Search NASA⌕ Search

SEARCH · Search NASA

Results for “LABORATORY EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Life Sciences Laboratories for the Shuttle/Spacelab

Space Shuttle and Spacelab missions will provide scientists with their first opportunity to participate directly in research in space for all scientific disciplines, particularly the Life Sciences. Preparations are already underway to ensure the success of these missions. The paper summarizes the results of the 1975 NASA-funded Life Sciences Laboratories definition study which defined several long-range life sciences research options and the laboratory designs necessary to accomplish high-priority life sciences research. The implications and impacts of Spacelab design and development on the life sciences missions are discussed. An approach is presented based upon the development of a general-purposs laboratory capability and an inventory of common operational research equipment for conducting life sciences research. Several life sciences laboratories and their capabilities are described to demonstrate the systems potentially available to the experimenter for conducting biological and medical research.

Schulte, L. O.↗

Laboratory demonstration of a multi-sensor unattended cylinder verification station for uranium enrichment plant safeguards

The objective of safeguards is the timely detection of the diversion of a significant quantity of nuclear materials, and safeguarding uranium enrichment plants is especially important in preventing the spread of nuclear weapons. The IAEA’s proposed Unattended Cylinder Verification Station (UCVS) for UF 6 cylinder verification would combine the operator’s accountancy scale with a nondestructive assay system such as the Passive Neutron Enrichment Meter (PNEM) and cylinder identification and surveillance systems. In this project, we built a laboratory-scale UCVS and demonstrated its capabilities using mock UF 6 cylinders. We developed a signal processing algorithm to automate the data collection and processing from four continuous, unattended sensors. The laboratory demonstration of the system showed that the software could successfully identify cylinders, snip sensor data at the appropriate points in time, determine the relevant characteristics of the cylinder contents, check for consistency among sensors, and output the cylinder data to a file. This paper describes the equipment, algorithm and software development, laboratory demonstration, and recommendations for a full-scale UCVS.

42 ENGINEERING↗

Development of an Improved Process for Installation Projects of High Technology Manufacturing Equipment

High technology manufacturing equipment is utilized at Los Alamos National Laboratory (LANL) to support nuclear missions. This is undertaken from concept initiation where equipment is designed and then taken through several review phases, working closely with system engineers (SEs) responsible for each of the affected systems or involved disciplines (from gasses to HVAC to structural, etc.). After the design is finalized it moves to procurement and custom fabrication of the equipment and equipment installation, including all of the paperwork involved. Not only are the engineering and manufacturing aspects important, but also the scheduling, financial forecasting, and planning portions that take place initially and are sometimes modified as the project progresses should requirements, changes or additions become necessary. The process required to complete a project of this type, including equipment installation, is unique and involves numerous steps to complete. These processes can be improved and recent work on the Direct Current Arc (DC Arc) Glovebox Design, Fabrication and Installation Project provides an opportunity to identify some important lessons learned (LL) that can be implemented in the future for continued project improvement and success.

42 ENGINEERING↗

Radio frequency interference at Jodrell Bank Observatory within the protected 21 cm band

Radio frequency interference (RFI) will provide one of the most difficult challenges to systematic Searches for Extraterrestrial Intelligence (SETI) at microwave frequencies. The SETI-specific equipment is being optimized for the detection of signals generated by a technology rather than those generated by natural processes in the universe. If this equipment performs as expected, then it will inevitably detect many signals originating from terrestrial technology. If these terrestrial signals are too numerous and/or strong, the equipment will effectively be blinded to the (presumably) weaker extraterrestrial signals being sought. It is very difficult to assess how much of a problem RFI will actually represent to future observations, without employing the equipment and beginning the search. In 1983 a very high resolution spectrometer was placed at the Nuffield Radio Astronomy Laboratories at Jodrell Bank, England. This equipment permitted an investigation of the interference environment at Jodrell Bank, at that epoch, and at frequencies within the 21 cm band. This band was chosen because it has long been "protected" by international agreement; no transmitters should have been operating at those frequencies. The data collected at Jodrell Bank were expected to serve as a "best case" interference scenario and provide the minimum design requirements for SETI equipment that must function in the real and noisy environment. This paper describes the data collection and analysis along with some preliminary conclusions concerning the nature of the interference environment at Jodrell Bank.

