Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A realistic guide misalignment model for the Second Target Station instruments at the Spallation Neutron Source

The Second Target Station (STS) at the Spallation Neutron Source, including a suite of initial instrument concepts, are being designed in Oak Ridge. The moderator size at STS is significantly smaller than that of the First Target Station, making the guide misalignment a more prominent concern. Here a realistic misalignment model based on Monte Carlo neutron ray tracing simulation was developed to evaluate the impacts of both the random misalignment and floor settlement on the performance of a toy model of 150 m straight guide system, and MENUS, an STS instrument concept with a typical guide design of two opposing Montel mirrors. The study shows that longer instruments, and instruments with complex curved mirrors/guides are sensitive to significant performance penalties due to misalignments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unpacking the drivers of diurnal dynamics of sun-induced chlorophyll fluorescence (SIF): Canopy structure, plant physiology, instrument configuration and retrieval methods

Sun-induced chlorophyll fluorescence (SIF) from spaceborne sensors is a promising tool for global carbon cycle monitoring, but its application is constrained by insufficient understanding of the drivers underlying diurnal SIF dynamics. SIF measurements from ground-based towers can reveal diurnal SIF dynamics across biomes and environmental conditions; however, meaningful interpretation of diurnal variations requires disentangling impacts from canopy structure, plant physiology, instrument configuration and retrieval methods, which often interact with and confound each other. This study aims to unpack these drivers using 1) concurrent ground and airborne canopy-scale and leaf-scale measurements at a corn field, 2) a mechanistic SIF model that explicitly considers the dynamics of photochemistry (via the fraction of open photosystem II reaction centers, qL) and photoprotection (via nonphotochemical quenching, NPQ) as well as their interactive dependence on the sub-canopy light environment, and 3) cross-comparison of SIF instrument configurations and retrieval methods. We found that crop row orientations and sun angles can introduce a distinctive midday dip in SIF in absence of stress, due to a midday drop of absorbed photosynthetically active radiation (APAR) when crop rows are north-south oriented. Canopy structure caused distinctive responses in both qL and NPQ at different positions within the vertical canopy that collectively influenced fluorescence quantum yield (Φ F ) at the leaf scale. Once integrated at the canopy scale, diurnal dynamics of both APAR and canopy escape probability (ε) are critical for accurately shaping diurnal SIF variations. While leaf-level qL and NPQ exhibited strong diurnal dynamics, their influence was attenuated at the canopy scale due to opposing effects on SIF at different canopy layers. Furthermore, different system configurations (i.e., bi-hemispherical vs. hemispherical-conical) and retrieval methods can bias the SIF magnitude and distort its diurnal shapes, therefore confounding the interpretation of inherent strength and dynamics of SIF emission. Our findings demonstrate the importance of crop row structures, interactive variations in canopy structure and plant physiology, instrument configuration, and retrieval method in shaping the measured dynamics of diurnal SIF. This study highlights the necessity to account for these factors to accurately interpret satellite SIF, and informs future synthesis work with different SIF instrumentation and retrieval methods across sites.

59 BASIC BIOLOGICAL SCIENCES↗

Bootstrap estimation of the effect of instrument response function uncertainty on the reconstruction of fusion neutron sources

Neutron imagers are important diagnostics for the inertial confinement fusion implosions at the National Ignition Facility. They provide two- and three-dimensional reconstructions of the neutron source shape that are key indicators of the overall performance. To interpret the shape results properly, it is critical to estimate the uncertainty in those reconstructions. There are two main sources of uncertainties: limited neutron statistics, leading to random errors in the reconstructed images, and incomplete knowledge of the instrument response function (the pinhole-dependent point spread function). While the statistical errors dominate the uncertainty for lower yield deuterium-tritium (DT) shots, errors due to the instrument response function dominate the uncertainty for DT yields on the order of 10 16 neutrons or higher. In this work, a bootstrapping method estimates the uncertainty in a reconstructed image due to the incomplete knowledge of the instrument response function. The main reconstruction is created from the fixed collection of pinhole images that are best aligned with the neutron source. Additional reconstructions are then built using subsets of that collection of images. Variations in the shapes of these additional reconstructions originate solely from uncertainties in the instrument response function, allowing us to use them to provide an additional systematic uncertainty estimate.

