A Low NO(x) Lean-Direct Injection, Multipoint Integrated Module Combuster Concept for Advanced Aircraft Gas Turbines

A low NO(x) emissions combustor has been demonstrated in flame-tube tests. A multipoint, lean-direct injection concept was used. Configurations were tested that had 25- and 36- fuel injectors in the size of a conventional single fuel injector. An integrated-module approach was used for the construction where chemically etched laminates, diffusion bonded together, combine the fuel injectors, air swirlers and fuel manifold into a single element. Test conditions were inlet temperatures up to 810 K, inlet pressures up to 2760 kPa, and flame temperatures up to 2100 K. A correlation was developed relating the NO(x) emissions with the inlet temperature, inlet pressure, fuel-air ratio and pressure drop. Assuming that 10 percent of the combustion air would be used for liner cooling and using a hypothetical engine cycle, the NO(x) emissions using the correlation from flame-tube tests were estimated to be less than 20 percent of the 1996 ICAO standard.

Tacina, Robert↗

A Hybrid Catalyst-Bonded Membrane Device for Electrochemical Carbon Monoxide Reduction at Different Relative Humidities

A hybrid catalyst-bonded membrane device using gaseous reactants for a carbon monoxide reduction (COR) reaction in the cathode chamber, an aqueous electrolyte for an oxygen evolution reaction (OER) in the anode chamber, and an anion exchange membrane (AEM) for product separation as modeled, constructed, and tested. The Cu electrocatalyst was electrodeposited onto gas diffusion layers (GDLs) and was directly bonded to AEM by mechanical pressing in the hybrid device. The impacts of relative humidity at the cathode inlet on the selectivity and activity of COR were investigated by computational modeling and experimental methods. At a relative humidity of 30%, the Cu-based catalyst in the hybrid device exhibited a total operating current density of 87 mA cm -2 with a -2.0 V vs Ag/AgCl reference electrode, a Faradaic efficiency (FE) for C 2 H 4 generation of 32.6%, and an FE for a liquid-based carbon product of 42.6%. Significant improvements in the partial current densities for COR were observed in relation to planar electrodes or flooded gas diffusion electrodes (GDEs). Finally in addition, a custom test bed was constructed to characterize the oxidation states of the Cu catalysts in real time along with product analysis though the backside of the GDLs via operando X-ray absorption (XAS) measurements.

30 DIRECT ENERGY CONVERSION↗

Computational Study of the CC3 Impeller and Vaneless Diffuser Experiment

Centrifugal compressors are compatible with the low exit corrected flows found in the high pressure compressor of turboshaft engines and may play an increasing role in turbofan engines as engine overall pressure ratios increase. Centrifugal compressor stages are difficult to model accurately with RANS CFD solvers. A computational study of the CC3 centrifugal impeller in its vaneless diffuser configuration was undertaken as part of an effort to understand potential causes of RANS CFD mis-prediction in these types of geometries. Three steady, periodic cases of the impeller and diffuser were modeled using the TURBO Parallel Version 4 code: 1) a k-epsilon turbulence model computation on a 6.8 million point grid using wall functions, 2) a k-epsilon turbulence model computation on a 14 million point grid integrating to the wall, and 3) a k-omega turbulence model computation on the 14 million point grid integrating to the wall. It was found that all three cases compared favorably to data from inlet to impeller trailing edge, but the k-epsilon and k-omega computations had disparate results beyond the trailing edge and into the vaneless diffuser. A large region of reversed flow was observed in the k-epsilon computations which extended from 70% to 100% span at the exit rating plane, whereas the k-omega computation had reversed flow from 95% to 100% span. Compared to experimental data at near-peak-efficiency, the reversed flow region in the k-epsilon case resulted in an under-prediction in adiabatic efficiency of 8.3 points, whereas the k-omega case was 1.2 points lower in efficiency.

