Search NASA⌕ Search

SEARCH · Search NASA

Results for “HOLLOW CATHODES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Plasma electron source for the generation of wide-aperture pulsed beam at forevacuum pressures

This article reports on design and application of wide-aperture pulsed beam source, based on hollow cathode discharge. The source is intended for electron beam generation in pressure range 2-15 Pa. Multi-aperture extraction system, used in a source, provided beam cross-section uniformity of 10% on diameter 40 mm. The limiting values of the current density, pulse duration, and accelerating voltage are 350 mA/cm{sup 2}, 250 {mu}s, and 10 kV, respectively. These parameters are sufficient for surface modification of various materials, including non-conducting matters.

43 PARTICLE ACCELERATORS↗

Fabrication of AlN/BN bishell hollow nanofibers by electrospinning and atomic layer deposition

Aluminum nitride (AlN)/boron nitride (BN) bishell hollow nanofibers (HNFs) have been fabricated by successive atomic layer deposition (ALD) of AlN and sequential chemical vapor deposition (CVD) of BN on electrospun polymeric nanofibrous template. A four-step fabrication process was utilized: (i) fabrication of polymeric (nylon 6,6) nanofibers via electrospinning, (ii) hollow cathode plasma-assisted ALD of AlN at 100 °C onto electrospun polymeric nanofibers, (iii) calcination at 500 °C for 2 h in order to remove the polymeric template, and (iv) sequential CVD growth of BN at 450 °C. AlN/BN HNFs have been characterized for their chemical composition, surface morphology, crystal structure, and internal nanostructure using X-ray photoelectron spectroscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive X-ray spectroscopy, and selected area electron diffraction. Measurements confirmed the presence of crystalline hexagonal BN and AlN within the three dimensional (3D) network of bishell HNFs with relatively low impurity content. In contrast to the smooth surface of the inner AlN layer, outer BN coating showed a highly rough 3D morphology in the form of BN nano-needle crystallites. It is shown that the combination of electrospinning and plasma-assisted low-temperature ALD/CVD can produce highly controlled multi-layered bishell nitride ceramic hollow nanostructures. While electrospinning enables easy fabrication of nanofibrous template, self-limiting reactions of plasma-assisted ALD and sequential CVD provide control over the wall thicknesses of AlN and BN layers with sub-nanometer accuracy.

36 MATERIALS SCIENCE↗

Fast plasma discharge capillary design as a high power throughput soft x-ray emission source

We present the experimental details and results from a low energy but high repetition rate compact plasma capillary source for extreme ultraviolet and soft x-ray research and applications. Two lengths of capillary are mounted in two versions of a closely related design. The discharge operates in 1.6 and 3.2 mm inner diameter alumina capillaries of lengths 21 and 36 mm. The use of water both as dielectric and as coolant simplifies the compact low inductance design with nanosecond discharge periods. The stored electrical energy of the discharge is approximately 0.5 J and is provided by directly charging the capacitor plates from an inexpensive insulated-gate bipolar transistor in 1 {mu}s or less. We present characteristic argon spectra from plasma between 30 and 300 A as well as temporally resolved x-ray energy fluence in discrete bands on axis. The spectra also allow the level of ablated wall material to be gauged and associated with useful capillary lifetime according to the chosen configuration and energy storage. The connection between the electron beams associated with the transient hollow cathode mechanism, soft x-ray output, capillary geometry, and capillary lifetime is reported. The role of these e-beams and the plasma as measured on-axis is discussed. The relation of the electron temperature and the ionization stages observed is discussed in the context of some model results of ionization in a non-Maxwellian plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of nonlinear oscillations in a glow discharge plasma using empirical mode decomposition and Hilbert Huang transform

Hilbert Huang transform (HHT) based time series analysis was carried out on nonlinear floating potential fluctuations obtained from hollow cathode glow discharge plasma in the presence of anode glow. HHT was used to obtain contour plots and the presence of nonlinearity was studied. Frequency shift with time, which is a typical nonlinear behaviour, was detected from the contour plots. Various plasma parameters were measured and the concepts of correlation coefficients and the physical contribution of each intrinsic mode function have been discussed. Physically important quantities such as instantaneous energy and their uses in studying physical phenomena such as intermittency and non-stationary data have also been discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rotational excitation of hydrogen molecules in low temperature plasmas

