At least 433 records · Page 24

Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards

The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system must also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer aerodynamic diameter were injected into the environmental chamber and drawn through the conditioning system, which included a filter to capture droplets that passed through the conditioner. The droplets were tagged with a fluorescent dye which allowed quantification of droplet deposition on each component of the system. The tests demonstrated the required reductions in temperature and moisture, with no condensation forming when heat tracing was added on the upstream end of the sample conditioner. Additionally, tests indicated that the system, operating at several flow rates and in both vertical and horizontal orientations, delivers nearly all of the sampled particles for analysis. Typical aerosol penetration values were between 98 and 99%. PNNL, Bechtel National Inc., and the instrument vendor are working to implement the sample conditioner into the air monitoring systems used for the melter off-gas exhaust streams. Similar technology may be useful for processes in other facilities with air exhaust streams with elevated temperature and/or humidity.

sample conditioning↗

Analysis and improvement of detection accuracy for a wireless motion sensing system using integrated coil component

Integration of the exciting coil and the pick-up coil array for the wireless magnetic motion sensing system has been investigated to clear the limitation of the system arrangement. From the comparison of the integrated-type and the sandwich-type, which was proposed by our previous study, regardless of the lower signal-to-noise ratio of the integrated-type than that of the sandwich-type a repeatable detection accuracy of around 1 mm is obtained at the distance of 120 mm from the pick-up coil array (sandwich-type: up to 140 mm). A different tendency of the detection errors in detection was also observed. In spite of different tendency, the cause of the errors has been clarified. The impedance change of the exciting coil due to a resonance of the LC marker perturbs strength of the magnetic field which is used for marker excitation. However, the errors are able to compensate to the actual positions and orientations of the marker by using compensatory method which was already established.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ISPM experiment for spectral, composition and anistropy measurements of charged particles at low energie

The Heliosphere Instrument for Spectral, Composition, and Anisotropy at Low Energies (HI-SCALE) designed to measure interplanetary ions and electrons is described. Ions and electrons are detected by five separate solid-state detector telescopes oriented to give complete pitch angle coverage from the spinning spacecraft. Ion elemental abundances are determined by a telescope using a thin front detector element in a three-element telescope. Experiment operation is controlled by a microprocessor-based data system. Inflight calibration is provided by radioactive sources mounted on closable telescope covers. Ion and electron spectral information is determined using broad-energy-range rate channels, and a pulse-height analyzer for more detailed spectra. The instrument weighs 5.775 kg and uses 4.0 W power.

Lanzerotti, L. J.↗

Highlights of NASA’s Orbital Debris Program Office In Situ and Laboratory Measurements

