Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Overcoming the doping limit in GaAs by ion implantation and pulsed laser melting

Most semiconductors exhibit a saturation of free carriers when heavily doped with extrinsic dopants. This carrier saturation or “doping limit” is known to be related to the formation of native compensating defects, which, in turn, depends on the energy positions of their conduction band minimum and valence band maximum. Here, we carried out a systematic study on the n-type doping limit of GaAs via ion implantation and showed that this doping limitation can be alleviated by the transient process of pulsed laser melting (PLM). For n-type doping, both group VI (S) and amphoteric group IV (Si and Ge) dopants were implanted in GaAs. For comparison, p-type doping was also studied using Zn as the acceptor. Implanted dopants were activated by the PLM method, and the results are compared to rapid thermal annealing (RTA). Our results reveal that for all n-type dopants, while implantation followed by the RTA results in a similar saturation electron concentration of 2–3 × 10 18 cm –3 , the transient PLM process is capable of trapping high concentration of dopants in the substitutional site, giving rise to a carrier concentration of >10 19 cm –3 , exceeding the doping limit of GaAs. However, due to scatterings from point defects generated during PLM, the mobility of n-type GaAs after PLM is low (~80–260 cm 2 /V s). Subsequent RTA after PLM (PLM + RTA) is able to remove these point defects and recover the mobility to ~1000–2000 cm2/V s. The carrier concentrations of these PLM + RTA samples are reduced but are still a factor of 3 higher than RTA only GaAs. This can be understood as the dopants are already incorporated in the substitutional site after PLM; they are less likely to be “deactivated” by subsequent RTA. This work is significant to the understanding of doping mechanisms in semiconductors and provides a means for device applications, which require materials with ultra-high doping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Field-dependent carrier transport in implanted isolation region of GaN lateral power devices

Among GaN lateral power devices, with proper E-field management, the breakdown occurs in the device isolation region rather than the active region. In this paper, we investigate field-dependent carrier transport in the isolation structures. Isolation test structures with variations in buffer doping, un-intentionally doped (UID) GaN thickness, and implantation conditions were fabricated. Electrical characterization was performed over a wide range of voltage and temperature. With varying UID GaN thickness and buffer doping, the leakage current and breakdown characteristics remain the same for a specific implantation condition, indicating that the leakage conduction and breakdown are governed by the implanted GaN region. Analysis of the temperature-dependent I–V reveals that carrier transport in the implanted GaN can be well explained by hopping conduction, involving three distinctive regions of operation depending on the E-field. At low E-field, carrier transport is ohmic, consistent with variable range hopping, driven by thermal activation. At medium E-field, a field enhanced thermally activated hopping is observed, following σ ∼ σ(T)exp(E). At high E-field, activation-less hopping is visible, following σ ∼ exp(−1/E), which occurs above a critical E-field limited by localization length.

Sadek, Mansura (ORCID:0000000322588338)↗

Implanted satellite transmitters affect sea duck movement patterns at short and long timescales

Abstract Studies of the effects of transmitters on wildlife often focus on survival. However, sublethal behavioral changes resulting from radio-marking have the potential to affect inferences from telemetry data and may vary based on individual and environmental characteristics. We used a long-term, multi-species tracking study of sea ducks to assess behavioral patterns at multiple temporal scales following implantation of intracoelomic satellite transmitters. We applied state-space models to assess short-term behavioral patterns in 476 individuals with implanted satellite transmitters, as well as comparing breeding site attendance and migratory phenology across multiple years after capture. In the short term, our results suggest an increase in dispersive behavior immediately following capture and transmitter implantation; however, behavior returned to seasonally average patterns within ~5 days after release. Over multiple years, we found that breeding site attendance by both males and females was depressed during the first breeding season after radio-marking relative to subsequent years, with larger relative decreases in breeding site attendance among males than females. We also found that spring and breeding migrations occurred later in the first year after radio-marking than in subsequent years. Across all behavioral effects, the severity of behavioral change often varied by species, sex, age, and capture season. We conclude that, although individuals appear to adjust relatively quickly (i.e. within 1 week) to implanted satellite transmitters, changes in breeding phenology may occur over the longer term and should be considered when analyzing and reporting telemetry data.