47 OTHER INSTRUMENTATION↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

The Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D) at the Spallation Neutron Source (invited)

The Oak Ridge National Laboratory is planning to build the Second Target Station (STS) at the Spallation Neutron Source (SNS). STS will host a suite of novel instruments that complement the First Target Station’s beamline capabilities by offering an increased flux for cold neutrons and a broader wavelength bandwidth. A novel neutron imaging beamline, named the Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D), is among the first eight instruments that will be commissioned at STS as part of the construction project. CUPI 2 D is designed for a broad range of neutron imaging scientific applications, such as energy storage and conversion (batteries and fuel cells), materials science and engineering (additive manufacturing, superalloys, and archaeometry), nuclear materials (novel cladding materials, nuclear fuel, and moderators), cementitious materials, biology/medical/dental applications (regenerative medicine and cancer), and life sciences (plant–soil interactions and nutrient dynamics). The innovation of this instrument lies in the utilization of a high flux of wavelength-separated cold neutrons to perform real time in situ neutron grating interferometry and Bragg edge imaging—with a wavelength resolution of δλ/λ ≈ 0.3%—simultaneously when required, across a broad range of length and time scales. This manuscript briefly describes the science enabled at CUPI 2 D based on its unique capabilities. The preliminary beamline performance, a design concept, and future development requirements are also presented.

47 OTHER INSTRUMENTATION↗

Algorithm-Driven Advances for Scientific CT Instruments: From model-based to deep learning-based approaches

Multiscale 3D characterization is widely used by materials scientists to further their understanding of the relationships between microscopic structure and macroscopic function. Scientific computed tomography (SCT) instruments are one of the most popular choices for 3D nondestructive characterization of materials at length scales ranging from the angstrom scale to the micron scale. These instruments typically have a source of radiation (such as electrons, X-rays, or neutrons) that interacts with the sample to be studied and a detector assembly to capture the result of this interaction (see Figure 1 ). A collection of such high-resolution measurements is made by reorienting the sample, which is mounted on a specially designed stage/holder after which reconstruction algorithms are used to produce the final 3D volume of interest. The specific choice of which instrument to use depends on the desired resolution and properties of the materials being imaged. Additionally, the end goal of SCT scans includes determining the morphology, chemical composition, or dynamic behavior of materials when subjected to external stimuli. In summary, SCT instruments are powerful tools that enable 3D characterization across multiple length scales and play a critical role in furthering the understanding of the structure–function relationships of different materials.

42 ENGINEERING↗

Nephelometer Instrument Handbook

The Integrating Nephelometer (Figure 1) is an instrument that measures aerosol light scattering. It measures aerosol optical scattering properties by detecting (with a wide angular integration – from 7 to 170°) the light scattered by the aerosol and subtracting the light scattered by the carrier gas, the instrument walls and the background noise in the detector (zeroing). Zeroing is typically performed for 5 minutes every day at midnight UTC. The scattered light is split into red (700 nm), green (550 nm), and blue (450 nm) wavelengths and captured by three photomultiplier tubes. The instrument can measure total scatter as well as backscatter only (from 90 to 170°) (Heintzenberg and Charlson 1996; Anderson et al. 1996; Anderson and Ogren 1998; TSI 3563 2015) At ARM (Atmospheric Radiation Measurement), two identical Nephelometers are usually run in series with a sample relative humidity (RH) conditioner between them. This is possible because Nephelometer sampling is non-destructive and the sample can be passed on to another instrument. The sample RH conditioner scans through multiple RH values in cycles, treating the sample. This kind of setup allows to study how aerosol particles’ light scattering properties are affected by humidification (Anderson et al. 1996). For historical reasons, the two Nephelometers in this setup are labeled “wet” and “dry”, with the “dry” Nephelometer usually being the one before the conditioner and sampling ambient air (the names are switched for the MAOS measurement site due to the high RH of the ambient air).

47 OTHER INSTRUMENTATION↗

Second Target Station Instrument Systems Research and Development Plan

This document describes the research and development (R&D) plan for Second Target Station (STS) instruments and bunker. The R&D program at STS seeks to mitigate risk and develop new technologies that will enhance performance for deployment on the eight instruments that are part of the STS project. Currently, STS is actively developing six of the eight instruments. This document is expected to be revised as the R&D program progresses and activities begin on the remaining two instruments (VERDI and EXPANSE).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Simulations for the VENUS Neutron Imaging Instrument

