Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

GaAs/silicon PVMirror tandem photovoltaic mini‐module with 29.6% efficiency with respect to the outdoor global irradiance

Abstract Balance‐of‐system costs now dominate the installed cost of photovoltaic systems, causing the annually averaged module efficiency to become a primary system cost driver. The resulting continued push towards higher module efficiencies, coupled with the dominance of single‐axis tracking in the utility‐scale PV market, may create an opportunity for a low‐concentration tandem module technology. Here, we demonstrate such a tandem, using the “PVMirror” concept, on the mini‐module scale. The tandem couples a (concentrating) silicon PVMirror having an aperture area of 156.25 cm 2 with a gallium arsenide receiver to achieve 29.6% efficiency with respect to the outdoor global irradiance. Unlike most concentrating technologies, the silicon PVMirror collects some of the diffuse light, but the tandem would nevertheless achieve 31% efficiency in the absence of diffuse light, as in a laboratory measurement. The same tandem technology can be implemented with a wide‐bandgap thin‐film PVMirror and silicon receiver—a potentially cost‐competitive combination—when efficient wide‐bandgap cells have been developed.

Yu, Zhengshan J.↗

Partial-Breast Irradiation Versus Whole-Breast Irradiation for Early-Stage Breast Cancer: A Cost-Effectiveness Analysis

Purpose: Accelerated partial-breast irradiation (PBI) is a new treatment paradigm for patients with early-stage breast cancer. Although PBI may lead to greater local recurrence rates, it may be cost-effective because of better tolerability and lower cost. We aim to determine the incremental cost-effectiveness of PBI compared with whole-breast radiation therapy (WBRT) for estrogen receptor-positive postmenopausal women treated for early-stage breast cancer. Methods and Materials: We developed a Markov model to describe health states in the 15 years after radiotherapy for early-stage breast cancer. External beam (EB) and MammoSite (MS) PBI were considered and assumed to be equally effective, but carried different costs. Patients received tamoxifen, but not chemotherapy. Utilities, recurrence risks, and costs were adapted from the literature; the baseline utility for no disease after radiotherapy was set at 0.92. Probabilistic sensitivity analyses were performed to model uncertainty in the PBI hazard ratio, recurrence pattern, and patient utilities. Costs (in 2004 US dollars) and quality-adjusted life-years were discounted at 3%/y. Results: The incremental cost-effectiveness ratio for WBRT compared with EB-PBI was $630,000/quality-adjusted life-year; WBRT strongly dominated MS-PBI. One-way sensitivity analysis found that results were sensitive to PBI hazard ratio, recurrence pattern, baseline recurrence risk, and no evidence of disease PBI utility values. Probabilistic sensitivity showed that EB-PBI was the most cost-effective technique over a wide range of assumptions and societal willingness-to-pay values. Conclusions: EB-PBI was the most cost-effective strategy for postmenopausal women with early-stage breast cancer. Unless the quality of life after MS-PBI proves to be superior, it is unlikely to be cost-effective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcome After Conservative Surgery and Breast Irradiation in 5,717 Patients With Breast Cancer: Implications for Supraclavicular Nodal Irradiation

Purpose: To evaluate the outcome and predictive factors of patients who underwent breast-conserving surgery and adjuvant radiotherapy to the whole breast only, without supraclavicular nodal irradiation. Methods and Materials: A total of 5,717 patients with pT1-T4 breast cancer were treated at the University of Florence. The median age of the patient population was 55 years (range, 30-80 years). All patients were followed for a median of 6.8 years (range, 1-27 years). Adjuvant chemotherapy was recommended in 1,535 patients (26.9%). Tamoxifen was prescribed in 2,951 patients (51.6%). The patients were split into three groups according to number of positive axillary nodes (PAN): P1, negative axillary lymph nodes; P2, one to three PAN; P3, more than three PAN. Results: The P3 patients had a higher incidence of supraclavicular fossa recurrence (SFR) compared with P2 and P1 patients. However, the incidence of SFR in P3 patients was low (only 5.5%), whereas the incidence of distant metastases (DM) was 27.2%. Distant metastasis was the only independent prognostic factor for breast cancer survival. Additionally, in the subgroup of patients who developed local recurrence, DM was the most important death predictor. Conclusion: Our series suggests that isolated SFR in patients who did not receive supraclavicular radiotherapy is infrequent, as well as in those patients who have more than three PAN, and SFR seems not to influence the outcome, which depends on DM occurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermomechanical treatment for improved neutron irradiation resistance of austenitic alloy (Fe-21Cr-32Ni)

An optimized thermomechanical treatment (TMT) applied to austenitic alloy 800H (Fe-21Cr-32Ni) had shown significant improvements in corrosion resistance and basic mechanical properties. This study examined its effect on radiation resistance by irradiating both the solution-annealed (SA) and TMT samples at 500 degrees C for 3 dpa. Microstructural characterization using transmission electron microscopy revealed that the radiation-induced Frank loops, voids, and y'-Ni3(Ti,Al) precipitates had similar sizes between the SA and TMT samples. The amounts of radiation-induced defects and more significantly y' precipitates, however, were reduced in the TMT samples. These reductions would approximately reduce by 40.9% the radiation hardening compared to the SA samples. This study indicates that optimized-TMT is an economical approach for effective overall property improvements.