Lamb, Juliet S.↗

Ferromagnetism in Mn-Implanted Epitaxially Grown Ge on Si(100)

We have studied ferromagnetism of Mn-implanted epitaxial Ge films on silicon. The Ge films were grown by ultrahigh vacuum chemical vapor deposition using a mixture of germane (GeH{sub 4}) and methylgermane (CH{sub 3}GeH{sub 3}) gases with a carbon concentration of less than 1 at. %, and observed surface rms roughness of 0.5 nm, as measured by atomic force microscopy. Manganese ions were implanted in epitaxial Ge films grown on Si (100) wafers to an effective concentration of 16, 12, 6, and 2 at. %. Superconducting quantum interference device measurements showed that only the three highest Mn concentration samples are ferromagnetic, while the fourth sample, with [Mn] = 2 at. %, is paramagnetic. X-ray absorption spectroscopy and x-ray magnetic circular dichroism measurements indicate that localized Mn moments are ferromagnetically coupled below the Curie temperature. Isothermal annealing of Mn-implanted Ge films with [Mn] = 16 at. % at 300 C for up to 1200 s decreases the magnetization but does not change the Curie temperature, suggesting that the amount of the magnetic phase slowly decreases with time at this anneal temperature. Furthermore, transmission electron microscopy and synchrotron grazing incidence x-ray diffraction experiments show that the Mn-implanted region is amorphous, and we believe that it is this phase that is responsible for the ferromagnetism. This is supported by our observation that high-temperature annealing leads to recrystallization and transformation of the material into a paramagnetic phase.

36 MATERIALS SCIENCE↗

AIDA: A 16-channel amplifier ASIC to read out the advanced implantation detector array for experiments in nuclear decay spectroscopy

We have designed a read-out ASIC for nuclear decay spectroscopy as part of the AIDA project - the Advanced Implantation Detector Array. AIDA will be installed in experiments at the Facility for Antiproton and Ion Research in GSI, Darmstadt. The AIDA ASIC will measure the signals when unstable nuclei are implanted into the detector, followed by the much smaller signals when the nuclei subsequently decay. Implant energies can be as high as 20 GeV; decay products need to be measured down to 25 keV within just a few microseconds of the initial implants. The ASIC uses two amplifiers per detector channel, one covering the 20 GeV dynamic range, the other selectable over a 20 MeV or 1 GeV range. The amplifiers are linked together by bypass transistors which are normally switched off. The arrival of a large signal causes saturation of the low-energy amplifier and a fluctuation of the input voltage, which activates the link to the high-energy amplifier. The bypass transistors switch on and the input charge is integrated by the high-energy amplifier. The signal is shaped and stored by a peak-hold, then read out on a multiplexed output. Control logic resets the amplifiers and bypass circuit, allowing the low-energy amplifier to measure the subsequent decay signal. We present simulations and test results, demonstrating the AIDA ASIC operation over a wide range of input signals. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RBS-channeling study of radiation damage in Ar{sup +} implanted CuInSe{sub 2} crystals

Chalcopyrite solar cells are reported to have a high tolerance to irradiation by high energy electrons or ions, but the origin of this is not well understood. This work studies the evolution of damage in Ar{sup +}-bombarded CuInSe{sub 2} single crystal using Rutherford backscattering/channeling analysis. Ar{sup +} ions of 30 keV were implanted with doses in the range from 10{sup 12} to 3 × 10{sup 16} cm{sup −2} at room temperature. Implantation was found to create two layers of damage: (1) on the surface, caused by preferential sputtering of Se and Cu atoms; (2) at the layer of implanted Ar, possibly consisting of stacking faults and dislocation loops. The damage in the second layer was estimated to be less than 2% of the theoretical prediction suggesting efficient healing of primary implantation defects.