The VENUS Neutron Imaging instrument at the Spallation Neutron Source has gone through a multitude of optical design changes since its original conception. The goal of this report is to quantify the performance of the most recent optical design and provide insight into potential improvements to this design as needed to ensure optimal performance of the instrument. The results will come in the form of a refined and well developed simulation that provides as best a representation of the performance of the instrument as reasonably achievable. This simulation will be available in a repository alongside relevant simulation output needed to inform any future decisions on the design of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of ARM tethered-balloon system instrumentation for supercooled liquid water and distributed temperature sensing in mixed-phase Arctic clouds

A tethered-balloon system (TBS) has been developed and is being operated by Sandia National Laboratories (SNL) on behalf of the U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) User Facility in order to collect in situ atmospheric measurements within mixed-phase Arctic clouds. Periodic tethered-balloon flights have been conducted since 2015 within restricted airspace at ARM's Advanced Mobile Facility 3 (AMF3) in Oliktok Point, Alaska, as part of the AALCO (Aerial Assessment of Liquid in Clouds at Oliktok), ERASMUS (Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems), and POPEYE (Profiling at Oliktok Point to Enhance YOPP Experiments) field campaigns. The tethered-balloon system uses helium-filled 34 m 3 helikites and 79 and 104 m 3 aerostats to suspend instrumentation that is used to measure aerosol particle size distributions, temperature, horizontal wind, pressure, relative humidity, turbulence, and cloud particle properties and to calibrate ground-based remote sensing instruments. Supercooled liquid water content (SLWC) sondes using the vibrating-wire principle, developed by Anasphere Inc., were operated at Oliktok Point at multiple altitudes on the TBS within mixed-hase clouds for over 200 h. Sonde-collected SLWC data were compared with liquid water content derived from a microwave radiometer, Ka-band ARM zenith radar, and ceilometer at the AMF3, as well as liquid water content derived from AMF3 radiosonde flights. The in situ data collected by the Anasphere sensors were also compared with data collected simultaneously by an alternative SLWC sensor developed at the University of Reading, UK; both vibrating-wire instruments were typically observed to shed their ice quickly upon exiting the cloud or reaching maximum ice loading. Temperature sensing measurements distributed with fiber optic tethered balloons were also compared with AMF3 radiosonde temperature measurements. Combined, the results indicate that TBS-distributed temperature sensing and supercooled liquid water measurements are in reasonably good agreement with remote sensing and radiosonde-based measurements of both properties. From these measurements and sensor evaluations, tethered-balloon flights are shown to offer an effective method of collecting data to inform and constrain numerical models, calibrate and validate remote sensing instruments, and characterize the flight environment of unmanned aircraft, circumventing the difficulties of in-cloud unmanned aircraft flights such as limited flight time and in-flight icing.

47 OTHER INSTRUMENTATION↗

Simulations of the collection of mesospheric dust particles with a rocket instrument

We investigate the collection of dust particles in the mesosphere with the MESS (MEteoric Smoke Sampler) instrument that is designed to fly on a sounding rocket. We assume that the ice particles that form in the polar mesosphere between 80 and 85 km altitude in summer contain meteoric smoke particles; and these should be collected with MESS. The instrument consists of a collection device with an opening and closure mechanism, as well as an attached conic funnel which increases the sampling area in comparison to the collection area. Dust particles are collected either directly after passing through the instrument or indirectly after colliding with and fragmenting on the funnel wall. We calculate the dust and fragment trajectories in the detector to determine the collection efficiency for different particle sizes, rocket velocities, and heights, and we find the final velocities and the temperatures of the particles. The considered design has a sampling area of 62.78 mm diameter and a collection area of 20 mm diameter. For the conditions at the rocket launch site in Andøya, Norway, we estimate the collection of meteoric smoke particles contained in the ice particles to be ~10 12 –10 14 amu mm –2 . The estimated temperatures suggest that the composition of these smoke particles is not affected by the collection. Our calculations also show that keeping the instrument open above 85 km altitude increases the amount of small smoke particles that are directly collected. The directly collected smoke particles are heated as they decelerate, which can affect their composition.

