Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Assessment of User Home Location Geoinference Methods

This study presents an assessment of multiple approaches to determine the home and/or other important locations to a Twitter user. In this study, we present a unique approach to the problem of geotagged data sparsity in social media when performing geoinferencing tasks. Given the sparsity of explicitly geotagged Twitter data, the ability to perform accurate and reliable user geolocation from a limited number of geotagged posts has proven to be quite useful. In our survey, we have achieved accuracy rates of over 86% in matching Twitter user profile locations with their inferred home locations derived from geotagged posts.

Harrison, Joshua J.↗

Formal methods approach to the charging facility location problem for battery electric vehicles

Battery electric vehicles (BEVs) are becoming more prevalent as improvements in battery technology and energy management continue to be made. As the number of electric vehicles grows, the demand for fast-charging stations is expected to increase dramatically. Thus, building new charging station infrastructure efficiently will be key to reducing upfront costs while meeting consumer demands. In this work, we propose a method for choosing a set of charging station locations that are optimized based on a set of given common vehicle demand points. As part of this solution, we also offer a novel abstraction of the road network on which energy-efficient paths that account for charge-time delays may be found. The current algorithm chooses the optimal charging locations for a single agent which has a route objective specified using temporal logic. To demonstrate the proposed method, the running example shows how a charging station could be chosen for an electric delivery vehicle. Simulations were run on sample road networks with a given set of demand points to service and potential charging station locations to compare. The method is shown to successfully rank potential charging stations in terms of their expected average charging time cost.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using Map Matching for DeIdentification of Connected Vehicle Locations

In this paper we introduce a location deidentification procedure that uses road network structure to protect against certain types of inference-based attacks. Our target is large databases containing vehicle locations. Previous anonymization approaches are inappropriate because location generalization and perturbation of geopositions could negatively affect development of safety-critical applications that require precise position information. Furthermore, k-anonymity-based clustering approaches would lead to significant data suppression. Our algorithm attempts to balance privacy protection and data utility, while protecting against re-identification attacks. Our data is from the first connected vehicle model deployment in the United States.

97 MATHEMATICS AND COMPUTING↗

An Instrument Design for the Accurate Determination of the Electron Beam Location in the Linac Coherent Light Source Undulator

The Linac Coherent Light Source (LCLS), currently under design, requires accurate alignment between the electron beam and each undulator's magnetic centerline. A beam finder wire (BFW) instrument has been developed to provide beam location information that is used to move the undulators to their appropriate positions. A BFW instrument is mounted at each of the 33 magnets in the undulator section. Beam detection is achieved by electrons impacting two carbon fiber wires and then sensing the downstream radiation. The wires are mounted vertically and horizontally on a wire card similar to that of a traditional wire scanner instrument. The development of the BFW presents several design challenges due to the need for high accuracy of the wires locations and the need for removal of the wires during actual operation of the LCLS (30 microns repeatability is required for the wire locations). In this paper, we present the technical specification, design criteria, mechanical design, and results from prototype tests for the BFW.

43 PARTICLE ACCELERATORS↗

Locating PHEV exchange stations in V2G

Plug-in hybrid electric vehicle (PREV) is an environment friendly modem transportation method and has been rapidly penetrate the transportation system. Renewable energy is another contributor to clean power but the associated intermittence increases the uncertainty in power generation. As a foreseen benefit of a vchicle-to-grid (V2G) system, PREV supporting infrastructures like battery exchange stations can provide battery service to PREV customers as well as being plugged into a power grid as energy sources and stabilizer. The locations of exchange stations are important for these two objectives under constraints from both ,transportation system and power grid. To model this location problem and to understand and analyze the benefit of a V2G system, we develop a two-stage stochastic program to optimally locate the stations prior to the realizations of battery demands, loads, and generation capacity of renewable power sources. Based on this model, we use two data sets to construct the V2G systems and test the benefit and the performance of these systems.