NASA Discipline Number 52-60↗

Environmental Barrier Coatings for Ceramic Matrix Composites - An Overview

SiC/SiC Ceramic Matrix Composites (CMCs) are increasingly being considered as structural materials for advanced power generation equipment because of their light weight, higher temperature capability, and oxidation resistance. Limitations of SiC/SiC CMCs include surface recession and component cracking and associated chemical changes in the CMC. The solutions pursued to improve the life of SiC/SiC CMCs include the incorporation of coating systems that provide surface protection, which has become known as an Environmental Barrier Coating (EBC). The development of EBCs for the protection of gas turbine hot section CMC components was a continuation of coating development work for corrosion protection of silicon-based monolithics. Work on EBC development for SiC/SiC CMCs has been ongoing at several national laboratories and the original gas turbine equipment manufacturers. The work includes extensive laboratory, rig and engine testing, including testing of EBC coated SiC/SiC CMCs in actual field applications. Another EBC degradation issue which is especially critical for CMC components used in aircraft engines is the degradation from glassy deposits of calcium-magnesium-aluminosilicate (CMAS) with other minor oxides. This paper addresses the need for and properties of external coatings on SiC/SiC CMCs to extend their useful life in service and the retention of their properties.

EBC↗

STS-112 Flight Day 5 Highlights

On this fifth day of the STS-112 mission, the crewmembers Atlantis will begin transferring equipment and supplies to the orbiting laboratory. The crew reviews procedures for Saturday's spacewalk. Mission Specialists, Dave Wolf and Piers Sellers will prepare the tools and other equipment for use during Saturday's spacewalk. The spacewalkers reverse positions for most of the EVA, with Sellers riding the arm and Wolf free-floating while tethered to the station. They will attach umbilicals, install a second camera, install spool positioning devices to quickly disconnect fittings on ammonia lines and release radiator beam launch locks. The crewmembers will move a number of scientific experiments back and forth between the vehicles to return completed experiments to Earth and deploy new experiments at the station. One experiment transferred includes a set of liver cell tissue samples from an experiment studying the function of human liver cells in micro-gravity experiments were moved from the station onto the shuttle for return to Earth. Payload experiments such as Marshall Space Flight Center's protein crystals in micro-gravity experiments were moved to and from the station.

Source record↗

Maximizing Efficiency and Quality: Leveraging Automated Testing for Laboratory Commissioning

The traditional commissioning process uses sampling to select equipment for functional acceptance testing when large quantities of equipment are present. Although this approach is generally effective in identifying wide-spread issues, it has several shortcomings: it fails to evaluate equipment not included in the sample, provides only a one-time validation of equipment operation, and the standard documentation is a simple checklist of pass/fail questions. During the construction and commissioning process of the new Research and Innovation Laboratory (RAIL) in Golden, CO, the National Renewable Energy Laboratory team engaged Group14 Engineering to implement a Connected Commissioning process using fault detection and diagnostic software for automated functional acceptance testing. This presentation highlights the advantages offered by automated functional testing in this critical laboratory setting: (1) sampling 100% of BAS-connected equipment during functional testing, (2) testing results backed by data beyond the traditional pass/fail checklist, and (3) an automated test process that can be regularly executed by the building management team for ongoing commissioning throughout the life of the building. The presentation will also cover technical challenges associated with Connected Commissioning and the important conversations with key stakeholders that need to occur well before functional acceptance testing in order to successfully implement the automated testing processes.

automated testing↗

Technical Assistance for Characterization Studies of Personal Protection Equipment (PPE) (Final CTAP Report)

