomic function and/or excessive production of endothelium-derived relaxing factors. Here, we examined the role of a nitric oxide synthase II (NOS II) inhibitor AMT (2-amino-dihydro-6-methyl-4H-1,3-thiazine) against the post-suspension reduction in mean arterial pressure (MAP) in conscious male Sprague-Dawley rats. Direct MAP and heart rate were determined prior to tail-suspension, daily during the 7-day suspension and every 2 hrs post-suspension. Prior to release from suspension and at 2 and 4 hrs post-suspension, AMT (0.1 mg/kg), or saline, were administered intravenously. During the 7-day suspension, MAP was not altered, nor were there significant changes in heart rate. The reduction in MAP post-suspension in saline-treated rats was associated with significant increases in plasma nitric oxide and prostacyclin. 2-Amino-dihydro-6-methyl4H-1,3-thiazine reduced plasma nitric oxide levels, but not those of prostacyclin, attenuated the observed post-suspension reduction in MAP and modified the baroreflex sensitivity for heart rate. Thus, the post suspension reduction in mean arterial pressure is due, in part, to overproduction of nitric oxide, via the NOS II pathway, and alteration in baroreflex activity.

NASA Discipline Cardiopulmonary↗

Indomethacin attenuates post-suspension hypotension in Sprague-Dawley rats

Orthostatic hypotension is a serious condition that is sometimes manifested in astronauts during standing postflight. These observations may be related to impairment of autonomic function and/or excessive production of endothelium-dependent relaxing factors. To evaluate the role of the cyclooxygenase inhibitor indomethacin as a countermeasure against the post-suspension reduction in mean arterial pressure (MAP), we examined the cardiovascular responses to 7-day 30 degrees tail-suspension and a subsequent 6-hr post-suspension period in conscious male Sprague-Dawley rats. Indomethacin (2 mg/kg) or saline were administered intravenously prior to release from suspension and at 2 and 4 hrs post-suspension. Direct MAP and heart rate were determined prior to suspension, daily and every 2 hrs post-suspension. During suspension, MAP did not change, in contrast, during post-suspension; it decreased compared to parallel non-suspended, untreated animals. There were no significant changes in heart rate. The reduction in MAP post-suspension was associated with significant increases in plasma prostacyclin. Indomethacin attenuated the observed post-suspension reduction in MAP and reduced plasma prostacyclin levels. Also, the baroreflex sensitivity for heart rate was modified by indomethacin--the MAP threshold for baroreflex activation was raised and the effective MAP range expanded. Thus, the post suspension reduction in mean arterial pressure may be due to overproduction of vasodilatory prostaglandins and/or other endothelium-dependent relaxing factors and alteration in baroreflex activity.

NASA Discipline Cardiopulmonary↗

T wave alternans threshold late after repair of tetralogy of Fallot

INTRODUCTION: Sustained microvolt-level T wave alternans (TWA) is a marker of increased risk for malignant ventricular arrhythmia. There is a significant risk of arrhythmia and sudden death after repair of congenital heart disease. The aim of this study was to determine the prevalence and characteristics of TWA after repair of tetralogy of Fallot (TOF). METHODS AND RESULTS: TWA was evaluated during bicycle exercise in 49 subjects who had consecutively undergone transatrial-transpulmonary repair. Median values for age, age at repair, and follow-up duration were 14.9 years (11.5-20.8), 1.6 years (0.2-4.9), and 11.6 years (9.4-17.2), respectively. All patients were in New York Heart Association functional class I and were asymptomatic. Median QRS duration was 120 msec (80-150). Sustained TWA was detected in 7 (23%) of 31 subjects with adequate tests. In these 7 subjects, median onset heart rate (HR) was 120 (98-155). Median HR threshold as a percentage of predicted maximum HR (220 - age) was 58% (48-77). Sustained TWA prevalence was not significantly different compared with normal subjects (7/31 vs 9/83; P = 0.1). Onset HR in the TOF group was significantly lower [mean (SD) of 122 (20) vs 139 (12), P < 0.05]. In the TOF group with sustained TWA, the TWA occurred in 4 of 7 at <60% predicted maximum HR versus 1 of 9 normal subjects (P < 0.05); 3 of 7 had onset HR <120 versus 0 of 9 normal subjects (P < 0.03). There was no significant difference in age, gender, transannular patch use, restrictive right ventricular physiology, QRS duration, QTc, QT/QRS dispersion, or nonsustained ventricular tachycardia in subjects with or those without sustained TWA. CONCLUSION: The onset HR for sustained TWA is significantly lower after repair of TOF. Further study is required to determine whether this represents an increased risk for arrhythmia in this patient group.