25 ENERGY STORAGE↗

Distributed Fiber Optic Sensing to Identify Locations of Resistive Transitions in REBCO Conductors and Magnets

High-temperature superconductors such as REBa 2 Cu 3 O 7-x (REBCO, RE = rare earth) can generate strong magnetic fields that are promising for applications in particle accelerators and compact fusion reactors. Traditionally, voltage taps are installed in superconducting magnets to measure the voltage signals due to resistive transitions. The voltage-tap-based diagnostics is important for the development of magnet technology as it can help pinpoint the locations in the magnet windings that limit the magnet performance. The architecture of the multi-tape REBCO cable such as CORC wires, however, makes it difficult to apply the voltage-tap-based diagnostics to identify the locations of resistive transitions. Distributed fiber optic sensing (DFOS) has the potential to address this issue. In this paper, we report the measurements of thermal strain along a CORC wire based on optical frequency domain reflectometry with a maximum spatial resolution of 0.65 mm and a temporal resolution of 10 Hz. The optical fiber is co-wound with the CORC wire that is epoxy impregnated. During the test, current was increased until a resistive transition occurred in the conductor. The spectrum shift of the reflected light along the fiber was recorded. The results suggested that with proper thermal isolation from the cryogen, DFOS can be used to identify the locations of resistive transitions in CORC wires and magnets. In conclusion, the results will allow a better understanding of the causes of resistive transitions in REBCO conductors and magnets, which will help improve the REBCO magnet technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening

A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed study could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.

14 SOLAR ENERGY↗

Uncertainty Quantification of Capacitor Switching Transient Location using Machine Learning

Identification of capacitor switching transient location provides valuable insight into the state of the associated equipment. Machine learning (ML) models, and convolutional neural networks (CNNs) in particular, have demonstrated remarkable performance in signal location. However, ML models are data driven whose predictions are affected by noise in data and may also suffer from large extrapolation errors when applied to new conditions. Uncertainty quantification (UQ) is necessary to ensure model trustworthiness and avoid overconfident predictions in extrapolation. Here, in this work, we propose a novel UQ method, called PI3NN, to quantify prediction uncertainty of ML models and integrate the method with CNNs for transient source location. PI3NN calculates Prediction Intervals by training 3 Neural Networks and uses root-finding methods to determine the interval precisely. Additionally, PI3NN can identify out-of-distribution (OOD) data in a nonstationary condition to avoid overconfident prediction. Results indicate that with PI3NN, transient signals are not only correctly identified, but when said signals are subject to corruptions characteristic of an actual power monitoring system (e.g. non-ideal sensors), the model recognizes when it is uncertain about its predictions, effectively letting the user know when to accept or discard the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Locating and targeting moving tumors with radiation beams

The current climate of rapid technological evolution is reflected in newer and better methods to modulate and direct radiation beams for cancer therapy. This Vision 20/20 paper focuses on part of this evolution, locating and targeting moving tumors. The two processes are somewhat independent and in principle different implementations of the locating and targeting processes can be interchanged. Advanced localization and targeting methods have an impact on treatment planning and also present new challenges for quality assurance (QA), that of verifying real-time delivery. Some methods to locate and target moving tumors with radiation beams are currently FDA approved for clinical use--and this availability and implementation will increase with time. Extensions of current capabilities will be the integration of higher order dimensionality, such as rotation and deformation in addition to translation, into the estimate of the patient pose and real-time reoptimization and adaption of delivery to the dynamically changing anatomy of cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-179: Exploring Appropriate Offset Values for Pencil Beam and Monte Carlo Dose Optimization in Lung Stereotactic Body Radiotherapy Encompassing the Effects of Respiration and Tumor Location

Purpose: Exploring appropriate offset values in dose optimization with pencil beam (PB) algorithm to minimize dosimetric differences with plans calculated with Monte Carlo (MC) for lung cancer treatment with Stereotactic Body Radiotherapy (SBRT). Methods: 20 cases of Non-Small Cell Lung Cancer, treated with gated full motion range SBRT were selected. According to the proximity of the Gross Tumor Volume (GTV) to the chest wall, two groups are defined: peripherally located when GTV merges with the chest wall for at least 50% of the lesion diameter, and centrally located when the GTV is surrounded by lung tissue. Treatment plans were created on 4D average intensity projection (AIP) CT set with Brainlab iPlanDose 4.1.2 planning system. The D97 of PTV was normalized to 50Gy using the fast PB and compared with MC. The optimized plan was then recomputed over each 4D respiratory phase, and compared with MC using the same plan MU's. Results: The mean difference in the PB and MC D97 of the ITV was 10.5% (±0.8%) of the prescription dose (50Gy). PB algorithm showed 2.3–2.4% less overestimation to the D97 of the ITV, when comparing to MC, in the maximum exhalation phase than in the maximal inhalation phase. Significantly smaller dose difference between PB and MC is also shown in plans for peripheral lesions (7.7 ± 0.7%) versus for central lesions (12.7±0.8%) (p< 0.01). Conclusion: The dosimetric differences between PB and MC can be reasonably predicted depending on the location of lesion in the lung, and may be used as offset value in dose optimization with PB. Since the maximal exhalation phase demonstrates less dose discrepancy between the two algorithms than that in maximal inhalation phase, caution is suggested when the latter is included as a major phase portion in the respiration gated lung SBRT.