Kulkarni, Sameer↗

Computational Study of the CC3 Impeller and Vaneless Diffuser Experiment

Centrifugal compressors are compatible with the low exit corrected flows found in the high pressure compressor of turboshaft engines and may play an increasing role in turbofan engines as engine overall pressure ratios increase. Centrifugal compressor stages are difficult to model accurately with RANS CFD solvers. A computational study of the CC3 centrifugal impeller in its vaneless diffuser configuration was undertaken as part of an effort to understand potential causes of RANS CFD mis-prediction in these types of geometries. Three steady, periodic cases of the impeller and diffuser were modeled using the TURBO Parallel Version 4 code: (1) a k-ε turbulence model computation on a 6.8 million point grid using wall functions, (2) a k-ε turbulence model computation on a 14 million point grid integrating to the wall, and (3) a k-ω turbulence model computation on the 14 million point grid integrating to the wall. It was found that all three cases compared favorably to data from inlet to impeller trailing edge, but the k-ε and k-ω computations had disparate results beyond the trailing edge and into the vaneless diffuser. A large region of reversed flow was observed in the k-ε computations which extended from 70 to 100 percent span at the exit rating plane, whereas the k-ω computation had reversed flow from 95 to 100 percent span. Compared to experimental data at near-peak-efficiency, the reversed flow region in the k-ε case resulted in an underprediction in adiabatic efficiency of 8.3 points, whereas the k-ω case was 1.2 points lower in efficiency.

Kulkarni, Sameer↗

Free-flight Performance of a Rocket-boosted, Air-launched 16-inch-diameter Ram-jet Engine at Mach Numbers up to 2.20

The investigation of air-launched ram-jet engines has been extended to include a study of models with a nominal design free-stream Mach number of 2.40. These models require auxiliary thrust in order to attain a flight speed at which the ram jet becomes self-accelerating. A rocket-boosting technique for providing this auxiliary thrust is described and time histories of two rocket-boosted ram-jet flights are presented. In one flight, the model attained a maximum Mach number of 2.20 before a fuel system failure resulted in the destruction of the engine. Performance data for this model are presented in terms of thrust and drag coefficients, diffuser pressure recovery, mass-flow ratio, combustion efficiency, specific fuel consumption, and over-all engine efficiency.

AIR INLETS - NOSE, ANNULAR↗

Hypersonic Magneto-Fluid-Dynamic Compression in Cylindrical Inlet

Hypersonic magneto-fluid-dynamic interaction has been successfully performed as a virtual leading-edge strake and a virtual cowl of a cylindrical inlet. In a side-by-side experimental and computational study, the magnitude of the induced compression was found to be depended on configuration and electrode placement. To better understand the interacting phenomenon the present investigation is focused on a direct current discharge at the leading edge of a cylindrical inlet for which validating experimental data is available. The present computational result is obtained by solving the magneto-fluid-dynamics equations at the low magnetic Reynolds number limit and using a nonequilibrium weakly ionized gas model based on the drift-diffusion theory. The numerical simulation provides a detailed description of the intriguing physics. After validation with experimental measurements, the computed results further quantify the effectiveness of a magnet-fluid-dynamic compression for a hypersonic cylindrical inlet. At a minuscule power input to a direct current surface discharge of 8.14 watts per square centimeter of electrode area produces an additional compression of 6.7 percent for a constant cross-section cylindrical inlet.

Shang, Joseph S.↗

Study of aerodynamic noise in low supersonic operation of an axial flow compressor

A study of compressor noise is presented, based upon supersonic, part-speed operation of a high hub/tip ratio compressor designed for spanwise uniformity of aerodynamic conditions, having straight cylindrical inlet and exit passages for acoustic simplicity. Acoustic spectra taken in the acoustically-treated inlet plenum, are presented for five operating points at each of two speeds, corresponding to relative rotor tip Mach numbers of about 1.01 and 1.12 (60 and 67 percent design speed). These spectra are analyzed for low and high frequency broadband noise, blade passage frequency noise, combination tone noise and "haystack' noise (a very broad peak somewhat below blade passage frequency, which is occasionally observed in engines and fan test rigs). These types of noise are related to diffusion factor, total pressure ratio, and relative rotor tip Mach number. Auxiliary measurements of fluctuating wall static pressures and schlieren photographs of upstream shocks in the inlet are also presented and related to the acoustic and performance data.