NASA’s Orbital Debris Program Office (ODPO) maintains various returned spacecraft materials, capabilities, and facilities used for in situ and laboratory measurements that directly support orbital debris environmental models. In situ measurements include the analysis of exposed and returned hardware surfaces. These surfaces serve as passive sensors for the small-sized micrometeoroid and orbital debris (MMOD) flux below the sensitivity of ground-based radar and optical sensors. Various instruments and techniques are used to determine the size and depth of selected impact features, and – if feasible – the composition of the projectile material. Analysis of the impactor residues enables the differentiation of MM and OD for debris below 1 mm to support modeling the OD environment. In addition, projectiles identified as OD can be further differentiated in low-, medium-, and high- density impactors based on chemical analyses. In addition to in situ measurements, the ODPO has also worked in collaboration with the U.S. Space Force Space Systems Command (formerly the U.S. Air Force Space and Missile Systems Center), the Aerospace Corporation, and the University of Florida on a laboratory-based hypervelocity impact test, DebriSat, conducted at the Air Force Arnold Engineering Development Complex in 2014. The resulting data from this impact test series are being analyzed to assess the fragments’ sizes/masses, materials/densities, shapes, and other parameters of interest. The DebriSat project provides the data needed to update NASA’s breakup models and size estimation models using the simulated orbital breakup of a modern, low Earth orbit spacecraft. Ultimately, over 200,000 fragments from this impact test will be stored at NASA Johnson Space Center (JSC) and further analyzed by the ODPO. This project will also use machine learning techniques to infer physical parameters of fragments embedded in the soft-catch foam used in the impact experiment. Applied to X-ray imagery of the foam panels, these techniques promise to minimize human-in-the-loop processes for fragment extraction and physical characterization. A brief overview of this project and data collected will be presented. Lastly, the ODPO provides various capabilities hosted at NASA JSC for optical inspections and measurements using a variety of techniques and scientific instrumentation to support both in situ and laboratory measurements. The ODPO’s Optical Measurement Center (OMC) is an advanced facility for photometric and spectroscopic laboratory measurements of targets, including fragments from the DebriSat project. The OMC simulates telescopic observations by using space-like illumination conditions and source-target-sensor orientation techniques. Additionally, the OMC is uniquely equipped to acquire pseudo-bidirectional reflectance distribution data for broadband photometric measurements, thus removing aspect angle dependencies that can affect target size estimates using the optical size estimation model. Narrow-band surface material characterization using spectroscopic instrumentation gives insight into how the albedo parameter – also important in the optical size estimation model – may vary depending on the state of the material. The OMC also performs simulations of photometric measurements using optical ray-tracing software to model the OMC optical throughput. In addition to the OMC, the ODPO houses a start-of-the-art Fragment Analysis Facility that uses multiple microscopic inspection instruments to support in situ measurements and material characterization. An overview of both facilities will be highlighted in this paper.

Orbital Debris↗

Highlights of NASA’s Orbital Debris Program Office In Situ and Laboratory Measurements

NASA’s Orbital Debris Program Office (ODPO) maintains various returned spacecraft materials, capabilities, and facilities used for in situ and laboratory measurements that directly support orbital debris environmental models. In situ measurements include the analysis of exposed and returned hardware surfaces. These surfaces serve as passive sensors for the small-sized micrometeoroid and orbital debris (MMOD) flux below the sensitivity of ground-based radar and optical sensors. Various instruments and techniques are used to determine the size and depth of selected impact features, and – if feasible – the composition of the projectile material. Analysis of the impactor residues enables the differentiation of MM and OD for debris below 1 mm to support modeling the OD environment. In addition, projectiles identified as OD can be further differentiated in low-, medium-, and high- density impactors based on chemical analyses. In addition to in situ measurements, the ODPO has also worked in collaboration with the U.S. Space Force Space Systems Command (formerly the U.S. Air Force Space and Missile Systems Center), the Aerospace Corporation, and the University of Florida on a laboratory-based hypervelocity impact test, DebriSat, conducted at the Air Force Arnold Engineering Development Complex in 2014. The resulting data from this impact test series are being analyzed to assess the fragments’ sizes/masses, materials/densities, shapes, and other parameters of interest. The DebriSat project provides the data needed to update NASA’s breakup models and size estimation models using the simulated orbital breakup of a modern, low Earth orbit spacecraft. Ultimately, over 200,000 fragments from this impact test will be stored at NASA Johnson Space Center (JSC) and further analyzed by the ODPO. This project will also use machine learning techniques to infer physical parameters of fragments embedded in the soft-catch foam used in the impact experiment. Applied to X-ray imagery of the foam panels, these techniques promise to minimize human-in-the-loop processes for fragment extraction and physical characterization. A brief overview of this project and data collected will be presented. Lastly, the ODPO provides various capabilities hosted at NASA JSC for optical inspections and measurements using a variety of techniques and scientific instrumentation to support both in situ and laboratory measurements. The ODPO’s Optical Measurement Center (OMC) is an advanced facility for photometric and spectroscopic laboratory measurements of targets, including fragments from the DebriSat project. The OMC simulates telescopic observations by using space-like illumination conditions and source-target-sensor orientation techniques. Additionally, the OMC is uniquely equipped to acquire pseudo-bidirectional reflectance distribution data for broadband photometric measurements, thus removing aspect angle dependencies that can affect target size estimates using the optical size estimation model. Narrow-band surface material characterization using spectroscopic instrumentation gives insight into how the albedo parameter – also important in the optical size estimation model – may vary depending on the state of the material. The OMC also performs simulations of photometric measurements using optical ray-tracing software to model the OMC optical throughput. In addition to the OMC, the ODPO houses a start-of-the-art Fragment Analysis Facility that uses multiple microscopic inspection instruments to support in situ measurements and material characterization. An overview of both facilities will be highlighted in this paper.

