Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

High Performance EVA Glove Collaboration: Glove Injury Data Mining Effort

Human hands play a significant role during Extravehicular Activity (EVA) missions and Neutral Buoyancy Lab (NBL) training events, as they are needed for translating and performing tasks in the weightless environment. Because of this high frequency usage, hand and arm related injuries are known to occur during EVA and EVA training in the NBL. The primary objectives of this investigation were to: 1) document all known EVA glove related injuries and circumstances of these incidents, 2) determine likely risk factors, and 3) recommend interventions where possible that could be implemented in the current and future glove designs. METHODS: The investigation focused on the discomforts and injuries of U.S. crewmembers who had worn the pressurized Extravehicular Mobility Unit (EMU) spacesuit and experienced 4000 Series or Phase VI glove related incidents during 1981 to 2010 for either EVA ground training or in-orbit flight. We conducted an observational retrospective case-control investigation using 1) a literature review of known injuries, 2) data mining of crew injury, glove sizing, and hand anthropometry databases, 3) descriptive statistical analyses, and finally 4) statistical risk correlation and predictor analyses to better understand injury prevalence and potential causation. Specific predictor statistical analyses included use of principal component analyses (PCA), multiple logistic regression, and survival analyses (Cox proportional hazards regression). Results of these analyses were computed risk variables in the forms of odds ratios (likelihood of an injury occurring given the magnitude of a risk variable) and hazard ratios (likelihood of time to injury occurrence). Due to the exploratory nature of this investigation, we selected predictor variables significant at p≤0.15. RESULTS: Through 2010, there have been a total of 330 NASA crewmembers, from which 96 crewmembers performed 322 EVAs during 1981-2010, resulting in 50 crewmembers being injured inflight and 44 injured during 11,704 ground EVA training events. Of the 196 glove related injury incidents, 106 related to EVA and 90 to EVA training. Over these 196 incidents, 277 total injuries (126 flight; 151 training) were reported and were then grouped into 23 types of injuries. Of EVA flight injuries, 65% were commonly reported to the hand (in general), metacarpophalangeal (MCP) joint, and finger (not including thumb) with fatigue, abrasion, and paresthesia being the most common injury types (44% of total flight injuries). Training injuries totaled to more than 70% being distributed to the fingernail, MCP joint, and finger crotch with 88% of the specific injuries listed as pain, erythema, and onycholysis. Of these training injuries, when reporting pain or erythema, the most common location was the index finger, but when reporting onycholysis, it was the middle finger. Predictor variables specific to increased risk of onycholysis included: female sex (OR=2.622), older age (OR=1.065), increased duration in hours of the flight or training event (OR=1.570), middle finger length differences in inches between the finger and the EVA glove (OR=7.709), and use of the Phase VI glove (OR=8.535). Differentiation between training and flight and injury reporting during 2002-2004 were significant control variables. For likelihood of time to first onycholysis injury, there was a 24% reduction in rate of reporting for each year increase in age. Also, more experienced crewmembers, based on number of EVA flight or training events completed, were less likely to report an onycholysis injury (3% less for every event). Longer duration events also found reporting rates to occur 2.37 times faster for every hour of length. Crewmembers with larger hand size reported onycholysis 23% faster than those with smaller hand size. Finally, for every 1/10th of an inch increase in difference between the middle finger length and the glove, the rate of reporting increased by 60%. DISCUSSION: One key finding was that the Series 4000 glove had a lower injury risk than the Phase VI, which provides a platform for further evaluation. General interventions that reduce hand overexertion and repetitive use exposure through tool development, procedural changes and shorter exposures may be one mitigation path, but due to the way the training event times were reported, we cannot provide a guideline for a specific event duration change. When the finger length was different from the glove length, the risk of injury increased indicating that the use of larger finger take-ups could be contributing to injury and therefore may not be recommended. Prior to this investigation, there was one previous investigation indicating hand anthropometry may be related to onycholysis. We found different hand anthropometry variables indicated by this investigation as compared to the prior, specifically differences in middle finger length compared to glove finger length, which point more towards a sizing issue than a specific anthropometry issue. Additionally, although this investigation has identified sizing as an issue, the force and environmental-related variables of the EVA glove that could also cause injury were not accounted for.