36 MATERIALS SCIENCE↗

SU-E-I-42: Normalized Embryo/fetus Doses for Fluoroscopically Guided Pacemaker Implantation Procedures Calculated Using a Monte Carlo Technique

Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestation were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)

60 APPLIED LIFE SCIENCES↗

SU-E-J-257: Image Artifacts Caused by Implanted Calypso Beacons in MRI Studies

Purpose: The presence of Calypso Beacon-transponders in patients can cause artifacts during MRI imaging studies. This could be a problem for post-treatment follow up of cancer patients using MRI studies to evaluate metastasis and for functional imaging studies.This work assesses (1) the volume immediately surrounding the transponders that will not be visualized by the MRI due to the beacons, and (2) the dependence of the non-visualized volume on beacon orientation, and scanning techniques. Methods: Two phantoms were used in this study (1) water filled box, (2) and a 2300 cc block of pork meat. Calypso beacons were implanted in the phantoms both in parallel and perpendicular orientations with respect to the MR scanner magnetic field. MR image series of the phantom were obtained with on a 1.0T high field open MR-SIM with multiple pulse sequences, for example, T1-weighted fast field echo and T2-weighted turbo spin echo. Results: On average, a no-signal region with 2 cm radius and 3 cm length was measured. Image artifacts are more significant when beacons are placed parallel to scanner magnetic field; the no-signal area around the beacon was about 0.5 cm larger in orthogonal orientation. The no-signal region surrounding the beacons slightly varies in dimension for the different pulse sequences. Conclusion: The use of Calypso beacons can prohibit the use of MRI studies in post-treatment assessments, especially in the immediate region surrounding the implanted beacon. A characterization of the MR scanner by identifying the no-signal regions due to implanted beacons is essential. This may render the use of Calypso beacons useful for some cases and give the treating physician a chance to identify those patients prior to beacon implantation.

60 APPLIED LIFE SCIENCES↗

Photoluminescence in silicon implanted with silicon ions at amorphizing doses

Luminescent and structural properties of n-FZ-Si and n-Cz-Si implanted with Si ions at amorphizing doses and annealed at 1100 Degree-Sign C in a chlorine-containing atmosphere have been studied. An analysis of proton Rutherford backscattering spectra of implanted samples demonstrated that an amorphous layer is formed, and its position and thickness depend on the implantation dose. An X-ray diffraction analysis revealed that defects of the interstitial type are formed in the samples upon annealing. Photoluminescence spectra measured at 78 K and low excitation levels are dominated by the dislocation-related line D1, which is also observed at 300 K. The peak position of this line, its full width at half-maximum, and intensity depend on the conduction type of Si and implantation dose. As the luminescence excitation power is raised, a continuous band appears in the spectrum. A model is suggested that explains the fundamental aspects of the behavior of the photoluminescence spectra in relation to the experimental conditions.

36 MATERIALS SCIENCE↗

Formation of Precipitates in Si Implanted with {sup 64}Zn{sup +} and {sup 16}O{sup +} Ions

The results of studying the surface Si layer and precipitate formation in CZ n-Si(100) samples sequentially implanted with {sup 64}Zn{sup +} ions with a dose of 5 × 10{sup 16} cm{sup 2} and energy of 100 keV and {sup 16}O{sup +} ions with the same dose but an energy of 33 keV at room temperature so that their projection paths R{sub p} = 70 nm would coincide are presented. The post-implantation samples are annealed for 1 h in an inert Ar medium in the temperature range of 400–900°C with a step of 100°C. The profiles of the implanted impurities are studied by time-of-flight secondary ion mass spectrometry. The Si surface is visualized using a scanning electron microscope, while the near-surface layer is visualized with the help of maps of elements formed by Auger electron spectroscopy with profiling over depth. The ZnO(002) texture is formed in an amorphized Si layer after the implantation of Zn and O ions. ZnO(102) crystallites of 5 nm in size are found in a recrystallized single-crystalline Si layer after annealing in Ar at 700°C.

36 MATERIALS SCIENCE↗

Dislocation-Related Photoluminescence in Silicon Implanted with Germanium Ions

The influence exerted by the conditions of the post-implantation annealing of silicon implanted with germanium ions on how luminescence centers are formed is studied. Measurements by the technique of the Rutherford backscattering of medium- and high-energy ions demonstrates that implantation with 1-MeV germanium ions at a dose of 1.5 × 10{sup 14} cm{sup –2} does not lead to the amorphization of single-crystal silicon. It is found that subsequent high-temperature annealing of the implanted samples in a chlorine-containing atmosphere at a temperature of 1100°C for 0.5–1.5 h gives rise to so-called D1 and D2 dislocation-related luminescence lines with wavelengths of 1.54 and 1.42 μm. With increasing annealing duration, the intensity of the D1 line decreases and that of D2 remains constant, but the D1 line dominates in all the spectra. The possible factors responsible for a decrease in the intensity of the D1 line and, in particular, the diffusion of germanium atoms and the formation of a silicon–germanium solid solution are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A comparison of single-suture and double-suture incision closures in seaward-migrating juvenile Chinook salmon implanted with acoustic transmitters: implications for research in river basins containing hydropower structures

