Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inverter Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

grid↗

Ankle and hip postural strategies defined by joint torques

Previous studies have identified two discrete strategies for the control of posture in the sagittal plane based on EMG activations, body kinematics, and ground reaction forces. The ankle strategy was characterized by body sway resembling a single-segment-inverted pendulum and was elicited on flat support surfaces. In contrast, the hip strategy was characterized by body sway resembling a double-segment inverted pendulum divided at the hip and was elicited on short or compliant support surfaces. However, biomechanical optimization models have suggested that hip strategy should be observed in response to fast translations on a flat surface also, provided the feet are constrained to remain in contact with the floor and the knee is constrained to remain straight. The purpose of this study was to examine the experimental evidence for hip strategy in postural responses to backward translations of a flat support surface and to determine whether analyses of joint torques would provide evidence for two separate postural strategies. Normal subjects standing on a flat support surface were translated backward with a range of velocities from fast (55 cm/s) to slow (5 cm/s). EMG activations and joint kinematics showed pattern changes consistent with previous experimental descriptions of mixed hip and ankle strategy with increasing platform velocity. Joint torque analyses revealed the addition of a hip flexor torque to the ankle plantarflexor torque during fast translations. This finding indicates the addition of hip strategy to ankle strategy to produce a continuum of postural responses. Hip torque without accompanying ankle torque (pure hip strategy) was not observed. Although postural control strategies have previously been defined by how the body moves, we conclude that joint torques, which indicate how body movements are produced, are useful in defining postural control strategies. These results also illustrate how the biomechanics of the body can transform discrete control patterns into a continuum of postural corrections.

Non-NASA Center↗

The control of apical dominance: localization of the growth region of the Pharbitis nil shoot

The growing region of the upright Pharbitis nil shoot extends over a distance 13 cm basipetal to the shoot apex. When the shoot is inverted, ethylene production in this region is greatly enhanced whereas stem elongation is significantly inhibited. This growth region is ethylene-sensitive and the restriction of its growth by shoot inversion-induced ethylene may mediate the release of apical dominance.

NASA Discipline Plant Biology↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources: Preprint

This study addresses the compliance of Inverter-based Resources (IBRs) with the IEEE Std 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a comprehensive controller development framework. This framework caters to maintaining ride-trhough operation or implementing strategic disconnections in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

IEEE Std 2800↗

Peptide programming of supramolecular vinylidene fluoride ferroelectric phases

Ferroelectric structures have spontaneous macroscopic polarization that can be inverted using external electric fields and have potential applications including information storage, energy transduction, ultralow-power nanoelectronics and biomedical devices. These functions would benefit from nanoscale control of ferroelectric structure, the ability to switch polarization with lower applied fields (low coercive field) and biocompatibility. Soft ferroelectrics based on poly(vinylidene fluoride) (PVDF) have a thermodynamically unstable ferroelectric phase in the homopolymer, complex semi-crystalline structures, and high coercive fields. Here, in this work, we report on ferroelectric materials formed by water-soluble molecules containing only six VDF repeating units covalently conjugated to a tetrapeptide, with the propensity to assemble into the β-sheet structures that are ubiquitous in proteins. This led to the discovery of ribbon-shaped ferroelectric supramolecular assemblies that are thermodynamically stable with their long axes parallel to both the preferred hydrogen-bonding direction of β-sheets and the bistable polar axes of VDF hexamers. Relative to a commonly used ferroelectric copolymer, the biomolecular assemblies exhibit a coercive field that is two orders of magnitude lower, as the result of supramolecular dynamics, and a similar level of remnant polarization, despite having a peptide content of 49 wt%. Furthermore, the Curie temperature of the assemblies is about 40 °C higher than that of a copolymer containing a similar amount of VDF. This supramolecular system was created using a biologically inspired strategy that is attractive in terms of sustainability and that could lead to new functions for soft ferroelectrics.

36 MATERIALS SCIENCE↗

EMT data generation

The integration of inverter-based resources (IBRs) in power systems is accelerating, bringing with it significant benefits such as reduced greenhouse gas emissions, improved grid resilience, and increased energy independence. Despite these advantages, the widespread adoption of IBRs introduces several challenges, including issues related to grid stability, increased operational complexity, and the need for updated regulatory frameworks. To address these challenges, IEEE released Standard 2800 in 2022, which sets forth the necessary interconnection capabilities and performance criteria for IBRs connected to transmission and sub-transmission systems. This standard outlines the performance requirements to ensure the reliable integration of IBRs into the bulk power system. Furthermore, in 2023, the North American Electric Reliability Corporation (NERC) published a reliability guideline for electromagnetic transient (EMT) modeling of BPS-connected IBRs. This guideline provides recommendations for developing EMT model requirements, performing model quality checks, and implementing verification practices specifically for EMT models representing BPS-connected inverter-based resources in reliability studies conducted by transmission planners and planning coordinators. These standards and guidelines have a profound impact on EMT studies for transmission networks, influencing system stability analyses, grid recovery and resynchronization processes, fault ride-through evaluations, protection and coordination strategies, advanced control methodologies, and the inclusion of IBRs in transient models of transmission networks. As a result, the generation of EMT data is crucial for conducting various transient-based studies to understand the impact of IBRs. EMT data generation use cases serve as the basis for scenarios in event detection and identification use cases, providing comprehensive details about EMT data generation for transmission grids with inverter-based resources. These use cases supply sufficient training and validation datasets for subsequent EMT analysis algorithms.