Reid, C. R.↗

Spacesuit and Mobility Performance Changes

The complex interactions between the human body and spacesuit lead to changes inmovement patterns and mobility performancesof the wearer. In general, factors including the geometric properties, such as shape and size, mechanical properties of the suit, and pressurization of the suit are known to be associated with altered movement patterns as compared to an unsuited human.However, their relative contributions have not been explicitly quantified from the mobility performance perspectives. The goal of this study wasthus to assessthe effects fromthe different types of mobility constraintconditions, namely by wearing either a 3D printed hard upper torso (HUT) assembly orfully pressurized spacesuit. The outcome was also compared against the unsuited motions. For this study, an xEMU (exploration Extravehicular Mobility Unit) suitwas considered, which is the next generation spacesuit developed by NASA. In each test condition, the subject was asked to move the arm and hand as prescribedfor different task types, and the corresponding body segment locations were recordedusing a 3D motion capture system. The following three tasks were performedand analyzed: 1) Outward one-handed reaches:the subject in a standing pose made sweeping motions with the extended right arm from the extreme end-to-end positions, including side-to-side at different elevations and top-to-bottom at different azimuths. 2) Outward two-handed reaches:similarto the previous task, howeverthe subject kept the hands together during the motions in order to assessthe areas that can be reached by both hands. 3) Inward one-handed reaches:the subject made right-hand reach motions to the surface of the HUT.The hand traces collected from each task were modeled by a template shape parametrically deformed with a radial basis function. This process enabled foran abstraction of the hand traces into a smooth surface envelope representing the maximally reachable area of the test subject, of which the shapes and sizes were compared across the different test conditions. The preliminary analysis has shown that theoverall size of reachenvelopes decreases in a pressurized suit compared to 3D printed mockup HUT and unsuited conditions. The specific shape of the envelopes, which were determined by the reachable and unreachable zones, alsovary with the testconditions, and the differences werepronounced with the inward reaches to the HUT surface. The latter observation ispotentially relatedto the increased demandfor shoulder and elbow flexions.Overcomingthe resistance from the pressurizedsoft goods and mechanical constraints of the shoulder assemblywas seen to be associated with the difference in motion patterns between the suited and unsuited conditions. Overall, the information quantified from this study is expected to provide structured metrics for spacesuit mobility, which can improve design optimization and human-system integration.

K Han Kim↗

Hesitation in tracking induced by a concurrent manual task

When people are required to track with one hand and perform occasional discrete responses with the other hand, there is a strong possibility that errors will be induced in tracking attributable to the simultaneous action by the other. This problem was investigated by pairing pursuit tracking (right hand) with a handle movement response (left hand) guided by an auditory stimulus. Tracking is assumed to represent flight control and the left hand response to represent other aspects of aircraft system management. The general goal of this research is to identify the types of errors induced into tracking by the requirement of a secondary response with the other hand. An attempt is reported to determine if hesitations can be reduced further by combining tracking emphasis with a higher degree of practice. It is concluded that there is a tendency to freeze the tracking response when a discrete simultaneous response is required of the other hand. By contrast, practice seems to reduce hesitations while also improving left hand reaction time. Thus there appears to be a mode of control which permits tracking and discrete simultaneous responses to occur together.