Orbital Debris↗

Microscopic diamond solid-immersion-lenses fabricated around single defect centers by focused ion beam milling

Recent efforts to define microscopic solid-immersion-lenses (SIL) by focused ion beam milling into diamond substrates that are registered to a preselected single photon emitter are summarized. We show how we determine the position of a single emitter with at least 100 nm lateral and 500 nm axial accuracy, and how the milling procedure is optimized. The characteristics of a single emitter, a Nitrogen Vacancy (NV) center in diamond, are measured before and after producing the SIL and compared with each other. A count rate of 1.0 × 10{sup 6} counts/s is achieved with a [111] oriented NV center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rework Recipe Development, Analysis and Results of Select 9-Cell Cavities for LCLS-II

The SLAC National Accelerator Laboratory is currently constructing a major upgrade to its accelerator, the Linac Coherent Light Source II (LCLS-II). Several Department of Energy laboratories, including the Thomas Jefferson National Accelerator Facility (JLab) and Fermi National Accelerator Laboratory (FNAL), are collaborating in this project. The cryomodules for this project each consist of eight 1.3-GHz cavities produced by two vendors, Research Instruments GmbH in Germany (RI*) and Ettore Zanon S.p.a. in Italy (EZ*), using niobium cell material from Tokyo Denkai Co., Ltd. (TD) and Ningxia Orient Tantalum Industry Co., Ltd. (OTIC/NX)). During the initial production run, cavity performance from one of the vendors (Vendor A) was far below expectation. All the cavities had low Q0, later attributed to minimal EP as well as high-flux-trapping NX material, early quench behaviour below 18 MV/m, with many having Q0 roll-off at 12-16 MV/m. Production was stopped multiple times over the following 6 months, with test batches of cavities being made to ascertain the root cause of the problem. The final root cause of the problem was found to be inappropriate grinding of the RF surface prior to welding which left normal conducting inclusions in the surface. In addition, most cavities showed internal and external weld spatter which required post weld grinding and a very rough surface from operating the electropolishing machine in an etching rather than polishing regime. All issues have been corrected on new cavities and rework is underway on the originally effected cavities.

Macha, Kurt M.↗

System design consideration for the Nimbus-G observatory mission

The objectives of the Nimbus-G mission are to study air pollution, ocean parameters, and weather and climate on a global scale. The observations required to meet these objectives include nadir viewing and scanning, and limb viewing and scaling techniques. Each of these approaches requires that the spacecraft provide a sensor mounting surface that maintains a fixed orientation relative to the nadir and the orbit track and that the orientation of the orbit plane remain constant with respect to the sun for maximum space cooler efficiency. The tradeoffs necessary to satisfy the conflicting instrument payload requirements within the constraints placed on the Nimbus design are discussed, along with the modifications necessary to meet the unique needs of the instrument complement.

Hogan, G. D.↗

Flight evaluation of a precision landing task for a powered-lift STOL aircraft

A flight research experiment was conducted with the NASA-Ames Research Center's Quiet Short-Haul Research Aircraft to determine the factors which influence the touchdown distribution for a powered-lift STOL aircraft. The pilots were given two tasks for each of a series of precision approaches flown using a microwave landing system (MLS) in simulated instrument meteorological conditions. They flew the aircraft, with forward vision obscured by a screen, to a 100-ft decision height using a flightpath-oriented, color electronic display and one of four levels of control augmentation. Approaches were flown along a nominal 6 deg glidepath, as well as to calibrated offsets at the decision height to establish a variety of initial conditions for the landing task. The screen was removed at the decision height and the pilot was briefed to land in a 200 foot touchdown zone of the STOLport with a sink rate less than 5 ft/sec. Statistical performance envelopes and pilot ratings are used to describe the results of this experiment. The data generated are expected to be useful for establishing STOL aircraft operating requirements and STOL MLS approach criteria.