The excitation mechanism of the H{sub 2} rotational temperature has been studied in a hollow-cathode glow discharge apparatus based on the measurements of relation between the rotational and cathode surface temperature. The rotational temperature evaluated by an excitation-emission model for the Fulcher-{alpha} transition indicates clear correlation with the surface temperature. Depending on the plasma parameters and neutral gas pressures, slight difference between both the temperatures is also observed. The temporal evolution of the rotational population densities predicted by rate equations suggests that the difference is attributable to an inequilibrium between the translational and surface temperature. Further possibility of an inequilibrium among the rotational, translational, and surface temperature is expected in low pressure or high electron density conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anodization of aluminum and silicon in plasma of a non-self-sustained glow discharge

The results of anodization of aluminum and silicon in an oxygen plasma are presented. The plasma was generated by a non-self-sustained glow discharge with a hollow cathode excited by an electron beam at the oxygen pressure of 20 Pa. The density of the current flowing through the anodized specimen did not exceed 1.5 mA/cm{sup 2}, and its temperature was 200-250 Degree-Sign C. Continuous Al{sub 2}O{sub 3} and SiO{sub 2} films were formed on the aluminum and silicon surfaces. The growth rate of the oxide layers was 150-200 nm/h for Al{sub 2}O{sub 3} and 400-800 nm/h for SiO{sub 2}.

36 MATERIALS SCIENCE↗

Early results of microwave transmission experiments through an overly dense rectangular plasma sheet with microparticle injection

These experiments utilize a linear hollow cathode to create a dense, rectangular plasma sheet to simulate the plasma layer surrounding vehicles traveling at hypersonic velocities within the Earth's atmosphere. Injection of fine dielectric microparticles significantly reduces the electron density and therefore lowers the electron plasma frequency by binding a significant portion of the bulk free electrons to the relatively massive microparticles. Measurements show that microwave transmission through this previously overly dense, impenetrable plasma layer increases with the injection of alumina microparticles approximately 60 μm in diameter. This method of electron depletion is a potential means of mitigating the radio communications blackout experienced by hypersonic vehicles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sustenance of inhomogeneous electron temperature in a magnetized plasma column

This paper presents the equilibrium properties of a magnetized plasma column sustained by direct-current (dc) operated hollow cathode discharge in conjunction with a conducting end-plate, acting as the anode. The survey of radial plasma characteristics, performed in argon plasma, shows hotter plasma in the periphery as compared to the central plasma region; whereas the plasma density peaks at the center. The off-centered peak in radial temperature is attributed due to inhomogeneous power deposition in the discharge volume in conjunction with short-circuiting effect by the conducting end plate. A theoretical model based on particle flux and energy balance is given to explain the observed characteristics of the plasma column.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ferm cathode operation in the test bed ion engine

A rapid start hollow cathode has been developed for high power ion thruster application. Using no low work function insert or heater, the Field Enhanced Refractory Metal (FERM) cathode electron emission occurs from a refractory metal tube concentric with the cathode barrel. Results are presented for FERM cathode operation in the high field strength Test Bed Ion Engine. Using a controlled glow discharge heating technique, cathode start up times of 1-2 secs are shown. Cathode V-I curves up to 35 ampere emission are presented and life limiting component erosion mechanisms, at these high current levels, are discussed.

Aston, G.↗

THE MAGNESIUM ISOTOPOLOGUES OF MgH IN THE A {sup 2}{Pi}-X {sup 2}{Sigma}{sup +} SYSTEM

Using laboratory hollow cathode spectra we have identified lines of the less common magnesium isotopologues of MgH, {sup 25}MgH and {sup 26}MgH, in the A {sup 2}{Pi}-X {sup 2}{Sigma}{sup +} system. Based on the previous analysis of {sup 24}MgH, molecular lines have been measured and molecular constants derived for {sup 25}MgH and {sup 26}MgH. Term values and linelists, in both wavenumber and wavelength units, are presented. The A {sup 2}{Pi}-X {sup 2}{Sigma}{sup +} system of MgH is important for measuring the magnesium isotope ratios in stars. Examples of analysis using the new linelists to derive the Mg isotope ratio in a metal poor dwarf and giant are shown.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SPECTRUM OF Fe II