60 APPLIED LIFE SCIENCES↗

SU-E-J-107: The Impact of the Tumor Location to Deformable Image Registration

Purpose: For four-dimensional planning and adaptive radiotherapy, the accuracy of deformable image registration (DIR) is essential. We evaluated the accuracy of an in-house program with the free-downloadable DIR software library package (NiftyReg) and two commercially available DIR software programs (MIM Maestro and Velocity AI) in lung SBRT cancer patients. In addition to it, the relationship between the tumor location and the accuracy of the DIRs was investigated. Methods: The free-form deformation was implemented in the in-house program and the MIM. The Velocity was based on the B-spline algorithm. The accuracy of the three programs was evaluated in comparison for the structures on 4DCT image datasets between at the peak-inhale and at the peak-exhale. The dice similarity coefficient (DSC) and normalized DSC (NDSC) were measured for the gross tumor volumes from 19 lung SBRT patients. Results: The DSC measurement showed the median values of the DSC were 0.885, 0.872 and 0.798 for the In-house program, the MIM and the Velocity, respectively. The Velocity showed significant difference compared to the others. The median NDSC values were 1.027, 1.005 and 0.946 for the In-house, the MIM and the Velocity, respectively. This indicated that the spatial overlap agreement between the reference and the deformed structure for the in-house and MIM was comparable with the accuracy within 1mm uncertainty. There was larger discrepancy within 1–2mm uncertainty for the Velocity. The In-house and the MIM showed the higher NDSC values than the median values when the GTV was not attached to the chest wall and diaphragm(p < 0.05). However, there is no relationship between the accuracy and the tumor location in the Velocity. Conclusion: The difference of the DIR program would affect different accuracy and the accuracy may be reduced when the tumor is located or attached to chest wall or diaphragm.

60 APPLIED LIFE SCIENCES↗

SU-F-J-21: Clinical Evaluation of Surface Scanning Systems in Different Treatment Locations

Purpose: To reduce imaging dose in fractionated IGRT, the ability of optical surface imaging systems (OSIS) to detect setup errors was tested. Therefore, clinical studies to evaluate for different treatment locations setup corrections derived by OSIS in comparison with x-ray image guidance in fractionated radiation therapy was performed. Methods: The setup correction accuracy of an OSIS system (AlignRT, VisionRT, London, UK) will be analysed for the 4 tumour locations Pelvis, Upper Abdomen, Thorax and Breast, 20 patients for each location in comparison to a different system (Sentinel, C-RAD, SE). For each patient, the setup corrections of the cone-beam computed tomography (CBCT) of an Elekta Versa HD linear accelerator (Elekta, Crawley, UK) is considered as gold-standard and then compared with those of the OSIS for the first ten fractions retrospectively. There were no clinical decisions made based on the surrogate system. For the OSIS, the reference surface is highly important as it represents the actual ground truth. It can be obtained either with the system itself or the surface structure delineated in the planning CT can be imported via DICOM interface. In this paper, the first results for the treatment region thorax are presented. The reference image modalities were compared. Results: Table 1 displays the difference between the setup corrections obtained with OSIS and CBCT in lateral (LAT), longitudinal (LNG) and vertical (VRT) direction for the DICOM reference image. While the median deviations are within a few millimeters, some outliers showed large deviations. Generally, the mean deviation as well as the spread was smallest in lateral and largest in vertical direction. Conclusion: Although the system allows fast, simple and non-invasive determination of setup corrections, it should be evaluated treatment region dependant. Therefore, the study is ongoing. The application of OSIS may help to reduce the imaging dose for the patient. We gratefully acknowledge the support by our colleagues from the Radiological University Clinic Heidelberg, where the study was performed. This work was funded by the Federal Ministry of Education and Research (BMBF) Germany, grant number 01IB13001B.