Kelly, P. A.↗

Application of dexterous space robotics technology to myoelectric prostheses

Future space missions will require robots equipped with highly dexterous robotic hands to perform a variety of tasks. A major technical challenge in making this possible is an improvement in the way these dexterous robotic hands are remotely controlled or teleoperated. NASA is currently investigating the feasibility of using myoelectric signals to teleoperate a dexterous robotic hand. In theory, myoelectric control of robotic hands will require little or no mechanical parts and will greatly reduce the bulk and weight usually found in dexterous robotic hand control devices. An improvement in myoelectric control of multifinger hands will also benefit prosthetics users. Therefore, as an effort to transfer dexterous space robotics technology to prosthetics applications and to benefit from existing myoelectric technology, NASA is collaborating with the Limbs of Love Foundation, the Institute for Rehabilitation and Research, and Rice University in developing improved myoelectric control multifinger hands and prostheses. In this paper, we will address the objectives and approaches of this collaborative effort and discuss the technical issues associated with myoelectric control of multifinger hands. We will also report our current progress and discuss plans for future work.

Hess, Clifford↗

Anti-Phase Vortex Reduction Control for Rotor Noise Suppression

An investigation is conducted in 2019 under the NASA Ames Center Innovation Funds (CIF) project entitled “Anti-Phase Vortex Reduction Control for Rotor Noise Suppression“ to experimentally validate an anti-phase rotor noise suppression concept. The first objective of the investigation is to conduct computational fluid dynamics (CFD) simulations to investigate the noise characteristics of several anti-phase rotor designs. The second objective is to conduct a series of acoustic tests of anti-phase rotors in an anechoic chamber at Pennsylvania State University (PSU) to evaluate the merit of the anti-phase rotor concept. The CFD investigation seeks to optimize the anti-phase alternating trailing edge patterns for rotor noise suppression. The design objective is to maximize the noise reduction while maintaining the aerodynamic thrust. The investigation is performed using a three-dimensional (3D) Unsteady Reynolds-Averaged Navier-Stokes (URANS) commercial solver STAR-CCM+ together with the Ffowcs-Williams and Hawkings (FW-H) formula to obtain the aerodynamic thrust and far-field noise level. An acoustic study is conducted for 13 anti-phase design candidates based on a proprietary rotor design. The CAD geometry of the rotor is furnished by PSU. These design candidates include different alternating trailing edge (TE) waveforms, TE segment lengths, TE deflection amplitudes, and transition characteristics. The best design candidate among those explored is an anti-phase rotor that has a four-period TE waveform which results in a reduction in far-field noise level of 2.1 dB in the hover condition and a reduction of 1.1 dB in the forward flight condition at 9.7 m/s. A further acoustic study is conducted for a different rotor manufactured by APC. Five APC rotor design candidates are simulated. The best anti-phase design candidate for the APC rotor results in a reduction in far-field noise level of 4.0 dB in the hover condition. An in-phase design candidate is also studied. This in-phase design provides a noise reduction of 2.5 dB. A series of acoustic experiments in the PSU anechoic chamber have been conducted in July 2019 and October 2019. Both anti-phase and in-phase rotors fabricated for the left-hand and right-hand rotations are tested. In the hover condition, all the rotors do not provide sufficient evidence of improved acoustic performance. However, the experimental data in the hover condition are deemed to be inconclusive due to the flow recirculation in the anechoic chamber caused by the rotor downwash. In the forward flight condition at 9.7 m/s, the anti-phase right-hand rotor produces a noise reduction by as much as 6.5 dB in the frequency range of 2000-4000 Hz, while the in-phase right-hand rotor produces a noise reduction by as much as 5 dB in the same frequency range. Both the anti-phase and in-phase left hand rotors offer no evidence of noise reduction. The difference in the acoustic performance of the left-hand and right-hand rotors could be explained by the location of the microphone array which is placed to the left side of the rotors. This microphone array location could create a bias in the sound pressure level in favor of the right-hand rotor. Using the average noise reduction values, the anti-phase 4H rotor could offer a noise reduction by as much as 3.25 dB while the in-phase 4I rotor could produce up to a 2.5 dB noise reduction. Both the computational and experimental results have provided sufficient evidence to support the noise suppression capability of the proposed anti-phase rotor concepts.

