Search NASA⌕ Search

SEARCH · Search NASA

Results for “Injections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Engine Company Evaluation of Feasibility of Aircraft Retrofit Water-Injected Turbomachines

This study supports the NASA Glenn Research Center and the U.S. Air Force Research Laboratory in their efforts to evaluate the effect of water injection on aircraft engine performance and emissions. In this study, water is only injected during the takeoff and initial climb phase of a flight. There is no water injection during engine start or ground operations, nor during climb, cruise, descent, or landing. This study determined the maintenance benefit of water injection during takeoff and initial climb and evaluated the feasibility of retrofitting a current production engine, the PW4062 (Pratt & Whitney, East Hartford, CT), with a water injection system. Predicted NO(x) emissions based on a 1:1 water-tofuel ratio are likely to be reduced between 30 to 60 percent in Environmental Protection Agency parameter (EPAP). The maintenance cost benefit for an idealized combustor water injection system installed on a PW4062 engine in a Boeing 747-400ER aircraft (The Boeing Company, Chicago, IL) is computed to be $22 per engine flight hour (EFH). Adding water injection as a retrofit kit would cost up to $375,000 per engine because of the required modifications to the fuel system and addition of the water supply system. There would also be significant nonrecurring costs associated with the development and certification of the system that may drive the system price beyond affordability.

Becker, Arthur↗

FDDI network test adaptor error injection circuit

An apparatus for injecting errors into a FDDI token ring network is disclosed. The error injection scheme operates by fooling a FORMAC into thinking it sent a real frame of data. This is done by using two RAM buffers. The RAM buffer normally accessed by the RBC/DPC becomes a SHADOW RAM during error injection operation. A dummy frame is loaded into the shadow RAM in order to fool the FORMAC. This data is just like the data that would be used if sending a normal frame, with the restriction that it must be shorter than the error injection data. The other buffer, the error injection RAM, contains the error injection frame. The error injection data is sent out to the media by switching a multiplexor. When the FORMAC is done transmitting the data, the multiplexor is switched back to the normal mode. Thus, the FORMAC is unaware of what happened and the token ring remains operational.

Eckenrode, Thomas↗

Robust Ceramic Coaxial Cable Down-Hole Sensors for Long-Term In Situ Monitoring of Geologic CO 2 Injection and Storage

Energy generation by use of fossil fuels produces large volumes of CO 2 and other greenhouse gases, whose accumulation in the atmosphere is widely seen as undesirable. CO 2 Capture followed by sequestration has been identified as the solution. Subsurface geologic formations offer a potential location for long-term storage of CO 2 because of their requisite size. Unfortunately, the inaccessibility and complexity of the subsurface, the wide range of scales of variability, and the coupled nonlinear processes, impose tremendous challenges to determine the transport and predict the fate of the stored CO 2 . Among the various monitoring approaches, in situ down-hole monitoring of the various state parameters provides critical and direct data points that can be used to validate the models, optimize the injection, detect leakage and track the CO 2 plume. However, down-hole sensors that can withstand the harsh conditions and operate over decades of the project lifecycle remain unavailable. Given that the widespread of carbon capture and storage will be the necessity and reality in the future, fundamental and applied research is required to address the significant challenges and technological gaps in lack of long-term reliable down-hole sensors This project focused on the development and demonstration of a novel, low-cost, distributed, robust ceramic coaxial cable sensor platform for in situ down-hole monitoring of geologic CO 2 injection and storage with high spatial and temporal resolutions. The coaxial cable Fabry-Perot interferometer (CCFPI) has been studied as a general sensor platform for in situ, long-term, measurement of temperature, pressure and strain, which are critical to CO 2 injection and storage. A novel signal processing scheme has been developed and demonstrated for dense multiplexing of the sensors for low-cost distributed sensing with high spatial resolution. The developed temperature, pressure and strain sensors have been extensively tested under laboratory conditions that are similar to the downhole CO 2 storage environment, showing excellent capability for in situ monitoring the various parameters that are important to model, optimize the injection, detect leakage and track the CO 2 plume. In addition, the interactions between the sensor datum and the geological models have been investigated in details for the purposes of model validation, guiding sensor installation/placement, enhancement of model prediction capability and optimization of the injection processes. This project has resulted in the successful development of new ceramic coaxial cable based sensor systems that can monitor directly the changes in pressure, temperature, and strain caused by increased reservoir pressure and reduced reservoir temperature due to the supercritical CO 2 injection. Integrated with geological models, the sensors and measurement data can improve the possibility to identify plume movement and leakage in the cap rock and wells with higher precision and more accuracy. The low cost, ease of deployment, small size and dense multiplexing features of the new sensing technology will allow a large number of sensors to be deployed to address the objective to demonstrate that 99% of the CO 2 remains in the injection zone.

