Search NASA⌕ Search

SEARCH · Search NASA

Results for “ISOLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Rotating disk transition due to isolated roughness with intense acoustic irradiation

The low transition Reynolds numbers associated with boundary-layers which exhibit crossflow instability have made them an important area of study in fluid mechanics. An excellent test bed for the study of this flow is a flat disk rotating in still fluid. An experimental investigation of stability and transition of a rotating disk boundary-layer has been conducted. The effects of isolated roughness elements and acoustic forcing, both alone and in combination, were considered. The flow showed no receptivity to intense monochromatic acoustic forcing except in the presence of sizable roughness. A case was investigated where the growth of the primary instability, seeded by an isolated roughness element, was positively altered in the presence of sound, leading to a downstream movement of transition. In agreement with the work of several investigators, the results of this study suggest that receptivity to long wavelength phenomena, such as traveling sound waves, is contingent upon the presence of strong localized pressure gradients (such as those introduced by roughness) to reduce the length scales of the disturbance to those which are consistent with unstable wavelengths in the flow field.

Waitz, Ian A.↗

Siphon flows in isolated magnetic flux tubes. II - Adiabatic flows

This paper extends the study of steady siphon flows in isolated magnetic flux tubes surrounded by field-free gas to the case of adiabatic flows. The basic equations governing steady adiabatic siphon flows in a thin, isolated magnetic flux tube are summarized, and qualitative features of adiabatic flows in elevated, arched flux tubes are discussed. The equations are then cast in nondimensional form and the results of numerical computations of adiabatic siphon flows in arched flux tubes are presented along with comparisons between isothermal and adiabatic flows. The effects of making the interior of the flux tube hotter or colder than the surrounding atmosphere at the upstream footpoint of the arch is considered. In this case, is it found that the adiabatic flows are qualitatively similar to the isothermal flows, with adiabatic cooling producing quantitative differences. Critical flows can produce a bulge point in the rising part of the arch and a concentration of magnetic flux above the bulge point.

Montesinos, Benjamin↗

Advanced detection, isolation, and accommodation of sensor failures in turbofan engines: Real-time microcomputer implementation

The objective of the Advanced Detection, Isolation, and Accommodation Program is to improve the overall demonstrated reliability of digital electronic control systems for turbine engines. For this purpose, an algorithm was developed which detects, isolates, and accommodates sensor failures by using analytical redundancy. The performance of this algorithm was evaluated on a real time engine simulation and was demonstrated on a full scale F100 turbofan engine. The real time implementation of the algorithm is described. The implementation used state-of-the-art microprocessor hardware and software, including parallel processing and high order language programming.

Delaat, John C.↗

A new approach to active vibration isolation for microgravity space experiments

A new method was developed to design an active vibration isolation system for microgravity space experiments. This method yields the required controller transfer functions for a specified transmissibility ratio. Hence, it is a straightforward task to guarantee that the desired vibration isolation performance is achieved at each frequency. The theory for such a controller design was presented by considering a single degree of freedom system. In addition, the magnitude of the input required by the new method has been found to be less than that used by a standard phase lead/lag compensator.

Sinha, Alok↗

Electrical isolation design and electrochemical corrosion in thin-film photovoltaic modules

The development of a proposed wet insulation-resistance qualification test specification for production-line modules is presented. Laboratory research directed toward understanding and eliminating problems associated with electrical isolation of thin-film photovoltaic module circuitry is presented. Test results serve to measure module field life as limited by electrochemical corrosion degradation mechanisms. Current module-level research covering encapsulant voltage withstand capability is also described, and suggestions for improving module electrical isolation are offered.

Sugimura, R. S.↗

Combined infrared and ultraviolet-visible spectroscopy matrix-isolated carbon vapor

Infrared and UV-visible absorption spectra have been measured on the same sample of matrix-isolated carbon vapor in order to establish correlations between absorption intensities of vibrational and electronic transitions as a function of sample annealing. A high degree of correlation has been found between the IR feature at 1998/cm recently assigned to C8 and a UV absorption feature at about 3100 A. Thus, for the first time, direct evidence is given for the assignment of one of the unknown UV-visible features of the long-studied matrix-isolated carbon vapor spectrum.