Reductions in the size of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the ability to make shorter incisions that may warrant using only a single suture for closure. However, it is not known if one suture will sufficiently hold the incision closed, particularly when outward pressure is placed on the surgical site such as when migrating fish experience pressure changes associated with passage at hydroelectric dams. The objective of this research was to evaluate the effectiveness of single-suture incision closures on juvenile Chinook salmon (Oncorhynchus tshawytscha). Juvenile Chinook salmon were surgically implanted with a 2012 Juvenile Salmon Acoustic Telemetry System (JSATS) transmitter (0.30 g) and a passive integrated transponder tag (0.10 g) and incisions were closed with either one suture or two sutures. Mortality and tag retention were monitored and fish were examined after 7 and 14 days to evaluate tissue responses. In a separate experiment, surgically implanted fish were exposed to simulated turbine passage and then examined for expulsion of transmitters, expulsion of viscera through the incision, and mortal injury. With incisions closed using a single suture, there was no mortality or tag loss and similar or reduced tissue reaction compared to incisions closed with two sutures. Further, surgery time was significantly reduced when one suture was used, which leads to less handling and reduced stress. No tags were expelled during pressure scenarios and expulsion of viscera only occurred in two non-mortally injured fish (5%) with single sutures that were also exposed to very high pressure changes. No viscera expulsion was present in fish exposed to pressure scenarios likely representative of hydroturbine passage at many Columbia River dams (e.g. <2.7 ratio of pressure change; an acclimation pressure of 146.2 absolute kpa and a lowest exposure pressure of ~ 53.3 absolute kpa). Based on these results, we recommend the use of a single suture for surgical implantation of transmitters with incisions that are approximately 5 1/2 mm long after tag insertion.

Brown, Richard S.↗

The Efficacy of Ultraviolet Radiation for Sterilizing Tools Used for Surgically Implanting Transmitters into Fish

Telemetry is frequently used to examine the behavior of fish, and the transmitters used are normally surgically implanted into the coelom of fish. Implantation requires the use of surgical tools such as scalpels, forceps, needle holders, and sutures. When several fish are implanted consecutively for large telemetry studies, it is common for surgical tools to be sterilized or, at minimum, disinfected between each use so that pathogens that may be present are not spread among fish. However, autoclaving tools can take a long period of time, and chemical sterilants or disinfectants can be harmful to both humans and fish and have varied effectiveness. Ultraviolet (UV) radiation is commonly used to disinfect water in aquaculture facilities. However, this technology has not been widely used to sterilize tools for surgical implantation of transmitters in fish. To determine its efficacy for this application, Pacific Northwest National Laboratory researchers used UV radiation to disinfect surgical tools (i.e., forceps, needle holder, stab scalpel, and suture) that were exposed to one of four aquatic organisms that typically lead to negative health issues for salmonids. These organisms included Aeromonas salmonicida, Flavobacterium psychrophilum, Renibacterium salmoninarum, and Saprolegnia parasitica. Surgical tools were exposed to the bacteria by dipping them into a confluent suspension of three varying concentrations (i.e., low, medium, high). After exposure to the bacterial culture, tools were placed into a mobile Millipore UV sterilization apparatus. The tools were then exposed for three different time periods—2, 5, or 15 min. S. parasitica, a water mold, was tested using an agar plate method and forceps-pinch method. UV light exposures of 5 and 15 min were effective at killing all four organisms. UV light was also effective at killing Geobacillus stearothermophilus, the organism used as a biological indicator to verify effectiveness of steam sterilizers. These techniques appear to provide a quick alternative disinfection technique for some surgical tools that is less harmful to both humans and fish while not producing chemical waste. However, we do not recommend using these methods with tools that have overlapping parts or other structures that cannot be directly exposed to UV light such as needle holders.