01 COAL, LIGNITE, AND PEAT↗

In-Situ Uranium Stabilization Through Polyphosphate Injection: Pilot-Scale Treatability Test at the 300 Area, Hanford Site

This paper describes the pilot-scale treatability test that was conducted to evaluate the efficacy of using a polyphosphate injection approach to treat uranium-contaminated groundwater in situ within the 300 Area aquifer at the Hanford Site in Richland, Washington. Primary test objectives were to assess 1) direct treatment of available uranium contributing to the groundwater plume through precipitation of the uranyl-phosphate mineral autunite, and 2) emplacement of secondary-treatment capacity via precipitation of the calcium-phosphate mineral apatite, which acts as a long-term sorbent for uranium. Based on an injection design analysis that incorporated results from both bench-scale testing and site-specific characterization activities, a three-phase injection approach was selected for field-scale testing. This approach consisted of 1) an initial polyphosphate injection to facilitate direct treatment of aqueous uranium in the pore space, 2) a second phase consisting of a calcium chloride injection to provide an available calcium source for the creation of apatite, and 3) a subsequent polyphosphate injection to supply a phosphate source for the formation of apatite. The total-solution volume injected during this field test was approximately 3.8 million L (1 million gal). Results from this investigation will be used to identify implementation challenges and investigate the technology's ability to meet remedial objectives. In addition, data from this test will provide valuable information for designing a full-scale remedial action for uranium in groundwater beneath the 300 Area of the Hanford Site, and a detailed understanding of the fundamental underpinnings necessary to evaluate the efficacy and potential for utilization of the polyphosphate technology at other sites with varying geochemical and hydrodynamic conditions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experiences from First Top-Off Injection at the Stanford Synchrotron Radiation Lightsource

As the Stanford Synchrotron Radiation Lightsource (SSRL) of the SLAC National Accelerator Laboratory (SLAC) is moving toward Top-Off injection mode, SLAC's Radiation Protection Department is working with SSRL on minimizing the radiological hazards of this mode. One such hazard is radiation that is created inside the accelerator concrete enclosure by injected beam. Since during Top-Off injection the stoppers that would otherwise isolate the storage ring from the experimental area stay open, the stoppers no longer prevent such radiation from reaching the experimental area. The level of this stray radiation was measured in April 2008 during the first Top-Off injection tests. They revealed radiation dose rates of up to 18 microSv/h (1.8 millirem/h) outside the experimental hutches, significantly higher than our goal of 1 microSv/h (0.1 millirem/h). Non-optimal injection increased the measured dose rates by a factor two. Further tests in 2008 indicated that subsequent improvements by SSRL to the injection system have reduced the dose rates to acceptable levels. This presentation describes the studies performed before the Top-Off tests, the tests themselves and their major results (both under initial conditions and after improvements were implemented), and presents the controls being implemented for full and routine Top-Off injection.

43 PARTICLE ACCELERATORS↗

Laser-driven accelerators by colliding pulses injection: A review of simulation and experimental results

A review of recent simulation and experimental studies of the colliding pulse injection scheme is presented. One dimensional particle in cell simulations show that when the colliding pulses have parallel polarizations, the dominant effects that have to be considered for modeling electron injection in plasma waves are (i) stochastic heating and (ii) wakefield inhibition at the collision. With cross polarized pulses, injection of an electron beam is still possible because stochastic heating still occurs. However, it is found numerically that the injection threshold is higher in this case. The simulations also underline the possibility of tuning the electron beam parameters by modifying the injection laser pulse. Experiments (i) validate these scenarios and show that stable and high quality electron beams are produced when two counterpropagating laser pulses collide in an underdense plasma and (ii) confirm very clearly the existence of a threshold for injection, which is higher with cross polarized pulses than with parallel polarized pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stability of High Power Beam Injection in Negative-Ion-Based LHD-NBI

