Search NASA⌕ Search

SEARCH · Search NASA

Results for “INDEXES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

SU-E-I-52: Effect of Various X-Ray Beam Qualities On the Exposure Index

Purpose: The exposure index (EI) proposed by the International Electrotechnical Commission (IEC) 62494-1 is expected to be utilized as a standard dose index by every manufacturer. The IEC recommended the usage of RQA5 for the EI. However, X-ray beam qualities, particularly in clinical practices, vary depending on the examination objects and exposure conditions, including usage of anti-scatter grids. We investigated the effects of the X-ray beam qualities other than RQA5 on the EI. Methods: The Xray beam qualities of RQA3, 5, 7, and 9 in IEC 61267 Ed. 1.0 were adopted in a computed radiography system. A uniform exposure without objects was performed to measure the exposure indicators (S values) and air kerma (K). The relational equations between the S values and K were derived for the determination of the EI values. The EI values for RQA3, 7, and 9 were compared to those for RQA5 at the fixed S values of 100, 200, 400, and 600. Finally, the half-value layers (HVLs) using four grids (ratio 6:1, 8:1, 10:1, and 12:1) for the RQA5 X-ray were compared to those with RQA3–9. Results: The EI values for RQA3, 7, and 9 were up to 35.3%, 11.8%, and 38.7% higher, respectively, than that for RQA5 at the S value of 600. The HVLs without grids and with various grids for RQA5 were 6.85 mm Al. and in the range of 6.94–7.29 mm Al. (ΔHVL: up to 0.44 mm Al.), respectively. This variation in the HVLs with grids was smaller than that observed for RQA3–9 (ΔHVL: 2.0–7.5 mm Al.). Conclusion: Although the usage of grids may not greatly affect the EI, the X-ray beam quality for the determination of the EI cannot be ignored in the clinical evaluation of the dose index.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing the query performance of block index through data analysis and I/O modeling

Indexing technique has become an efficient tool to enable scientists to directly access the most relevant data records. But, the time and space requirements of building and storing indexes are expensive in the traditional approaches, such as R-tree and bitmaps. Recently, we started to address this issue by using the idea of "block index", and our previous work has shown promising results from comparing it against other well-known solutions, including ADIOS, SciDB, and FastBit. In this work, we further improve the technique from both theoretical and implementation perspectives. Driven by an extensive effort in characterizing scientific datasets and modeling I/O systems, we presented a theoretical model to analyze its query performance with respect to a given block size configuration. We also introduced three optimization techniques to achieve a 2.3x query time reduction comparing to the original implementation.

Wu, Tzuhsien↗

Optimizing the Four-Index Integral Transform Using Data Movement Lower Bounds Analysis

The four-index integral transform is a fundamental and computationally demanding calculation used in many computational chemistry suites such as NWChem. It transforms a four-dimensional tensor from an atomic basis to a molecular basis. This transformation is most efficiently implemented as a sequence of four tensor contractions that each contract a four-dimensional tensor with a two-dimensional transformation matrix. Differing degrees of permutation symmetry in the intermediate and final tensors in the sequence of contractions cause intermediate tensors to be much larger than the final tensor and limit the number of electronic states in the modeled systems. Loop fusion, in conjunction with tiling, can be very effective in reducing the total space requirement, as well as data movement. However, the large number of possible choices for loop fusion and tiling, and data/computation distribution across a parallel system, make it challenging to develop an optimized parallel implementation for the four-index integral transform. We develop a novel approach to address this problem, using lower bounds modeling of data movement complexity. We establish relationships between available aggregate physical memory in a parallel computer system and ineffective fusion configurations, enabling their pruning and consequent identification of effective choices and a characterization of optimality criteria. This work has resulted in the development of a significantly improved implementation of the four-index transform that enables higher performance and the ability to model larger electronic systems than the current implementation in the NWChem quantum chemistry software suite.

Rajbhandari, Samyam↗

VariantStore: an index for large-scale genomic variant search

Abstract Efficiently scaling genomic variant search indexes to thousands of samples is computationally challenging due to the presence of multiple coordinate systems to avoid reference biases. We present VariantStore, a system that indexes genomic variants from multiple samples using a variation graph and enables variant queries across any sample-specific coordinate system. We show the scalability of VariantStore by indexing genomic variants from the TCGA project in 4 h and the 1000 Genomes project in 3 h. Querying for variants in a gene takes between 0.002 and 3 seconds using memory only 10% of the size of the full representation.