Non-NASA Center↗

Human muscle sympathetic nerve activity and plasma noradrenaline kinetics in space

Astronauts returning from space have reduced red blood cell masses, hypovolaemia and orthostatic intolerance, marked by greater cardio-acceleration during standing than before spaceflight, and in some, orthostatic hypotension and presyncope. Adaptation of the sympathetic nervous system occurring during spaceflight may be responsible for these postflight alterations. We tested the hypotheses that exposure to microgravity reduces sympathetic neural outflow and impairs sympathetic neural responses to orthostatic stress. We measured heart rate, photoplethysmographic finger arterial pressure, peroneal nerve muscle sympathetic activity and plasma noradrenaline spillover and clearance, in male astronauts before, during (flight day 12 or 13) and after the 16 day Neurolab space shuttle mission. Measurements were made during supine rest and orthostatic stress, as simulated on Earth and in space by 7 min periods of 15 and 30 mmHg lower body suction. Mean (+/- S.E.M.) heart rates before lower body suction were similar pre-flight and in flight. Heart rate responses to -30 mmHg were greater in flight (from 56 +/- 4 to 72 +/- 4 beats min(-1)) than pre-flight (from 56 +/- 4 at rest to 62 +/- 4 beats min(-1), P < 0.05). Noradrenaline spillover and clearance were increased from pre-flight levels during baseline periods and during lower body suction, both in flight (n = 3) and on post-flight days 1 or 2 (n = 5, P < 0.05). In-flight baseline sympathetic nerve activity was increased above pre-flight levels (by 10-33 %) in the same three subjects in whom noradrenaline spillover and clearance were increased. The sympathetic response to 30 mmHg lower body suction was at pre-flight levels or higher in each subject (35 pre-flight vs. 40 bursts min(-1) in flight). No astronaut experienced presyncope during lower body suction in space (or during upright tilt following the Neurolab mission). We conclude that in space, baseline sympathetic neural outflow is increased moderately and sympathetic responses to lower body suction are exaggerated. Therefore, notwithstanding hypovolaemia, astronauts respond normally to simulated orthostatic stress and are able to maintain their arterial pressures at normal levels.

STS-90 Shuttle Project↗

Baroreflex modulation of sympathetic nerve activity to muscle in heat-stressed humans

To identify whether whole body heating alters arterial baroreflex control of muscle sympathetic nerve activity (MSNA), MSNA and beat-by-beat arterial blood pressure were recorded in seven healthy subjects during acute hypotensive and hypertensive stimuli in both normothermic and heat stress conditions. Whole body heating significantly increased sublingual temperature (P < 0.01), MSNA (P < 0.01), heart rate (P < 0.01), and skin blood flow (P < 0.001), whereas mean arterial blood pressure did not change significantly (P > 0.05). During both normothermic and heat stress conditions, MSNA increased and then decreased significantly when blood pressure was lowered and then raised via intravenous bolus infusions of sodium nitroprusside and phenylephrine HCl, respectively. The slope of the relationship between MSNA and diastolic blood pressure during heat stress (-128.3 +/- 13.9 U x beats(-1) x mmHg(-1)) was similar (P = 0.31) with normothermia (-140.6 +/- 21.1 U x beats(-1) x mmHg(-1)). Moreover, no significant change in the slope of the relationship between heart rate and systolic blood pressure was observed. These data suggest that arterial baroreflex modulation of MSNA and heart rate are not altered by whole body heating, with the exception of an upward shift of these baroreflex curves to accommodate changes in these variables that occur with whole body heating.

NASA Discipline Cardiopulmonary↗

Sequential modulation of cardiac autonomic control induced by cardiopulmonary and arterial baroreflex mechanisms

BACKGROUND: Nonhypotensive lower body negative pressure (LBNP) induces a reflex increase in forearm vascular resistance and muscle sympathetic neural discharge without affecting mean heart rate. We tested the hypothesis that a reflex change of the autonomic modulation of heartbeat might arise during low intensity LBNP without changes of mean heart rate. METHODS AND RESULTS: Ten healthy volunteers underwent plasma catecholamine evaluation and a continuous recording of ECG, finger blood pressure, respiratory activity, and central venous pressure (CVP) during increasing levels of LBNP up to -40 mm Hg. Spectrum and cross-spectrum analyses assessed the changes in the spontaneous variability of R-R interval, respiration, systolic arterial pressure (SAP), and CVP and in the gain (alpha(LF)) of arterial baroreflex control of heart rate. Baroreceptor sensitivity was also evaluated by the SAP/R-R spontaneous sequences technique. LBNP began decreasing significantly: CVP at -10, R-R interval at -20, SAP at -40, and the indexes alpha(LF) and baroreceptor sensitivity at -30 and -20 mm Hg, compared with baseline conditions. Plasma norepinephrine increased significantly at -20 mm Hg. The normalized low-frequency component of R-R variability (LF(R-R)) progressively increased and was significantly higher than in the control condition at -15 mm Hg. CONCLUSIONS: Nonhypotensive LBNP elicits a reflex increase of cardiac sympathetic modulation, as evaluated by LF(R-R), which precedes the changes in the hemodynamics and in the indexes of arterial baroreflex control.

Non-NASA Center↗