We describe the characteristic of stable beam injection in a neutral beam injector (NBI) for Large Helical Device (LHD) in high injection power of more than 6 MW. In the NBI, it takes a week after starting Cs seeding to finish the pre-injection conditioning. The injection starts with the beam power {approx}6.2 MW, and the maximum power reaches {approx}7 MW. The Cs-seeding rate affects the beam stability in such high power injections. By optimizing the rate to 0.65 mg/shot, the success ratio, which is defined as a ratio of actual pulse duration to setting one, increases to 85-90% in the power and energy range of more than 6.2 MW and 185 keV, respectively. The weights of Cs adsorbed on several surfaces in the ion sources of the NBI are measured by means of Inductively-Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), and averaged surface densities are calculated by dividing with the several surface areas. The seeded Cs of 99.5% is condensed in the plasma generator, and very tiny amount of Cs reaches the surfaces of the accelerator grids. This very low amount of Cs on the grids is interpreted that most of the Cs atom evaporated from the inner walls is ionized during the arc discharges, and repelled to the source plasmas by the electrostatic field for H- extraction.

43 PARTICLE ACCELERATORS↗

Dipolarizing flux bundles in the cis-geosynchronous magnetosphere: Relationship between electric fields and energetic particle injections

Dipolarizing flux bundles (DFBs) are small flux tubes (typically <3 R E in X GSM and Y GSM ) in the nightside magnetosphere that have magnetic field more dipolar than the background. Although DFBs are known to accelerate particles, creating energetic particle injections outside geosynchronous orbit (trans-GEO), the nature of the acceleration mechanism and the importance of DFBs in generating injections inside geosynchronous orbit (cis-GEO) are unclear. Our statistical study of cis-GEO DFBs using data from the Van Allen Probes reveals that just like trans-GEO DFBs, cis-GEO DFBs occur most often in the premidnight sector, but their occurrence rate is ~1/3 that of trans-GEO DFBs. Half the cis-GEO DFBs are accompanied by an energetic particle injection and have an electric field 3 times stronger than that of the injectionless half. All DFB injections are dispersionless within the temporal resolution considered (11 s). In conclusion, our findings suggest that these injections are ushered or produced locally by the DFB, and the DFB's strong electric field is an important aspect of the injection generation mechanism.

58 GEOSCIENCES↗

Aseismic Motions Drive a Sparse Seismicity During Fluid Injections Into a Fractured Zone in a Carbonate Reservoir

An increase in fluid pressure in faults can trigger seismicity and large aseismic motions. Understanding how fluid and faults interact is an essential goal for seismic hazard and reservoir monitoring, but this key relation remains unclear. We developed an in situ experiment of fluid injections at a 10 meter scale. Water was injected at high pressure in different geological structures inside a fault damaged zone, in limestone at 280 m depth in the Low Noise Underground Laboratory (France). Induced seismicity, as well as strains, pressure, and flow rate, was continuously monitored during the injections. Although nonreversible deformations related to fracture reactivations were observed for all injections, only a few tests generated seismicity. Events are characterized by a 0.5-to-4 kHz content and a small magnitude (approximately -3.5). They are located within 1.5 m accuracy between 1 and 12 m from the injections. Comparing strain measurements and seismicity shows that more than 96% of the deformation is aseismic. The seismic moment is also small compared to the one expected from the injected volume. Moreover, a dual seismic behavior is observed as (1) the spatiotemporal distribution of some cluster of events is clearly independent from the fluid diffusion (2) while a diffusion-type pattern can be observed for some others clusters. Furthermore, the seismicity might therefore appear as an indirect effect to the fluid pressure, driven by aseismic motion and related stress perturbation transferred through failure.

