Search NASA⌕ Search

SEARCH · Search NASA

Results for “Insertion device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

New proposed ITER divertor design using carbon insert on tungsten to mitigate ELMs and secondary radiation effects on nearby components

Abstract Building a successful device for the magnetic fusion energy production is a great challenge. ITER is an international project of the tokamak based magnetic fusion design being developed for the demonstration of the feasibility of thermonuclear technologies for future realization of successful commercial fusion energy. A key obstacle to a successful magnetic fusion energy production is however, the performance during abnormal events including plasma disruptions and edge-localized modes (ELMs). A credible reactor design must tolerate at least a few of these transient events without serious consequences such as melting of the structure. This paper investigates and compares the performance of the current ITER tokamak design during two types of transient events, i.e., ELMs occurring at normal operation and disruptions during abnormal operation. We simulated the divertor components response using our integrated 3D HEIGHTS package. The simulations include self-consistent modeling of the interaction of the released core plasma particles with the initial solid divertor material, energy deposition processes, vaporization of divertor material, secondary plasma formation and MHD evolution, incident core particles collisions and scattering from this dense secondary plasma, photon radiation of secondary plasma, and the resulting heat loads on nearby components. Our simulations showed that using a small carbon insert around the strike point can significantly reduce the overall expected damage on the tungsten dome structure, reflector plates, and prevent tungsten vaporization and its potential core plasma contamination.

47 OTHER INSTRUMENTATION↗

Flexible Hybrid Battery/Pseudocapacitor

Batteries keep devices working by utilizing high energy density, however, they can run down and take tens of minutes to hours to recharge. For rapid power delivery and recharging, high-power density devices, i.e., supercapacitors, are used. The electrochemical processes which occur in batteries and supercapacitors give rise to different charge-storage properties. In lithium ion (Li+) batteries, the insertion of Li+, which enables redox reactions in bulk electrode materials, is diffusion controlled and can be slow. Supercapacitor devices, also known as electrical double-layer capacitors (EDLCs) store charge by adsorption of electrolyte ions onto the surface of electrode materials. No redox reactions are necessary, so the response to changes in potential without diffusion limitations is rapid and leads to high power. However, the charge in EDLCs is confined to the surface, so the energy density is lower than that of batteries.

Tucker, Dennis S.↗

A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom. The PSDs were distributed on a 26 x 26 cm{sup 2} grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm. Each PSD was made of a 1 mm diameter by 3 mm long cylindrical polystyrene scintillating fiber coupled to a clear nonscintillating plastic optical fiber. All of the light signals emitted by the PSDs were read simultaneously with an optical system at a rate of one measurement per second. We characterized the performance of the optical system, the angular dependency of the device, and the perturbation of dose distributions caused by the hundreds of PSDs inserted into the phantom. We also evaluated the capacity of the system to monitor complex multileaf collimator (MLC) sequences such as those encountered in step-and-shoot intensity modulated radiation therapy (IMRT) plans. We compared our results with calculations performed by a treatment planning system and with measurements taken with a 2D ionization chamber array and with a radiochromic film. Results: The detector array that we developed allowed us to measure doses with an average precision of better than 1% for cumulated doses equal to or greater than 6.3 cGy. Our results showed that the dose distributions produced by the 6-MV photon beam are not perturbed (within {+-}1.1%) by the presence of the hundreds of PSDs located into the phantom. The results also showed that the variations in the beam incidences have little effect on the dose response of the device. For all incidences tested, the passing rates of the gamma tests between the 2D-PSDA and the treatment planning system were higher than 97.5% when the standard clinical tolerances of 3% or 3 mm were used. Excellent agreement was obtained between the doses measured and calculated when we used the 2D-PSDA for monitoring a MLC sequence from a step-and-shoot IMRT plan. Conclusions: We demonstrated the feasibility of using a large number of PSDs in a new 2D-PSDA for the dosimetry of MV energy photon beams in radiation therapy. The excellent precision, accuracy, and low angular dependence of the device indicate that such a prototype could potentially be used as a high-accuracy quality assurance tool for IMRT and arc therapy patient plan verification. The homogeneity and water-equivalence of the prototype we built suggest that this technology could be extended to multiple detection planes by arranging the fibers into more complex orientations, opening the possibility for 3D dosimetry with PSDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber loop quantum buffer for photonic qubits