Walker, Ricardo W.↗

Radiation Modified Ion-Implanted Materials

The objective of this project, by BNL and PVI, is to develop radiation-modified materials like titanium, nickel, aluminum, steel, refractory metals and alloys by implanting them with ions. Ion implantation radically improves strength & friction resistance. The focus will be on components of products like jet engines & windmills. Example: implanting windmill parts subject to friction may greatly reduce operating costs. Currently, electric power from wind is a factor of 1.5 more costly than coal due to labor costs [frequent lubrication of parts involves stopping a windmill & opening its nacelle (enclosures)]. A 50% friction reduction through ion implantation of parts will reduce the need for lubricants and make wind-generated electricity cheaper than fossil fuel. Major PVI role is adapting laboratory experimental results into commercially viable industrial processes and marketing them.

36 MATERIALS SCIENCE↗

Nanostructures from hydrogen implantation of metals.

This study investigates a pathway to nanoporous structures created by hydrogen implantation in aluminum. Previous experiments for fusion applications have indicated that hydrogen and helium ion implantations are capable of producing bicontinuous nanoporous structures in a variety of metals. This study focuses specifically on hydrogen and helium implantations of aluminum, including complementary experimental results and computational modeling of this system. Experimental results show the evolution of the surface morphology as the hydrogen ion fluence increases from 10{sup 17} cm{sup -2} to 10{sup 18} cm{sup -2}. Implantations of helium at a fluence of 10{sup 18} cm{sup -2} produce porosity on the order of 10 nm. Computational modeling demonstrates the formation of alanes, their desorption, and the resulting etching of aluminum surfaces that likely drives the nanostructures that form in the presence of hydrogen.

08 HYDROGEN↗

Noninvasive Detection, Tracking, and Characterization of Aerogel Implants Using Diagnostic Ultrasound

Medical implants are routinely tracked and monitored using different techniques, such as MRI, X-ray, and ultrasound. Due to the need for ionizing radiation, the two former methods pose a significant risk to tissue. Ultrasound imaging, however, is non-invasive and presents no known risk to human tissue. Aerogels are an emerging material with great potential in biomedical implants. While qualitative observation of ultrasound images by experts can already provide a lot of information about the implants and the surrounding structures, this paper describes the development and study of two simple B-Mode image analysis techniques based on attenuation measurements and echogenicity comparisons, which can further enhance the study of the biological tissues and implants, especially of different types of biocompatible aerogels.

36 MATERIALS SCIENCE↗

Wear Measurement of Highly Cross-linked UHMWPE using a 7 Be Tracer Implantation Technique

The very low wear rates achieved with the current highly cross-linked ultrahigh molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are there- fore being explored. The purpose of this study was to perform a proof-of-concept experiment on the use of the radioactive tracer beryllium-7 (7Be) for the determination of in vitro wear in a highly cross-linked orthopedic UHMWPE. Three cross-linked and four conventional UHMWPE pins made from compression- molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenous distribution of implanted nuclei up to 8.5 lm below the surface. The pins were tested for wear in a six-station pin-on-flat appara- tus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and esti- mated to be 17 6 3 lg per million cycles. The conventional-to- cross-linked ratio of the wear rates was 13.1 6 0.8, in the expected range for these materials. Oxidative degradation dam- age from implantation was negligible; however, a weak depend- ence of wear on implantation dose was observed limiting the number of radioactive tracer atoms that can be introduced. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.

cross-linked↗

DIFFUSION OF MAGNESIUM AND MICROSTRUCTURES IN Mg+ IMPLANTED SILICON CARBIDE

Following our previous reports [ 1- 3], further isochronal annealing (2 hrs.) of the monocrystalline 6H-SiC and polycrystalline CVD 3C-SiC was performed at 1573 and 1673 K in Ar environment. SIMS data indicate that observable Mg diffusion in 6H-SiC starts and a more rapid diffusion in CVD 3C-SiC occurs at 1573 K. The implanted Mg atoms tend to diffuse deeper into the undamaged CVD 3C-SiC. The microstructure with Mg inclusions in the as-implanted SiC has been initially examined using high-resolution STEM. The presence of Mg in the TEM specimen has been confirmed based on EDS mapping. Additional monocrystalline 3C-SiC samples have been implanted at 673 K to ion fluence 3 times higher than the previous one. RBS/C analysis has been performed before and after thermal annealing at 1573 K for 12 hrs. Isothermal annealing at 1573 K is being carried out and Mg depth profiles being measured. Microstructures in both the as-implanted and annealed samples are also being examined using STEM.

Jiang, Weilin↗