60 APPLIED LIFE SCIENCES↗

Formation of ncl-Si in the Amorphous Matrix a-SiO{sub x}:H Located near the Anode and on the Cathode, Using a Time-Modulated DC Plasma with the (SiH{sub 4}–Ar–O{sub 2}) Gas Phase (C{sub O{sub 2}} = 21.5 mol %)

The formation of ncl-Si in the amorphous matrix a-SiO{sub x}:H using a time-modulated DC plasma at an elevated oxygen content of C{sub O{sub 2}} = 21.5 mol % in a gas mixture of (SiH{sub 4}–Ar–O{sub 2}) is investigated. Plasma modulation implies the repeated (n = 180) switching on (for t{sub on} = 5, 10, 15 s) and switching off (for t{sub off} = 5, 10, 15 s) of the magnet coil of the DC magnetron. The effect of self-induction is used to enhance the processes of SiH{sub 4} dissociation, the formation of Si nanoparticles, and the ionization of oxygen and ncl-Si flows towards the electrodes. The samples are located both on an electrically isolated substrate holder near the anode and on the cathode (beyond its erosion zone). These experiments show that the shape of the dependences of the photoluminescence intensity I{sub PL}{sup ncl−Si} on the wavelength Λ are identical for all pairs of samples on the anode and cathode. When the t{sub on} value is small (t{sub on} = 5 s), the difference in the sample location only slightly affects the infrared (IR) spectra. At longer times t{sub on} (≥10 s) and a short time t{sub off} (5 s), the amorphous matrix located on the cathode is enriched with oxygen (as compared with that near the anode). The optimal plasma-modulation parameters are found to be t{sub off}/t{sub on} = 5, 10, 15/10 and t{sub off}/t{sub on} = 5, 10/15; under these conditions, the amorphous matrix has a “perfect structure” and is transparent to radiation, and the I{sub PL}{sup ncl−Si} value is the largest in the range λ ≈ 0.75–0.9 μm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensitivity of the Southern Hemisphere Wintertime Teleconnection to the Location of ENSO Heating

The Southern Hemisphere extratropical atmospheric circulation response to anomalous convection in the tropical western and eastern Pacific Ocean is distinctly different. The response to westward-located heating has a meridional dipole in the South Pacific with large zonal scale and appears unable to be interpreted simply as a stationary Rossby wave train that disperses poleward and eastward from a tropical source like the meridionally arched response to eastward-located heating. Here, this study investigates the cause of this asymmetry by examining the daily evolution of the response to suddenly switching on steady diabatic heating over a western and central/eastern equatorial Pacific location using large-ensemble integrations from the Community Atmosphere Model version 5. We focus on the austral winter months when the subtropical jet supports the development of an effective Rossby wave source in the subtropical westerlies and acts as a waveguide. We show that the subtropical jet strongly influences the height response to the western tropical Pacific heating, promoting prominent zonal circumglobal propagation. Development of a transient eddy feedback in the extratropical storm track after approximately 10 days appears to play a primary role in establishing the time-mean response, which we test through comparison with similar experiments conducted using a simplified linear model. Conversely, the height anomalies for eastern tropical Pacific heating, farther away from the subtropical jet core, have larger meridional propagation, dispersing in a typical Hoskins–Karoly manner into the Southern Hemisphere extratropics, while the transient eddy feedback plays a secondary role for the establishment of the steady response.

54 ENVIRONMENTAL SCIENCES↗

Assessment of design and location of an active prechamber igniter to enable mixing-controlled combustion of ethanol in heavy-duty engines

Here, this numerical study focuses on assessing the key design parameters of interest for use of an active prechamber igniter as an ignition assistance device to enable mixing-controlled combustion (MCC) of ethanol (E100) in a heavy-duty Caterpillar C9.3B engine. Computational fluid dynamic (CFD) simulations of a baseline diesel and prechamber retrofitted C9.3B at a gross indicated mean effective pressure (IMEPg) of 5 bar and 1800 rpm are carried out using CONVERGE. In particular, the sizing of the prechamber volume, sizing of total orifice cross sectional area (orifice diameter), and location of the prechamber relative to a centrally mounted common rail direct injector are varied to discern the appropriate operational and design characteristics to achieve robust ignition assistance at the selected conditions. Simulation results indicate that use of an active prechamber igniter with E100 as a standalone fuel source can replicate ignition delays and thermal efficiencies similar to diesel combustion at the same engine boundary conditions, thus not requiring any changes to the engine’s air handling system. Igniter mounting location, orifice sizing, and jet targeting were found to have the strongest influence on ignition assistance with preference toward larger orifice diameters that appropriately located heating contributions in near vicinity to the direct injector.