Watson, D. M.↗

Reflectance spectra from eutrophic Mono Lake California, measured with the Airborne Visible and Infrared Imaging Spectrometer (AVIRIS)

An AVIRIS image was obtained for Mono Lake, California, on May 26, 1989, a day with excellent visibility. Atmospherically-corrected reflectance spectra derived from the image indicate a spectral signature for chlorophyll a, the dominant photosynthetic pigment in the phytoplankton of the lake. Chlorophyll a concentrations in the lake were about 22 mg/cu m, and the upwelling radiance was low with a peak reflectance at about 570 nm of about 5 percent. Coherent noise appeared in the image as regular variations of 0.1 to 0.2 microwatts/sq cm per str oriented diagonally to the flight line. A simple ratio of two spectral bands removed the conspicuous undulations, but modifications of the shielding within the instrument are needed to improve the signal especially over dark targets such as lakes.

Melack, John M.↗

Global Ultraviolet Imaging Processing for the GGS Polar Visible Imaging System (VIS)

The Visible Imaging System (VIS) on Polar spacecraft of the NASA Goddard Space Flight Center was launched into orbit about Earth on February 24, 1996. Since shortly after launch, the Earth Camera subsystem of the VIS has been operated nearly continuously to acquire far ultraviolet, global images of Earth and its northern and southern auroral ovals. The only exceptions to this continuous imaging occurred for approximately 10 days at the times of the Polar spacecraft re-orientation maneuvers in October, 1996 and April, 1997. Since launch, approximately 525,000 images have been acquired with the VIS Earth Camera. The VIS instrument operational health continues to be excellent. Since launch, all systems have operated nominally with all voltages, currents, and temperatures remaining at nominal values. In addition, the sensitivity of the Earth Camera to ultraviolet light has remained constant throughout the operation period. Revised flight software was uploaded to the VIS in order to compensate for the spacecraft wobble. This is accomplished by electronic shuttering of the sensor in synchronization with the 6-second period of the wobble, thus recovering the original spatial resolution obtainable with the VIS Earth Camera. In addition, software patches were uploaded to make the VIS immune to signal dropouts that occur in the sliprings of the despun platform mechanism. These changes have worked very well. The VIS and in particular the VIS Earth Camera is fully operational and will continue to acquire global auroral images as the sun progresses toward solar maximum conditions after the turn of the century.

Frank, L. A.↗

Plasma Sheath Behavior of the ProSEDS Delta II

The Propulsive Small Expendable Deployer System (ProSEDS) mission is a demonstration of the orbit lowering capabilities of an electrodynamic tether. The system is sequenced through various electrical modes, involving both open circuit and closed circuit configurations, so that the performance capabilities of the system can be studied. Ionospheric electrons are collected on the upper end of the bare tether, conducted through the tether, and returned to the ionosphere at the lower end (Delta I1 2nd stage) via the operation of a Hollow Cathode Plasma Contactor (HCPC). The working gas of the HCPC is xenon. Environmental plasma measurements and sheath potential are obtained from the Differential Ion Flux Probe w/Mass Analysis (DIFPM) and Langmuir Probe and Spacecraft Potential (LPSP) instruments. Each instrument has three sensors symmetrically placed about the strut section of the Delta 2nd stage. A magnetometer is also included in the ProSEDS instrumentation suite. An initial analysis of the rocket stage sheath behavior as a function of ProSEDS configuration (open or closed circuit), ambient ionospheric density, orientation to velocity vector (ram-wake influence), and magnetic field orientation is presented. An initial assessment on how well the plasma contactor grounded the rocket stage is also presented.