The spectrum of singly ionized iron (Fe II) has been recorded using high-resolution Fourier transform (FT) and grating spectroscopy over the wavelength range 900 A to 5.5 {mu}m. The spectra were observed in high-current continuous and pulsed hollow cathode discharges using FT spectrometers at the Kitt Peak National Observatory, Tucson, AZ and Imperial College, London and with the 10.7 m Normal Incidence Spectrograph at the National Institute of Standards and Technology. Roughly 12,900 lines were classified using 1027 energy levels of Fe II that were optimized to measured wavenumbers. The wavenumber uncertainties of lines in the FT spectra range from 10{sup -4} cm{sup -1} for strong lines around 4 {mu}m to 0.05 cm{sup -1} for weaker lines around 1500 A. The wavelength uncertainty of lines in the grating spectra is 0.005 A. The ionization energy of (130,655.4 {+-} 0.4) cm{sup -1} was estimated from the 3d{sup 6}({sup 5}D)5g and 3d{sup 6}({sup 5}D)6h levels.

74 ATOMIC AND MOLECULAR PHYSICS↗

Generation of a pulsed low-energy electron beam using the channel spark device

For the generation of low-energy electron beam, the design and characteristics of channel spark discharge (CSD) operating at a low voltage are presented in this paper. The discharge voltage, discharge current, X-ray emissions, and electron beam current were experimentally determined. The effects of the applied voltage, working gas pressure, and external capacitance on the CSD and beam parameters were measured. At an applied voltage of 11 kV, an oxygen gas pressure of 25 mTorr, and an external capacitance of 16.45 nF, the maximum measured current was 900 A. The discharge current increased with the increase in the pressure and capacitance, while its periodic time decreased with the increase in the pressure. Two types of the discharge were identified and recorded: the hollow cathode discharge and the conduction discharge. A Faraday cup was used to measure the beam current. The maximum measured beam current was 120 A, and the beam signal exhibited two peaks. The increase in both the external capacitance and the applied discharge voltage increased the maximum electron beam current. The electron-beam pulse time decreased with the increase in the gas pressure at a constant voltage and increased with the decrease in the applied discharge voltage. At an applied voltage of 11 kV and an oxygen gas pressure of 15 mTorr, the maximum beam energy was 2.8 keV. The X-ray signal intensity decreased with the increase in the gas pressure and increased with the increase in the capacitance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broad-beam high-current dc ion source based on a two-stage glow discharge plasma

We have designed, made, and demonstrated a broad-beam, dc, ion source based on a two-stage, hollow-cathode, and glow discharges plasma. The first-stage discharge (auxiliary discharge) produces electrons that are injected into the cathode cavity of a second-stage discharge (main discharge). The electron injection causes a decrease in the required operating pressure of the main discharge down to 0.05 mTorr and a decrease in required operating voltage down to about 50 V. The decrease in operating voltage of the main discharge leads to a decrease in the fraction of impurity ions in the ion beam extracted from the main gas discharge plasma to less than 0.2 %. Another feature of the source is a single-grid accelerating system in which the ion accelerating voltage is applied between the plasma itself and the grid electrode. The source has produced steady-state Ar, O, and N ion beams of about 14 cm diameter and current of more than 2 A at an accelerating voltage of up to 2 kV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion trajectories in plasma ion implantation of slender cylindrical bores using a small inner end source

Plasma immersion ion implantation (PIII) into slender cylindrical bores with higher efficiency is described in this letter. The use of an inner end plasma source excited by a radio-frequency hollow cathode is investigated theoretically and experimentally. The end source that is covered by a small grounded shielding electrode to ensure steady discharge enables continuous delivery of the required plasmas, and the potential difference in the tube increases the ion impact energy. Particle-in-cell simulation demonstrates that the ion trajectories are complex due to the special electric field configuration that is composed of three regions characterized by ion acceleration, no electric field, and ion deceleration. The end source structure with the open shielding electrode is insufficient to achieve high ion energy, although it is effective in maintaining a steady discharge in the source. Hence, a shielding electrode with a protruding electrode structure is required to conduct high energy PIII; a cylindrical bore with an inner diameter of 20 mm is successfully implanted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrostatic ion acceleration across a diverging magnetic field