Rotor noise↗

The superconducting diode effect in Josephson junctions fabricated from a structurally chiral superconductor

The superconducting diode effect occurs in superconducting materials in which both time-reversal and inversion symmetry are broken. The recently observed chirality-induced spin selectivity effect demonstrates that chiral materials break both symmetries. Thus, a Josephson junction interface with the left-handed structure on one side of the junction and the right-handed structure on the other should exhibit a diode effect. Here, we report the electrical transport properties of right-handed/left-handed and right-handed/right-handed devices fabricated from single crystals of the structurally chiral superconductor Mo 3 Al 2 C. Fraunhofer-like magnetic diffraction patterns confirm the presence of the Josephson effect in all but one of our devices. A magnetic-field-induced superconducting diode effect is demonstrated in the right-handed/left-handed devices by a statistically significant difference in I c + and ∣ I c −∣, with a maximum asymmetry of 5%. The intrinsic superconducting diode effect is not observed in the right-handed/right-handed devices. We provide an explanation for the presence of the superconducting diode effect in the right-handed/left-handed devices.

superconducting devices↗

Hesitations in continuous tracking induced by a concurrent discrete task

Subjects performed a continuous visually-guided pursuit tracking task with the right hand. From time to time (intervals averaging 30 sec) an auditory tone appeared signaling the subjects to perform a discrete response with the left hand. The presence of this tone was frequently associated with a hesitation in right-hand tracking which lasted 1/3 sec or longer. The rate of occurrence of these hesitations was about the same when the left-hand response involved a choice between competing responses as when the left hand responded in a predetermined direction. Hesitations occurred for three different mechanical tracking manipulanda using different controlling muscles, and appeared to be due to freezing rather than to relaxation of muscular action. The rate of occurrence of hesitations declined with practice, and this improvement in right-hand performance was accompanied by an improvement in performance of the concurrent left-hand response. The presence of hesitations, and their reduction with practice, can be interpreted within several viewpoints.

Klapp, S. T.↗

Hesitations in continuous tracking induced by a concurrent discrete task

Subjects performed a continuous visually-guided pursuit tracking task with the right hand. From time to time (intervals averaging 30 sec) an auditory tone appeared signaling the subjects to perform a discrete response with the left hand. The presence of this tone was frequently associated with a hesitation in right-hand tracking which lasted 1/3 sec or longer. The rate of occurrence of these hesitations was about the same when the left-hand response involved a choice between competing responses as when the left hand responded in a predetermined direction. Hesitations occurred for three different mechanical tracking manipulanda using different controlling muscles, and appeared to be due to freezing rather than to relaxation of muscular action. The rate of occurrence of hesitations declined with practice, and this improvement in right-hand performance was accompanied by an improvement in performance of the concurrent left-hand response. The presence of hesitations, and their reduction with practice, can be interpreted within several viewpoints.

Klapp, Stuart T.↗

Kinematics of the six-degree-of-freedom force-reflecting Kraft Master

Presented here are kinematic equations for a six degree of freedom force-reflecting hand controller. The forward kinematics solution is developed and shown in simplified form. The Jacobian matrix, which uses terms from the forward kinematics solution, is derived. Both of these kinematic solutions require joint angle inputs. A calibration method is presented to determine the hand controller joint angles given the respective potentiometer readings. The kinematic relationship describing the mechanical coupling between the hand and controller shoulder and elbow joints is given. These kinematic equations may be used in an algorithm to control the hand controller as a telerobotic system component. The purpose of the hand controller is two-fold: operator commands to the telerobotic system are entered using the hand controller, and contact forces and moments from the task are reflected to the operator via the hand controller.