33 ADVANCED PROPULSION SYSTEMS↗

FALDO: a semantic standard for describing the location of nucleotide and protein feature annotation

Nucleotide and protein sequence feature annotations are essential to understand biology on the genomic, transcriptomic, and proteomic level. Using Semantic Web technologies to query biological annotations, there was no standard that described this potentially complex location information as subject-predicate-object triples. In this paper, we have developed an ontology, the Feature Annotation Location Description Ontology (FALDO), to describe the positions of annotated features on linear and circular sequences. FALDO can be used to describe nucleotide features in sequence records, protein annotations, and glycan binding sites, among other features in coordinate systems of the aforementioned “omics” areas. Using the same data format to represent sequence positions that are independent of file formats allows us to integrate sequence data from multiple sources and data types. The genome browser JBrowse is used to demonstrate accessing multiple SPARQL endpoints to display genomic feature annotations, as well as protein annotations from UniProt mapped to genomic locations. Our ontology allows users to uniformly describe – and potentially merge – sequence annotations from multiple sources. Finally, data sources using FALDO can prospectively be retrieved using federalised SPARQL queries against public SPARQL endpoints and/or local private triple stores.

59 BASIC BIOLOGICAL SCIENCES↗

Procedure for locating oil and gas wells in the Appalachian Basin

Locating undocumented (or poorly documented) oil and gas wells for environmental assessment is often difficult. Remnant features that confirm the presence of a well (intact casing/wellhead, well bore, etc.) are typically less than a meter in size and often are obscured from direct observation on the ground or from the air (by dense vegetation, for example). To efficiently find such features, it is useful to first systematically compile publicly available digital data at progressively smaller scales prior to embarking on field campaigns. Further, the information presented here describes the procedure developed and used by the U.S. Department of Energy's National Energy Technology Laboratory to locate potential oil and gas well sites for follow-up field verification and characterization. Digital data are first compiled from national and state resources such as well location/production databases, historical topographic maps, historical aerial photographs, and LiDAR data. Although each data set is likely to be incomplete or inaccurate to some extent, combining the data resources using geographic information system technology can generate potential well site targets with a higher degree of confidence, which improves the efficiency of fieldwork activities. This workflow was developed in the Appalachian Basin region, and although certain aspects may be unique, the general process would be applicable to locating undocumented wells in other regions.

54 ENVIRONMENTAL SCIENCES↗

Laparoscopic Isolated Total Caudate Lobectomy for Hepatocellular Carcinoma Located in the Paracaval Portion of the Cirrhotic Liver

Background: Despite the widespread use of laparoscopic hepatectomies in past decades, laparoscopic isolated total caudate lobectomy for hepatocellular carcinoma (HCC) remains challenging,{sup 1,2} especially for patients with cirrhosis. Moreover, a laparoscopic isolated total caudate lobectomy for HCC originating in the paracaval portion of the caudate lobe is very rare. We herein present a video showing laparoscopic total caudate lobectomy for a cirrhotic patient with HCC located in the paracaval portion of the caudate lobe. Methods: A 58-year-old woman who suffered from hepatitis C virus-related cirrhosis was admitted to our institution. The preoperative computed tomography showed a 2.5 × 2.0 cm liver mass located in segment I that was very close to the right hepatic pedicle. Although her liver function was Child–Pugh A, the indocyanine green (ICG)-15 test was high at 10.9%. Right hepatectomy plus caudate lobectomy was not adopted because of the severe cirrhosis and the elevated ICG-15. Thus, laparoscopic isolated total caudate lobectomy was contemplated. Results: The patient was placed in the supine position. After full mobilization, the caudate lobe was exposed. The third porta of the liver was then dissected and the short hepatic veins were controlled with clips and LigaSure. The dissection was finished when the whole third porta of the liver was freed. Subsequently, the portal branches to the caudate lobe were ligated and cut. The combination between the left- and right-sided laparoscopic approaches was used to transect liver parenchyma. The superficial parenchyma was divided using an harmonic scalpel, while the deeper tissue was divided using a Cavitron ultrasonic aspirator (CUSA). The Pringle maneuver was used intermittently during the parenchymal transection as necessary. In the left-sided approach, the caudate lobe was resected along the left and middle hepatic vein toward the right side, to expose the dorsal semicircle of the right hepatic vein. In the right-sided approach, the resection started from the right border of the process portion to the root of the right hepatic vein in the cranial direction. Finally, the whole caudate lobe was resected and the three main hepatic veins were exposed on the cutting plane. The specimen was removed from suprapubic incision. The operative time was 300 min and the total Pringle time was 50 min. The postoperative course was uneventful. Conclusions: A laparoscopic isolated total caudate lobectomy for HCC located in the paracaval portion of the cirrhotic liver seems to be feasible and safe in selected patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