47 OTHER INSTRUMENTATION↗

OMPS Limb Profiler Instrument Performance Assessment

Following the successful launch of the Ozone Mapping and Profiler Suite (OMPS) aboard the Suomi National Polar-orbiting Partnership (SNPP) spacecraft, the NASA OMPS Limb team began an evaluation of instrument and data product performance. The focus of this paper is the instrument performance in relation to the original design criteria. Performance that is closer to expectations increases the likelihood that limb scatter measurements by SNPP OMPS and successor instruments can form the basis for accurate long-term monitoring of ozone vertical profiles. The team finds that the Limb instrument operates mostly as designed and basic performance meets or exceeds the original design criteria. Internally scattered stray light and sensor pointing knowledge are two design challenges with the potential to seriously degrade performance. A thorough prelaunch characterization of stray light supports software corrections that are accurate to within 1% in radiances up to 60 km for the wavelengths used in deriving ozone. Residual stray light errors at 1000nm, which is useful in retrievals of stratospheric aerosols, currently exceed 10%. Height registration errors in the range of 1 km to 2 km have been observed that cannot be fully explained by known error sources. An unexpected thermal sensitivity of the sensor also causes wavelengths and pointing to shift each orbit in the northern hemisphere. Spectral shifts of as much as 0.5nm in the ultraviolet and 5 nm in the visible, and up to 0.3 km shifts in registered height, must be corrected in ground processing.

ozone↗

Overview of the Optomechanical Design of the LUVOIR Instruments

The Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR) is a space telescope being submitted for review to the 2020 Decadal Survey in Astronomy and Astrophysics. Its science objectives include both direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of planet, star, and galaxy formation, the transfer of matter between different galaxies, and the remote sensing of objects within the Solar System. Two architectures have been designed: a 15 m diameter on-axis telescope (LUVOIR-A) and an 8 m off-axis telescope (LUVOIR-B). This paper discusses the opto-mechanical design of the three LUVOIR instruments: the High Definition Imager (HDI), the LUVOIR UV Multi-object Spectrograph (LUMOS), and the Extreme Coronagraph for Living Planetary Systems (ECLIPS). For both the LUVOIR-A and LUVOIR-B variants of each instrument, optical design specifications are presented including first-order constraints, packaging requirements, and optical performance metrics. These factors are used to illustrate the final design of each instrument and LUVOIR as a whole. In addition to the optical designs, mechanical models are presented for each instrument showing the optical mounts, mechanisms, support structure, etc.

Decadal Study↗

Retrieving Aerosol Characteristics From the PACE Mission, Part 1: Ocean Color Instrument

NASA’s Plankton, Aerosol, Clouds, ocean Ecosystem (PACE) satellite mission is scheduled to launch in 2022, with the Ocean Color Instrument (OCI) on board. For the first time reflected sunlight from the Earth across a broad spectrum from the ultraviolet (UV: 350 nm) to the short wave infrared (SWIR: 2260 nm) will be measured from a single instrument at 1 km spatial resolution. While seven discrete bands will represent the SWIR, the spectrum from 350 to 890 nm will be continuously covered with a spectral resolution of 5 nm. OCI will thus combine in a single instrument (and at an enhanced spatial resolution for the UV) the heritage capabilities of the Moderate resolution Imaging Spectroradiometer (MODIS) and the Ozone Monitoring Instrument (OMI), while covering the oxygen A-band (O2A). Designed for ocean color and ocean biology retrievals, OCI also enables continuation of heritage satellite aerosol products and the development of new aerosol characterization from space. In particular the combination of MODIS and OMI characteristics allows deriving aerosol height, absorption and optical depth along with a measure of particle size distribution. This is achieved by using the traditional MODIS visible-to-SWIR wavelengths to constrain spectral aerosol optical depth and particle size. Extrapolating this information to the UV channels allows retrieval of aerosol absorption and layer height. A more direct method to derive aerosol layer height makes use of O2A absorption methods, despite the relative coarseness of the nominal 5 nm spectral resolution of OCI. Altogether the PACE mission with OCI will be an unprecedented opportunity for aerosol characterization that will continue climate data records from the past decades and propel aerosol science forward toward new opportunities.

PACE↗

Inter-Calibration of Nine UV Sensing Instruments Over Antarctica and Greenland Since 1980

Nadir-viewed intensities (radiances) from nine UV sensing satellite instruments are calibrated over the East Antarctic Plateau and Greenland during summer. The calibrated radiances from these UV instruments ultimately will provide a global long-term record of cloud trends and cloud response from ENSO events since 1980. We first remove the strong solar zenith angle dependence from the intensities using an empirical approach rather than a radiative trans-fer model. Then small multiplicative adjustments are made to these solar zenith angle normalized intensities in order to minimize differences when two or more instruments tempo-rally overlap. While the calibrated intensities show a negligible long-term trend over Antarctica and a statistically in-significant UV albedo trend of−0.05 % per decade over the interior of Greenland, there are small episodic reductions in intensities which are often seen by multiple instruments. Three of these darkening events are explained by boreal forest. Other events are caused by surface melting or volcanoes. We estimate a 2-sigma uncertainty of 0.35% for the calibrated radiances