Williams, Robert L., II↗

Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults With Amputations

The first single function myoelectric prosthetic hand was introduced in the 1960's. This hand was controlled by the electric fields generated by muscle contractions in the residual limb of the amputee user. Electrodes and amplifiers, embedded in the prosthetic socket, measured these electric fields across the skin, which increase in amplitude as the individual contracts their muscle. When the myoelectric signal reached a certain threshold amplitude, the control unit activated a motor which opened or closed a hand-like prosthetic terminal device with a pincher grip. Late in the 1990's, little has changed. Most current myoelectric prostheses still operate in this same, single-function way. To better understand the limitations of the current single-function myoelectric hand and the needs of those who use them, The Institute for Rehabilitation and Research (TIRR), sponsored by the National Institutes of Health (NUH), surveyed approximately 2,500 individuals with upper limb loss [1]. When asked to identify specific features of their current myoelectric prostheses that needed improvement, the survey respondents overwhelmingly identified the lack of wrist and finger movement, as well as poor control capability. However, simply building a mechanism with individual finger and wrist motion is not enough. In the 1960's and 1970's, engineers built a number of more dexterous prosthetic hands. Unfortunately, these were rejected during clinical trials due to a difficult and distracting control interface. The goal of this project, "Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults with Amputations," was to lay the foundation for a multi-function, intuitive myoelectric control system which requires no conscious thought to move the hand. We built an extensive myoelectric signal database for six motions from ten amputee volunteers, We also tested a control system based on new artificial intelligence techniques on the data from two of these subjects. This data is available to anyone doing myoelectric control research. Its availability is an important contribution to the prosthetics research community, as many researchers do not have access to amputee subjects. Since we collected myoelectric data from subjects' sound arms as well as their residual arms, this database will also prove useful to virtual reality and robotics researchers who want to explore myoelectric-based interfaces between any user and a machine. Currently, one small company (Intelligenta, Inc.) and one university (University of New Brunswick, Canada) are using this myoelectric database under other funding to develop multifunction control systems for prostheses. A prosthetics manufacturer (Liberty Technology, Inc.) is making plans to incorporate the results of their work into an artificial hand capable of several different movements to provide functionality only dreamed of by current myoelectric users. Methods Six adults and four children, all with unilateral, below-elbow amputations served as subjects. Five of the adults (3 male, 2 female, average age 34 years) had amputations due to traumatic injury, while one adult (female, age 32 years) and the four children (3 male, 1 female, average age 13 years) had congenital (i.e. from birth) limb deficiencies.

Atkins, Diane J.↗

Using the Space Glove to Teach Spatial Thinking

The challenge of extending students' skills in spatial thinking to astronomical scales was the central focus of our K-8 curriculum development. When the project's lead teacher requested a curriculum that cumulatively built on each prior year's learning in a spiral fashion, I knew exactly what the school was asking for. Second and third graders began by noticing the cyclical patters that the sun, moon, and stars make in the sky. Fourth graders explored the phases of the moon by taking turns modeling and sketching them in their classroom and then comparing them to the real sky. Sixth !graders used real telescopes to observe a moving model of our solar system and walked a scale model of the planets' orbits. The curriculum is designed to expand students' capacity to visualize space in a hierarchical fashion that asks them to imagine themselves from a broader number of spatial perspectives through hands-on activities. The "situational awareness" Peter's story describes is a hallmark of high-performance engineering and innovation. Keeping in mind the potential outcomes of multiple paths of pursuit from multiple perspectives while keeping track of their relative merits and performance requirements is a demanding spatial task. What made it possible for Peter to transform the failure of his first glove into triumph was the mental space in which that failure provided exactly the information needed for a new breakthrough. In at least two cases, Peter could immediately "see" the full implications of what his hands were telling him. He tells the story of how putting his hands in a Phase VI astronaut glove instantly transformed his understanding of the glove challenge. Six months into his development, the failure of circumferentially wrapped cords to produce a sufficiently flexible glove again forced him to abandon his assumptions. His situational awareness was so clear and compelling it became a gut-level response. Peter's finely developed spatial skills enabled him to almost instinctively focus his full energy on a carefully constructed set of experiments. The finger's ability to sense pressure, force, and work gave him the immediate feedback required to solve this one central problem. Once properly understood, his failure quickly led to the magical "Aha!" moment of discovery; the rest is history. Just as children need opportunities to develop hands-on understanding, engineers need to explore new possibilities through incremental hands-on failure. High-performance innovation is all about learning to make maximum use of thinking spatially to direct this process. Peter Homer's glove also reminds us that efficient engineering decisions need to be made as close to the hardware as possible. Whether we're doing hands-on education or hands-on engineering, it is when we trust in our ability to "feel our way" through failure that we reach our highest potential.