Xia, Qianxue↗

Gravity-Feed Growth of Silicon Ribbon

In inverted Stepanov apparatus, silicon is melted in vee-shaped crucible that has long narrow slot at bottom of vee. Molten silicon flows from slot at a rate controlled by fluid pressure. As it emerges, it cools and solidifies to form a continuous ribbon. To eliminate surface-tension effects, crucible walls are made of a material that liquid silicon does not wet.

Cullen, G. W.↗

Data-driven Modeling for Grid Edge IBRs: A Digital Twin Perspective of User-Defined Models

Recent events in Odessa have brought attention to the challenges associated with the interaction between Inverter- Based Resources (IBRs) and the transmission and distribution system. The NERC event diagnosis report has highlighted sev- eral issues, emphasizing the need for continuous performance monitoring of these IBRs by system operators. Key areas of concern include the mismatch of control and protection perfor- mance of IBRs between the original equipment manufacturer (OEM)-provided models and field measurements. The inability to replicate the realistic response can result in incorrect reliability and resilience studies. In this paper, we developed an approach on how to emulate the behavior of an IBR using measurement data obtained for system operators to utilize in real-time and long- term planning. Two experiments are conducted in the phasor domain and electromagnetic transients (EMT) domain to emulate the behavior for grid forming and grid following inverters under various operating conditions and the effectiveness of the proposed model is demonstrated in terms of accuracy and ease of utilizing user-defined models (UDMs)

Mahapatra, Kaveri [BATTELLE (PACIFIC NW LAB)]↗

Supplementary Investigation in the Langley Free-Spinning Tunnel of a 1/20-Scale Model of the Douglas XF4D-1 Airplane Including Spin-Recovery Parachute Tests of the Model Loaded to Simulate the Douglas F5D-1 Airplane

A supplementary investigation has been conducted in the Langley 20-foot free-spinning tunnel of a l/20-scale model of the Douglas XF4D-1 airplane to determine the effect of only neutralizing the rudder for recovery from an inverted spin, and the effect of partial aileron deflection with the spin for recovery from an erect spin. An estimation of the size parachute required for satisfactory recovery from a spin with the model ballasted to represent the Douglas F5D-1 (formerly the Douglas XF4D-2) airplane was also made. Results of the original investigation on the XF4D-1 design are presented in NACA RM SL50K30a. The results indicated that satisfactory recoveries from inverted spins of the airplane should be obtained by rudder neutralization when the longitudinal stick position is neutral or forward. Recoveries from erect spins from the normal-spin control configuration should be satisfactory by full rudder reversal with simultaneous movement of the ailerons to two-thirds with the spin. For the parachute tests with the model loaded to represent the F5D-1 airplane, the tests indicated that a 16.7-foot-diameter hemispherical-tail parachute (drag coefficient of 1.082 based on the projected area) with a towline 20.0 feet long (full- scale values) should be satisfactory for an emergency spin-recovery device during demonstration spins of the airplane.

Klinar, Walter J.↗

Role of Inverter-Based Resources (IBRs) in Energizing Remote Generating Stations

The increasing integration of Inverter-Based Resources (IBRs) into the system has brought significant focus on their role in blackstart and restoration procedures. Their advantageous features, such as low startup power requirements, operational flexibility across a wide range of power factors, rapid controllability, and the ability to energize a network at lower voltage levels necessitate a reassessment of existing restoration protocols. This paper seeks to showcase how IBRs can utilize their grid-forming capabilities to provide power to a remote generating station through detailed EMT simulation studies using data collected from an existing portion of a network.

blackstart procedure↗

Investigation Of Prandtl-Ishlinskii Hysteresis Compensation for Deep Space Optical Communications Pointing Control

This paper studies the simulated performance of the Deep Space Optical Communication (DSOC) laser downlink pointing control system that has a pointing requirement at the sub-microradian scale. To achieve the required pointing precision, the DSOC Flight Laser Transceiver (FLT) point-ahead mirror (PAM) employs piezoelectric actuators, which are widely used in precision applications due to their high motion resolution, rapid response, and high output forces. However, a piezoelectric actuator's performance is often limited by nonlinearities in their response, most significantly hysteresis. To study the effect of hysteresis on our simulated pointing performance, an invertible hysteresis model is developed using the Classical Prantdl-Ishlinskii (CPI) method. The simulation includes models of DSOC hardware and electronic system components based on key parameters (bias, frequency response, noise), with the hysteresis modeled in the PAM piezo actuator dynamics. A Proportional-Integral controller provides feedback with measurements from two potential sources: strain gauge sensors or a photon-counting camera. To compensate for hysteresis behavior, a feedforward inverse CPI hysteresis model is implemented in the control system. Two CPI models are built using different sampling methods (uniform sampling and cosine spacing) and controller performance is compared. For the maximum command range of ±400 μrad at 1 mHz, results show that the feedforward combined with feedback control reduces output tracking error by 50% or 58% (to 0.20 or 0.38 μrad) compared to feedback control alone (from 0.40 or 0.90 μrad), corresponding to the uniform-sampled and cosine-sampled CPI models, respectively.