58 GEOSCIENCES↗

Rapid Quantitation of Ascorbic and Folic Acids in SRM 3280 Multivitamin/Multielement Tablets using Flow-Injection Tandem Mass Spectrometry

RATIONALE: Ascorbic acid (AA) and folic acid (FA) are water-soluble vitamins and are usually fortified in food and dietary supplements. For the safety of human health, proper intake of these vitamins is recommended. Improvement in the analysis time required for the quantitative determination of these vitamins in food and nutritional formulations is desired. METHODS: A simple and fast (~5 min) in-tube sample preparation was performed, independently for FA and AA, by mixing extraction solvent with a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Quantitative detection was achieved by flow-injection (1 L injection volume) electrospray ionization tandem mass spectrometry (ESI-MS/MS) in negative ion mode using the method of standard addition. RESULTS: Method of standard addition was employed for the quantitative estimation of each vitamin in a sample extract. At least 2 spiked and 1 non-spiked sample extract were injected in triplicate for each quantitative analysis. Given an injection-to-injection interval of approximately 2 min, about 18 min was required to complete the quantitative estimation of each vitamin. The concentration values obtained for the respective vitamins in the standard reference material (SRM) 3280 using this approach were within the statistical range of the certified values provided in the NIST Certificate of Analysis. The estimated limit of detections of FA and AA were 13 and 5.9 ng/g, respectively. CONCLUSIONS: Flow-injection ESI-MS/MS was successfully applied for the rapid quantitation of FA and AA in SRM 3280 multivitamin/multielement tablets.

ascorbic acid↗

Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 {+-} 9 min in the gadolinium-enhanced saline solution group and 22 {+-} 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive mesh based combustion simulations of direct fuel injection effects in a supersonic cavity flame-holder

Here, we present high-fidelity reacting simulations of a supersonic cavity flame-holder configuration. The focus of this work is on flame stabilization brought about by varying the location of fuel injection in a cavity stabilized supersonic flow of air. Central to our approach is a compressible multi-species reacting flow solver that uses adaptive-mesh-refinement (AMR), enabling the resolution of flame, shock-waves, boundary-layers, and small-scale structures in the computational domain. Our analysis indicates that fuel injection closer to the ramp at the aft end of the cavity allows for greater mixing and lower peak temperatures compared to fuel injection upstream that is closer to the backward facing step of the cavity. This difference is mainly due to greater turbulent fluctuations generated from the shear-layer towards the cavity ramp, thereby enhancing the mixing of fuel and air. A low frequency oscillatory behaviour in heat-release and pressure was also observed for the upstream injection case while a much higher-frequency phenomena was observed in the near-ramp injection case. By identifying the important physical determinants of the combustion processes, this study illustrates a promising pathway to design and optimize direct fuel injection strategies in supersonic cavity flame-holders that can improve flame stability, combustion efficiency, and reduce emissions.

42 ENGINEERING↗

Enhanced energy conversion efficiency promoted by cavitation in gasoline direct injection

High-pressure direct fuel injection plays the most crucial role in energy conversion and improving engine combustion efficiency and emission. The optimization of turbulent and multiphase fuel injection has focused on controlling hydrodynamic parameters such as injection pressure. While the thermodynamic influence is often considered in the flash boiling situation, we inquire into how gasoline-type fuel’s hydro- and thermodynamic properties impact the injection dynamics by fuel-temperature induced cavitation. The turbulent and cavitating flows emanating from the direct-injection nozzle is visualized by ultrafast x-ray imaging with an unprecedented spatiotemporal resolution. The ultrafast liquid-fuel dynamics are dominated by injection pressure as well as fuel temperature through cavitation, an important thermodynamic parameter but often difficult to control in engine combustion. With the most direct and quantitative measurement, we discovered that the near-nozzle fuel-jet dynamics can be perfectly scaled by a single dimensionless parameter, cavitation number, particularly sensitive to the fuel temperature, in a wide operation range. This universal scaling shows that cavitation can be harnessed to elevate the pneumatic-hydraulic to kinetic energy conversion efficiency, critical for promoting fuel atomization and engine combustion performance. This enhancement effect will have even more impact on engine combustion using alternative low-emission fuels with higher saturated vapor pressure.