Wright, K. H.↗

The Effectiveness of Various Attitude Indicator Display Sizes and Extended Horizon Lines on Attitude Maintenance in a Part-Task Simulation

Spatial disorientation (SD) is a constant contributing factor to the rate of fatal aviation accidents. SD occurs as a result of perceptual errors that can be attributed in part to the inefficient presentation of synthetic orientation cues via the attitude indicator when external visual conditions are poor. Improvements in the design of the attitude indicator may help to eliminate instrumentation as a factor in the onset of SD. The goal of the present study was to explore several display concepts that may contribute to an improved attitude display. Specifically, the effectiveness of various display sizes, some that are used in current and some that are anticipated in future attitude displays that may incorporate Synthetic Vision Systems (SVS) concepts, was assessed. In addition, a concept known as an extended horizon line or Malcolm Horizon (MH) was applied and evaluated. Paired with the MH, the novel concept of a fixed reference line representing the central horizontal plane of the aircraft was also tested. Subjects performance on an attitude control task and secondary math workload task was measured across the various display sizes and conditions. The results, with regard to display size, confirmed the bigger is better concept, yielding better performance with the larger display sizes. A clear and significant improvement in attitude task performance was found with the addition of the extended horizon line. The extended or MH seemed to equalize attitude performance across display sizes, even for a central or foveal display as small as three inches in width.

Comstock, J. Raymond, Jr.↗

Transient Plume Model Testing Using LADEE Spacecraft Attitude Control System Operations

The Lunar Atmosphere Dust Environment Explorer (LADEE) spacecraft is being designed for a mission featuring low altitude orbits of the Moon to take relevant ambient measurements before that environment becomes altered by future exploration activities. Instruments include a neutral mass spectrometer capable of measuring ambient species density levels below 100 molecules/cu cm. Coincidentally, with a favorable combination of spacecraft orientations, it is also possible to measure plume gases from LADEE attitude control system thruster operations as they are reflected from the daytime lunar surface and subsequently intercepted by the spacecraft as it orbits overhead. Under such circumstances, it may be possible to test a variety of properties and assumptions associated with various transient plume models or to infer certain aspects regarding lunar surface properties.

Woronowicz, M. S.↗

Ground Operations Autonomous Control and Integrated Health Management

An intelligent autonomous control capability has been developed and is currently being validated in ground cryogenic fluid management operations. The capability embodies a physical architecture consistent with typical launch infrastructure and control systems, augmented by a higher level autonomous control (AC) system enabled to make knowledge-based decisions. The AC system is supported by an integrated system health management (ISHM) capability that detects anomalies, diagnoses causes, determines effects, and could predict future anomalies. AC is implemented using the concept of programmed sequences that could be considered to be building blocks of more generic mission plans. A sequence is a series of steps, and each executes actions once conditions for the step are met (e.g. desired temperatures or fluid state are achieved). For autonomous capability, conditions must consider also health management outcomes, as they will determine whether or not an action is executed, or how an action may be executed, or if an alternative action is executed instead. Aside from health, higher level objectives can also drive how a mission is carried out. The capability was developed using the G2 software environment (www.gensym.com) augmented by a NASA Toolkit that significantly shortens time to deployment. G2 is a commercial product to develop intelligent applications. It is fully object oriented. The core of the capability is a Domain Model of the system where all elements of the system are represented as objects (sensors, instruments, components, pipes, etc.). Reasoning and decision making can be done with all elements in the domain model. The toolkit also enables implementation of failure modes and effects analysis (FMEA), which are represented as root cause trees. FMEA's are programmed graphically, they are reusable, as they address generic FMEA referring to classes of subsystems or objects and their functional relationships. User interfaces for integrated awareness by operators have been created.