Lord, Peter↗

Assessing the Role of Hydrodynamics in Enhancing Height-Above-the-Nearest-Drainage Derived Synthetic Rating Curves: A Comparative Study in the Wu River Basin, Taiwan

The conventional approach to generating synthetic rating curves (SRC) using the Height-Above-the-Nearest-Drainage (HAND) method typically relies on the assumption of uniform flow, such as Manning's equation, to establish stage-discharge ratings. The zero-physics application of the uniform flow equation is insufficient for capturing detailed hydraulic features (e.g., backwater effect) and neglects the hydraulic effects from adjacent channels. This lack of hydrodynamic computation can impact the accuracy and effectiveness of riverine flood risk estimation and management. To reduce this foreseeable error, we introduce the HAND-hd workflow, which integrates sophisticated hydrodynamic computations in the production of HAND-based SRC with hydrodynamic features (SRC hd ). The results indicate that SRC hd demonstrates consistent agreement with both gauge observations and benchmark solutions. Additionally, the comparative analysis suggests that SRC hd provides notable improvements in stage-discharge ratings over conventional HAND-based SRCs, particularly in channels with mild bed gradients, where it reduces water stage prediction errors and percent biases. In steeper channel segments, SRC hd maintains comparable accuracy to conventional methods. The comprehensive evaluation in this study emphasizes the potential discrepancies and inaccuracies associated with the adoption of the uniform flow assumption in the conventional HAND-SRCs and addresses the necessity of including hydrodynamic physics in the application of HAND-based SRC (e.g., inundation map) in channels with mild gradients.

54 ENVIRONMENTAL SCIENCES↗

Anthropomorphic Telemanipulation System in Terminus Control Mode

This paper describes a prototype anthropomorphic kinesthetic telepresence system that is being developed at JPL. It utilizes dexterous terminus devices in the form of an exoskeleton force-sensing master glove worn by the operator and a replica four finger anthropomorphic slave hand. The newly developed master glove is integrated with our previously developed non-anthropomorphic six degree of freedom (DOF) universal force-reflecting hand controller (FRHC). The mechanical hand and forearm are mounted to an industrial robot (PUMA 560), replacing its standard forearm. The notion of 'terminus control mode' refers to the fact that only the terminus devices (glove and robot hand) are of anthropomorphic nature, and the master and slave arms are non-anthropomorphic. The system is currently being evaluated, focusing on tool handling and astronaut equivalent task executions. The evaluation revealed the system's potential for tool handling but it also became evident that hand tool manipulations and space operations require a dual arm robot. This paper describes the system's principal components, its control and computing architecture, discusses findings of the tool handling evaluation, and explains why common tool handling and EVA space tasks require dual arm robots.

glove exoskeleton force-sensing master glove EVA s↗

Snakes for the Hadron Storage Ring

The Electron Ion Collider calls for collisions of polarized proton and polarized helion beams on polarized electron beams. To preserve polarization of these polarized hadron beams during acceleration, six full helical snakes will be installed. As there are currently 4 snakes in RHIC, the remaining two snakes will be made from existing rotator magnet coils. The existing snakes are made from only right-handed helices where the rotator magnets are made from both right handed and left handed helicity magnets. In order for a sufficient stock of spare coils, one snake will be made of left handed coils. Simulations using Opera field maps in zgoubi show the left handed snake has sufficient range to provide the desired snake precession axes for helions and protons with the existing power supplies. This is an overview of the right and left handed snake assemblies and their effects.