30 DIRECT ENERGY CONVERSION↗

Reservoir-scale model of geologic hydrogen production from serpentinization: Cyclic injection in a dual-permeability fracture-matrix system

Geologic hydrogen (GeoH 2 ) from serpentinization is a promising low-carbon resource, but its reservoir-scale behavior remains poorly understood. We develop a dual-permeability reactive transport model for an injector–producer well pair in ultramafic rock that couples multiphase flow, heat transfer, geochemistry, and porosity–permeability evolution. Here, the model is calibrated to olivine flow-through experiments and upscaled to two-year long simulations with continuous injection and cyclic injection with shut-in-to-injection ratios (SIR = 1, 0.5, 0.1). Olivine reacts along high-flux pathways to form lizardite and magnetite, increasing pH; H 2 (aq) and H 2 (g) peak early and then decline as exsolution and advective export outpace local generation. Continuous injection yields the highest cumulative H 2 but the lowest water-use efficiency (1.138 x 10 –6 mol/kgw). Cyclic injection increases this ratio to 1.35 x 10 –6 , 1.377 x 10 –6 , and 1.182 x 10 –6 mol/kgw for SIR = 1, 0.5, and 0.1, respectively; SIR = 0.5 provides a ~20% improvement over continuous injection and the best compromise for pilot design.

08 HYDROGEN↗

A Multi-institutional Clinical Trial of Rectal Dose Reduction via Injected Polyethylene-Glycol Hydrogel During Intensity Modulated Radiation Therapy for Prostate Cancer: Analysis of Dosimetric Outcomes

Purpose: To characterize the effect of a prostate-rectum spacer on dose to rectum during external beam radiation therapy for prostate cancer and to assess for factors correlated with rectal dose reduction. Methods and Materials: Fifty-two patients at 4 institutions were enrolled into a prospective pilot clinical trial. Patients underwent baseline scans and then were injected with perirectal spacing hydrogel and rescanned. Intensity modulated radiation therapy plans were created on both scans for comparison. The objectives were to establish rates of creation of ≥7.5 mm of prostate-rectal separation, and decrease in rectal V70 of ≥25%. Multiple regression analysis was performed to evaluate the associations between preinjection and postinjection changes in rectal V70 and changes in plan conformity, rectal volume, bladder volume, bladder V70, planning target volume (PTV), and postinjection midgland separation, gel volume, gel thickness, length of PTV/gel contact, and gel left-to-right symmetry. Results: Hydrogel resulted in ≥7.5-mm prostate-rectal separation in 95.8% of patients; 95.7% had decreased rectal V70 of ≥25%, with a mean reduction of 8.0 Gy. There were no significant differences in preinjection and postinjection prostate, PTV, rectal, and bladder volumes. Plan conformities were significantly different before versus after injection (P=.02); plans with worse conformity indexes after injection compared with before injection (n=13) still had improvements in rectal V70. In multiple regression analysis, greater postinjection reduction in V70 was associated with decreased relative postinjection plan conformity (P=.01). Reductions in V70 did not significantly vary by institution, despite significant interinstitutional variations in plan conformity. There were no significant relationships between reduction in V70 and the other characteristics analyzed. Conclusions: Injection of hydrogel into the prostate-rectal interface resulted in dose reductions to rectum for >90% of patients treated. Rectal sparing was statistically significant across a range of 10 to 75 Gy and was demonstrated within the presence of significant interinstitutional variability in plan conformity, target definitions, and injection results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Implications of an Injection of Hyaluronic Acid for Preserving the Rectal Wall in Prostate Stereotactic Body Radiation Therapy