Electrostatic ion acceleration across a diverging magnetic field, which is generated by a solenoid coil, permanent magnets, and a yoke between an upstream ring anode and a downstream off-axis hollow cathode, is investigated. The cathode is set in an almost magnetic-field-free region surrounded by a cusp. Inside the ring anode, an insulating wall is set to form an annular slit through which the working gas is injected along the anode inner surface, so the ionization of the working gas is enhanced there. By supplying 1.0 Aeq of argon as working gas with a discharge voltage of 225 V, the ion beam energy reached about 60% of a discharge voltage. In spite of this unique combination of electrodes and magnetic field, a large electrical potential drop is formed almost in the axial direction, located slightly upstream of the magnetic-field-free region. The ion beam current almost equals the equivalent working gas flow rate. These ion acceleration characteristics are useful for electric propulsion in space.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE SPECTRUM AND TERM ANALYSIS OF V II

The spectrum and extended term analysis of V II are presented. Fourier transform spectrometry was used to record high resolution spectra of singly ionized vanadium in the region 1492-5800 A (67020-17260 cm{sup -1}) with vanadium-neon and vanadium-argon hollow cathode lamps as sources. The wavenumber uncertainty for the center of gravity of the strongest lines is typically 0.002 cm{sup -1}, an improvement of an order of magnitude over previous measurements. Most of the lines exhibit partly resolved hyperfine structure. The V II energy levels in the 1985 compilation of Sugar and Corliss have been confirmed and revised, with the exception of the high-lying 4f levels and eight of the lower levels. Thirty-nine of the additional eighty-five high levels published by Iglesias et al. have also been confirmed and revised, and three of their missing levels have been found. The energy uncertainty of the revised levels has been reduced by about an order of magnitude. In total, 176 even levels and 233 odd levels are presented. Wavenumbers and classifications are given for 1242 V II lines.

74 ATOMIC AND MOLECULAR PHYSICS↗

IMPROVED V I log(gf) VALUES AND ABUNDANCE DETERMINATIONS IN THE PHOTOSPHERES OF THE SUN AND METAL-POOR STAR HD 84937

New emission branching fraction measurements for 836 lines of the first spectrum of vanadium (V I) are determined from hollow cathode lamp spectra recorded with the National Solar Observatory 1 m Fourier transform spectrometer (FTS) and a high-resolution echelle spectrometer. The branching fractions are combined with recently published radiative lifetimes from laser-induced fluorescence measurements to determine accurate absolute atomic transition probabilities for the 836 lines. The FTS data are also used to extract new hyperfine structure A coefficients for 26 levels of neutral vanadium. These new laboratory data are applied to determine the V abundance in the Sun and metal-poor star HD 84937, yielding log ε(V) = 3.956 ± 0.004 (σ = 0.037) based on 93 V I lines and log ε(V) = 1.89 ± 0.03 (σ = 0.07) based on nine V I lines, respectively, using the Holweger-Müller 1D model. These new V I abundance values for the Sun and HD 84937 agree well with our earlier determinations based upon V II.

79 ASTRONOMY AND ASTROPHYSICS↗

Line Identification of Atomic and Ionic Spectra of Holmium in the Near-UV. Part I. Spectrum of Ho i

The Fourier Transform spectra of a Holmium hollow cathode discharge lamp have been investigated in the UV spectral range from 25,000 up to 31,530 cm{sup −1} (317 to 400 nm). Two Ho spectra have been measured with neon and argon as buffer gases. Based on the intensity ratios from these two spectra, a distinction was made between atomic and ionic lines (ionic lines are discussed in an accompanying paper). Using the known Ho i energy levels, 71 lines could be classified as transitions of atomic Ho, 34 of which have not been published previously. Another 32 lines, which could not be classified, are listed in the literature and assigned as atomic Ho. An additional 370 spectral lines have been assigned to atomic Ho based on the signal-to-noise ratio in the two spectra measured under different discharge conditions, namely with buffer gases argon and neon, respectively. These 370 lines have not been previously listed in the literature.

74 ATOMIC AND MOLECULAR PHYSICS↗