43 PARTICLE ACCELERATORS↗

Semiannual Status Report

During the last six months, we have continued our study of the excitation of electromagnetic waves in the whistler frequency range and the role that these waves will play in the acceleration of electrons and ions in the auroral region. A paper entitled 'Electron Beam Excitation of Upstream Waves in the Whistler Mode Frequency Range' was listed in the Journal of Geophysical Research. In this paper, we have shown that an anisotropic electron beam (or gyrating electron beam) is capable of generating both left-hand and right-hand polarized electromagnetic waves in the whistler frequency range. Since right-hand polarized electromagnetic waves can interact with background electrons and left-hand polarized waves can interact with background ions through cyclotron resonance, it is possible that these beam generated left-hand and right-hand polarized electromagnetic waves can accelerate either ions or electrons (or both), depending on the physical parameters under consideration. We are currently carrying out a comprehensive study of the electromagnetic whistler and lower hybrid like waves observed in the auroral zone using both wave and particle data. Our first task is to identify these wave modes and compare it with particle observations. Using both the DE-1 particle and wave measurements, we can positively identify those electromagnetics lower hybrid like waves as fast magnetosonic waves and the upper cutoff of these waves is the local lower hybrid frequency. From the upper cutoff of the frequency spectrum, one can infer the particle density and the result is in very good agreement with the particle data. Since these electromagnetic lower hybrid like waves can have frequencies extended down to the local ion cyclotron frequency, it practically confirms that they are not whistler waves.

Source record↗

Mobility management in satellite networks

This paper addresses the methods used or proposed for use in multi-beam and/or multi-satellite networks designed to provide Mobile Satellite Services (MSS). Specific topics include beam crossover in the North American Mobile Satellite (MSAT) system as well as registration and live call hand-off for a multi-regional geosynchronous (GEO) satellite based system and a global coverage Low Earth Orbiting (LEO) system. In the MSAT system, the individual satellite beams cover very large geographic areas so the need for live call hand-off was not anticipated. This paper discusses the methods used to keep track of the beam location of the users so that incoming call announcements or other messages may be directed to them. Proposed new GEO systems with large numbers of beams will provide much smaller geographic coverage in individual beams and thus the need arises to keep track of the user's location as well as to provide live call hand-off as the user traverses from beam to beam. This situation also occurs in proposed LEO systems where the problems are worsened by the need for satellite to satellite hand-off as well as beam to beam hand-off within a single satellite. The paper discusses methods to accomplish these handoffs and proposes system architectures to address the various hand-off scenarios.

Johanson, Gary A.↗

An Assessment of Molten Metal Detachment Hazards During Electron Beam Welding in the Space Shuttle Bay at LEO for the International Space Welding Experiment