Pandey, Prashant↗

Zero-crosstalk silicon photonic refractive index sensor with subwavelength gratings

Abstract Silicon photonic index sensors have received significant attention for label-free bio and gas-sensing applications, offering cost-effective and scalable solutions. Here, we introduce an ultra-compact silicon photonic refractive index sensor that leverages zero-crosstalk singularity responses enabled by subwavelength gratings. The subwavelength gratings are precisely engineered to achieve an anisotropic perturbation-led zero-crosstalk, resulting in a single transmission dip singularity in the spectrum that is independent of device length. The sensor is optimized for the transverse magnetic mode operation, where the subwavelength gratings are arranged perpendicular to the propagation direction to support a leaky-like mode and maximize the evanescent field interaction with the analyte space. Experimental results demonstrate a high wavelength sensitivity of − 410 nm/RIU and an intensity sensitivity of 395 dB/RIU, with a compact device footprint of approximately 82.8 μm 2 . Distinct from other resonant and interferometric sensors, our approach provides an FSR-free single-dip spectral response on a small device footprint, overcoming common challenges faced by traditional sensors, such as signal/phase ambiguity, sensitivity fading, limited detection range, and the necessity for large device footprints. This makes our sensor ideal for simplified intensity interrogation. The proposed sensor holds promise for a range of on-chip refractive index sensing applications, from gas to biochemical detection, representing a significant step towards efficient and miniaturized photonic sensing solutions. Graphical Abstract

Materials Science↗

Retrieval of the complex-valued refractive index of germanium near the M 4,5 absorption edge

The complex-valued index of refraction of germanium in the extreme ultraviolet (XUV) is measured by multiangle reflectance of synchrotron radiation. The resulting index of refraction is higher resolution than previously measured values. It reveals new structures attributed to transitions from the 3d-core orbitals to the $Σ^{c}_{5,2}$ and the $X^{c}_{5,2}$ conduction bands. Additionally, it is shown that the problem of total external reflection, which renders multi-angle reflectance measurements insensitive to the complex-valued refractive index at grazing incidence, can be overcome by employing measurements at angles of incidence away from the critical angle.

36 MATERIALS SCIENCE↗

An insight into statistical refractive index properties of cell internal structure via low-coherence statistical amplitude microscopy

Refractive index properties, especially at the nanoscale, have shown great potential in cancer diagnosis and screening. Due to the intrinsic complexity and weak refractive index fluctuation, the reconstruction of internal structures of a biological cell has been challenging. In this paper, we propose a simple and practical approach to derive the statistical properties of internal refractive index fluctuations within a biological cell with a new optical microscopy method – Low-coherence Statistical Amplitude Microscopy (SAM). We validated the capability of SAM to characterize the statistical properties of cell internal structures, which is described by numerical models of one-dimensional Gaussian random field. We demonstrated the potential of SAM in cancer detection with an animal model of intestinal carcinogenesis – multiple intestinal neoplasia mouse model. We showed that SAM-derived statistical properties of cell nuclear structures could detect the subtle changes that are otherwise undetectable by conventional cytopathology.

59 BASIC BIOLOGICAL SCIENCES↗

Hybrid interferometric diagnostic for the refractive index measurement across nearly discrete shock waves

The measurement of high temperature gas properties is key for characterizing high speed flows. Nearly discrete changes in density across shock waves, in particular, are difficult to resolve through traditional fringe-counting interferometric methods. Existing techniques for estimating large fringe jumps are either resolution limited or require specialized window configurations. In this Letter, we describe a unique hybrid interferometric technique that combines narrowband fringes for high resolution and broadband fringes as an absolute reference to measure changes in refractive index with a resolution of up to 7 × 10 −8 across nearly discrete index changes of up to 1.5 × 10 −4 . By capturing fringes with an ultrahigh-speed camera, the refractive index changes across discrete shock fronts can be estimated inside a shock tube with high accuracy and time resolution. First, a novel hybrid calibration method for tracking finite fringes is discussed. Next, this technique is used to measure the post-initial-shock refractive indices for Mach 2.7 to 4.2 flows (pressures from 90.4 to 228.4 kPa). Results are then compared with theoretical values showing agreement within 2%.

Wang, Gwendolyn T. (ORCID:000000016271893X)↗

AlSb as a material for high index contrast nanophotonics

High contrast materials, i.e., materials with a high refractive index and low optical loss, are of wide interest for nanophotonics and metasurface designs at optical and near infrared wavelengths. We explore aluminum antimonide (AlSb) as a high contrast nanophotonic material, using the design of high contrast gratings (HCGs) for low loss dielectric mirrors as an example. The high index of refraction and low absorption coefficient of AlSb in the visible wavelength range enable designs of HCGs that can be effectively optimized to form mirrors with 93.5% reflectivity at red visible wavelengths. We detail a co-sputtering synthesis method for AlSb films, and achieve our target high index of refraction of 3.5 for 635 nm light. We also find that the high sensitivity of AlSb oxidation requires specific handling procedures in developing deposition processes to yield a near zero absorption coefficient.