Sandia National Laboratories (SNL) conducted an independent assessment of three different certified N95 respirators for the State of New Mexico Department of Homeland Security and Emergency Management. The testing conducted under this effort mimicked traditional NIOSH certification testing methodologies, where possible (NIOSH 2019). This included the use of a commercially available off-the-shelf (COTS) instrument typically used in industry for N95 respirator certification (ATI 2018). The COTS system, an Air Techniques International 100Xs automated filter tester, was used for all the testing reported in this document. It is important to note that SNL is NOT a certification laboratory, and all quantitative results are for informational purposes only. Additional technical information of N95-related efforts conducted by this team may be found in: Omana et al. (2020a), Omana et al. (2020b), Celina et al. (2020)

42 ENGINEERING↗

Analytical Techniques for Retrieval of Atmospheric Composition with the Quadrupole Mass Spectrometer of the Sample Analysis at Mars Instrument Suite on Mars Science Laboratory

The Sample Analysis at Mars (SAM) instrument suite is the largest scientific payload on the Mars Science Laboratory (MSL) Curiosity rover, which landed in Mars׳ Gale Crater in August 2012. As a miniature geochemical laboratory, SAM is well-equipped to address multiple aspects of MSL׳s primary science goal, characterizing the potential past or present habitability of Gale Crater. Atmospheric measurements support this goal through compositional investigations relevant to martian climate evolution. SAM instruments include a quadrupole mass spectrometer, a tunable laser spectrometer, and a gas chromatograph that are used to analyze martian atmospheric gases as well as volatiles released by pyrolysis of solid surface materials (Mahaffy et al., 2012). This report presents analytical methods for retrieving the chemical and isotopic composition of Mars׳ atmosphere from measurements obtained with SAM׳s quadrupole mass spectrometer. It provides empirical calibration constants for computing volume mixing ratios of the most abundant atmospheric species and analytical functions to correct for instrument artifacts and to characterize measurement uncertainties. Finally, we discuss differences in volume mixing ratios of the martian atmosphere as determined by SAM (Mahaffy et al., 2013) and Viking (Owen et al., 1977, Oyama and Berdahl, 1977) from an analytical perspective. Although the focus of this paper is atmospheric observations, much of the material concerning corrections for instrumental effects also applies to reduction of data acquired with SAM from analysis of solid samples.

quadropole mass spectometer↗

Initial SAM Calibration Gas Experiments on Mars: Quadrupole Mass Spectrometer Results and Implications

The Sample Analysis at Mars (SAM) instrument suite of the Mars Science Laboratory (MSL) Curiosity rover is equipped to analyze both martian atmospheric gases and volatiles released by pyrolysis of solid surface materials, with target measurements including chemical and isotopic composition (Mahaffy et al., 2012). To facilitate assessment of instrument performance and validation of results obtained on Mars, SAM houses a calibration cell containing CO2, Ar, N2, Xe, and several fluorinated hydrocarbon compounds (Franz et al., 2014; Mahaffy et al., 2012). This report describes the first two experiments utilizing this calibration cell on Mars and gives results from analysis of data acquired with the SAM Quadrupole Mass Spectrometer (QMS). These data support the accuracy of isotope ratios obtained with the QMS (Conrad et al., 2016; Mahaffy et al., 2013) and provide ground-truth for reassessment of analytical constants required for atmospheric measurements, which were reported in previous contributions (Franz et al., 2015, 2014). The most significant implication of the QMS data involves reinterpretation of pre-launch contamination previously believed to affect only CO abundance measurements (Franz et al., 2015) to affect N2 abundances, as well. The corresponding adjustment to the N2 calibration constant presented here brings the atmospheric volume mixing ratios for Ar and N2 retrieved by SAM into closer agreement with those reported by the Viking mission (Owen et al., 1977; Oyama and Berdahl, 1977).