Arnoldi, R. A.↗

Modification of the Core Cooling System of TRIGA 2000 Reactor

To accomplish safety requirements, a set of actions has to be performed following the recommendations of the IAEA safety series 35 applied to research reactor. Such actions are considered in modernization of the old system, improving the core cooling system and safety evaluations. Due to the complexity of the process and the difficulty in putting the apparatus in the reactor core, analytical and experimental study on the determination of flow and temperature distribution in the whole coolant channel are difficult to be done. In the present work, a numerical study of flow and temperature distribution in the coolant channel of TRIGA 2000 has been carried out using CFD package. For this study, simulations were carried out on 3-D tested model. The model consists of the reactor tank, thermal and thermalizing column, reflector, rotary specimen rack, chimney, fuel element, primary pipe, diffuser, beam tube and a part of the core are constructed by 1.50 million unstructured tetrahedral cell elements. The results show that for the initial condition (116 fuel elements in the core) and for the inlet temperature of 24 deg. C and the primary velocity of 5.6 m/s, there no boiling phenomena occur in the coolant channel. Due to this result, it is now possible to improve the core cooling system of TRIGA 2000 reactor. Meanwhile, forced flow from the diffuser system only affected the flow pattern in the outside of chimney and put on a small effect to the fluid flow's velocity in the inside of chimney.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The choking pressure ratio of a critical flow venturi

The critical flow venturi has many important applications in the measurement and control of gas flow. In many of these applications, it is desirable to minimize the pressure loss required to maintain critical flow conditions. The performance of the venturi may be characterized by the ratio of outlet static pressure to inlet total pressure just sufficiently small to produce critical flow. This ratio is called choking pressure ratio. The optimization of diffusers for critical flow venturis is discussed and suggestions for designs practice are presented. Test results are given for six different diffuser configurations, and a comparison is made with data on 11 configurations from other investigators. It is shown that, for the small divergence angles considered, a simply defined diffuser effectiveness parameter is approximately independent of flow conditions and may be used to predict choking pressure ratio.

Hillbrath, H. S.↗

Preliminary aerodynamic calibration of the spinning mode synthesizer flow duct facility

Results of the initial aerodynamic calibration of the spinning mode synthesizer flow duct facility in the Aircraft Noise Reduction Laboratory are presented. The system is shown to be operable over an inlet Mach number range of zero to 0.6. Mach number profiles are presented at several axial stations along the duct. Diffuser performance is reviewed. Spatial and temporal variations are discussed.

Silcox, R. J.↗

Dynamics and control of hypersonic aeropropulsive/aeroelastic vehicles

The guidance and control of hypersonic vehicles is examined by studying the airframe/engine/structural-dynamic interactions of a generic vehicle with scramjet propulsion. The pitch-attitude dynamics are described for the vehicle configuration that can sustain hypersonic flight at near-orbital altitudes. These aerospacecraft have strong airframe/engine/elastic coupling in attitude dynamics and engine responses with static instability with respect to pitch. An integrated airframe-engine control system is presented for the control of the system's strong aeropropulsive/aeroelastic coupling. The control methodology utilizes feedback of measured/synthesized values of angle of attack, blended pitch rate, thrust, and combustor-inlet pressure. The multiinput/multioutput engine controller requires high-bandwidth actuation of the fuel-flow control and the effective diffuser ratio. The proposed control laws do not provide optimized performance in terms of pitch response suggesting that additional control crossfeeds and filtering is needed.

Schmidt, David K.↗

Hydrogen no-vent fill testing in a 1.2 cubic foot (34 liter) tank

Experimental results of no-vent fill testing with liquid hydrogen in a 1.2 cubic foot (34 liter) stainless steel tank are presented. More than 40 tests were performed with various liquid inlet temperatures, inlet flowrates, initial tank wall temperatures, and liquid injection techniques. Fill levels equal to or exceeding 90 percent by volume were achieved in 40 percent of the tests with the tank pressure limited to a maximum of 30 psia. Three liquid injection techniques were employed; top spray, upward pipe discharge, and bottom diffuser. Effects of each of the varied parameters on the tank pressure history and final fill level are evaluated. The final fill level is found to be indirectly proportional to the initial wall and inlet liquid temperatures and directly proportional to the inlet liquid flowrate. Furthermore, the top spray is the most efficient no-vent fill method of the three configurations examined. The success of this injection method is primarily due to condensation of the ullage vapor onto the incoming liquid droplets. Ullage condensation counteracts the tank pressure rise resulting from energy exchange between the fluid and the warmer tank walls, and ullage compression. Upward pipe discharge from the tank bottom is the next most efficient method. Fluid circulation induced by this fill configuration tends to diminish thermal stratification in the bulk liquid, thus enhancing condensation at the liquid gas interface.