In 1997, the United States [NASA] and the Paton Electric Welding Institute are scheduled to cooperate in a flight demonstration on the U.S. Space Shuttle to demonstrate the feasibility of welding in space for a possible repair option for the International Space Station Alpha. This endeavor, known as the International Space Welding Experiment (ISWE), will involve astronauts performing various welding exercises such as brazing, cutting, welding, and coating using an electron beam space welding system that was developed by the E.O. Paton Electric Welding Institute (PWI), Kiev Ukraine. This electron beam welding system known as the "Universal Weld System" consists of hand tools capable of brazing, cutting, autogeneous welding, and coating using an 8 kV (8000 volts) electron beam. The electron beam hand tools have also been developed by the Paton Welding Institute with greater capabilities than the original hand tool, including filler wire feeding, to be used with the Universal Weld System on the U.S. Space Shuttle Bay as part of ISWE. The hand tool(s) known as the Ukrainian Universal Hand [Electron Beam Welding] Tool (UHT) will be utilized for the ISWE Space Shuttle flight welding exercises to perform welding on various metal alloy samples. A total of 61 metal alloy samples, which include 304 stainless steel, Ti-6AI-4V, 2219 aluminum, and 5456 aluminum alloys, have been provided by NASA for the ISWE electron beam welding exercises using the UHT. These samples were chosen to replicate both the U.S. and Russian module materials. The ISWE requires extravehicular activity (EVA) of two astronauts to perform the space shuttle electron beam welding operations of the 61 alloy samples. This study was undertaken to determine if a hazard could exist with ISWE during the electron beam welding exercises in the Space Shuttle Bay using the Ukrainian Universal Weld System with the UHT. The safety issue has been raised with regard to molten metal detachments as a result of several possible causes such as welder procedural error, externally applied impulsive forces(s), filler wire entrainment and snap-out, cutting expulsion, and puddle expulsion. Molten metal detachment from either the weld/cut substrate or weld wire could present harm to a astronaut in the space environment it the detachment was ti burn through the fabric of the astronaut Extravehicular Mobility Unit (EMC). In this paper an experimental test was performed in a 4 ft. x 4 ft. vacuum chamber at MSFC enabling protective garment to be exposed to the molten metal drop detachments to over 12 inches. The chamber was evacuated to vacuum levels of at least 1 x 10(exp -5) torr (50 micro-torr) during operation of the 1.0 kW Universal Hand Tool (UHT). The UHT was manually operated at the power mode appropriate for each material and thickness. The space suit protective welding garment, made of Teflon fabric (10 oz. per yard) with a plain weave, was placed on the floor of the vacuum chamber to catch the molten metal drop detachments. A pendulum release mechanism consisting of four hammers, each weighing approximately 3.65 lbs, was used to apply an impact forces to the weld sample/plate during both the electron beam welding and cutting exercises. Measurements were made of the horizontal fling distances of the detached molten metal drops. The volume of a molten metal drop can also be estimated from the size of the cut. Utilizing equations, calculations were made to determine chande in surafec area (Delat a(surface)) for 304 stainless steel for cutting based on measurements of metal drop sizes at the cut edges. For the cut sample of 304 stainless steel based on measurement of the drop size at the edge, Delta-a(surface) was determined to be 0.0054 2 in . Calculations have indicated only a small amount of energy is required to detach a liquid metal drop. For example, approximately only 0.000005 ft-lb of energy is necessary to detach a liquid metal steel drop based on the above theoretical analysis. However, some of the energy will be absorbed by the plate before it reaches the metal drop. Based on the theoretical calculations, it was determined that during a weld cutting exercise, the titanium alloy would be the most difficult to detach molten metal droplets followed by stainless steel and then by aluminum. The results of the experimental effort have shown that molten metal will detach if large enough of a hammer blow is applied to the weld sample plate during the full penetration welding and cutting exercises. However, no molten metal detachments occurred as a result of the filler wire snap-out tests from the weld puddle since it was too difficult to cause the metal to flick-out from the pool. Molten metal detachments, though not large in size, did result from the direct application of the electron beam on the end of the filler weld wire.

Fragomeni, James M.↗

Small Business Innovations (Exoskeletons)

The Dexterous Hand Master (DHM), a 1989 winner of an R&D 100 Award, is an exoskeleton device for measuring the joints of the human hand with extreme precision. It was originally developed for NASA by Arthur D. Little, and is sold commercially by EXOS, Inc. The DHM is worn on the hand and connected to a computer that records hand motions. The resulting data is transmitted as control signals to robots and other computers, enabling robotic hands to emulate human hand actions. Two additional spinoff products were also inspired by the DHM.

Source record↗