Bauser, Haley C.↗

China Green Low-Carbon City Index

The main purpose of the new China Green Low-Carbon City Index (CGLCI, or City Index) is to evaluate the status of green and low-carbon development for a large number of Chinese cities. Chinese cities are formulating plans and implementing programs to address national initiatives, especially the national low-carbon pilot program for 36 cities and six provinces. However, there is not yet an established framework for measuring, reporting, or evaluating low-carbon progress across Chinese cities, despite the development of a number of Chinese and international city indicator systems. The new China City Index highlights energy use and carbon emissions of Chinese cities, along with environmental and socio-economic indicators. We selected metrics (indicators) that have data available in China’s statistical system, are commonly used internationally, and reflect Chinese policy goals. We then benchmarked and ranked Chinese cities in terms of their status and progress, identified potential areas for improvement, and identified top-runners.

54 ENVIRONMENTAL SCIENCES↗

Building Fire Consequence Index at Sandia National Laboratories

The intent of the Building Fire Consequence Index (BFCI) at Sandia National Laboratories (SNL) is to provide a method to rank buildings based on the consequence of a fire in that building. This indexing tool will be used to determine the frequency a building's fire protection assessment (FPA) will be performed. Per DOE O 420.1C Chg. 1, Facility Safety, a FPA must be conducted annually (for facilities with a replacement value in excess of $100 million, facilities considered a high hazard, or those in which vital programs are involved), every three years (for remaining low and ordinary hazard facilities), or at a frequency with appropriate justification approved by the Depaitinent of Energy (DOE) head of field element. The BFCI provides a method for a graded approach utilizing a scoring criteria for various categories such as replacement plant value, building content value, hazards, mission dependency index, etc. when assigning FPA frequencies1.

42 ENGINEERING↗

China Green Low-Carbon City Index: Report on the Performance of 100+ Cities (2010-2015)

The main purpose of the new China Green Low-Carbon City Index (CGLCI, or City Index ) is to evaluate the status of green and low-carbon development for a large number of Chinese cities. Chinese cities are formulating plans and implementing programs to address national initiatives, especially the national low-carbon pilot program for 36 cities and six provinces. However, there is not yet an established framework for measuring, reporting, or evaluating low-carbon progress across Chinese cities, despite the development of a number of Chinese and international city indicator systems. The new China City Index highlights energy use and carbon emissions of Chinese cities, along with environmental and socio-economic indicators. We selected metrics (indicators) that have data available in China’s statistical system, are commonly used internationally, and reflect Chinese policy goals. (See Table ES-1.) We then benchmarked and ranked Chinese cities in terms of their status and progress, identified potential areas for improvement, and identified top-runners. By “low-carbon” we mean reducing emissions of carbon dioxide (CO 2 ) and methane (CH 4 ), with a focus on energy-related CO 2 . The term “carbon” is used as short-hand for these GHGs throughout the report. By “green” we recognize multiple environmental parameters related to urbanization and climate change: air quality, water use, solid waste, transport networks, and urban green space. In early 2017, China expanded its low-carbon pilot cities program, adding 45 more cities.

54 ENVIRONMENTAL SCIENCES↗

Auto Indexer for Percussive Hammers Final Report

Geothermal energy has been underutilized in the U.S., primarily due to the high cost of drilling in the harsh environments encountered during the development of geothermal resources. Drilling depths can approach 5,000 m with temperatures reaching 170 C. In situ geothermal fluids are up to ten times more saline than seawater and highly corrosive, and hard rock formations often exceed 240 MPa compressive strength. This combination of extreme conditions pushes the limits of most conventional drilling equipment. Furthermore, enhanced geothermal systems are expected to reach depths of 10,000 m and temperatures more than 300 °C. To address these drilling challenges, Sandia developed a proof-of-concept tool called the auto indexer under an annual operating plan task funded by the Geothermal Technologies Program (GTP) of the U.S. Department of Energy Geothermal Technologies Office. The auto indexer is a relatively simple, elastomer-free motor that was shown previously to be compatible with pneumatic hammers in bench-top testing. Pneumatic hammers can improve penetration rates and potentially reduce drilling costs when deployed in appropriate conditions. The current effort, also funded by DOE GTP, increased the technology readiness level of the auto indexer, producing a scaled prototype for drilling larger diameter boreholes using pneumatic hammers. The results presented herein include design details, modeling and simulation results, and testing results, as well as background on percussive hammers and downhole rotation.

15 GEOTHERMAL ENERGY↗

MCATK: Mesh and Material Indexing with Domain Decomposition [Slides]

Slides documenting some of the basics in how MCATK handles the mesh, mesh indexing, materials (IDs and Densities), material indexing, and domain decomposition indexing. These basics hold when using the hybrid parallelism; a full domain decomposition is one replica; a full domain replicated is when number of replicas equals the number of ranks; for the other cases of replicas then the decomposition is what is described here within each replica.