Figueroa, Fernando↗

TH-CD-BRA-07: MRI-Linac Dosimetry: Parameters That Change in a Magnetic Field

Purpose: In MRI-linac integrated systems, the presence of the magnetic (B-)field has a large impact of the dose-distribution and the dose-responses of detectors; yet established protocols and previous experience may lead to assumptions about the commissioning process that are no longer valid. This study quantifies parameters that change when performing dosimetry with an MRI-linac including beam quality specifiers and the effective-point-of-measurement (EPOM) of ionization chambers. Methods: We used the Geant4 Monte Carlo code for this work with physics parameters that pass the Fano cavity test to within 0.1% for the simulated conditions with and without a 1.5 T B-field. A point source model with the energy distribution of an MRI-linac beam was used with and without the B-field to calculate the beam quality specifiers %dd(10)× and TPR{sup 20}{sub 10}, the variation of chamber response with orientation and the how the B-field affects the EPOM of ionization chambers by comparing depth-dose curves calculated in water to those generated by a model PTW30013 Farmer chamber. Results: The %dd(10)× changes by over 2% in the presence of the B-field while the TPR{sup 20}{sub 10} is unaffected. Ionization chamber dose-response is known to depend on the orientation w.r.t. the B-field, but two alternative perpendicular orientations (anti-parallel to each other) also differ in dose-response by over 1%. The B-field shifts the EPOM downstream (closer to the chamber center) but it is also shifted laterally by 0.27 times the chamber’s cavity radius. Conclusion: The EPOM is affected by the B-field and it even shifts laterally. The relationship between %dd(10)× and the Spencer-Attix stopping powers is also changed. Care must be taken when using chambers perpendicular to the field as the dose-response changes depending on which perpendicular orientation is used. All of these effects must be considered when performing dosimetry in B-fields and should be accounted for in future dosimetry protocols. This project was partially funded by Elekta Ltd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Joist Masonry Moisture Content Monitoring

BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring House - Lawrence, MA 01840 This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the building (which have a variety of orientations, exposures, and masonry wall types) were monitored for wood MCs at the embedded joist ends and for temperatures and RHs within the joist pocket. Indoor and outdoor conditions were also recorded. Results were collected for 28 months (December 2012-April 2015). One limitation was that the renovation was still ongoing; limited wintertime construction heating and no permanent occupancy were factors. Much of the building experienced cold interior temperatures (e.g., construction heating) during the winters. These were not typical interior heating set points. Because the building was essentially unoccupied, no significant interior moisture was generated. These boundary conditions are not normal service conditions. Overall, the RHs and MCs measured in joist pockets were higher than recommended for longterm durability. Many of the joist pockets had sustained conditions of 100% RH, and many wood MCs were in the 25%-35% range for extended periods. Typical guidance includes: (1) MCs lower than 20% are safe, and (2) decay fungi become active at MCs higher than 28%. ASHRAE xi 160 analysis showed that high RH levels coincided with temperatures that were high enough to support mold growth for most of the monitoring period (60%-70% of the hours) in most joists. However, no damage was seen at the joist ends when the instrumentation was installed or when a joist end sample was removed. This suggests that dense, old-growth framing might be able to survive these MCs without damage. Orientation has a significant effect on RH and MC levels: solar heating and drying kept all southfacing joist MCs well within the safe range. The east and west orientations had mixed results: some were in the safe range, but others exceeded the 20% MC level. The north side joists consistently had the highest MCs. Almost all the joists showed seasonal rises and falls; MC and RH conditions were higher during the summer and lower during the winter. This indicates the temperature gradient caused moisture to be driven inward during the summer. MC plots with driving rain showed no discernable correlations. In the parts of the building that had significant wintertime heating, many joists showed a drop in MC that coincided with the addition of heat, even after insulation and air sealing were installed. The joist ends showed a repeated pattern of MC measurements at their upper and lower ends. The lower joist end was consistently wetter than the upper joist end, which can be attributed to contact with the masonry pocket, gravity drainage of bulk water to the bottom of the pocket, greater drying at the top of the beam or deeper embedment at the bottom of the beam, and a larger air pocket at the top of the beam. The north-facing insulated and uninsulated joist ends were compared; a significant or consistent MC or RH difference was not seen between these cases. All three joist pockets essentially remained at a constant 100% RH.

Array↗