Abstract We report a fiber loop quantum buffer based on a low-loss 2 × 2 switch and a unit delay made of a fiber delay line. We characterize the device by using a two-photon polarization entangled state in which one photon of the entangled photon pair is stored and retrieved at a repetition rate up to 78 kHz. The device, which enables integer multiples of a unit delay, can store the qubit state in a unit of fiber delay line up to 5.4 km and the number of loop round-trips up to 3. Furthermore, we configure the device with other active elements to realize integer multiplier and divider of a unit delay of a qubit. The quantum state tomography is performed on the retrieved photon and its entangled photon. We obtain a state fidelity > 94 % with a maximum storage time of 52 s with an insertion loss of 5.56 dB. To further characterize the storing and retrieving processes of the device, we perform entanglement-assisted quantum process tomography on the buffered qubit state. The process fidelity of the device is > 0.98. Our result implies that the device preserves the superposition and entanglement of a qubit state from a two-photon polarization-entangled state. This is a significant step towards facilitating applications in optical asynchronous transfer mode based quantum networks.

Fook Lee, Kim (ORCID:0000000290901640)↗

Tire deflation device

A tire deflation device includes (1) a component having a plurality of bores, (2) a plurality of spikes removably insertable into the plurality of bores and (3) a keeper within each among the plurality of bores, the keeper being configured to contact a sidewall surface of a spike among the plurality of spikes and to exert force upon the sidewall surface. In an embodiment, the tire deflation device includes (a) a component including a bore in a material, the bore including a receiving region, a sidewall surface and a base surface, (b) a channel extending from the sidewall surface into the material, (c) a keeper having a first section housed within the channel and a second section which extends past the sidewall surface into the receiving region, and (d) a spike removably insertable into the bore.

Barker, Stacey G↗

Underground pipe inspection device and method

A method and apparatus for inspecting the walls of an underground pipe from inside the pipe in which an inspection apparatus having a circular planar platform having a plurality of lever arms having one end pivotably attached to one side of the platform, having a pipe inspection device connected to an opposite end, and having a system for pivoting the lever arms is inserted into the underground pipe, with the inspection apparatus oriented with the planar platform disposed perpendicular to the pipe axis. The plurality of lever arms are pivoted toward the inside wall of the pipe, contacting the inside wall with each inspection device as the apparatus is conveyed along a length of the underground pipe.

47 OTHER INSTRUMENTATION↗

Hybrid tandem photovoltaic devices with a transparent conductive interconnecting recombination layer

Highlights: ► This work enhanced power conversion efficiency of the hybrid tandem solar cell from 1.0% to 2.6%. ► The interfacial series resistance of the tandem solar cell was eliminated by inserting ITO layer. ► This work shows the feasibility of the highly efficient hybrid tandem solar cells. -- Abstract: We demonstrate hybrid tandem photovoltaic devices with a transparent conductive interconnecting recombination layer. The series-connected hybrid tandem photovoltaic devices were developed by combining hydrogenated amorphous silicon (a-Si:H) and polymer-based organic photovoltaics (OPVs). In order to enhance the interfacial connection between the subcells, we employed highly transparent and conductive indium tin oxide (ITO) thin layer. By using the ITO interconnecting layer, the power conversion efficiency of the hybrid tandem solar cell was enhanced from 1.0% (V{sub OC} = 1.041 V, J{sub SC} = 2.97 mA/cm{sup 2}, FF = 32.3%) to 2.6% (V{sub OC} = 1.336 V, J{sub SC} = 4.65 mA/cm{sup 2}, FF = 41.98%) due to the eliminated interfacial series resistance.