99 GENERAL AND MISCELLANEOUS↗

Ag–TiO 2 Hybrid Nanocrystal Photocatalyst: Hydrogen Evolution under UV Irradiation but Not under Visible-Light Irradiation

In this work, we report a thermolytic reduction of silver precursors in the presence of anatase TiO 2 nanorods to form Ag–TiO 2 hybrid nanocrystals (HNCs). Upon changing the reaction conditions, the size and number density of Ag on the HNCs could be adjusted. The size and number density of Ag on the HNCs were found to have an inverse relation. We assess the hydrogen evolution of TiO 2 nanorods, P25 TiO 2 , and Ag–TiO 2 HNCs in methanol/water under xenon lamp irradiation. The turnover frequency for hydrogen evolution on silica-supported Ag–TiO 2 was 1.4 × 10 –4 s –1 , greater than that of the anatase TiO 2 nanorods (9.8 × 10 –6 s –1 ) or the coupled anatase/rutile TiO 2 (P25 catalyst; 5.2 × 10 –5 s –1 ).

36 MATERIALS SCIENCE↗

A computational study of x-ray emission from laser-irradiated Ge-doped foams

New advances in fabrication of low-density high-Z-doped foams have opened new windows on understanding how materials that are not in local thermodynamic equilibrium (LTE) are heated and radiate. Simulations are discussed in this paper of the x-ray spectral emissions from laser-irradiated very low-density Ge-doped silica aerogel targets using a two-dimensional radiation-hydrodynamics code incorporating a modern non-LTE superconfiguration atomic model. Details of the computational model are presented, and it is shown that, for the long-scale-length, subcritical-density, approx2-3 keV electron temperature plasmas created in experiments at the Omega laser facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)], the simulations provide a close match to both the measured Ge L-shell emission (approx1-1.5 keV) and the measured Ge K-shell emission (approx10-11 keV), but only by accounting properly for nonlocal thermal conduction. The older average-atom atomic model is shown to be inadequate for these non-LTE plasmas.

36 MATERIALS SCIENCE↗

Spectral analysis of x-ray emission created by intense laser irradiation of copper materials

We have measured the x-ray emission, primarily from K{sub {alpha}},K{sub {beta}}, and He{sub {alpha}} lines, of elemental copper foil and 'foam' targets irradiated with a mid-10{sup 16} W/cm{sup 2} laser pulse. The copper foam at 0.1 times solid density is observed to produce 50% greater He{sub {alpha}} line emission than copper foil, and the measured signal is well-fit by a sum of three synthetic spectra generated by the atomic physics code FLYCHK. Additionally, spectra from both targets reveal characteristic inner shell K{sub {alpha}} transitions from hot electron interaction with the bulk copper. However, only the larger-volume foam target produced significant K{sub {beta}} radiation, confirming a lower bulk temperature in the higher volume sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Graphitic carbon nanospheres: A Raman spectroscopic investigation of thermal conductivity and morphological evolution by pulsed laser irradiation

Graphitic carbon nanospheres (GCNSs) were prepared by a unique acidic treatment of multi-walled nanotubes. Spherical morphology with a narrow size distribution was confirmed by transmission electron microscopy studies. The room temperature Raman spectra showed a clear signature of D- and G-peaks at around 1350 and 1591 cm{sup −1}, respectively. Temperature dependent Raman scattering measurements were performed to understand the phonon dynamics and first order temperature coefficients related to the D- and G-peaks. The temperature dependent Raman spectra in a range of 83–473 K were analysed, where the D-peak was observed to show a red-shift with increasing temperature. The relative intensity ratio of D- to G-peaks also showed a significant rise with increasing temperature. Such a temperature dependent behaviour can be attributed to lengthening of the C-C bond due to thermal expansion in material. The estimated value of the thermal conductivity of GCNSs ∼0.97 W m{sup −1} K{sup −1} was calculated using Raman spectroscopy. In addition, the effect of pulsed laser treatment on the GCNSs was demonstrated by analyzing the Raman spectra of post irradiated samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the Necessity of Adopting Irradiation Protocols Recommended by the Compatibility in Irradiation Research Protocols Expert Roundtable (CIRPER) in Published Research and Why It Matters to Health Physicists

The National Nuclear Security Administration (NNSA) seeks to assist and support all partners in the fields of radiobiology, health physics, radiation physics, and related areas to transition from cesium-137 chloride-based technologies that can potentially be used in an act of terrorism to X-ray technologies. The absence of information on experimental procedures, equipment, and irradiation parameters directly and negatively impacts the reproducibility and translatability of a sizable portion of radiation biology studies. It also discourages researchers from adopting new tools that eliminate the risks of a radiological dispersal device.

Stern, Warren [Brookhaven National Laboratory (BNL↗