Marinello, Lindsey A.↗

BIL GRID-READY WIND: Reliable and Economical Grid Services Design, Implementation, and Demonstration at the Great Pathfinder Wind Power Plant

The GRID-READY WIND project aimed to demonstrate the ability of utility-scale wind power plants (WPPs) to deliver traditional and emerging grid services (GSs) in both grid-following (GFL) and grid-forming (GFM) modes through a centralized control framework, supplemented by local control adjustments at the wind turbine generator as needed. Throughout the project, the team offered recommendations on how the grid services demonstrated with WPPs could be applied to other inverter-based resources (IBRs), such as photovoltaic (PV) systems and battery energy storage systems (BESS), while considering the unique dynamics of these resources arising from their energy generation characteristics. The project sought to enhance the confidence of system operators (SOs) and planners in utilizing WPPs, alongside other IBRs such as PV plants and BESS, to provide essential grid services over extended periods under diverse operating conditions, thereby supporting their integration into the bulk power system.

17 WIND ENERGY↗

Steady-state and dynamic characteristics of a 20-kHz spacecraft power system - Control of harmonic resonance

A detailed computer simulation was used to illustrate the steady-state and dynamic operating characteristics of a 20-kHz resonant spacecraft power system. The simulated system consists of a parallel-connected set of DC-inductor resonant inverters (drivers), a 440-V cable, a node transformer, a 220-V cable, and a transformer-rectifier-filter (TRF) AC-to-DC receiver load. Also included in the system are a 1-kW 0.8-pf RL load and a double-LC filter connected at the receiving end of the 20-kHz AC system. The detailed computer simulation was used to illustrate the normal steady-state operating characteristics and the dynamic system performance following, for example, TRF startup. It is shown that without any filtering the given system exhibits harmonic resonances due to an interaction between the switching of the source and/or load converters and the AC system. However, the double-LC filter at the receiving-end of the AC system and harmonic traps connected in series with each of the drivers significantly reduce the harmonic distortion of the 20-kHz bus voltage. Significant additional improvement in the waveform quality can be achieved by including a double-LC filter with each driver.

Wasynczuk, O.↗

Description of A 2.3 kW power transformer for space applications

The paper describes the principal features and special testing of a high-frequency high-power low-specific-weight (0.57 kg/kW) 2.3-kW electronic power transformer developed for space applications. The transformer is operated in a series resonant inverter supplying beam power to a 30-cm mercury ion thruster. High efficiency (above 98.5%) is obtained through careful detailed design. A number of unique heat removal techniques are discussed which control the winding temperature using only the available conductive cooling.

Hansen, I.↗

Modeling and analysis of several classes of self-oscillating inverters. I - State-plane representations. II - Model extension, classification, and duality relationships

The present investigation is concerned with an important class of power conditioning networks, taking into account self-oscillating dc-to-square-wave transistor inverters. The considered circuits are widely used both as the principal power converting and processing means in many systems and as low-power analog-to-discrete-time converters for controlling the switching of the output-stage semiconductors in a variety of power conditioning systems. Aspects of piecewise-linear modeling are discussed, taking into consideration component models, and an equivalent-circuit model. Questions of singular point analysis and state plane representation are also investigated, giving attention to limit cycles, starting circuits, the region of attraction, a hard oscillator, and a soft oscillator.

Lee, F. C. Y.↗

Integrated Hydrogen Energy System Testing/Validation: Cooperative Research and Development Final Report, CRADA Number CRD-21-18272

Through the ARIES platform, this proposed project aims to bridge a gap and utilize the power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments and create open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid forming fuel cell inverters.

08 HYDROGEN↗

Definition study for photovoltaic residential prototype system

A site evaluation was performed to assess the relative merits of different regions of the country in terms of the suitability for experimental photovoltaic powered residences. Eight sites were selected based on evaluation criteria which included population, photovoltaic systems performance and the cost of electrical energy. A parametric sensitivity analysis was performed for four selected site locations. Analytical models were developed for four different power system implementation approaches. Using the model which represents a direct (or float) charge system implementation the performance sensitivity to the following parameter variations is reported: (1) solar roof slope angle; (2) ratio of the number of series cells in the solar array to the number of series cells in the lead-acid battery; and (3) battery size. For a Cleveland site location, a system with no on site energy storage and with a maximum power tracking inverter which feeds back excess power to the utility was shown to have 19 percent greater net system output than the second place system. The experiment test plan is described. The load control and data acquisition system and the data display panel for the residence are discussed.

Shepard, N. F.↗