Sample Analysis at Mars Investigation↗

NASA DC-8 airborne research laboratory

Since the summer of 1987, NASA Ames Research Center has been operating a DC-8 equipped with CFM 56 engines as a flying research laboratory. In this relatively short time, the DC-8, with its tremendous capabilities, has made significant contributions to numerous scientific fields. Capable of staying aloft for over 12 hours, the DC-8 has flown directly over both the North and South Poles, gathering data relating to the ozone hole. Operating from a few thousand feet to over 40,000 feet above sea level the interchangeable payload capability of the DC-8 has made it a versatile scientific tool. The DC-8 also plays a vital role in the development of new satellite-borne sensors as very often those sensors are test-flown on the DC-8 before they are launched into space. The tremendous range and instrument carrying capability make the DC-8 an ideal flying laboratory. A few of the programs the DC-8 has participated in as well as a sampling of the instruments carried are outlined.

Degreef, Leo H.↗

Retrofitting stoves with forced jets of primary air improves speed, emissions, and efficiency: Evidence from six types of biomass cookstoves

Incorporating jets of forced air into biomass cookstove combustion has been shown to potentially decrease harmful emissions, leading to a variety of designs in recent years. These have shown mixed success in terms of real-world performance, usability, and durability. The Jet-Flame forced draft retrofit accessory was recently developed to implement forced jets of primary air at a low cost into a wide range of types of cookstoves using a small 1.5-W fan housed in a low-cost cast iron body to be inserted beneath the fuel bed of a biomass cooking fire. This research sought to quantify the potential efficiency and emissions performance impacts of the Jet-Flame when installed in six different types of biomass cookstoves (three open or shielded fires and three rocket stoves) versus the natural draft performance of each. The effect of the operating fan voltage was also measured. A series of tests following a modified ISO 19867-1:2018 protocol were performed in the laboratory using the Aprovecho Laboratory Emissions Measurement System (LEMS) equipped with additional oxygen and temperature sensors. Results for each stove carefully tended with a single layer of sticks showed that the global average PM 2.5 reduction with the Jet-Flame was 89 % relative to the natural draft cases, with larger relative improvements seen in the most rudimentary stoves. CO was reduced by a global average of 74 %, reaching tier 4 or 5 for all stoves. Thermal efficiency was also improved by 34 % when calculated without taking into account the energy content of the remaining char (or 21 % with char), illustrating the value of burning char to provide cooking energy rather than leaving it unburned in the combustion chamber as is common in many natural draft stoves. Time to boil was also reduced by 8 %. In addition, adjusting the voltage of the jet-flame assisted in modulating firepower, improving the usability of the stove. These results indicate a strong potential for the Jet-Flame to help reduce emissions and fuel consumption in a wide range of cookstove designs at a relatively low cost or need for changes in behavior, fuel, or cooking device. The unit also provides enhanced usability in terms of ease of startup, cooking speed, low PM emissions at high power, and burning char. Additional studies are needed to measure performance in the field and under a variety of operational conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sustainable conversion of biomass to rationally designed lithium-ion battery graphite

The carbon net negative conversion of bio-char, the low value byproduct of pyrolysis bio-oil production from biomass, to high value, very high purity, highly crystalline flake graphite agglomerates with rationally designed shape and size tailored for lithium-ion battery energy storage material is reported. The process is highly efficient, 0.41 g/Wh; the energy content of its co-product of the process, bio-oil, exceeds that needed to power the process. It is shown that the shape of the starting material is retained during the transformation, allowing the ultimate morphology of the graphite agglomerates to be engineered from relatively malleable biomass. In contrast to commercial graphite production, the process can be performed at small scale with low equipment costs, enabling individual research laboratories to produce Li-ion grade graphite with customizable shape, size and porosity for Si/graphite composite and other graphite involved anodes. The mechanism of the graphitization of bio-char, a “non-graphitizable” carbon, is explored, suggesting the molten metal catalyst is absorbed into the pore structure, transported through and transforming the largely immobile biochar. Finally, the transformation of biomass to rationally designed graphite morphologies with Li-ion anode performance that closely mimic commercial shaped graphite is demonstrated.