Purpose: This study assessed the contribution of ahyaluronic acid (HA) injection between the rectum and the prostate to reducing the dose to the rectal wall in stereotactic body radiation therapy (SBRT). Methods and Materials: As part of a phase 2 study of hypofractionated radiation therapy (62 Gy in 20 fractions), the patients received a transperineal injection of 10 cc HA between the rectum and the prostate. A dosimetric computed tomographic (CT) scan was systematically performed before (CT1) and after (CT2) the injection. Two 9-beam intensity modulated radiation therapy-SBRT plans were optimized for the first 10 patients on both CTs according to 2 dosage levels: 5 × 6.5 Gy (PlanA) and 5 × 8.5 Gy (PlanB). Rectal wall parameters were compared with a dose–volume histogram, and the prostate–rectum separation was measured at 7 levels of the prostate on the center line of the organ. Results: For both plans, the average volume of the rectal wall receiving the 90% isodose line (V90%) was reduced up to 90% after injection. There was no significant difference (P=.32) between doses received by the rectal wall on CT1 and CT2 at the base of the prostate. This variation became significant from the median plane to the apex of the prostate (P=.002). No significant differences were found between PlanA without HA and PlanB with HA for each level of the prostate (P=.77, at the isocenter of the prostate). Conclusions: HA injection significantly reduced the dose to the rectal wall and allowed a dose escalation from 6.5 Gy to 8.5 Gy without increasing the dose to the rectum. A phase 2 study is under way in our department to assess the rate of acute and late rectal toxicities when SBRT (5 × 8.5 Gy) is combined with an injection of HA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling the effect of nitrogen recycling on the erosion and leakage of tungsten impurities from the SAS-VW divertor in DIII-D during nitrogen gas injection

The new SAS-VW divertor in DIII-D has tungsten-coated components to enable the study of tungsten erosion and leakage from a closed, slot-like divertor. A proposed method of actively managing the tungsten impurities is to inject low-Z impurities, such as nitrogen, into the Scrape-off-Layer (SOL) to modify the conditions in the plasma boundary and in turn manipulate both the erosion and subsequent transport of tungsten. Nitrogen injection from the SOL crown has been modeled using SOLPS-ITER to calculate the background plasma including the intrinsic carbon and the injected nitrogen impurities, and subsequently DIVIMP has been used to calculate the tungsten erosion and transport on top of the background plasma solution. This workflow has been used to model scenarios at a variety of nitrogen injection rates with different assumptions about the nitrogen recycling at the target. In the scenario modeled here, an optimal nitrogen injection rate around 3-4 x 10 20 N/s is found to reduce the amount of tungsten reaching the core by a factor of about 2.4. However, when the nitrogen recycling rate at the divertor targets is high, the nitrogen redistributes within the slot leading to increased tungsten sputtering, and the range of injection rates resulting in tungsten mitigation becomes narrower.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Injection data analysis using material balance time for CO 2 storage capacity estimation in deep closed saline aquifers

Estimating the ultimate storage capacity of deep saline aquifers is important to address the formation potential to store the envisioned large volumes of CO 2 . Injection data (i.e. injection rate, bottomhole pressure, and cumulative injected volume of CO 2 ) are routinely recorded during storage operations. These data contain valuable information on the subsurface (e.g. the reservoir pore volume and the formation storage capacity) that can be extracted. In this paper, we present a two-step graphical technique to infer the pore volume and the ultimate storage capacity of closed saline aquifers by analyzing the available injection data. First, the pore volume is inferred through adapting the concept of the material balance time. Material balance time is an approximate superposition time function developed to interpret production data from oil and gas wells operating at variable pressure/rate conditions during the boundary-dominated flow period. Using material balance techniques, the ultimate storage capacity is then estimated through linear extrapolation of the average pressure trend to the maximum allowable pressure the formation can withstand. The average pressure is not available in practice, but is can be obtained from the injection data. Two approaches are presented in this study to calculate the average pressure; namely the rigorous and the approximate approaches. Unlike the rigorous approach, the approximate approach does not require a prior knowledge of some reservoir properties (e.g. relative permeability, absolute permeability, formation porosity and thickness) to calculate the average pressure. To investigate its potential and reliability in analyzing CO 2 injection data, the proposed technique is applied to four synthetic cases representing different well operating conditions. Results indicate that the approximate approach consistently overestimates the actual (simulated) storage capacity as compared to the rigorous approach. The agreement - between the inferred and the simulated reservoir pore volume, and between the analytical and numerical estimates of storage capacity - validates the potential application of the technique to CO 2 storage in closed saline aquifers. The technique is further substantiated through application to a field data set utilized from a commercial-scale geological storage (CGS) project. Finally, field data interpretation shows that the proposed technique can be utilized to identify the degree of hydraulic continuity and reservoir compartmentalization within a target formation by interpreting the corresponding pressure and rate responses.

02 PETROLEUM↗