36 MATERIALS SCIENCE↗

Gas chromatograph injection port protective device

To prevent samples containing foreign matter from poisoning the gas chromatographic columns, a pre-filter insertion is placed in the injection port. The packing becomes a variable reactant, for example, acids are removed by using an alkaline liquid.

Robertson, M. D.↗

A Novel Technique for Inferior Vena Cava Filter Extraction

Inferior vena cava (IVC) filters are used to protect against pulmonary embolism in high-risk patients. Whilst the insertion of retrievable IVC filters is gaining popularity, a proportion of such devices cannot be removed using standard techniques. We describe a novel approach for IVC filter removal that involves snaring the filter superiorly along with the use of flexible forceps or laser devices to dissect the filter struts from the caval wall. This technique has used to successfully treat three patients without complications in whom standard techniques failed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shear-horizontal surface acoustic wave phononic device with high density filling material for ultra-low power sensing applications

Finite element simulations of a phononic shear-horizontal surface acoustic wave (SAW) sensor based on ST 90°-X Quartz reveal a dramatic reduction in power consumption. The phononic sensor is realized by artificially structuring the delay path to form an acoustic meta-material comprised of a periodic microcavity array incorporating high-density materials such as tantalum or tungsten. Constructive interference of the scattered and secondary reflected waves at every microcavity interface leads to acoustic energy confinement in the high-density regions translating into reduced power loss. Tantalum filled cavities show the best performance while tungsten inclusions create a phononic bandgap. Based on our simulation results, SAW devices with tantalum filled microcavities were fabricated and shown to significantly decrease insertion loss. Our findings offer encouraging prospects for designing low power, highly sensitive portable biosensors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Repetition rate stabilization of an erbium-doped all-fiber laser via opto-mechanical control of the intracavity group velocity

We present a method for stabilizing the repetition rate of an erbium-doped all-fiber laser by inserting an electronic polarization controller (EPC) in the fiber laser cavity. The device exhibited good integration, low cost, and convenient operation. Such a repetition rate stabilization may facilitate an all-fiber laser comb system with high integration. The repetition rate was phase-locked to a Rb reference more than 72 h with a low feedback voltage applied to one channel of the EPC. The repetition rate was 74.6 MHz. The standard deviation and the repetition rate linewidth were 1.4 and 1.7 mHz, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of the perpendicular magnetic anisotropy, spin–orbit torque, and Dzyaloshinskii–Moriya interaction in the heavy metal/CoFeB bilayers with Ir 22 Mn 78 insertion

The perpendicular magnetic anisotropy (PMA), current-induced spin–orbit torques (SOTs), and Dzyaloshinskii–Moriya interaction (DMI) in the as-grown W or Ta/Ir 22 Mn 78 (IrMn)/CoFeB/MgO stacks with varying IrMn layer thicknesses were investigated. The in-plane magnetized W/CoFeB/MgO sample becomes perpendicularly magnetized after inserting the IrMn layer without the requirement of the annealing process. The effective magnetization fields 4π Meff show a nonmonotonic dependence on the IrMn layer thickness, which reaches the maximum in magnitude at a thickness of tIrMn = 0.75 nm. The SOT effective fields corresponding to damping-like and field-like torques decrease with the insertion layer thickness. Moreover, the variation of the IrMn layer thickness leads to the change of the DMI in magnitude and sign change from positive (favoring right-handed chirality) to negative (favoring left-handed chirality). The realization of changing the PMA, SOTs, and DMI by inserting the IrMn layer provides more flexibility in the design of spintronic devices.