Nadir-viewed intensities (radiances) from nine UV ↗

The Earth Model Column Collaboratory (EMC2) v1.1: An Open-Source Ground-Based Lidar and Radar Instrument Simulator and Subcolumn Generator for Large-Scale Models

Climate models are essential for our comprehensive understanding of Earth's atmosphere and can provide critical insights on future changes decades ahead. Because of these critical roles, today's climate models are continuously being developed and evaluated using constraining observations and measurements obtained by satellites, airborne, and ground-based instruments. Instrument simulators can provide a bridge between the measured or retrieved quantities and their sampling in models and field observations while considering instrument sensitivity limitations. Here we present the Earth Model Column Collaboratory (EMC2), an open-source ground-based lidar and radar instrument simulator and subcolumn generator, specifically designed for large-scale models, in particular climate models, but also applicable to high-resolution model output. EMC2 provides a flexible framework enabling direct comparison of model output with ground-based observations, including generation of subcolumns that may statistically represent finer model spatial resolutions. In addition, EMC2 emulates ground-based (and air- or space-borne) measurements while remaining faithful to large-scale models' physical assumptions implemented in their cloud or radiation schemes. The simulator uses either single particle or bulk particle size distribution lookup tables, depending on the selected scheme approach, to perform the forward calculations. To facilitate model evaluation, EMC2 also includes three hydrometeor classification methods, namely, radar- and sounding-based cloud and precipitation detection and classification, lidar-based phase classification, and a Cloud Feedback Model Intercomparison Project Observational Simulator Package (COSP) lidar simulator emulator. The software is written in Python, is easy to use, and can be straightforwardly customized for different models, radars, and lidars. Following the description of the logic, functionality, features, and software structure of EMC2, we present a case study of highly supercooled mixed-phase cloud based on measurements from the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE). We compare observations with the application of EMC2 to outputs from four configurations of the NASA Goddard Institute for Space Studies (GISS) climate model (ModelE3) in single-column model (SCM) mode and from a large-eddy simulation (LES) model. We show that two of the four ModelE3 configurations can form and maintain highly supercooled precipitating cloud for several hours, consistent with observations and LES. While our focus is on one of these ModelE3 configurations, which performed slightly better in this case study, both of these configurations and the LES results post-processed with EMC2 generally provide reasonable agreement with observed lidar and radar variables. As briefly demonstrated here, EMC2 can provide a lightweight and flexible framework for comparing the results of both large-scale and high-resolution models directly with observations, with relatively little overhead and multiple options for achieving consistency with model microphysical or radiation scheme physics.

Earth Model Column Collaboratory↗

Ozone Monitoring Instrument (OMI) collection 4: establishing a 17-year-long series of detrended level-1b data

The Ozone Monitoring Instrument (OMI) was launched on 15 July 2004, with an expected mission lifetime of 5 years. After more than 17 years in orbit the instrument is still functioning satisfactorily and in principle can continue doing so until the expected decommissioning of its platform Aura in 2025. In order to continue the datasets acquired by OMI and the Microwave Limb Sounder, the mission was extended up to at least 2023. Actions have been taken to ensure the proper functioning of the OMI operations, the data processing, and the calibration monitoring system until the eventual end of the mission. For the data processing a new level-0 (L0) to level-1b (L1b) data processor was built based on the recent developments for the TROPOspheric Monitoring Instrument (TROPOMI). With corrections for the degradation of the instrument now included, it is feasible to generate a new data collection to supersede the current collection-3 data products and reprocess the data of the entire mission up to now. This paper describes the differences between the collection-3 and collection-4 data. It will be shown that the collection-4 L1b data comprise a clear improvement with respect to the previous collections. By correcting for the gentle optical and electronic aging that has occurred over the past 17 years, OMI’s ability to make trend-quality ozone measurements has further improved.

UV↗

Report of the Instrumentation Frontier Working Group for Snowmass 2021

Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technologies and Research and Development (R&D) needed for future experiments in collider physics, neutrino physics, rare and precision physics and at the cosmic frontier. It is divided into more or less diagonal areas with some overlap among a few of them. We lay out five high-level key messages that are geared towards ensuring the health and competitiveness of the US detector instrumentation community, and thus the entire particle physics landscape.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