Moran, Matthew E.↗

Three-dimensional compressible turbulent computations for a diffusing S-duct

The purpose of the present study was to evaluate the capability of the computational fluid dynamics computer program PARC3D to model flow in a typical diffusing subsonic S-duct, with strong secondary flows. This evaluation is needed to provide confidence in the analysis of aircraft inlets, which have similar geometries. The performance predictions include total pressure profiles, static pressures, velocity profiles, boundary layer data, and skin friction data. Flow in the S-duct is subsonic, and the boundary layers are assumed to be turbulent. The results for both H and O grid solutions, are compared with existing test data.

Smith, C. F.↗

Wind tunnel investigation of three axisymmetric cowls of different lengths at Mach numbers from 0.60 to 0.92

Pressure distributions on three inlets having different cowl lengths were obtained in the Langley 16-Foot Transonic Tunnel. The cowl diameter ratio (highlight diameter to maximum diameter) was 0.85 and the cowl length ratios (cowl length to maximum diameter) were 0.337, 0.439, and 0.547. The cowls had identical nondimensionalized (with respect to cowl length) external geometry and identical internal geometry. The internal contraction ratio (highlight area to throat area) was 1.250. The inlets had longitudinal rows of static pressure orifices on the top and bottom (external) surfaces and on the contraction (internal) and diffuser surfaces. The afterbody was cylindrical in shape, and its diameter was equal to the maximum diameter of the cowl. Depending on the cowl configuration and free-stream Mach number, the mass-flow ratio varied between 0.27 and 0.87 during the tests. Angle of attack varied from 0 to 4.1 deg at selected Mach numbers and mass-flow ratios, and the Reynolds number varied with the Mach number from 3.2x10(exp 6) to 4.2x10(exp 6) per foot.

Re, Richard J.↗

Hydrogen no-vent fill testing in a 34 liter (1.2 cubic foot) tank

Experimental results of no-vent fill testing with liquid hydrogen in a 34 liter stainless steel tank are presented. More than 40 tests were performed with various liquid inlet temperatures, inlet flowrates, initial tank wall temperatures, and liquid injection techniques. Maximum pressure within the receiver tank was limited to 0.207 MPa (30 psia), and fill levels equal to or exceeding 90 percent by volume were achieved in 40 percent of the tests. Three liquid injection techniques were employed; top spray, upward pipe discharge, and bottom diffuser. Effects of each of the various parameters on the tank pressure history and final fill level are evaluated. The final fill level is found to be indirectly proportional to the initial wall and inlet liquid temperatures and directly proportional to the inlet liquid flowrate. Furthermore, the top spray is the most efficient no-vent fill method of the three configurations examined. The success of this injection method is primarily due to condensation of the ullage vapor onto the incoming liquid droplets. Ullage condensation counteracts the tank pressure rise resulting from energy exchange between the fluid and the warmer tank walls and from ullage compression.

Moran, Matthew E.↗

Heat conduction controlled combustion for scramjet applications

The use of heat conduction flame generated in a premixed supersonic stream is discussed. It is shown that the flame is controlled initially by heat conduction and then by chemical reaction. Such a flame is shorter than the diffusion type of flame and therefore it requires a much shorter burner. The mixing is obtained by injecting the hydrogen in the inlet. Then the inlet can be cooled by film cooling.

Ferri, A.↗

Boundary layer bleed system study for a full-scale, mixed-compression inlet with 45 percent internal contraction

The results of an experimental bleed development study for a full-scale, Mach 2.5, axisymmetric, mixed-compression inlet were presented. The inlet was designed to satisfy the airflow requirements of the TF30-P-3 turbofan engine. Capabilities for porous bleed on the cowl surface and ram-scoop/flush-slot bleed on the centerbody were provided. A configuration with no bleed on the cowl achieved a minimum stable, diffuser exit, total pressure recovery of 0.894 with a centerbody-bleed mass flow ratio of 0.02. Configurations with cowl bleed had minimum stable recoveries as high as 0.900 but suffered range decrement penalties from the increased bleed mass flow removal. Limited inlet stability and unstart angle-of-attack data are presented.

Shaw, R. J.↗