Kurtz, Joe↗

Calibration of polarimetric radar systems with good polarization isolation

A practical technique is proposed for calibrating single-antenna polarimetric radar systems using a metal sphere plus any second target with a strong cross-polarized radar cross section. This technique assumes perfect isolation between antenna ports. It is shown that all magnitudes and phases (relative to one of the like-polarized linear polarization configurations) of the radar transfer function can be calibrated without knowledge of the scattering matrix of the second target. Comparison of the values measured (using this calibration technique) for a tilted cylinder at X-band with theoretical values shows agreement within + or - 0.3 dB in magnitude and + or - 5 degrees in phase. The radar overall cross-polarization isolation was 25 dB. The technique is particularly useful for calibrating a radar under field conditions, because it does not require the careful alignment of calibration targets.

Sarabandi, Kamal↗

An experimental and analytical investigation of isolated rotor flap-lag stability in forward flight

The flap-lag stability of an isolated hingeless rotor is investigated, both experimentally and analytically, in hover and in forward flight. The effects of forward flight aerodynamics on regressing lead-lag mode stability are the focus of the investigation. The soft-inplane, three-bladed, isolated model rotor was operated untrimmed at advance ratios from hover to 0.55 and at shaft angles as high as 20 deg. The experimental data base includes forward flight damping data for two lead-lag natural frequencies, for three values of collective pitch, and for both zero and full-lag structural coupling. With the aid of computerized symbolic manipulation, a rigid-blade lag-flap model analysis was developed to calculate the Floquent eigenvalues and to identify the modes. Good correlation is shown for some cases, but other cases show large discrepancies between the theory and experiment.

Gaonkar, Gopal H.↗

Optical Isolators With Transverse Magnets

New design for isolator includes zigzag, forward-and-backward-pass beam path and use of transverse rather than longitudinal magnetic field. Design choices produce isolator with as large an aperture as desired using low-Verdet-constant glass rather than more expensive crystals. Uses commercially available permanent magnets in Faraday rotator. More compact and less expensive. Designed to transmit rectangular beam. Square cross section of beam extended to rectangular shape by increasing one dimension of glass without having to increase magnetic field. Potentially useful in laser systems involving slab lasers and amplifiers. Has applications to study of very-high-power lasers for fusion research.

Fan, Yuan X.↗

Mechanical isolation for gravity gradiometers

In principle, gravity gradiometers are immune to the effects of acceleration and vibrations. In real instruments, scale factor errors and structural compliance lead to undesired instrument outputs. Described here are the instruments and the fundamental sources of the problems, a calculation of the magnitude of the effects, a demonstration of the need for isolation in the Shuttle (indeed, almost any spacecraft), and the Jet Propulsion Laboratory eddy current isolation technique and its current development status.

Sonnabend, David↗

Microgravity vibration isolation: An optimal control law for the one-dimensional case

Certain experiments contemplated for space platforms must be isolated from the accelerations of the platform. An optimal active control is developed for microgravity vibration isolation, using constant state feedback gains (identical to those obtained from the Linear Quadratic Regulator (LQR) approach) along with constant feedforward gains. The quadratic cost function for this control algorithm effectively weights external accelerations of the platform disturbances by a factor proportional to (1/omega) exp 4. Low frequency accelerations are attenuated by greater than two orders of magnitude. The control relies on the absolute position and velocity feedback of the experiment and the absolute position and velocity feedforward of the platform, and generally derives the stability robustness characteristics guaranteed by the LQR approach to optimality. The method as derived is extendable to the case in which only the relative positions and velocities and the absolute accelerations of the experiment and space platform are available.

Hampton, Richard D.↗

Mechanical strain isolator mount

Certain devices such as optical instruments must preserve their alignmental integrity while being subjected to mechanical strain. A mechanical strain isolator mount is provided to preserve the alignmental integrity of an alignment sensitive instrument. An alignment sensitive instrument is mounted on a rectangular base. Flexural legs are connected at their proximal ends to the rectangular base. Flexural legs are also spaced parallel to the sides. Mounting pads are connected to the legs at the distal end and the mechanical strain isolator mount is attached to the substrate by means of threaded bolts. When a mounting pad and its respective leg is subjected to lateral strain in either the X or Y direction via the substrate, the respective leg relieves the strain by bending in the direction of the strain. An axial strain on a mounting pad in the Z direction is relieved by a rotational motion of the legs in the direction of the strain. When the substrate is stress free, the flexural legs return to their original condition and thus preserve the original alignment integrity of the alignment sensitive instrument.