Physics↗

Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model

Purpose: Endoluminal ultrasound may serve as a minimally invasive option for delivering thermal ablation to pancreatic tumors adjacent to the stomach or duodenum. The objective of this study was to explore the basic feasibility of this treatment strategy through the design, characterization, and evaluation of proof-of-concept endoluminal ultrasound applicators capable of placement in the gastrointestinal (GI) lumen for volumetric pancreas ablation under MR guidance. Methods: Two variants of the endoluminal applicator, each containing a distinct array of two independently powered transducers (10 × 10 mm 3.2 MHz planar; or 8 × 10 × 20 mm radius of curvature 3.3 MHz curvilinear geometries) at the distal end of a meter long flexible catheter assembly, were designed and fabricated. Transducers and circulatory water flow for acoustic coupling and luminal cooling were contained by a low-profile polyester balloon covering the transducer assembly fixture. Each applicator incorporated miniature spiral MR coils and mechanical features (guiding tips and hinges) to facilitate tracking and insertion through the GI tract under MRI guidance. Acoustic characterization of each device was performed using radiation force balance and hydrophone measurements. Device delivery into the upper GI tract, adjacent to the pancreas, and heating characteristics for treatment of pancreatic tissue were evaluated in MR-guided ex vivo and in vivo porcine experiments. MR guidance was utilized for anatomical target identification, tracking/positioning of the applicator, and MR temperature imaging (MRTI) for PRF-based multislice thermometry, implemented in the real-time RTHawk software environment. Results: Force balance and hydrophone measurements indicated efficiencies of 48.8% and 47.8% and −3 dB intensity beam-widths of 3.2 and 1.2 mm for the planar and curvilinear transducers, respectively. Ex vivo studies on whole-porcine carcasses revealed capabilities of producing ablative temperature rise (ΔT > 15 °C) contours in pancreatic tissue 4–40 mm long and 4–28 mm wide for the planar transducer applicator (1–13 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Curvilinear transducers produced more selective heating, with a narrower ΔT > 15 °C contour length and width of up to 1–24 mm and 2–7 mm, respectively (1–7 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Active tracking of the miniature spiral coils was achieved using a Hadamard encoding tracking sequence, enabling real-time determination of each coil’s coordinates and automated prescription of imaging planes for thermometry. In vivo MRTI-guided heating trials in three pigs demonstrated capability of ∼20 °C temperature elevation in pancreatic tissue at 2 cm depths from the applicator, with 5–7 W/cm{sup 2} applied intensity and 6–16 min sonication duration. Dimensions of thermal lesions in the pancreas ranged from 12 to 28 mm, 3 to 10 mm, and 5 to 10 mm in length, width, and depth, respectively, as verified through histological analysis of tissue sections. Multiple-baseline reconstruction and respiratory-gated acquisition were demonstrated to be effective strategies in suppressing motion artifacts for clear evolution of temperature profiles during MRTI in the in vivo studies. Conclusions: This study demonstrates the technical feasibility of generating volumetric ablation in pancreatic tissue using endoluminal ultrasound applicators positioned in the stomach lumen. MR guidance facilitates target identification, device tracking/positioning, and treatment monitoring through real-time multislice PRF-based thermometry.

60 APPLIED LIFE SCIENCES↗

Current Status of Thin Film (Ba,Sr)TiO3 Tunable Microwave Components for RF Communications

The performance of proof-of-concept ferroelectric microwave devices has been moving steadily closer to the level needed for satellite and other rf communications applications. This paper will review recent progress at NASA Glenn in developing thin film Ba(x)Sr(1-x)TiO3 tunable micro-wave components for these applications. Phase shifters for phased array antennas, tunable filters and tunable oscillators employing microstrip and coupled microstrip configurations will be presented. Tunabilities, maximum dielectric constants, and phase shifter parameters will be discussed (e.g., coupled microstrip phase shifters with phase shift over 200 deg at 18 GHz and a figure of merit of 74.3 deg/dB). Issues of post-annealing, Mn-doping and Ba(x)Sr(1-x) TiO3 growth on sapphire and alumina substrates will be covered. The challenges of incorporating these devices into larger systems, such as yield, variability in phase shift and insertion loss, and protective coatings will also be addressed.