09 BIOMASS FUELS↗

Dealing with the size-of-source effect in the calibration of direct-reading radiation thermometer

The majority of general-purpose low-temperature handheld radiation thermometers are severely affected by the size-of-source effect (SSE). Calibration of these instruments is pointless unless the SSE is accounted for in the calibration process. Traditional SSE measurement techniques, however, are costly and time consuming, and because the instruments are direct-reading in temperature, traditional SSE results are not easily interpretable, particularly by the general user. This paper describes a simplified method for measuring the SSE, suitable for second-tier calibration laboratories and requiring no additional equipment, and proposes a means of reporting SSE results on a calibration certificate that should be easily understood by the non-specialist user.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CROSSFLOW FILTRATION: EM-31, WP-2.3.6

In the interest of accelerating waste treatment processing, the DOE has funded studies to better understand filtration with the goal of improving filter fluxes in existing crossflow equipment. The Savannah River National Laboratory (SRNL) performed some of those studies, with a focus on start-up techniques, filter cake development, the application of filter aids (cake forming solid precoats), and body feeds (flux enhancing polymers). This paper discusses the progress of those filter studies. Crossflow filtration is a key process step in many operating and planned waste treatment facilities to separate undissolved solids from supernate solutions. This separation technology generally has the advantage of self-cleaning through the action of wall shear stress created by the flow of waste slurry through the filter tubes. However, the ability of filter wall self-cleaning depends on the slurry being filtered. Many of the alkaline radioactive wastes are extremely challenging to filtration, e.g., those containing compounds of aluminum and iron, which have particles whose size and morphology reduce permeability. Unfortunately, low filter flux can be a bottleneck in waste processing facilities such as the Savannah River Integrated Salt Disposition Process and the Hanford Waste Treatment Plant. Any improvement to the filtration rate would lead directly to increased throughput of the entire process. To date increased rates are generally realized by either increasing the crossflow filter feed flow rate, limited by pump capacity, or by increasing filter surface area, limited by space and increasing the required pump load. SRNL set up both dead-end and crossflow filter tests to better understand filter performance based on filter media structure, flow conditions, filter cleaning, and several different types of filter aids and body feeds. Using non-radioactive simulated wastes, both chemically and physically similar to the actual radioactive wastes, the authors performed several tests to evaluate methods to improve filter performance. With the proper use of filter flow conditions and filter enhancers, filter flow rates can be increased over rates currently realized today. Experiments that use non-radioactive simulants for actual waste always carry the inherent risk of not eliciting prototypic results; however, they will assist in focusing the scope needed to minimize radioactive testing and thus maximize safety. To that end this investigation has determined: (1) Waste simulant SB6 was found to be more challenging to filtration than a SRS Tank 8F simulant; (2) Higher solids concentration presents a greater challenge to filtration; (3) Filter cake is something that should be properly developed in initial filter operation; (4) Backpulsing is not necessary to maintain a good filter flux with salt wastes; (5) Scouring a filter without cleaning will lead to improved filter performance; (6) The presence of a filter cake can improve the solids separation by an order of magnitude as determined by turbidity; (7) A well developed cake with periodic scouring may allow a good filter flux to be maintained for long periods of time; and (8) Filtrate flux decline is reversible when the concentration of the filtering slurry drops and the filter is scoured.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Carbon Characterization Laboratory Readiness to Receive Irradiated Graphite Samples

The Carbon Characterization Laboratory (CCL) is located in Labs C19 and C20 of the Idaho National Laboratory Research Center. The CCL was established under the Next Generation Nuclear Plant Project to support graphite and ceramic composite research and development activities. The research conducted in this laboratory will support the Advanced Graphite Creep experiments—a major series of material irradiation experiments within the Next Generation Nuclear Plant Graphite program. The CCL is designed to characterize and test low activated irradiated materials such as high purity graphite, carbon-carbon composites, silicon-carbide composite, and ceramic materials. The laboratory is fully capable of characterizing material properties for both irradiated and nonirradiated materials. Major infrastructural modifications were undertaken to support this new radiological facility at Idaho National Laboratory. Facility modifications are complete, equipment has been installed, radiological controls and operating procedures have been established and work management documents have been created to place the CCL in readiness to receive irradiated graphite samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