36 MATERIALS SCIENCE↗

High Refractive Index Adhesives for Laser Glass Cladding Applications (ABBREVIATED Report)

To eliminate parasitic light oscillations (amplified spontaneous emission (ASE)), high energy laser systems often utilize polymeric materials to adhere optically absorptive cladding materials to laser gain media (glass or crystal). Most of these polymeric optical adhesives are index matched to lower index gain media, and there was no capability to achieve refractive indices (RI) greater than 1.60 with low color, while also maintaining mechanical compliance to serve as adhesives for cladding applications. The completion of LDRD 23-FS-043 shows we can chemically develop novel suitable adhesive candidates with refractive indices above 1.64 at 532 nm while also exhibiting Shore A hardness between 50-90, with high optical clarity, low color, and minimal haze for films ~1-2 mm thick (84 %Transmission at 532 nm). This will enable us to begin mapping a process space to allow future customizable adhesive formulations for building a variety of laser systems with tunable refractive index matching for various gain and cladding media.

36 MATERIALS SCIENCE↗

A MODIS Photochemical Reflectance Index (PRI) as an Estimator of Isoprene Emissions in a Temperate Deciduous Forest

The quantification of isoprene and monoterpene emissions at the ecosystem level with available models and field measurements is not entirely satisfactory. Remote-sensing techniques can extend the spatial and temporal assessment of isoprenoid fluxes. Detecting the exchange of biogenic volatile organic compounds (BVOCs) using these techniques is, however, a very challenging goal. Recent evidence suggests that a simple remotely sensed index, the photochemical reflectance index (PRI), which is indicative of light-use efficiency, relative pigment levels and excess reducing power, is a good indirect estimator of foliar isoprenoid emissions. We tested the ability of PRI to assess isoprenoid fluxes in a temperate deciduous forest in central USA throughout the entire growing season and under moderate and extreme drought conditions. We then compared PRI time series calculated with MODIS bands to isoprene emissions measured with eddy covariance. MODIS PRI was correlated with isoprene emissions for most of the season, until emissions peaked. MODIS PRI was also able to detect the timing of the annual peak of emissions, even when it was advanced in response to drought conditions. PRI is thus a promising index to estimate isoprene emissions when it is complemented by information on potential emission. It may also be used to further improve models of isoprene emission under drought and other stress conditions. Direct estimation of isoprene emission by PRI is, however, limited, because PRI estimates LUE, and the relationship between LUE and isoprene emissions can be modified by severe stress conditions.

54 ENVIRONMENTAL SCIENCES↗

Refractive index sensing and surface-enhanced Raman spectroscopy using silver–gold layered bimetallic plasmonic crystals

Herein we describe the fabrication and characterization of Ag and Au bimetallic plasmonic crystals as a system that exhibits improved capabilities for quantitative, bulk refractive index (RI) sensing and surface-enhanced Raman spectroscopy (SERS) as compared to monometallic plasmonic crystals of similar form. The sensing optics, which are bimetallic plasmonic crystals consisting of sequential nanoscale layers of Ag coated by Au, are chemically stable and useful for quantitative, multispectral, refractive index and spectroscopic chemical sensing. Compared to previously reported homometallic devices, the results presented herein illustrate improvements in performance that stem from the distinctive plasmonic features and strong localized electric fields produced by the Ag and Au layers, which are optimized in terms of metal thickness and geometric features. Finite-difference time-domain (FDTD) simulations theoretically verify the nature of the multimode plasmonic resonances generated by the devices and allow for a better understanding of the enhancements in multispectral refractive index and SERS-based sensing. Taken together, these results demonstrate a robust and potentially useful new platform for chemical/spectroscopic sensing.

plasmonics↗

A NEW, LOW BRAKING INDEX FOR THE LMC PULSAR B0540–69

We report the results of a 16 month monitoring campaign using the Swift satellite of PSR B0540–69, a young pulsar in the Large Magellanic Cloud. Phase connection was maintained throughout the campaign so that a reliable ephemeris could be determined, and the length of the campaign is adequate to accurately determine the spin frequency ν and its first and second derivatives. The braking index n is 0.031 ± 0.013 (90% confidence), a value much lower than previously reported for B0540–69 and almost all other young pulsars. We use data from the extensive monitoring campaign with Rossi X-ray Timing Explorer to show that timing noise is unlikely to significantly affect the measurement. This is the first measurement of the braking index in the pulsar's recently discovered high spin-down state. We discuss possible mechanisms for producing the low braking index.

79 ASTRONOMY AND ASTROPHYSICS↗