VanKeuls, F. W.↗

Current Status of Thin Film (Ba,Sr) TiO3 Tunable Microwave Components for RF Communications

The performance of proof-of-concept ferroelectric microwave devices has been moving steadily closer to the level needed for satellite and other rf communications applications. This paper will review recent progress at NASA Glenn in developing thin film Ba(x)Sr(1-x)TiO3 tunable microwave components for these applications. Phase shifters for phased array antennas, tunable filters and tunable oscillators employing microstrip and coupled microstrip configurations will be presented. Tunabilities, maximum dielectric constants, and phase shifter parameters will be discussed (e.g., coupled microstrip phase shifters with phase shift over 200 deg. at 18 GHz and a figure of merit of 74.3 deg./dB). Issues of postannealing, Mn-doping and Ba(x)Sr(1-x)TiO3 growth on sapphire and alumina substrates will be covered. The challenges of incorporating these devices into larger systems, such as yield, variability in phase shift and insertion loss, and protective coatings will also be addressed.

VanKeuls, F. W.↗

Upset Recovery Human Factors

Accident and incident analyses as well as industry group concerns and recommendations have justified taking a second look at proficiency standards related to upset recovery training and performance. Quite a number of factors and theories have been suggested-- leading the NASA Aviation Safety Program to reconsider manual handling skills in highly automated aircraft particularly in conditions that can potentially lead to Loss of Control events. Our team of Subject Matter Experts (SMEs) first identified 76 Basic Recovery Skills that were important for effective crew response under five different anomaly conditions. In addition to manual handling skills, the skill set included knowledge and cognitive skills, as well as decision making and management skills. Advanced Recovery Skills were identified by combining skills, integrating with crew resource management skills, and developing heuristics for decision making.Using the Advanced Recovery Skill set, the SMEs then developed a generic process flow starting from the problem discovery phase (e.g., identifying an anomaly) through the decision making and management phase (e.g., assessing response options), through the recovery phase (e.g., controlling the aircraft). The generic process flow was refined by testing it against six additional scenarios. The next part of the project was to develop an approach for assessing and revising a generic training curriculum (we used an operators Advanced Qualification Program (AQP) as a framework). Although many of the Basic and Advanced Recovery Skills could be found in the Job Task Listing, they were not always structured or combined in the most effective way. Recommendations were developed for assessing relevant aspects of the Job Task Listing and Continuing Qualification curriculum so that the more comprehensive set of Upset Recovery skillsincluding Human Factors--could be trained and assessed in the most appropriate and effective context. The existing AQP methodology provides a natural way to insert targeted Upset Recovery skills into its system of proficiency objectives, training devices, training activities, and ultimately, into the event sets of a simulator training scenario.

AQP training↗

Distributed measurement of minimum and maximum in-situ stress in substrates

A system for performing distributed measurements of in-situ stress includes an expandable element with at least one fiber optic sensor. The expandable element can be positioned at various depths in a hole in a substrate. A pressurizing device expands (and contracts) the expandable element when the expandable element is inserted in the hole in the substrate to exert pressure on the hole wall. A pressure sensor provides a sensor output indicative of a pressure applied to the hole wall by the expandable element. The fiber optic sensor and an optical interrogator measure strain along a length of the sensor in a continuous, high spatial resolution manner Based on the measured strain and pressure sensor output, the system determines various properties of the substrate such as, minimum principal stress, maximum principal stress, and/or principal stress direction associated with one or more fractures in the substrate, as well as substrate modulus.

Ohanian, III, Osgar John↗

Borescope Device Takes Impressions In Ducts

Maneuverable device built around borescope equipped to make impression molds of welded joints in interior surfaces of ducts. Molds then examined to determine degress of mismatch in welds. Inserted in duct, and color-coded handles on ends of cables used to articulate head to maneuver around corners. Use of device fairly easy and requires little training.

Walter, Richard F.↗