James, Gordon E.↗

Thermally isolated deployable shield for spacecraft

A thermally isolated deployable shield for spacecraft is provided utilizing a plurality of lattice panels stowable generally against the craft and deployable to some fixed distance from the craft. The lattice panels are formed from replaceable shield panels affixed to lattice structures. The lattice panels generally encircle the craft providing 360 degree coverage therearound. Actuation means are provided from translating the shield radially outward from the craft and thermally isolating the shield from the craft. The lattice panels are relatively flexible, allowing the shield to deploy to variable diameters while retaining uniform curvature thereof. Restraining means are provided for holding the shield relatively tight in its stowed configuration. Close-out assemblies provide light sealing and protection of the annular spaces between the deployed shield and the crafts end structure.

Redmon, John W., Jr.↗

A new approach to controller design for microgravity isolation systems

A new method has been developed to design an active vibration isolation system for microgravity space experiments. This method yields the required controller transfer functions for a specified transmissibility. Hence, it is a straightforward task to guarantee that the desired vibration isolation performance is achieved at each frequency. The theory for such a controller design has been presented by considering a single degree of freedom system. The magnitude of the control force required by the new method has been found to be less than that used by a standard phase lead/lag compensator.

Sinha, A.↗

Microgravity vibration isolation: An optimal control law for the one-dimensional case

Certain experiments contemplated for space platforms must be isolated from the accelerations of the platforms. An optimal active control is developed for microgravity vibration isolation, using constant state feedback gains (identical to those obtained from the Linear Quadratic Regulator (LQR) approach) along with constant feedforward (preview) gains. The quadratic cost function for this control algorithm effectively weights external accelerations of the platform disturbances by a factor proportional to (1/omega)(exp 4). Low frequency accelerations (less than 50 Hz) are attenuated by greater than two orders of magnitude. The control relies on the absolute position and velocity feedback of the experiment and the absolute position and velocity feedforward of the platform, and generally derives the stability robustness characteristics guaranteed by the LQR approach to optimality. The method as derived is extendable to the case in which only the relative positions and velocities and the absolute accelerations of the experiment and space platform are available.

Hampton, R. D.↗

Fault detection and isolation for multisensor navigation systems

Increasing attention is being given to the problem of erroneous measurement data for multisensor navigation systems. A recursive estimator can be used in conjunction with a 'snapshot' batch estimator to provide fault detection and isolation (FDI) for these systems. A recursive estimator uses past system states to form a new state estimate and compares it to the calculated state based on a new set of measurements. A 'snapshot' batch estimator uses a set of measurements collected simultaneously and compares solutions based on subsets of measurements. The 'snapshot' approach requires redundant measurements in order to detect and isolate faults. FDI is also referred to as Receiver Autonomous Integrity Monitoring (RAIM).

Kline, Paul A.↗

Characterizing and testing a thermally isolating superconducting link for SAFIRE-like missions

The recent discovery of high temperature ceramic superconductors with transition temperatures above 90 K has opened the possibilities for new space applications. One application is the fabrication of an electrically conducting and thermally isolating electronic link to connect IR detectors to data acquisition electronics on remote sensing platforms. The Spectroscopy of the Atmosphere using Far Infra-Red Emission (SAFIRE) mission is an example of a platform which employs hybrid dewars and combines both mechanical and cryogenic liquid cooling. This new technology is limited by the heat conducted through sensor array leads that connect the electronics (at approximately 80 K) to the sensors (at approximately 4 K). This link must be made of material that has high electrical conductivity and high thermal resistance. The YBa2Cu3O(x) superconductor with a transition temperature, T(sub c), of 93 K can achieve these conflicting requirements. A link with these characteristics will improve the thermal isolation of IR detectors and will increase the lifetime of the cryogen. A reduction of the thermal load due to the link by a factor of four will increase the lifetime of a seven year mission by about one year.

Selim, Raouf L.↗